• 제목/요약/키워드: Natural air-conditioning

검색결과 344건 처리시간 0.028초

CO2용 사판식 압축기 성능 해석 (Performance Analysis of the Swash Plate Type Compressor using CO2 Refrigerant)

  • 이건호;박익서
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.564-569
    • /
    • 2005
  • Recently, from the viewpoint of global wanning, natural gas CO2 is considered as a main refrigerant for hot water system. The characteristics of CO2 is not toxic, not flammable, high pressure, and high refrigerating capacity. Also it is widely available as a byproduct of industrial processes. This paper describes the performance analysis program of the swash plate type compressor using CO2 refrigerant. Estimates of the refrigerant flow rate, compression work, discharge temperature and volumetric, compressor efficiencies of the CO2 swash plate type compressor are obtained from the various design parameter such as the inclination angle of the swash plate, discharge hole area and suction hole area.

  • PDF

유한차분 도식에 따른 건물 계단통에서의 3차원 부력 난류유동 수치해석 (Numerical analysis of 3-dimensional buoyant turbulent flow in a stairwell model with three different finite differencing schemes)

  • 명현국
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.73-80
    • /
    • 1999
  • This paper describes a numerical study of three-dimensional buoyant turbulent flow in a stairwell model with three convective differencing schemes, which include the upwind differencing scheme, the hybrid scheme and QUICK scheme. The Reynolds-averaged Navier-Stokes and energy equations are solved with a two-equation turbulence model. The Boussinesq approximation is used to model buoyancy terms in the governing equations. Three-dimensional predictions of the velocity and temperature fields are presented and are compared with experimental data. Three-dimensional simulations with each scheme have predicted the overall features of the flow fairly satisfactorily. A better agreement with experimental is achieved with QUICK scheme.

  • PDF

한국형 태양열 온수급탕 시스템의 대책과 제안 (Measures and Proposal for Korean Solar Water Heating System)

  • 김성수;홍희기
    • 설비공학논문집
    • /
    • 제20권9호
    • /
    • pp.631-636
    • /
    • 2008
  • Solar thermal systems are recently refocused by higher oil prices, but did not completely restore the people's confidence owing to the past bad systems. Several types of solar water heating systems were analyzed in characteristics and some proper systems were proposed under Korean climates and system scale. As a small system, natural circulation system should be installed only in a southern region of Korea, with a freeze protection valve instead of heating coil for freeze protection. In most area of Korea, the forced circulation type with a heat exchange coil inside a thermal storage tank or with a spiral-jacketed storage tank, proposed and verified by the authors, has a merit of stable performance and freeze protection.

나노유체의 부력에 의한 대류 불안정성 및 자연대류 열전달 특성 해석 (Analysis of Convective Instability Induced by Buoyancy and Heat Transfer Characteristics for Natural Convetion in Nanofluids)

  • 김제익;강용태;최창균
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.714-719
    • /
    • 2004
  • The objective of the present study is to investigate the convective instability driven by buoyancy and the heat transfer characteristics of nanofluids. Using the property relations of nanofluid expressed as a function of the volume fraction of nanoparticles, the ratio of nanofluid Rayleigh number to basefluid one, f is newly defined. The results show that the density and the heat capacity of nanoparticles act as a destabilizing factor. With an increase of ${\gamma}$ which is the ratio of thermal conductivity of nanoparticles to that of basefluid, the thermal instability of nanofluid decreases but the heat transfer rate increases.

Tomographic Reconstruction of a Three-Dimensional Flow Field with Limited Interferometric Data

  • Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.11-22
    • /
    • 2000
  • Holographic interferometric tomography can provide reconstruction of instantaneous three-dimensional gross flow fields. The technique however confronts ill-posed reconstruction problems in practical applications. Experimental data are usually limited in projection and angular scanning when a field is captured instantaneously or under the obstruction of test models and test section enclosures. An algorithm, based on a series expansion method, has been developed to improve the reconstruction under the ill-posed conditions. A three-dimensional natural convection flow around two interacting isothermal cubes is experimentally investigated. The flow can provide a challenging reconstruction problem and lend itself to accurate numerical solution for comparison. The refractive index fields at two horizontal sections of the thermal plume with and without an opaque object are reconstructed at a limited view angle of 80$\circ$. The experimental reconstructions are then compared with those from numerical calculation and thermocouple thermometry. It confirms that the technique is applicable to reconstruction of reasonably complex, three-dimensional flow fields.

  • PDF

다공성 물질이 충전된 정방형 밀폐용기 내에서 수용성 혼합용액의 동결거동에 관한 실험적 연구 (Experimental Study on the freezing of Aqueous Binary Solution Saturated Packed bed in a Square Cavity)

  • 최주열;김병철
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.175-182
    • /
    • 1992
  • Freezing of the binary solution ($H_2O-NaCl$) saturating a packed bed of spheres is investigated experimentally. The system is cooled through its top surface, and the bottom is maintained at a temperature above the liquidus. Experiments are performed on the hypolutectic side, and the cold wall temperature is lower than the eutectic point. The effects of initial mixture concentration, superheat and glass bead diameter on temperature and concentration distributions are investigated. Supercooling was observed only at early times of the freezing process for experiments with 5% initial salt concentration. Flow visualization experiments and mushy-liquid interface position observations revealed natural convection in the liquid region. Remelting phenomena was not observed at both the solid-mushy and mushy-liquid interfaces.

  • PDF

양벽온이 다른 장방형용기 내에서 얼음의 융해과정에 관한 실험적 연구 (An Experimental Study on Melting Process of Ice in a Rectangular Cavity with Different Wall Temperature)

  • 임우택;김병철
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.547-555
    • /
    • 1995
  • Melting process of ice in a rectangular cavity with different temperature walls has been studied experimentally. Front shape of ice and melting rate were affected by initial temperature of ice and variation of temperature distribution and density gradient. When the hot wall temperature was below $8^{\circ}C$, the melting rates were higher at the bottom than those of at the top due to the density inversion, but with increasing the hot wall temperature the melting rates at the top were affected by hot wall and were higher than those of at the bottom. When the initial temperature of ice was low, melting rates were low, but with increasing the time melting rates were almost the same with those of each initial temperature of ice.

  • PDF

수평원관내 체적변화를 고려한 얼음의 용용시 전열특성에 관한 연구 (Melting of Ice Inside a Horizontal Cylinder under the Volume Change)

  • 조남철;김동춘;이채탈;임장순
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1266-1274
    • /
    • 2001
  • Heat transfer phenomena during melting process of the phase change material (ice) was studied by numerical analysis and experiments. In a horizontal ice storage tube, the natural convection caused an increase in melting rate. However, the reduction of the heating surface area caused a decrease in melting rate. Therefore, during the melting process of ice in a horizontal cylinder, the reduction of the heating surface area should be considered. Under the same heating wall and initial water temperature condition, the melting rate became higher for $V_s/V_tot/=0.545 \;than \;that\; for\; V_s/V_tot$/=1.00 due to the difference in the reduction of heating surface area. A modified melting model considering the equivalent thermal conductivity of liquid phase and volume reduction was proposed. The results of the model were compared with the measured values and found to be in good agreement.

  • PDF

단열재가 부착된 수직벽 표면의 온도제어 해석 (Analysis on Surface Temperature Control of an Insulated Vertical Wall Under Thermal Radiation Environment)

  • 강병하;피창헌;김석현
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.323-329
    • /
    • 2012
  • In this study, a rational procedures for estimation of insulation thickness of a vertical wall for condensation control or personnel protection has been investigated. Design parameters are height of the wall, thermal conductivity, emissivity, and operating temperatures. The results indicated that the surface emissivity plays a very important role in the design of insulation for the purpose of surface temperature control, especially in natural convection situation. radiation heat transfer coefficients for some new insulation material surface, such as elastomers, estimated to be more than 90% of the total surface heat transfer coefficient.

미립잠열재를 이용한 축열 특성에 관한 실험적 연구 (Experimental Study on the Microencapsulated PCM as a Thermal Storage Medium)

  • 이효진;이재구
    • 설비공학논문집
    • /
    • 제13권2호
    • /
    • pp.80-87
    • /
    • 2001
  • Microencapsulated PCM particles are mixed with distilled water and utilized to evaluate its characteristics and performance as a thermal storage medium transporting heat. For the present study, tetradecane(C$_14H_30, T_m=5.5^{\circ}C$) is capsulated in the core with the melamine of its surface. The size of particles is well-controlled under 10${\mu}{\textrm}{m}$ in the way of in-situ polymerization with melamine-formaldehyde resin. For the experiment, the concentrations of slurries are prepared for 20wt%, 30wt%, and 40wt%. The results are compared with those of water and 100% tetradecane oil. The pure water and tetradecane start solidifying within 20 minutes after introducing cooling water into the thermal storage tank whose tank whose flow rates are varied by 125cc/min, 250cc/min, and 500cc/min. However, MicroPCM slurries are required relatively longer period of time for their phase change than pure phase change materials. That is, the entrained MicroPCM particles control its heat transfer in terms of natural convection and conducting to them.

  • PDF