• 제목/요약/키워드: Natural fiber composite

검색결과 231건 처리시간 0.028초

Performance of steel beams strengthened with pultruded CFRP plate under various exposures

  • Gholami, M.;Sam, A.R. Mohd;Marsono, A.K.;Tahir, M.M.;Faridmehr, I.
    • Steel and Composite Structures
    • /
    • 제20권5호
    • /
    • pp.999-1022
    • /
    • 2016
  • The use of Carbon Fiber Reinforced Polymer (CFRP) to strengthen steel structures has attracted the attention of researchers greatly. Previous studies demonstrated bonding of CFRP plates to the steel sections has been a successful method to increase the mechanical properties. However, the main limitation to popular use of steel/CFRP strengthening system is the concern on durability of bonding between steel and CFRP in various environmental conditions. The paper evaluates the performance of I-section steel beams strengthened with pultruded CFRP plate on the bottom flange after exposure to diverse conditions including natural tropical climate, wet/dry cycles, plain water, salt water and acidic solution. Four-point bending tests were performed at specific intervals and the mechanical properties were compared to the control beam. Besides, the ductility of the strengthened beams and distribution of shear stress in adhesive layer were investigated thoroughly. The study found the adhesive layer was the critical part and the performance of the system related directly to its behavior. The highest strength degradation was observed for the beams immersed in salt water around 18% after 8 months exposure. Besides, the ductility of all strengthened beams increased after exposure. A theoretical procedure was employed to model the degradation of epoxy adhesive.

Development of dynamic behavior of the novel composite T-joints: Numerical and experimental

  • Mokhtari, Madjid;Shahravi, Morteza;Zabihpoor, Mahmood
    • Advances in aircraft and spacecraft science
    • /
    • 제5권3호
    • /
    • pp.385-400
    • /
    • 2018
  • In this paper dynamic behavior (modal analysis and dynamic transient response) of a novel sandwich T-joint is numerically and experimentally investigated. An epoxy adhesive is selected for bonding purpose and making the step wise graded behavior of adhesive region. The effect of the step graded behavior of the adhesive zone on dynamic behavior of a sandwich T-joint is numerically studied. Finite element analysis (FEA) of the T-joints with carbon fiber reinforced polymer (CFRP) face-sheets is performed by ABAQUS 6.12-1 FEM code software. Modal analysis and dynamic half-sine transient response of the sandwich T-joint are presented in this paper. Two verification processes employed to verify the dynamic modeling of the manufactured sandwich panels and T-joint modeling. It has been shown that the step wise graded adhesive zone cases have changed the second natural frequency by about 5%. Also, it has been shown that the different arranges in the step wise graded adhesive zone significantly affect the maximum stresses due to transient dynamic loading by 1112% decrease in maximum peel stress and 691.9% decrease in maximum shear stress on the adhesive region.

Finite element analysis and theoretical modeling of GFRP-reinforced concrete compressive components having waste tire rubber aggregates

  • Mohamed Hechmi El Ouni;Ali Raza
    • Steel and Composite Structures
    • /
    • 제52권1호
    • /
    • pp.57-76
    • /
    • 2024
  • The management of waste tire rubber has become a pressing environmental and health issue, requiring sustainable solutions to mitigate fire hazards and conserve natural resources. The performance of waste materials in structural components needs to be investigated to fabricate sustainable structures. This study aims to investigate the behavior of glass fiber reinforced polymer (GFRP) reinforced rubberized concrete (GRRC) compressive components under compressive loads. Nine GRRC circular compressive components, varying in longitudinal and transverse reinforcement ratios, were constructed. A 3D nonlinear finite element model (FEM) was proposed by means of the ABAQUS software to simulate the behavior of the GRRC compressive components. A comprehensive parametric analysis was conducted to assess the impact of different parameters on the performance of GRRC compressive components. The experimental findings demonstrated that reducing the spacing of GFRP stirrups enhanced the ductility of GRRC compressive components, while the addition of rubberized concrete further improved their ductility. Failure in GRRC compressive components occurred in a compressive columnar manner, characterized by vertical cracks and increased deformability. The finite element simulations closely matched the experimental results. The proposed empirical model, based on 600 test samples and considering the lateral confinement effect of FRP stirrups, demonstrated higher accuracy (R2 = 0.835, MSE = 171.296, MAE = 203.549, RMSE = 195.438) than previous models.

미세역학적시험법과 음향방출을 이용한 Jute 및 Hemp 섬유/폴리프로필렌 복합재료의 내구성 및 계면 평가 (Interfacial and Durability Evaluation of Jute and Hemp Fiber/Polypropylene Composites Using Micromechanical Test and Acoustic Emission)

  • 김평기;장정훈;김성주;황병선;박종만
    • Composites Research
    • /
    • 제20권3호
    • /
    • pp.55-62
    • /
    • 2007
  • Jute와 Hemp 섬유/폴리프로필렌 (PP)의 내구성 및 계면 평가는 끓는 물 실험 전 후로 해서 조사되었고 끓는 물 실험 전 후에 따른 Jute와 Hemp 섬유의 수분함량은 TCA를 통해 측정되었다. 끓는 물 실험 후, Jute, Hemp섬유와 폴리프로필렌 기지재 사이의 계면전단강도와 기계적 물성은 감소하였다. 반면에 물에 의해 부풀어 오른 미소섬유에 의해 미처리경우와 비교해서 접착일은 증가를 하였다. 그리고 끓는 물 실험 전·후의 Jute, Hemp섬유와 폴리프로필렌의 표면에너지는 동 접촉각을 통해 얻어졌다. 계면전단강도는 항상 열역학의 접착일과 일치하지는 않는다. 끓는 물 내에서, Jute와 Hemp 섬유는 물에 의해 부풀어지게 된다. 그래서 표면적과 수분 침투공간이 증가한다. 끓는 물 실험 전 후의 Jute와 Hemp 섬유 미세파괴 경향은 명백하게 다르다. Jute와 Hemp 섬유/폴리프로필렌 복합재의 환경적 영향에 의한 미세파괴 형태는 광학 현미경을 통한 관찰과 음향 방출 수와 에너지에 의해 상호 일치함을 보여주었다. 끓는 물 실험 이후, Jute 섬유는 Hemp 섬유와 달리 부풀어진 피브릴에 의한 낮은 인장강도에서 나타나는 미세파괴 형태를 보여주었다. 또한, 부풀어진 피브릴에 의해 미세파괴시 음향 방출 수는 증가를 하였으며, AE 진폭과 에너지는 감소하였다.

소형민수헬기 주로터 풍동시험을 위한 마하 스케일 블레이드 설계 (Design of Mach-Scale Blade for LCH Main Rotor Wind Tunnel Test)

  • 기영중;박중용
    • 한국항공우주학회지
    • /
    • 제46권2호
    • /
    • pp.159-166
    • /
    • 2018
  • 본 연구에서는 소형민수헬기(Light Civil Helicopter, LCH)의 풍동시험에 필요한 축소 로터 블레이드에 대해 내부 구조설계와 동특성 및 하중해석을 수행하였다. 축소로터 풍동시험은 로터 시스템의 공력성능과 소음 특성을 평가하기 위해 수행되므로, 실제 크기의 로터시스템과 동일한 공력 특성을 모사할 수 있도록 축소 블레이드 설계 시 마하 스케일(Mach-scale) 기법을 적용하였다. 마하 스케일 블레이드는 실물 블레이드의 끝단속도(blade tip speed)와 동일한 값을 유지할 수 있도록 로터의 회전속도를 증가시켜야 하며, 블레이드 중량, 단면강성 및 고유진동수 등은 특정한 축소계수(${\lambda}$, scaling factor)를 통해 조정된다. 블레이드 내부의 주요 구성품인 스킨, 스파, 토션박스 등을 설계하기 위해 탄소섬유와 유리섬유 계열의 복합소재를 적용하였으며, 국내에서 수급이 가능한 프리프레그(prepreg) 형태의 복합소재를 적용하였다. 내부구조 설계가 완료된 블레이드에 대해 단면강성을 평가하기 위해 KSec2D 프로그램을 사용하였으며, 회전익 항공기의 통합해석 프로그램인 CAMRADII를 이용하여 축소 블레이드의 하중 분포와 동역학적 특성을 검토하였다.

적층판 해석시 형상비 증가에 따른 종방향 모멘트의 무시효과 (The Effect of Neglecting the Longitudinal Moment Terms in Analyzing Laminates with Increasing Aspect Ratio)

  • 한봉구;김덕현
    • 한국강구조학회 논문집
    • /
    • 제13권1호
    • /
    • pp.53-60
    • /
    • 2001
  • 건설관련 설계기술자들에게는 첨단 복합재료구조에 대한 이론이 너무 어려워서 간단하면서도 쉽게 적용할 수 있는 정확한 방법을 필요로 하고 있다. 몇 가지 섬유 배향각을 가진 적층판은 층수가 증가하면 D16, B16, D26 및 B26 강성이 감소하게 되어 특별직교이방성 판처럼 거동함을 밝히고, 간단한 공식들을 개발하여 발표한 바 있다. 대부분의 교량이나 건물의 상판은 형상비가 큰 경우가 많은데, 이런 구조물의 평형방정시에 대한 종방향 모멘트항(Mx)의 영향은 매우 작아서, 더욱 간단한 해석이 가능하다. 본 논문에는 이러한 문제들에 대한 연구 결과를 제시하였다.

  • PDF

볏짚/재활용폴리에틸렌 복합재료의 굴곡특성 및 충격강도에 미치는 볏짚의 알칼리처리 방법 및 농도의 영향 (Effect of Alkali Treatment Method and Concentration of Rice Straw on the Flexural Properties and Impact Strength of Rice Straw/Recycled Polyethylene Composites)

  • 이기영;조동환
    • 접착 및 계면
    • /
    • 제20권3호
    • /
    • pp.87-95
    • /
    • 2019
  • 본 연구에서는 볏짚/재활용폴리에틸렌 복합재료의 굴곡특성과 충격강도에 미치는 볏짚의 알칼리처리 영향을 조사하였다. 알칼리처리는 여러 가지 수산화나트륨(NaOH) 농도에서 두 가지 다른 방법으로 수행되었다. 한 가지는 정적인 soaking 방법이고, 다른 하나는 동적인 shaking 방법이다. 복합 재료는 이축압출공정으로 제조된 볏짚/재활용폴리에틸렌 펠렛을 사용하여 압축성형기술로 제조하였다. 결과는 알칼리처리 방법과 농도에 크게 의존하였다. Shaking 방법의 경우 1 wt%의 낮은 NaOH 농도에서 가장 우수한 굴곡과 충격 특성이 나타난 반면, soaking 방법의 경우에는 10 wt%의 높은 농도에서 가장 우수한 특성이 나타났다. 이러한 결과는 복합재료의 섬유-매트릭스 계면결합 현상에 의해 정성적으로 뒷받침되었다. 상기 가장 높은 물성을 갖는 두 경우 사이의 물성은 상호 비견할 만한 수준이었다. 본 연구는 10 wt% 또는 그 이상의 높은 농도의 NaOH를 사용하기보다 1wt%의 낮은 농도가 복합재료의 굴곡 및 충격 특성 향상을 위한 천연섬유의 알칼리처리에 적용될 수 있음을 제시하고 있다. 알칼리처리가 환경에 미치는 우려를 고려할 때, shaking 방법의 사용이 바람직할 수 있다.

다시마를 이용한 샐러드 드레싱 제조의 품질 특성 (Study Development of Salad Dressing with Added Sea Tangle($Laminaria$ $japonica$))

  • 정현아;김안나;안은미;박숙현;김민지;우연정;이유림
    • 한국식품영양학회지
    • /
    • 제24권4호
    • /
    • pp.520-527
    • /
    • 2011
  • 다시마를 0, 3, 6, 9, 12%로 첨가하여 제조한 '다시마 샐러드 드레싱'의 pH와 산도, 색도, 당도, Texture, 관능검사를 실시한 결과는 다음과 같다. pH의 측정 결과, 다시마의 첨가량이 증가함에 따라 pH값이 유의적으로 증가하는 경향을 나타냈으며($p$ <0.001), 산도 측정결과, 다시마 첨가량이 증가함에 따라 산도의 값은 유의적으로 감소하는 경향을 나타냈다($p$ <0.05). 색도 측정결과, 다시마 첨가량이 증가함에 따라 L값은 감소하였으며, a, b값은 증가하는 경향을 나타냈다. 당도 측정 결과, 다시마 첨가량 9%에서 가장 높은 값을 나타냈으며, 3%에서 가장 낮은 값을 나타냈다($p$ <0.001). Texture의 측정 결과, 강도와 깨짐성, 씹음성 모두에서 저장 1일차에서 가장 높은값을 나타냈으며, 대조군이 가장 높은 값을 나타냈고, 다시마 첨가량 9%에서 가장 낮은 값을 나타냈다. 관능검사 결과, Flavor 항목 중 Saltiness에서 대조군이 높은 값을 나타냈으며($p$ <0.01), Taste 항목 중 Sourness와 Sweetness에서 다시마 첨가량 6%에서 가장 높은 값을 나타냈다. Overall quality 항목에서 다시마 첨가량 3%, 6%에서 높은 값을 나타냈다($p$ <0.001). 5개의 시료 중 기호도가 가장 높았던 다시마 첨가량 6%를 이용하여 쌈무를 제조 후, 현재 시판중인 가공 쌈무와 비교하여 선호도 조사를 실시하였다. 그 결과, 총 9개의 항목 중 6개 항목에서 다시마 쌈무 선호도가 높게 나타나 천연재료를 이용한 샐러드 드레싱 개발의 가능성을 볼 수 있었다.

염수환경에 노출된 철도차량용 탄소섬유/에폭시 복합재의 내구성 평가 (Durability of Carbon/Epoxy Composites for Train Carbody under Salt Water Environment)

  • 윤성호;황영은;김정석;윤혁진
    • 한국철도학회논문집
    • /
    • 제11권4호
    • /
    • pp.357-363
    • /
    • 2008
  • 본 연구에서는 염수분무환경에 노출된 철도차량 차체용 탄소섬유/에폭시 복합재의 내구성을 조사하였다. 염수환경시험을 위해서는 해수와 가장 유사하도록 5% 염화나트륨 염수용액을 제조하여 사용하였다. 본 연구에 적용된 시편은 T700 탄소섬유직물을 에폭시 수지에 함침시킨 형태의 복합재 평판에서 채취하였다. 기계적 특성 시험을 통해 인장특성, 굽힘특성, 전단특성을 평가하였으며 동역학 측정장치를 통해 저장탄성계수, 손실탄성계수, 그리고 tan $\delta$ 등의 열분석 특성을 평가하였다. 또한 적외선 분광분석을 통해 노출기간에 따른 화학구조 변화도 조사하였다. 연구결과에 따르면 강화섬유가 지배적인 역할을 하는 기계적 특성은 염수환경에 영향을 받지 않지만 수지가 지배적인 역할을 하는 기계적 특성은 노출기간이 길어짐에 따라 점차 감소하는 양상을 나타낸다. 저장탄성계수는 노출기간에 큰 영향을 받지는 않지만 유리전이온도는 염수환경에 영향을 받으며 노출기간이 길어지면 감소하는 양상을 나타낸다. FT/IR 선도에서 관찰된 피크의 세기는 노출기간에 다소 영향을 받지만 피크의 형상과 위치는 노출 기간에 따른 변화가 관찰되지 않는다. 이로 미루어 볼 때 본 연구에 적용된 탄소섬유/에폭시 복합재는 염수환경에 비교적 안정함을 알 수 있다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF