• Title/Summary/Keyword: Natural air conditioning

Search Result 344, Processing Time 0.024 seconds

Study of occurrence of cool air in summer and warm air in winter of Chonbuk Jinan Poonghyeol (전북 진안 풍혈의 여름철 냉풍 및 겨울철 온풍 발생 연구)

  • Kim, Young-Il;Shin, Young-Gy;Seo, Jeong-Ah;Choi, Yong-Don;Song, Tae-Ho;Kang, Chae-Dong;Kim, Seong-Sil;Rho, Jeong-Sun;Jeong, Si-Young;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.879-884
    • /
    • 2006
  • Jinan Poonghyeol in Chonbuk province Is famous for emitting cool air in summer and warm air in winter. Cause for these phenomena is studied by measuring temperature, humidity and air velocity of several locations around Jinan Poonghyeol Temperature variations under the ground are also measured. Analyzing data compiled from July 21, 2005 through May 26, 2006, it is presumed that storage effect of rocks and soil in this area and buoyance effect are the main causes for this mysterious natural air-conditioning phenomena.

  • PDF

Analysis on the Ventilation Rate of Express Bus according to the Geometry of Vent (고속버스의 환기구 형태에 따른 환기량 분석)

  • Shin, In-Hwaw;Yoo, Ho-Chun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.174-178
    • /
    • 2011
  • This paper deals with the free cooling system of express bus using natural energy source in order to improve the room air quality and save cooling energy. In an express bus, there are may passengers in unit area, requiring the improvement of air quality and giving higher energy saving efficiency. Particularly, the express buses running fast make it easy to take in outdoor air at a flow rate controllable with a damper mechanism. This paper proposes the analysis on the air flow achieved by a damper controlled vertically and horizontally in order not to deteriorate the ride comfort of the passengers.

  • PDF

Natural Convection from a Vertical Flat Plate with Horizontal Rectangular Fins (수직평판(垂直平板)에 부착(附着)된 수평(水平)핀에서의 자연대류(自然對流))

  • Kim, S.J.;Lee, J.C.;Seo, L.S.;Kwon, S.S.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.448-455
    • /
    • 1988
  • A study has been conducted experimentally on natural convection heat transfer characteristics of a vertical flat plate with horizontal rectangular fins in air. The effects of fin heights and Rayleigh numbers are mainly investigated. The experimental results are as follows; 1. The mean fin, plate and total Nusselt numbers decrease as dimensionless fin heights H/S increase at $0.50{\leq}H/S{\leq}2.00$. 2. The mean fin surface Nusselt number in case of H/S = 0.50 and $Ra_c=4.33{\times}10^3$ shows its maximum at $X_1$, surface where there is no interference with other fins. 3. Owing to the interference of fins the mean plate Nusselt numbers at H/S=0.50 and 2.00 for $Ra_S=6.57{\times}10^3$ are 35% and 80% respectively less than the mean fin Nusselt numbers. 4. The mean fin, plate and total Nusselt numbers of horizontal rectangular fins show higher values at short fins, but lower values at long fins than those of upward vertical fins.

  • PDF

An Analytical & experimental study on the thermal performance of trickle solar collector with Sinuous Cross-section (파형 단면을 가진 유하식 집열기의 열적 성능에 대한 이론 및 실험 연구(I))

  • Lee Jong Ho;Chung Mo;Baek Nam Choon;Auh Chungmoo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.4
    • /
    • pp.240-251
    • /
    • 1983
  • The municipal government of Daejeon, Korea set up a plan to retrofit solar energy to the existing swimming pool. The pool was constructed in 1980, and meets the requirements of International standard. It will be used for the 1986 Asian Games and the 1988 Seoul Olymipics. The roof structure of the existing pool is to be modified to accomodate trickle solar collectors. In addition, various energy conserving ideas will be applied to the existing building structure. For the prevention of over heating of collectors on the roof, natural air convection scheme will be adopted within the collector system. Natural convection of passive type heating would be also adopted for the space heating of the pool when the system is idle. At present, the pool can be utilized only for two months a year without auxilairy heating. With oil heating, the energy cost would be too high for the normal operation. When this project completed in March 1984, it would be expected to be openable for seven months a year without a significan amount of auxiliary heating. In this project, two dimensional numerical analysis technic have been used to analyse the characterisitics of thermal performance of the swimming pool system. An experimental tat verification of the theoretical analysis have been also attempted.

  • PDF

Natural Convective Heat Transfer and Flow Characteristics in Inclined Rectangular Enclosures with Localized Heating from Below (밑면에서 부분가열을 받는 경사4각형 밀폐공간내의 자연대류 열전달 및 유동특성)

  • Kim, Sang-Ho;Chung, In-Kee;Kim, Jung-Yeup
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.3
    • /
    • pp.148-156
    • /
    • 1984
  • The effect of inclination on the steady, two-dimensional, laminar natural convection in rectangular enclosures with localized heating from below has been investigated numerically. The enclosure was uniformly heated with a partial heat source at the center of the bottom wall and cooled from the upper wall while the other walls were insulated. The governing equations were solved numerically by using the ADI finite difference method with the SOR method. The computations were carrid out with air, Pr =0.733, in the Grashof number range, $1\times10^4\~3\times10^4$, for the inclination of the enclosures was varied from $0^{\circ}\;to\;90^{\circ}$. The effects of Grashof number and aspect ratio on the inclination for the transition of the flow pattern in enclosures were determined. From the results, it was found that the transition angles of the flow in the enclosures were greater in localized heating than in uniform heating from below, and that the inclination was to strongly effect on the heat transfer and the flow pattern within the enclosure.

  • PDF

IAQ Field Survey in an Apartment Housing Equiped for Heat Recovery Ventilation System with Air Cleaning Function (아파트 실내공기질 현장측정에 의한 전열교환 청정환기유니트 성능평가)

  • Yee Jurng Jae;Lee Joong Hoon;Lee Seung Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.688-693
    • /
    • 2005
  • Nowaday the natural ventilation rate decreases because the apartment housing is being air-tight. Therefore, Indoor Air Quality (IAQ) and indoor environment grow worse. Especially, Formaldehyde (HCHO), Volatile Organic Compounds (VOCs) which is emitted from the building materials and coating material etc. occur Sick House Syndrome that cause negative impact on resident's respiratory system and body. Therefore in construction field, it will be a important issues that development of a ventilation system with high effectiveness which can exhaust the contaminant out of the building quickly. In this research we evaluated 'wall attachable duct-less Heat Recovery Ventilation (HRV) system with air cleaning function'. We executed a synthetic evaluation about indoor air environment under various operating condition installing the system in real scale apartment house that is built in Anyang city. HRV system with air cleaning function showed good performance by removing HCHO, VOCs with less ventilation energy.

A Study on The Performance of Ventilation and Thermal Environment for a Combined Type Diffuser in a Residential Space (거주공간에 대한 급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • In this study, the combined-type diffuser developed by the Authors, in a previous study, was applied to a residential space. The performance of a ventilation and thermal environment, created by the use of a combined-type diffuser was compared to the pan-type diffuser widely used in apartment houses. In cooling conditions, because of the relatively high air flow rate of ceiling cassette-type air conditioners, the characteristics of airflow distribution in a room were governed by the air conditioner's airflow. In heating conditions, because of the low air flow rate of the diffuser, the characteristics of airflow distribution were governed by the buoyancy effect created by cold external walls and a hot floor. In terms of the Air Diffusion Performance Index (ADPI), which is a thermal environmental index, the result of a combined-type diffuser was greater than a pan-type diffuser in both of cooling and heating conditions. Consequently, the combined-type diffuser showed equal or superior ventilation and thermal environment performance compared to a pan-type diffuser.

Evaluation of Natural Ventilation Performance using the Multi-Functional Floor Heating System (다기능온돌시스템을 이용한 자연환기성능 평가)

  • Cho, Dong-Woo;Yu, Ki-Hyung;Yu, Jung-Yeon;Jung, Hae-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.105-112
    • /
    • 2007
  • Recently developed raised floor heating system is not only capable of basic function to reduce noise between floors, but also is a multi-functional floor heating system enabling natural ventilation. The procedure of this system for natural ventilation is to import outdoor air through bottom space of the floor heating system, circulate indoor space and discharge it out of ceiling. In winter, powerless natural ventilation is possible with buoyancy effect caused by temperature difference between outdoor and indoor. And it also allows saving of energy by importing pre-heated air in bottom space of the floor heating system. To evaluate ventilation performance of this system, on-site measurement was conducted in 2 test laboratories, and the nominal air change rate was satisfied as 0.4$\sim$0.8 h-1 under the condition of outdoor temperature $5^{\circ}C{\sim}-5^{\circ}C$, which was evaluated as highly possible to be applied as a natural ventilation system in multi-family houses.

  • PDF

Improving the natural ventilation in multi-housing units of tower-type buildings according to their shapes and directions (탑상형 공동주택의 주동형태와 배치각에 따른 주호의 자연환기 성능)

  • Yoo, Seon-Yong;Kim, Ji-Yoeng;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.897-902
    • /
    • 2006
  • Natural ventilation is an effective method for improving IAQ(Indoor Air Quality) and removing heats in buildings. In oder to use natural ventilation, many factors such as wind pressure around the buildings and possibility of air intake on different shapes need to be known. On this paper, the natural ventilation performance in multi-housing units of tower-type buildings was investigated. Tower-type multi-housing buildings are recently more and more constructed for they may change urban landscape and get more openness in multi-housing site. However, such housing buildings have problems with natural ventilation because of the various directions of the building units. The purpose of this paper is to find the proper building direction regarding to wind direction in order to optimize air intake in every units in the building.

  • PDF

A Numerical Study of The Motion of a Circular Cylinder Suspended in a Square Enclosure (사각 밀폐계 내 자연대류에 의한 원형 실린더의 운동 특성에 관한 수치적 연구)

  • Son, Seong-Wan;Jeong, Hea-Kown;Ha, Man-Yeong;Yoon, Hyun-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.727-734
    • /
    • 2010
  • The present study numerically investigates the motion of a solid body suspended in the square enclosure with natural convection. A two-dimensional circular cylinder levitated thermally has been simulated by using thermal lattice Boltzmann method(TLBM) with the direct-forcing immersed boundary method. To deal with the ascending, falling or levitation of a circular cylinder in natural convection, the immersed boundary method is expanded and coupled with the TLBM. The circular cylinder is located at the bottom of a square enclosure with no restriction on the motion and freely migrates due to the Boussinesq approximation which is employed for the coupling between the flow and temperature fields. For different density ratio between the cylinder and the fluid, the motion characteristics of the circular cylinder for various Grashof numbers have been carried out. The Prandtl number is fixed as 0.7.