• 제목/요약/키워드: Natural source

검색결과 2,100건 처리시간 0.03초

Nonlinear Motion Responses of a Moored Ship beside Quay (안벽에 계류된 선박의 비선형 운동응답)

  • 이호영;임춘규;유재문;전인식
    • Journal of Ocean Engineering and Technology
    • /
    • 제17권4호
    • /
    • pp.8-15
    • /
    • 2003
  • When a typoon sets into harbour, a moored ship shows erratic motions and even mooring line failure may occur. such troubles may be caused by harbour resonance phenomena, resulting in large motion amplitudes at low frequency, which is close ti the natural frequency of th moored ship. The nonlinear motions of a ship moored to quay are simulated under external forces due to wave, current including mooring forces in time domain. The forces due to waves are obtained from source and dipole distribution method in the frequency domain. The current forces are calculated by using slow motion maneuvering equation in the horizontal plane. The wind forces are calculated from the empirical formula of ABS and the mooring forces of ropes and fenders are modeled as linear spring.

Detecting of the defects of pavement of a road by using infrared thermography (열화상 비파괴 검사법을 이용한 도로포장 결함 검출)

  • Sim, Jun-Gi;Kim, Ki-Hyun
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • 제6권3호
    • /
    • pp.69-76
    • /
    • 2015
  • The purpose of this paper is to find an limitation to detect the defect of damaged asphalt pavement structures for infrared thermography. We use heat source of a natural light to detect the defect efficiently. The heat source was applied to the asphalt specimens. Four asphalt specimens were used: one was the asphalt containing depth of 1cm internal timber, two was the asphalt containing depth of 2cm internal void, Three was the asphalt containing depth of 3cm internal timber and four was not the asphalt containing internal timber. It was found that the depth of 3cm internal timber could be detected by this method. In addition, we used the image processing to make the damage zone displayed clear in the image obtained from the thermographic operation.

Utilization of Deodorized Poultry Feces with Tolura sp. CH-30

  • Choi, Moo-Young;Lee, Eun
    • Journal of Microbiology and Biotechnology
    • /
    • 제2권4호
    • /
    • pp.273-277
    • /
    • 1992
  • Treatment of poultry feces with Tolura sp. CH-30 produced a material that was significantly deodorized and showed a promotive effect on plant growth. Tolura sp. CH-30 grew on the poultry feces, deodorizing the feces by assimilation of volatile fatty acids, which are the source of the offensive odor, as a carbon source. Significant degradation of uric acid also occurred. In the treatment of feces with Tolura sp. CH-30, it was possible to deodorize feces in a short time, but reduction in the amount of urate-N was not enough. Urate-N inhibited plant growth due to an excessive nitrogen content produced as a result of rapid decomposition. Therefore, we propose a recycle-treatment plan using poultry feces treated with Tolura sp. CH-30. After the recycle-treatment, the amount of urate-N contained in the recycle-treated poultry feces was small and the recycle-treated poultry feces showed a promotive effect on plant growth when it was added at a nitrogen content of 1.6 g/600 g soil/pot.

  • PDF

Management Strategy for Soil and Groundwater Conservation (토양 및 지하수 보전을 위한 토양관리 및 대책방안)

  • 김경숙;정재춘
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.221-224
    • /
    • 1998
  • Environmental pollution is continuously increasing with the economic growth and industrial development. With this trend, soil and groundwater pollution problem has been surfaced as important social issues. Recently, Korean government promulgated the Soil Environment Conservation Act. But there are many problems to control sound soil quality management. Anthropogenic source of pollution such as waste landfill, pesticides, fertilizer, underground storage oil tanks is important as well as natural source such as acid rain and forest fire. The regulation should be expanded to include groundwater preservation as well as soil quality, because soil pollution is closely related to groundwater pollution. Therefore, legal regulations must be expanded to these facilities and take into account technical feasibility and finance.

  • PDF

An Examination Performed to Identify the Causative Agent of Crusian Carp (Carassius carassius) Mass Mortality in Jinyangho

  • Shin, Gee-Wook;Lee, Hu-Jang;Jung, Tae-Sung
    • Journal of Environmental Health Sciences
    • /
    • 제29권4호
    • /
    • pp.1-3
    • /
    • 2003
  • Jinyangho is a natural water supply source of tap water in west Gyeongnam area, but mass mortality of crusian carp occurred during the time of temperature rise in spring. Examinations on diseased fishes were able to isolate four bacteria isolates and then identified the bacteria as a member of Aeromonas sp. Challenge experiment with mirror carp (Gyrinus carpiospecilaris) was proved the virulence, the isolates were in turn believed as the causative agent of mass mortality in Jinyangho.

Global Carbon Budget and Ocean Buffering against Rising Atmospheric CO2 Concentration

  • Kwon, O-Yul
    • Journal of Environmental Science International
    • /
    • 제11권8호
    • /
    • pp.773-781
    • /
    • 2002
  • The natural carbon cycle has been perturbed since the mid-19th century by anthropogenic CO$_2$emissions from fossil fuel combustion and deforestation due to population growth and industrialization. The current study simulated the global carbon cycle for the past 42 years using an eight-box carbon cycle model. The results showed that since the terrestrial biospheric carbon sink was roughly offset by the deforestation source, the fossil fuel emission source was partitioned between the atmospheric and oceanic sinks. However, the partitioning ratio between the atmosphere and the ocean exhibited a change, that is, the carbon accumulation rate was faster in the atmosphere than in the ocean, due to a decrease in the so-called ocean buffering capacity. It was found that the ocean buffering capacity to take up excess CO$_2$decreased by 50% in terms of the buffer factor over the past 42 years. Accordingly, these results indicate that if the current CO$_2$emission trend continues, the future rate of increase in the atmospheric CO$_2$concentration will accelerate.

Assessment of Non-Point Source Pollutant Loads and Priority Management Areas using an HSPF Model in Sejong City, South Korea

  • Lim, Dohun;Lee, Yoonjin
    • Journal of Environmental Science International
    • /
    • 제26권8호
    • /
    • pp.881-891
    • /
    • 2017
  • In this study, the discharge loads of non-point pollution sources were analyzed using a Hydrologic Simulation Program-Fortran (HSPF) model for 46 sub-watersheds in order to guide the management plan for water and streams passing through the city. The results using HSPF showed good applicability in comparison to point measurements, which were based on BOD, TP, and TN. The mean value of the BOD loads was $4.08kg/km^2$ per day, and the highest level of BOD was $17.75kg/km^2$ per day at Namri. Three potential areas of high priority for the installment of constructed wetlands were selected in order to reduce non-point pollution sources based on BOD loads and on environmental and economic conditions. The results for these scenarios indicated a maximum rate of reduction in BOD of 39.12% within the proposed constructed wetlands.

A Study on the Prediction of Combustion Gas Behavior Induced by Fire in a Building (건물내 화재에 의한 연소가스 거동 예측에 관한 연구)

  • Pak, H.Y.;Park, K.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제6권3호
    • /
    • pp.267-281
    • /
    • 1994
  • The Combustion gas behavior induced by fire in a building is numerically investigated. The typical building for this analysis is partially divided by a vertical baffle projecting from the ceiling. The solution procedure includes the low Reynolds number ${\kappa}-{\varepsilon}$ model for the turbulent flow and the discrete ordinates method is used for the calculation of radiative heat transfer equation. The effects of the location and size of fire source and baffle length on velocity and temperature distributions, species mass fraction and flame location are analyzed. As the results of this study, it is found that the case when the fire source is located at the vertical wall is more dangerous than at the bottom wall in view of the combustion products and flame location. It is also found that the radiation effect cannot be neglected in analyzing the building in fire.

  • PDF

Exploration of a Light Shelf System for Multi-Layered Vegetable Cultivation (자연광 다층 작물재배를 위한 광선반 시스템에 관한 연구)

  • Jang, Seong-Teak;Chang, Seong-Ju
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.61-66
    • /
    • 2013
  • This study is to eliminate the need for conventional high density plant factory's artificial light source such as LED to reduce the initial investment of the light source installation as well as the operation cost. Use of solar light could enhance the quality of the vegetables similar to those grown in the natural environment. Provision of solar light into the multilayer vegetable cultivation facilities and collecting maximum and sustainable sunlight without too much loss by tracing solar path and properly distributing it through careful control during daytime are crucial for realizing the investigated rooftop light shelf system for multi-layered vegetable cultivation. In this study, we developed an innovative way of effectively allocating sunlight inside even to otherwise shaded zone of a multi-layer vegetable cultivation facility. To prove the effectiveness of the system's sunlight collection and distribution capability, both simulation and experiment in Daejeon are performed and the outcome is analyzed.

Dynamic characteristic analysis of SMT mounter system (SMT 마운터의 동특성 분석)

  • Rim, Kyung-Hwa;Jung, Jin-Ho;Beom, Hee-Rak
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.440-445
    • /
    • 2011
  • Dynamic characteristic analysis is required in developing SMT mounter system with high installation speed and position precision, because of vibration source occurred by positioning head. This paper presents the method of improving dynamic characteristic of SMT(Surface Mount Technology) mounter with finite element method and modal test. The design direction is that natural frequencies of SMT mounter must be higher than the vibration source. In addition, the effect of input shaping on residual vibration reduction is investigated by simulating the response of a first-order system.

  • PDF