• Title/Summary/Keyword: Natural air-conditioning

Search Result 344, Processing Time 0.024 seconds

Heating and Cooling Performance of a Ground Coupled Heat Pump System with Energy-Slab (에너지슬래브 적용 지열원 열펌프 시스템의 성능 특성에 관한 실증 연구)

  • Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.196-203
    • /
    • 2012
  • Energy foundations and other thermo-active ground structure, energy wells, energy-slab, and pavement heating and cooling represent an innovative technology that contributes to environmental protection and provides substantial long-term cost savings and minimized maintenance. This paper focuses on earth-contact concrete elements that are already required for structural reasons, but which simultaneously work as heat exchangers. Pipes, energy slabs, filled with a heat carrier fluid are installed under conventional structural elements, forming the primary circuit of a geothermal energy system. The natural ground temperature is used as a heat source in winter and a heat sink in summer. The geothermal heat pump system with energy-slab represented very high heating and cooling performance due to the stability of EWT from energy slab. However, the performance of it seemed to be affected by the atmospheric air temperature.

Free Convective Heat Transfer in a Vertical Channel with Heat Source at the Wall (벽에서 열원이 있는 수직채널안의 자연대류열전달)

  • Pak, Hi-Yong;Doo, Min-Soo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.2
    • /
    • pp.108-117
    • /
    • 1985
  • In this study, a numerical analysis was performed for the natural convection heat transfer in a vertical channel which was consisted of two finite-thickness vertical walls with heat source. The ratio of the thermal conductivity of wall to air played an important role in the analysis. The case for which one side wall has protrusion resistances was also examined. The governing equations for the system was discretized by control volume formulation and solved by SIMPLE method. As the result of this study, it was found that the uniform heat flux boundary condition could be applied when the conductivity ratio was below approximately 50 and the uniform temperature boundary condition could be used when the conductivity rat io was over approximately 15,000. However, when the conductivity ratio was between 50 and 15,000, the thermal conductivity ratio value should be considered for the analysis. It was also found that the existence of protrusion resistance influenced the thermal field up to the distance of 3-4 times of the protrusion length.

  • PDF

Study on the Flow of Briquette Gas in the Ondol Heating System (Chimney Draft of Low Temperature Moist Air) (온돌의 연탄개스유량에 관한 연구(1) (함습저온열기류의 굴뚝통풍력))

  • Min Man-Ki
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.4 no.2
    • /
    • pp.119-128
    • /
    • 1975
  • Natural draft and flow which low temperature moist gas produces in the chimney of an Ondol heating system were numerically analysed. Among several factors involved inlet gas temperature has the strongest influence on the chimney performance and then next specific humidity of the gas. Thermal conductivity of the chimney wall, however, has little influence on the performance of such a low temperature chimney. Under given flow conditions there exists an optimum chimney height which gives a maximum flow rate for a given chimney diameter. This optimum value of chimney height inereases with increase in chimney diameter, inlet gas temperature and specific humidity.

  • PDF

A new method to convert into seawater heat for the indoor air-conditioning resource (건물의 냉방을 위한 해수열 취득에 관한 실험적 연구)

  • Kim Ki-Cheol;Lee Seong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.8
    • /
    • pp.883-890
    • /
    • 2005
  • The industrial growth and the raised living quality have led to the massive energy consumption. As a result. the polluted environment and the limited amount of energy resources emerged as serious problems to be resolved in 21st century. Especially, in the case of Korea whose imported energy dependency rate is 98.2$\%$ in 2003 and constantly increasing every rear. more than 24$\%$ of overall energy consumption is for housing and commercial use. In order to cope with the shortage of natural energy resources, it is inevitable to develop alternative sustainable energy resources including seawater heat. so that they can replace existing resources. The heat transfer air velocity 3.5 m/s is proper to consideration with the body the pipe size 200A is more suitable than look due to the air velocity quantify and the ratio of pipe surface area. And the error between experimental data with simulation is below 5.34$\%$ so the suggested equation for calculating heat transfer capacity can be used. Therefore out of many methods utilizing seawater heat. this work Presents the efficiency of using sea water heat as a resource for air-conditioners which can be converted from the outside air through the air-to-heat conversion tube . Consequently. this method provides pretty reasonable energy efficiency.

The Possibility on Utilization of Underground Pit for Reduction of Cooling and Heating Load (냉방과 난방 부하 감소를 위한 지하피트의 이용 가능성)

  • Cho Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.144-150
    • /
    • 2006
  • The purpose of this study is to predict outlet temperature and humidity through underground pit for the reduction of cooling load and heating load. Commonly, the underground temperature is lower than outdoor in summer but the reverse happens in winter. When the outdoor average air temperature is $25.7^{\circ}C$ during cooling periods, the average outlet air temperature through underground pit is $23.6^{\circ}C$ with 3 m-depth and 60m-length and is $22.2^{\circ}C$ with 3 m-depth and 150 m-length. When the outdoor average air temperature is $4.9^{\circ}C$ during heating periods, the average outlet air temperature through underground pit is $7.7^{\circ}C$ with 3m-depth and 60 m-length and is $10.8^{\circ}C$ with 3 m-depth and 150 m-length. The outlet air temperature is affected by more length than depth of underground pit. The diffusion ratio of outdoor humidity is $-7.7\times10^{-8}kg/s$ in cooling periods and $9.29\times10^{-7}kg/s$ in heating periods.

Effect of Radiative Mean Temperature on Thermal Comfort of Underfloor Air Distribution System (바닥공조시스템에서 복사온도가 열적 쾌적성에 미치는 영향)

  • Chung, Jae-Dong;Hong, Hi-Ki;Yoo, Ho-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.11
    • /
    • pp.711-717
    • /
    • 2008
  • Despite the fact that UFAD(Under Floor Air Distribution) systems have many benefits and are being applied in the field in increasing numbers, there is a strong need for an improved fundamental understanding of several key performance features of these systems. This study numerically investigates the effect of supplied air temperature and supplied flow rate on the performance of UFAD, especially focused on thermal comfort. Also this study has compared UFAD with conventional overhead air distribution system. In contrast to the well-mixed room air conditions of the conventional overheat system, UFAD system produces an overall floor-to-ceiling airflow pattern that takes advantage of the natural buoyancy produced by heat sources in the occupied zone and more efficiently removes heat loads and contaminants from the space. Thermal comfort parameters were evaluated by CFD approach and then PMV was computed to detect the occupants' thermal sensation. Results show that radiative mean temperature plays crucial role on the evaluating PMV. Until now, the radiative temperature has been the missing link between CFD and thermal comfort, but the present study paves the way for overcoming this weakness.

Phase Equilibrium Conditions of Gas Hydrates for Natural Gas Solid Transportation and Storage (천연가스 고체수송 및 저장을 위한 가스 하이드레이트 상평형 조건에 대한 연구)

  • Jeon, Yong-Han;Kim, Jong-Yoon;Kim, Chong-Bo;Kim, Nam-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.266-273
    • /
    • 2008
  • Natural gas hydrates are ice-like solid substances, which are composed of water and natural gas, mainly methane. They have three kinds of crystal structures of five polyhedra formed by hydrogen-bonded water molecules, and are stable at high pressures and low temperatures. They contain large amounts of organic carbon and widely occur in deep oceans and permafrost regions. Therefore, they are expected as a potential energy resource in the future. Especially, $1m^3$ natural gas hydrate contains up to $172Nm^3$ of methane gas, de pending on the pressure and temperature of production. Such large volumes make natural gas hydrates can be used to store and transport natural gas. In this study, three-phase equilibrium conditions for forming natural gas hydrate were numerically obtained in pure water and single electrolyte solution containing 3 wt% NaCl. The results show that the predictions match the previous experimental values very well, and it was found that NaCl acts as an inhibitor. Also, help gases such that ethane, propane, i-butane, and n-butane reduce the hydrate formation pressure at the same temperature.

Performance of Alternative Refrigerants for R12 and R134a in Automobile Air-Conditioners (자동차 공조기용 R12 및 R134a 대체 냉매의 성능평가)

  • Baek, In-Cheol;Park, Ki-Jung;Shim, Yun-Bo;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.5
    • /
    • pp.403-410
    • /
    • 2007
  • In this study, natural refrigerants and their mixtures that can supplement and replace R12 and R134a in automobile air-conditioners are studied. R134a is currently used as the refrigerant in new motor vehicle air conditioners, replacing the ozone depleting refrigerant R12. Although R134a has no ozone depletion potential, it has a relatively large global warming potential, approximately 1300 times that of $CO_2$ over a 100 year time horizon. For this reason, performance of natural refrigerants and their mixtures containing R152a, RE170 (Dimethylether, DME) and R600a (Isobutane) are measured under 2 different temperature conditions. They were tested in a refrigerating bench tester with an open type compressor. The test bench provided about 4 kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. Test results show that the coefficient of performance (COP) of these refrigerants is up to 21.55% higher than that of R12 in all temperature conditions. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for automobile air-conditioners.

Performance Analysis of Cascade Refrigeration System with Respect to Refrigerants Appling to High Temperature Cycle (고온측 냉매에 따른 이원 냉동시스템의 성능 분석)

  • Yoon, Jung-In;Jeon, Min-Ju;Son, Chang-Hyo
    • Journal of Power System Engineering
    • /
    • v.21 no.3
    • /
    • pp.45-50
    • /
    • 2017
  • This paper presents the Coefficient of performance(COP) and mass flow ratio of cascade refrigeration system with respect to refrigerants appling to high temperature cycle. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporating temperature, condensing temperature and internal heat exchanger effectiveness in high temperature cycle. The result of this study is as follows : The COP of cascade system increases with increasing degree of superheating and subcooling, compressor efficiency and internal heat exchanger effectiveness except increasing condensing temperature. The mass flow ratio of low and high temperature cycle increases with increasing evaporating temperature and condensing temperature, but decreases with increasing internal heat exchanger effectiveness, degree of superheating and subcooling. Also, the mass flow ratio has no correlation with compressor efficiency at high temperature cycle.

The Study on the Performance Characteristics due to the Degree of Superheat in $NH_3$ Refrigeration System (III) -The Comparison of Heat Exchanger Types- ($NH_3$ 냉동장치의 과열도에 관한 성능 특성 연구(III) -열교환기 타입별 비교-)

  • Lee Jong-In;Kim Yang-Hyun;Park Chan-Soo;Ha Ok-Nam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1132-1138
    • /
    • 2005
  • Recently, production and use of freon substances are restrained due to depletion of ozone layer and global warming. In this aspect of environmental problems, the best solution is to use the natural refrigerant such as ammonia. Thus, this study is to find the optimal operating conditions by comparing the performance between the shell and tube type and shell and disk type heat exchangers using the ammonia refrigerant, and to verify the superiority of the shell and disk type heat exchanger that is not used in field of refrigeration and air conditioning. Finally, this study shows that the shell and disk type heat exchanger is applicable to the ammonia refrigeration system, and this system minimizes the refrigerant charge and installation space.