• 제목/요약/키워드: Natural air-conditioning

검색결과 344건 처리시간 0.025초

정사각형 밀폐공간 내에 있는 고온부로부터의 자연대류 열전달 (Natural Convection Heat Transfer from a Hot Body in s Square Enclosure)

  • 권순석;정태현;권용일
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.147-154
    • /
    • 1992
  • Laminar natural convection heat transfer from a hot body in a square enclosure has been studied for various center positions of a hot square at Grashof number $Gr=1.5{\times}10^5$, Prandtl number Pr=0.71 and dimensionless thermal conductivity $k_g/k_f=14710$. The natural convection at the center position of a hot square; $X_c$, $Y_c=0.5$, 0.2 shows the most strong and at $X_c$, $Y_c=0.5$, 0.7 the most weak. The total mean Nusselt number at $X_c$, $Y_c=0.5$, 0.2 was 7.4% higher than that at $X_c$, $Y_c=0.2$, 0.5. The total mean Nusselt number at $X_c$, $Y_c=0.5$, 0.7 was 5.0% lower than that at $X_c$, $Y_c=0.3$, 0.5.

  • PDF

다양한 형상의 Heat Sink 열저항 특성에 관한 실험적 연구 (An Experimental Study on the Thermal Resistance Characteristics for Various Types of Heat Sinks)

  • 김종하;윤재호;이창식
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.676-682
    • /
    • 2002
  • This paper has been made to investigate the thermal performance characteristics for the several types of heat sinks such as extruded heat sink, aluminum foam heat sink, layered heat sink. The various types heat sinks are prepared and tested for natural convection as well as forced convection. The experimental results for natural convection are compared to those for three types of heat sink so that the appropriate heat sink can be designed or chosen according to the heating conditions. The overall heat transfer performances for layered heat sink, extruded heat sink and aluminum foam heat sink are almost comparable to those under natural convection and forced convection. The forced convection of layered heat sink become 1.2 times as high as those of extruded heat sink, and the forced convection of extruded heat sink become 1.2 times as high as those of aluminum foam heat sink. This study shows that bar height, bar distance and number of bar for layered heat sink are important parameters, which have a serious influence on thermal performance for layered heat sinks.

제어판이 부착된 수평격판에 의해 분리되는 밀폐공간내의 난류 자연대류 열전달 특성 (Turbulent natural convective heat transfer charateristics in a square enclosure with control plates attached at the horifontal partition)

  • 김점수
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.150-160
    • /
    • 2000
  • Turbulent natural convective flow and heat transfer in a square enclosure with horizontal partition are investigated numerically. The enclosure is composed of a lower hot and a upper cold horizontal walls and adiabatic vertical walls. Partitions carried with the upward, downward, and both control plates are attached perpendicularly to the one of the vertical insulated walls, respectively. The low Reynolds number $k-\varepsilon$ model is adopted to calculate the turbulent thermal convection. The governing equations are solved by using the finite element method with Galerkin method. The computations have been carried out by varying the length of partition, the position of control plates, and the Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height for water(Pr=4.95). When the control plates are attached at the edge of partition, the stability of oscillating flow grows wrose with the increase of Rayleigh number and the partition length. The heat transfer rate has been reducer than that of no control plate due to the restraint of control plates with the increase of Rayleigh number.

  • PDF

2개(個)의 수직(垂直) 평판(平板)핀을 가진 전도관(傳導管)으로 부터의 자연대류(自然對流) 열전달(熱傳達) (Natural Convection Heat Transfer from a Conducting Tube with Two Vertical Axial Fins)

  • 정한식;이철재;권순석
    • 설비공학논문집
    • /
    • 제3권4호
    • /
    • pp.222-230
    • /
    • 1991
  • Conjugate heat transfer by steady laminar natural convection from a conducting tube with two vertical axial fins has been studied by a finite difference numerical procedure under basic conditions; $Ra=10_6$, Pr = 5 and $L_F=0.15$. The maximum local tube Nusselt number appears at ${\theta}=140^{\circ}$ for $L_F=0.06$, at ${\theta}=130^{\circ}$ for $L_F=0.30$ and at ${\theta}=120^{\circ}$ for $L_F=0.30$, $L_F=0.06$, respectively. The maximum mean Nusselt number shows at $L_F=0.18$ for the downward fin and at $L_F=0.12$ for the upward fin. Therefore the optimized fin length is $L_F{\approx}0.15$ under these conditions. At $L_F=0.15$, the mean Nusselt number by increasing Rayleigh number is remarkably increased for downward fin and then is slowly increased except for downward fin, it by increasing Prandtl number is apparently increased at $Pr{\leq}2$, and slightly increased at Pr>2.

  • PDF

자연환기시스템의 현장 적용성 평가-열환경,에너지부분 (The Performance Field-Application of Natural Ventilation System)

  • 최동혁;최경석;강재식;이승언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.689-694
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high isulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, open module type natural ventilation window system for energy saving included a fixed and continuous quantity ventilation was developed. The purpose that indoor thermal comfort environment evaluate of indoor resident.

  • PDF

주거용 건물 유형별 자연환기시스템의 최적 설계 및 해석 (An Optimized Design and Simulation Analysis of Natural Ventilation Window System classified by Apartment type)

  • 최경석;정영선;강재식;이승언;정영용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.685-688
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high insulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement, the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, an optimized design and simulation Analysis of natural ventilation window system classified by Apartment type was evaluated by CFD Computational analysis.

  • PDF

치환환기되는 실내에 있어서 인체주변의 기류 및 온열환경 특성에 대한 검토 (Examination of Airflow and Thermal Environment Characteristic around Human Body in a Room with Displacement Ventilation)

  • 양정훈
    • 설비공학논문집
    • /
    • 제19권4호
    • /
    • pp.299-306
    • /
    • 2007
  • Recently, the numerical analysis using person shape model for CFD (Computational Fluid Dynamic) has been researched widely for the thermal comfort and inhaled air quality of human body in the indoor environments. The purpose of this research is to examine the characteristic of airflow and thermal environment around human body by the experiment of displacement ventilation that assumes the indoor environment of natural convection. In this study, thermal manikin was used instead of real human body. The Airflow characteristic around human body was measured in precision by PIV (Particle Image Velocimetry). This experimental result will be used as data for CFD benchmark test using person shape model.

커튼월의 단열 향상 및 결로 방지를 위한 통기구조 적용방안 연구 (Application of Ventilated Cavity for Enhancing Insulation and Preventing Condensation of Curtain-wall System)

  • 이선우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.21-28
    • /
    • 2017
  • Curtain-wall systems have been widely applied to buildings because of their lightweight and constructability characteristics. However, as curtain-wall systems include many building materials, vapor barriers can become damaged and condensation can occur. Due to the material properties of stone curtain-walls, the external appearance and structure of a building could be damaged and the insulating performance of the curtain-wall could be worse. Natural ventilation using an air cavity in a curtain-wall is expected to be effective for the prevention of condensation in inner walls and for the reduction of building cooling energy use in the summer. The purpose of this experimental study is to analyze the influence of a ventilated cavity on the insulating performance of a curtain-wall and the ventilated cavity depth and ratio of top opening needed to prevent condensation in a curtain-wall.

튜브의 열전도도와 튜브 외면에서의 대류열전달이 보텍스튜브의 에너지 분리에 미치는 영향 (The Effect of the Thermal Conductivity of a Tube and the Convective Heat Transfer on the Outer Surface of a Tube on the Energy Separation in Vortex Tubes)

  • 유갑중;이병화;최병철
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.845-852
    • /
    • 2001
  • The phenomena of energy separation in vortex tubes was investigated experimentally to see the effects of the conductivity of a tube and convective heat transfer on the outer surface of a tube. The experiment was carried out with different conductivity (pyrex, stainless steel and copper) of a tube and three kinds of convective heat transfer modes (adiabatic condition, natural convection (air) and forced convection (water) on the outer surface of a tube. the results were obtained that hot exit fluid temperature was highly affected by a change of conductivity of a tube when the outer surface was cooled by the forced convection of water. However, the cold exit temperature was little affected by heat transfer modes on the outer surface in vortex tubes.

  • PDF

환기식 3중 집열창의 최적설계를 위한 수치해석 연구 (Numerical analysis for the optimum design of a triple-glazed airflow window)

  • 김홍제;황기영
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.484-496
    • /
    • 1997
  • The fluid flow and heat transfer characteristics of conjugate forced and natural convection in the triple-glazed airflow window, where the outer air passes through a space contrived between the interior and exterior window panes, were studied numerically by a finite volume method for the elliptic form of the Navier-Stokes equations. The investigation focused on the influence of window geometry, ventilastion rate and solar energy on the temperature, velocity distribution and thermal performance of the airflow window. The comparison between the triple-glazed airflow window and the enclosed triple-glazed window was also made to evaluate the effect of buoyancy upon which the thermal performance of the window depended.

  • PDF