• Title/Summary/Keyword: Natural orifice

Search Result 29, Processing Time 0.021 seconds

Experimental Study of Variations in Combustion Characteristics with Prechamber Design Parameters in a Constant-Volume Combustion Chamber (정적연소기내 예연소실 설계인자가 연소특성에 미치는 영향에 관한 실험적 연구)

  • Yang, In-Gyu;Han, Dong-Sik;Kim, Hyun-Kyu;Chang, Young-June;Song, Ju-Hun;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.629-634
    • /
    • 2010
  • Natural gas is a promising alternative fuel that can be used to satisfy the strict engine emission regulations in many countries. To develop natural-gas engines, low emission, efficient fuel consumption, and increased power ratings have to be realized. In this study, a cylindrical constant-volume combustion chamber (CVCC) was used to investigate natural-gas combustion characteristics for different prechamber design parameters and equivalence ratios. In particular, the maximum combustion pressure and mass fraction of the burned gas were evaluated by considering orifice diameter, volume ratio of prechamber and equivalence ratio. Using this result and by analyzing the changes in combustion characteristics with variations in design parameters, the optimum prechamber parameters were determined.

Computational fluid dynamics simulation for tuned liquid column dampers in horizontal motion

  • Chang, Cheng-Hsin
    • Wind and Structures
    • /
    • v.14 no.5
    • /
    • pp.435-447
    • /
    • 2011
  • A Computational Fluid Dynamics model is presented in this study for the simulation of the complex fluid flows with free surfaces inside the Tuned Liquid Column Dampers in horizontal motion. The characteristics of the fluid model of the TLCD in horizontal motion include the free surface of the multiphase flow and the horizontal moving frame. In this study, the time depend unsteady Standard ${\kappa}-{\varepsilon}$ turbulent model based on Navier-Stokes equations is chosen. The volume of fluid (VOF) method and sliding mesh technique are adopted to track the free surface of water inside the vertical columns of TLCD and treat the moving boundary of the walls of TLCD in horizontal motion. Several model solution parameters comprising different time steps, mesh sizes, convergence criteria and discretization schemes are examined to establish model parametric independency results. The simulation results are compared with the experimental data in the dimensionless amplitude of the water column in four different configured groups of TLCDs with four different orifice areas. The predicted natural frequencies and the head loss coefficient of TLCDs from CFD model are also compared with the experimental data. The predicted numerical results agree well with the available experimental data.

Development of Catalytic Combustion Boiler in Domestic Use (가정용 촉매연소 보일러 개발)

  • Kim, Ho-Yeon;Lee, Seung-Ho;Cho, Won-Ihl;Baek, Young-Soon
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.677-682
    • /
    • 2001
  • Catalytic combustion is the environmental-friendly technology, which has been applied to a variety of areas for industrial and domestic use in recent years. Accordingly, this study performed the development of the catalytic manufacturing technology for the high temperature and of the catalytic combustor in priority, which were aimed to be applied to a commercialized boiler. Paliadium(Pd) of a noble metal was used as a catalyst for the high temperature and supported on alumina($Al_[2}O_{3}$) and zirconia($ZrO_{2}$) in constant weight ratio. Activity of Pd catalysts is compared and analyzed in the catalytic combustion of natural gas. The ratio of $Pd/Al_{2}O_{3}=4$ was found to be better than any other weight ratios in activity and durability. The performance examination of catalysts and of combustion through the plate-type combustor made it possible to be developed the cylindrical-type combustor which has increased combustion area. Catalytic combustion boiler of 25,000 kcal/hr class was also developed, which had the optimum combustion condition at the nozzle of 5.95mm and the orifice of 21mm. This condition was determined through the performance experiments of catalytic combustion boiler to which the cylindrical-type catalytic combustor was applied.

  • PDF

New Technique of Intracorporeal Anastomosis and Transvaginal Specimen Extraction for Laparoscopic Sigmoid Colectomy

  • Wang, Zheng;Zhang, Xing-Mao;Zhou, Hai-Tao;Liang, Jian-Wei;Zhou, Zhi-Xiang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.16
    • /
    • pp.6733-6736
    • /
    • 2014
  • Background: Despite the growing acceptance of laparoscopic colon surgery, an abdominal incision is needed to remove the specimen and perform an anastomosis. Recently, natural orifice specimen extraction (NOSE) and intracorporeal anastomosis have been proposed to minimize abdominal wall trauma and improve the quality of laparoscopic colon resections Objective: To evaluate the feasibility and safety of a new approach combining intracorporeal delta-shaped anastomosis and transvaginal specimen extraction for totally laparoscopic sigmoid colectomy. Materials and Methods: Mobilization of bowel and dissection of lymph nodes were performed laparoscopically. After both proximal and distal incisal edges about 10.0 cm distance from sigmoid neoplasm were transected with an Endoscopic Linear Cutter-Straight, a small incision about 1.0 cm was created on the each colon wall of the contralateral side of the mesentery. Then anvils of an Endoscopic Linear Cutter-Straight were inserted into each colon through the small incisions, and incision and anastomosis between the walls of each colon were performed with a linear stapler. A V-shaped anastomosis was made on the wall and the remnant openings was reclosed with the Endoscopic Linear Cutter-Straight. The culdotomy was enlarged with laparoscopic ultrasound dissector. Transvaginal extraction of specimens was accomplished through a wound protector. Results: Surgery was performed for 11 patients with sigmoid cancer. No intraoperative complications or conversions occurred. The mean operating time was 132 min. All the patients were treated laparoscopically without any postoperative complications. Conclusions: The procedures of intracorporeal delta-shaped anastomosis and transvaginal specimen extraction are safe and oncologically acceptable for selected colon cancer cases.

Hybrid Natural Orifice Transluminal Endoscopic Cholecystectomy in Dogs: Transgastric, Transcolonic and Transvaginal Approaches (개에서 자연개구부를 통한 하이브리드 내시경적 담낭절제술: 경위장관, 경결장 및 경질 접근법)

  • Kim, Soo-Hyun;Jeong, Seong-Mok;Shin, Sa-Kyeng;Kim, Seong-Su;Shin, Beom-Jun;Lee, Jae-Yeon;Park, Ji-Yeong;Kim, Myung-Cheol;Kim, Young-Il;Lee, Sang-Il;Kim, Ji-Yeon
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.497-505
    • /
    • 2011
  • Natural orifice transluminal endoscopic surgery is a newly emerging technique recently, with its many potential advantages in clinical practice. Cholecystectomy by Hybrid NOTES in this work, performed with single working channel endoscope in conjunction with a laparoscopic grasping forceps in dogs, is a "bridge" between laparoscopic procedure and pure NOTES. Three different approaches for cholecystectomy were carried out; transgastric, transcolonic and transvaginal. In all three approaches, abdominal opening was made by a 5 mm trocar, followed by making pneumoperitoneum of 4 mmHg with $CO_2$ insufflator. Transgastric cholecystectomy, single working channel endoscope was advanced to the peritoneal cavity through gastric incision in antral region made by endoscopic needle knife. Endoscope was retroflexed to visualize the gall bladder. Transcolonic access, incision for endoscopic entry was done at right ventral wall of descending colon, 15 cm inside from the anus. Incision in transvaginal access was made at right-ventral region, just caudal to the caudal tubercle. With the simple traction by the laparoscopic grasping forceps, good visualization of surgical field was obtained in all three groups. Cystic duct and artery were ligated with endoclips; for complete gall bladder dissection from liver, L-knife was used. Closure of incision sites were done in transgastric and transcolonic cholecystectomy by endoclips, not in transvaginal approach.

Development of the Catalytic Combustion Condensing Boiler of Lower Emission Type for Domestic Use (저공해형 촉매연소식 소형 콘덴싱보일러 개발)

  • Kim Hoyeon;Lee Seungho;Cho Wonihl;Baek Youngsoon
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.1
    • /
    • pp.45-51
    • /
    • 2001
  • Catalytic combustion is the environmental-friendly technology, which has been applied to a variety of areas for industrial and domestic use in recent years. Accordingly, this study performed the development of the catalytic manufacturing technology for the high temperature and of the catalytic combustor in priority, which were aimed to be aimed to a commercialized condensing boiler. Palladium(Pd) of a noble meta] was used as a catalyst for the high temperature and supported on $alumina(Al_{2}O_{3})\;and\;zirconia(ZrO_2)$ in constant weight ratio. Activity of Pd catalysts is compared and analysed in the catalytic combustion of natural gas. The ratio of $Pd/Al_{2}O_{3}\;=\;4$ was found to be better than any other weight ratios in activity and durability. The performance examination of catalysts and of combustion through the plate-type combustor made it possible to be developed the cylindrical-type combustor which has increased combustion area. Catalytic combustion condensing boiler of 25,000 kcal/hr class was also developed, which had the optimum combustion condition at the no221e of 5.95mm and the orifice of 21mm. This condition was determined through the performance experiments of catalytic combustion condensing boiler to which the cylindrical-type catalytic combustor was applied.

  • PDF

Transgastric Endoscopic Cholecystectomy in a Dog : Natural Orifice Transluminal Endoscopic Surgery (개에서 내시경을 이용한 경위장관 담낭절제술 1예 : 자연개구부 내시경수술)

  • Jeong, Seong-Mok;Kim, Young-Ill;Lee, Jae-Yeon;Jee, Hyun-Chul;Park, Ji-Young;Park, Jong-Heon;Kim, Ji-Yeon;Lee, Sang-Il;Kim, Myung-Cheol;Shin, Sang-Tae;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.315-319
    • /
    • 2007
  • Transgastric endoscopic cholecystectomy was successfully accomplished in a 1-year-old, 15 kg, female, mongrel dog. Single-working channel flexible gastric endoscope was used with the aid of one abdominal laparoscopic port. Gastrotomy was performed using endoscopic needle knife at the ventral antral region. Through the gastric incision endoscope was advanced and retroflexed for the visualization of gallbladder. For the better exposure of surgical field, gentle traction was applied at the fundus of the gallbladder using laparoscopic grasping forceps. Cystic duct and artery was ligated using endoclips. After transecting the duct and artery, gallbladder was dissected using endoscopic coagulating grasping forceps and needle knife. Resected gallbladder was retrieved through the mouth and gastric incision site was sutured using endoclips. There was no evidence of bile leakage or stomach leakage on postoperative day (POD) 3. On POD 16, gastric endoscopy and laparoscopy was performed. Gastric endoscopy revealed complete adhesion of incision site. The content of the peritoneum appeared healthy, with no sign of infection, bile staining, or organ injury. The omentum was adhered over resected gallbladder fossa and the serosal surface of gastrotomy site. This is the first report of NOTES cholecystectomy in the dog and provides new concept of cholecystectomy of the dog.

Long-term Outcome after Minimally Invasive Treatment for Early Gastric Cancer beyond the Indication of Endoscopic Submucosal Dissection (내시경점막하박리술의 적응증을 넘어선 조기위암의 미세침습 치료 후 장기 추적 결과)

  • Weon Jin Ko;Joo Young Cho
    • Journal of Digestive Cancer Research
    • /
    • v.5 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Background: Recently, endoscopic submucosal dissection (ESD) with laparoscopic sentinel lymph node dissection, named ESN or endoscopic full-thickness gastric resection with laparoscopic sentinel lymph node dissection, named Hybrid-natural orifice transluminal endoscopic surgery (NOTES) was suggested the possibility of minimally invasive treatment for patients with early gastric cancer (EGC) who were beyond the indication of ESD. This study aimed to evaluate the outcomes of ESN or Hybrid-NOTES. Methods: We retrospectively analyzed patients treated with these therapies from January 2009 to May 2013 in terms of short- and long-term outcomes. Each patient was diagnosed with EGC but was not included in ESD indications and had the high risk of lymph node metastasis (LNM). Results: A total of 42 patients with EGC treated by ESN or Hybrid-NOTES. Of the 21 patients who underwent ESN, a total of 4 patients underwent additional gastrectomy, 1 with LNM, 1 with surgical complication, and 2 with noncurative resection. Of the 21 patients who underwent Hybrid-NOTES, a total of 5 patients underwent additional surgery, 1 with LNM, 2 with surgical complication, and 2 with noncurative resection. Overall survival was 100% over a mean follow-up of 75 months, but 3 patients underwent ESD or gastrectomy with metachronous lesion. And 1 patient who had received ESN was found to have a metastatic lymph node and undergo palliative chemotherapy. Conclusion: ESN or Hybrid-NOTES showed favorable short-and long-term outcomes. These methods may be utilized as a bridge between ESD and gastrectomy in the case of EGC which is more likely to have LNM beyond the ESD indications.

  • PDF

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF