• Title/Summary/Keyword: Natural Type Facility

Search Result 85, Processing Time 0.024 seconds

A Study for selecting the Highway Sites' Best Management Practice for Nonpoint Source Pollution (고속도로 현장별 비점오염 저감시설 선정방안 연구)

  • Lee, Yong-Bok;Choi, Sang-Il;Park, Kye-Su;Seong, Il-Jong;Jung, Sun-Kook
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.857-866
    • /
    • 2011
  • This research categorized EIA target highways into following three types in order to minimize non-point source pollution from highway runoff. 1. Big drainage basin. 2. Small drainage basin. 3. Bridge section. The Natural, Filter and Swirl-Type devices were evaluated in terms of removal efficiency of TSS, BOD, COD, T-N, T-P, compatibility of site selection, economic feasibility, and maintenance convenience through which the final BMP was selected. According to the removal efficiency result, the area of Big and Small Drainage basin and bridge section had higher removal efficiency with natural facility than that of the Filter or Swirl-Type device. To make appropriate selection of highways'BMP for non-point source pollution, this study will aim to contribute to building more environmentally friendly highways by proposing the selection process that is made of 5 stages. 1. Selecting the target drainage basin. 2. Selecting the land for the mitigation facility. 3. Analysing the ease of maintenance. 4. Technically evaluating each installation. 5. Evaluating the effective implementation methods.

A Study on the Suggestion of the Spatial Model for the Tourism Farm (관광농원 단위 공간 모델에 관한 연구)

  • 김정화;이춘석
    • Journal of Korean Society of Rural Planning
    • /
    • v.3 no.1
    • /
    • pp.68-76
    • /
    • 1997
  • The purpose of this study is to suggest the spatial model which can be applied to the tourism farm plan. This study includes : (1) the analysis of existing facilities and activities of 22 tourism farms in Kyunggido and (2) the survey questionnaire about user's attitudes in 3 tourism farms. The results can be summarized as follows : 1) The .Major activities in the tourism farm are the resting/playing based on the natural environment and group meeting. 2) Average area is 17879.4uf (5418 坪). The most frequent facility is restaurant and lodge. 3) It is necessary to propose various types of tourism farm considering both natural conservation and development of rural region and users'various wants. The tourism farms are officially classified into four types Natural education type, Mind and body training type, Weekend farm type, Recreation type. 4) The space for tourism farm is divided into an area of production, and area of processing, and an area of convenience/recreation. 5) It is desired the convenience facilities are located in front of a farm, and the area of production is located at the back of a farm, and simple rest facilities are located all of the farm. 6) The weekend farm model and processing/convenient facility model are proposed in this study. Three types of the weekend farm models are proposed - simple type, composite type, and garden type. Three types of the processing/convenient models are proposed one building type, adjacent building type, and scattered building type.

  • PDF

A study on Daylighting inducement within bedroom of Elderly care facility by light shelf attaching method for Therapeutic environment - By Dynamic Daylight Simulation Using Weather Data - (치유환경을 위한 광선반 부착방법에 따른 노인요양시설 침실 내 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Cho, Ju-Young;Lee, Ki-Ho;Yun, Young-Il;Lee, Hyo-Won
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.71-79
    • /
    • 2011
  • There are high recognitions on the importance of comforts in Elderly living environment, but the circumstance is that studies on seniors facility space itself are approached only in planning level, and studies on lighting environment which is significantly associated with the comfort in the indoor environment of seniors where they actually spend the majority of their time are not that active. This study was intended to deduce cozy bedroom environment to which existing elderly care facility can be improved by using light shelf the lighting system with the advantage of being able to serve both as building sun visor and lighting window simultaneously in order to analyze the interior environment of bedroom space of elderly care facility the indoor space where the aged spend the majority of their life and examine the directions for the improvement of existing building lighting system through remodeling and renovation. In this study, lighting performance analysis was done in a way that the windows of the bedroom unit in existing facility were set in southbound direction based on two standard types and were put under initial simulation with the use of Autodesk Revit 2011, and after the simulation results were converted to Green Building Studio gbXML file to be used in ECOTECT, Daylight Autonomy a dynamic simulation and static natural lighting simulation the existing method of calculating daylight factors were deduced through Ecotect Analysis 2011. In conclusion, exiting standard model was found in such a condition that the daylight factors for both type A and type B were above 5% the proper standard value, and required improvement. In case light shelf the natural lighting system was attached, the daylight factor was improved to proper standard value for type A, and also was improved above existing facility for type B.

Classification and Prioritizing the Importance of the Facility and Program for Green Care Introduction (그린케어(Green Care) 도입을 위한 시설과 프로그램 유형분류 및 중요도 분석)

  • Choi, Young-Wan;Kim, Young-Joo
    • Journal of Korean Society of Rural Planning
    • /
    • v.25 no.4
    • /
    • pp.77-86
    • /
    • 2019
  • The purpose of this study is to survey and analyze the operating state and characteristics of domestic and foreign green care, prioritize the facilities and programs for green care introduction through expert survey of importance, and thereby to provide a basic material for introducing green care in facilities in Rural Development Project districts, including domestic rural experience facilities. Domestic and foreign literature was analyzed in order to classify the necessary facilities programs, of green care, and the analysis results were modified and supplemented through Expert Delphi Survey. Based on the results, AHP based importance survey was conducted. In terms of the facilities and programs for green care introduction, necessary facilities (H/W) were categorized into four types (accommodation facility, resting facility, experience facility, therapy facility) and S/W programs into three types (learning experience type, therapy type, and care type). To verify the reliability of the AHP based importance survey, Consistency Index (C.I.) was analyzed. As a result, the C.I. value of nine respondents ranged from 0.000 to 0.083 so that the survey was found to have high consistency. The importance of S/W programs was 0.627, and that of H/W facilities was 0.373. For green care introduction, programs were found to be more important. Regarding the categories of necessary facilities, therapy facility had the highest value, or 0.348; experience facility 0.253; accommodation facility 0.211; resting facility 0.188. Therefore, therapy facility and experience facility were found to be important. In case of S/W programs, therapy type had the highest value, or 0.499, and learning experience type (0.255) and care type (0.246) were similarly important. Generally, the categories that had high importance values tended to show a remarkable difference in importance of their sub categories. In particular, facilities or therapy programs using natural ecology and forests were found to be highly important. In conclusion, it is required to actively review the introduction of active programs using resources, such as existing experience facilities and accommodation facilities and villages forests, and programs making the body and soul comfortable, such as natural ecology experience, Green Shower, and horticulture activity.

Application of Disaster Information Classification System for Disaster Management (시설물 재해관리를 위한 재해정보분류체계 구성 방안)

  • Kang Leen-Seok;Park Seo-Young;Moon Hyoun-Seok
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.335-342
    • /
    • 2006
  • Disaster management system should be built for minimizing damage factor that affects to construction facility from natural disaster. It could be classified by three categories such as disaster prevention, damage survey and recovery phases. For an integrated disaster management system, a disaster information classification system(DICS) is necessary for the reasonable disaster information management. This study suggests an integrated DICS that includes disaster type classification, facility type classification and information type classification for disaster management service. The applicability of suggested DICS is verified by railway facility and the research result could be used as a basic information system for national disaster management system.

Experimental investigation of the behaviour of a steel sub-frame under a natural fire

  • Santiago, Aldina;Simoes da Silva, Luis;Vaz, Gilberto;Vila Real, Paulo;Lopes, Antonio Gameiro
    • Steel and Composite Structures
    • /
    • v.8 no.3
    • /
    • pp.243-264
    • /
    • 2008
  • This paper details a testing facility ("NATURAL FIRE FACILITY") that allows closely-controlled experimental testing on full-scale sub-frames while reproducing the spatially transient temperature conditions measured in real fires. Using this test facility, an experimental investigation of six steel sub-frames under a natural fire was carried out at the Department of Civil Engineering of the University of Coimbra. The main objective of these tests was to provide insight into the influence of these connection types on the behaviour of steel sub-structures under fire. The experimental layout is defined by two thermally insulated HEA300 columns and an unprotected IPE300 beam with 5.7 m span, supporting a composite concrete slab. Beam-to-column connections are representative of the most common joint type used on buildings: welded joints and extended, flush and partial depth plate. Finally, the available results are presented and discussed: evolution of the steel temperature; development of displacements and local deformations and failure modes on the joints zone.

EXPERIMENTS ON THE PERFORMANCE SENSITIVITY OF THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF AN ADVANCED INTEGRAL TYPE REACTOR

  • Park, Hyun-Sik;Choi, Ki-Yong;Choi, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.53-62
    • /
    • 2009
  • A set of experiments has been conducted on the performance sensitivity of the passive residual heat removal system (PRHRS) for an advanced integral type reactor, SMART, by using a high temperature and high pressure thermal-hydraulic test facility, the VISTA facility. In this paper the effects of the opening delay of the PRHRS bypass valves and the closing delay of the secondary system isolation valves, and the initial water level and the initial pressure of the compensating tank (CT) are investigated. During the reference test a stable flow occurs in a natural circulation loop that is composed of a steam generator secondary side, a secondary system, and a PRHRS; this is ascertained by a repetition test. When the PRHRS bypass valves are operated 10 seconds later than the secondary system isolation valves, the primary system is not properly cooled. When the secondary system isolation valves are operated 10 or 30 seconds later than the PRHRS bypass valves, the primary system is effectively cooled but the inventory of the PRHRS CT is drained earlier. As the initial water level of the CT is lowered to 16% of the full water level, the water is quickly drained and then nitrogen gas is introduced into the PRHRS, resulting in the deterioration of the PRHRS performance. When the initial pressure of the PRHRS is at 0.1MPa, the natural circulation is not performed properly. When the initial pressures of the PRHRS are 2.5 or 3.5 MPa, they show better performance than did the reference test.

Scale Down Design on Experiment Facility of the Water/Steam Receiver for Solar Power Tower (타워형 태양열 흡수기의 열전달 특성 실험장치에 관한 연구)

  • Seo, Ho-Young;Kim, Jong-Kyu;Kang, Yong-Heack;Kim, Yong-Chan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.676-679
    • /
    • 2007
  • This paper describes an experiment facility to measure the circulation characteristics of a water/steam receiver at various heat fluxes. The natural circulation type receiver was considered in this study. The experiment facility was designed to satisfy circulation balance with an appropriate scale down. As a result, riser tube inner diameter was 7.4 mm and water circulation was 0.319 kg/s. Downcomer tube inner diameter by circulation balance was 9.52 mm and the quality was from 0 to 0.23.

  • PDF

A Study Identifying Improved Building Height Regulations for Managing Natural Landscape in Collective Facility Districts in and around National Parks (국립공원 집단시설지구 자연경관관리를 위한 층고규제 합리화 방안)

  • Lee, Gwan-Gyu
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.5
    • /
    • pp.48-56
    • /
    • 2011
  • The objective of this study is to develop quantitative criteria for setting reasonable standards and regulations for building heights in collective facility districts inside national parks or those connected to their borders. Heights of all building sin collective facility districts were simulated in order to determine heights of ridge lines of sight passing the upper parts of buildings from a main view point. Where a facility's zone is located at the inside or boundary of inland mountainous national parks, and there are coastal type national parks with mountains in the background, the study recommended assigning the maximum allowable height of a building as 8.82m if national park authorities intend to preserve the ridges at three-tenths the height of a mountain. It amounts to 3 or 3.5 stories when it is converted into the number of floors. It is desirable to apply this standard to accommodations like a hotel except lodge or cottage as the maximum allowable height of a building. Nevertheless, when there aren't back mountainous areas among coastal-type national parks, there is a need for applying a separate standard. If an equal and uniform standard is applied to all collective facility districts, it becomes difficult to address local differences when managing landscape. There must be flexibility when applying a standard, depending on variables such as location of view points, differences in the methods of selection of view points, and differences in view angles, etc. Thus, there is a need for different landscape management strategies that address the unique natural environment of different zones.

SBLOCA AND LOFW EXPERIMENTS IN A SCALED-DOWN IET FACILITY OF REX-10 REACTOR

  • Lee, Yeon-Gun;Park, Il-Woong;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.45 no.3
    • /
    • pp.347-360
    • /
    • 2013
  • This paper presents an experimental investigation of the small-break loss-of-coolant accident (SBLOCA) and the loss-of-feedwater accident (LOFW) in a scaled integral test facility of REX-10. REX-10 is a small integral-type PWR in which the coolant flow is driven by natural circulation, and the RCS is pressurized by the steam-gas pressurizer. The postulated accidents of REX-10 include the system depressurization initiated by the break of a nitrogen injection line connected to the steam-gas pressurizer and the complete loss of normal feedwater flow by the malfunction of control systems. The integral effect tests on SBLOCA and LOFW are conducted at the REX-10 Test Facility (RTF), a full-height full-pressure facility with reduced power by 1/50. The SBLOCA experiment is initiated by opening a flow passage out of the pressurizer vessel, and the LOFW experiment begins with the termination of the feedwater supply into the helical-coil steam generator. The experimental results reveal that the RTF can assure sufficient cooldown capability with the simulated PRHRS flow during these DBAs. In particular, the RTF exhibits faster pressurization during the LOFW test when employing the steam-gas pressurizer than the steam pressurizer. This experimental study can provide unique data to validate the thermal-hydraulic analysis code for REX-10.