• Title/Summary/Keyword: Natural Tooth

Search Result 300, Processing Time 0.025 seconds

Clinical Appliance of Konus Telescope Denture and Bar-Retained Overdenture on Partially Edenturous Patient (Bar attachment와 Konus telescope를 이용한 부분 무치악 환자의 수복)

  • Choi, Sung-Ho;Shim, Jun-Sung;Lee, Ho-Yong;Lee, Keun-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.2
    • /
    • pp.119-126
    • /
    • 2002
  • The purpose of this study was to restorate a patient who has a few remaining teeth with #15,23,24 supported Konus telescope denture in Maxillar and #44,43,33,34 supported Dolder bar retained overdenture in Mandible. Konus telescope and bar retained overdenture was taken better results in retention, support, stability compair with regular Removable partial denture. In Removable partial denture, the change of remaining teeth and edentulous ridge is natural. But Konus telescope and bar retained overdenture is a little effected in this change, so it is possiblble in long-term use. In cosider of patient's medical history and the possibility of additional tooth loss, Konus telescope denture can be easily repaired. Compaired with Konus telescope and bar retained overdenture showed high stability and easy cleansing because of rigid support, cross - arch splinting, and simple design. In delivery, patient had a difficulty with removal of denture and plaque control, but showed better condition, good oral hygienic care. Patient satisfied with denture functionally and esthetically. This study showed Konus telescope and bar retained overdenture was effective for treatment of patient remaing a few teeth in function, esthetic and psycologic satisfaction.

Use of a gesture user interface as a touchless image navigation system in dental surgery: Case series report

  • Rosa, Guillermo M.;Elizondo, Maria L.
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.155-160
    • /
    • 2014
  • Purpose: The purposes of this study were to develop a workstation computer that allowed intraoperative touchless control of diagnostic and surgical images by a surgeon, and to report the preliminary experience with the use of the system in a series of cases in which dental surgery was performed. Materials and Methods: A custom workstation with a new motion sensing input device (Leap Motion) was set up in order to use a natural user interface (NUI) to manipulate the imaging software by hand gestures. The system allowed intraoperative touchless control of the surgical images. Results: For the first time in the literature, an NUI system was used for a pilot study during 11 dental surgery procedures including tooth extractions, dental implant placements, and guided bone regeneration. No complications were reported. The system performed very well and was very useful. Conclusion: The proposed system fulfilled the objective of providing touchless access and control of the system of images and a three-dimensional surgical plan, thus allowing the maintenance of sterile conditions. The interaction between surgical staff, under sterile conditions, and computer equipment has been a key issue. The solution with an NUI with touchless control of the images seems to be closer to an ideal. The cost of the sensor system is quite low; this could facilitate its incorporation into the practice of routine dental surgery. This technology has enormous potential in dental surgery and other healthcare specialties.

Study on the Static and Dynamic Structural Analysis Procedure of Excavators (굴삭기의 정적/동적 강도 해석법에 대한 연구)

  • Choung, Joon-Mo;Kim, Gyu-Sung;Jang, Young-Sik;Choe, Ick-Hung;Heo, Min-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.537-543
    • /
    • 2003
  • This paper presents the improved procedure to assess static and dynamic strength of crawler type excavators. A fully integrated model including front attachment and chassis was prepared for structural analysis. In this paper, two types of loading input methods were investigated and the method imposing digging force directly on bucket tooth was more convenient than imposing cylinder reaction force on cylinder pin even if the two methods showed no discrepancy in analysis results. Static strength analysis was carried out for eight analysis scenarios based on two extreme digging positions, maximum digging reach position and maximum digging force positions. The results from static strength analysis were compared with measured stresses, cylinder pressures and digging forces and showed a good quantitative agreement with measured data. Dynamic strength analysis was carried out for simple reciprocation of boom cylinders. It was recognized that the effect of compressive stiffness of hydraulic oil was very important for dynamic structural behavior. The results from dynamic strength analysis including hydraulic oil stiffness were also compared with measured acceleration data and showed a qualitative agreement with measured data.

  • PDF

Optimization of Sugar Replacement with Date Syrup in Prebiotic Chocolate Milk Using Response Surface Methodology

  • Kazemalilou, Sahar;Alizadeh, Ainaz
    • Food Science of Animal Resources
    • /
    • v.37 no.3
    • /
    • pp.449-455
    • /
    • 2017
  • Chocolate milk is one of the most commonly used non-fermentative dairy products, which, due to high level of sucrose, could lead to diabetes and tooth decay among children. Therefore, it is important to replace sucrose with other types of sweeteners, especially, natural ones. In this research, response surface methodology (RSM) was used to optimize the ingredients formulation of prebiotic chocolate milk, date syrup as sweetener (4-10%w/w), inulin as prebiotic texturizer (0-0.5%w/w) and carrageenan as thickening agent (0-0.04%w/w) in the formulation of chocolate milk. The fitted models to predict the variables of selected responses such as pH, viscosity, total solid, sedimentation and overall acceptability of chocolate milk showed a high coefficient of determination. The independent effect of carrageenan was the most effective parameter which led to pH and sedimentation decrease but increased viscosity. Moreover, in most treatments, date syrup and inulin variables had significant effects which had a mutual impact. Optimization of the variables, based on the responses surface 3D plots showed that the sample containing 0.48% (w/w) of inulin, 0.04% (w/w) of carrageenan, and 10% of date syrup was selected as the optimum condition.

What would we meet for the implant dentistry: A Case Report (임플란트를 하면서 만나게 되는 문제들: 증례보고)

  • Lee, Jung-Sam
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.49-67
    • /
    • 2015
  • Since the implant became the important treatment modality in dentistry, the research and clinical effort to mimic natural tooth appearance have been pursued. While the rehabilitation of mastication and occlusal appearance was focused in the past, more esthetic and functional restoration was preferred recently. To fulfill this demand, the clinicians should consider the axial contour, papilla space, subgingival appearance, as well as the shape of occlusal surface. In the surgery part, there have been significant advances in the adequate formation of bone and soft tissue through the careful reflection on the surgery time and incision. When the dentist has good knowledge about this aspect and passion for the final product, he or she can acquire better results.

Digital Dentistry; Yesterday, Today, and the Future (디지털 치의학의 과거와 현재 그리고 미래)

  • Kim, Chang Hwan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.25-38
    • /
    • 2015
  • Since its introduction to the dentistry, the CAD/CAM technology has been used over fifteen years. The application of CAD/CAM started from coping fabrication, expanded to the posterior full crown, and anterior restoration manufacture has also become widespread recently. While the development of machine was rapid, the advance of zirconia block was the fastest. Although some differences exist among individuals, the various natural tooth color can be expressed through the zirconia coloring itself without porcelain build up. And the texture characteristics can be reproduced just by CAD design. In this article, the development history of digital dentistry was summarized.

Residual bone height measured by panoramic radiography in older edentulous Korean patients

  • Liang, Xiang Hua;Kim, Young-Mi;Cho, In-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.53-59
    • /
    • 2014
  • PURPOSE. The aim of this study was to obtain statistical data on the residual bone height at different natural tooth positions by panoramic radiography in edentulous Korean patients aged 60-90 years. MATERIALS AND METHODS. The study included the diagnostic panoramic radiographs of 180 randomly selected edentulous patients without systemic diseases affecting bone. The radiographic selection criteria included absence of obvious facial asymmetry, clearly visible anatomic structures, and no surgical and fracture history. The panoramic radiographs of 79 patients met these criteria and were used in the analysis. The same researcher processed all the radiographs by using a standardized method. The height of the residual bone was measured at 18 predetermined sites (7 in the maxilla and 11 in the mandible) on digitized and printed radiographs by using a Digimatic caliper, triangle, and ruler. Gender- and age-related differences were statistically analyzed by using the t-test and rank-sum test (${\alpha}=0.05$). RESULTS. The maxillary residual bone height did not show significant gender-related differences, but male patients had significantly higher residual bone in the mandible(P<.05). No significant height differences at the measured sites were noted among the 60s, 70s, and 80s age groups. CONCLUSION. Dentists should pay greater attention to older female edentulous patients because they are more prone to rapid residual bone resorption. Residual bone resorption may not be affected by age.

Full Mouth Rehabilitation of a Patient with Bite Collapse in the Molar Area Using Removable Partial Denture and Dental Implant Prosthetics

  • Hong, Jun-Won;Seo, Jae-Min;Seong, Dong-Hwan;Song, Gwang-Yeop;Park, Ju-Mi;Ahn, Seung-Geun
    • Journal of Korean Dental Science
    • /
    • v.3 no.2
    • /
    • pp.40-49
    • /
    • 2010
  • Dental clinicians often encounter cases wherein the patient's lost molar area was neglected and left untreated for an extended period of time, thereby causing the extrusion of opposite molars and occlusal disharmony as well as occlusion in the anterior teeth and consequently resulting in anterior displacement in the area. Clinicians normally carry out prosthetic treatment via occlusal plane lifting when such becomes absolutely necessary due to the lack of sufficient space needed for prosthetic therapy aimed at proper anterior and lateral induction. In this case report, we examined occlusal disharmony and VDO loss in a patient who had lost his molars and had not received prosthetic treatment for an extended period of time. We treated the maxillary area with dental implant prosthetics and Kennedy Class I RPD and the mandibular area with residual natural tooth-based implant placement and dental implant prosthetics. The patient reported treatment outcomes that were deemed satisfactory both functionally and aesthetically.

  • PDF

A STUDY ON ORAL SENSORY FUNCTION IN THE IMPLANT-SUPPORTED PROSTHESES WEARERS (치과 임플랜트 보철 장착자의 구강 감각 기능에 관한 연구)

  • Jang, Kyoung-Soo;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.215-232
    • /
    • 1991
  • In this study, oral sensory function in the osseointegrated root form implant-supported prostheses wearers was estimated by measuring occlusal tactile perception threshold of thickness and sensibility threshold against lateral static loading, and comparing with normal dentition subjects and complete denture wearers group. Osseointegrated root form implants seemed to be restored in the sensation to some extent, and so, dental implants restored edentulous patients in a wide meaning. Conclusions were summarized as following. 1. Occlusal tactile perception threshold of thickness was highest in complete denture wearers group, following by implant-supported prostheses wearers group, normal dentition subjects group. 2. In the implant-supported prostheses wearers group, occlusal tactile perception threshold of opposing artificial teeth case was higher than of opposing natural or opposing implantsupported teeth case. 3. Sensibility threshold against lateral loading of complete denture wearers and implantsupported prostheses wearers group was higher than that of normal dentition subject group. 4. In the implant-supported prostheses group, sensibility threshold against lateral loading was not significantly different between upper and lower jaws. 5. In occlusal tactile perception threshold of thickness and sensibility threshold against lateral loading test, there was no regularity among values of each tooth, and no significant difference between anterior and posterior teeth as well.

  • PDF

A Study on the Dynamic Stability of Heavy Press Considering Rotational Speed (회전 속도를 고려한 대형 프레스의 동적 안정성에 관한 연구)

  • Shin, Min Jae;Kim, Chae Sil;Keum, Chang Min;Kim, Jae Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.8
    • /
    • pp.623-628
    • /
    • 2016
  • This article describes the determination of the dynamic stability for a heavy press, particularly considering rotational speed. A finite element model of the driving parts for the heavy press was generated. We also applied boundary conditions and dynamic loads considering the driving conditions. Modal analysis was conducted using the finite element construction model. Therefore, no resonance was identified with the comparison between the results of the modal analysis and vibration excitation frequency by the gear tooth. In addition, the stress distribution of the driving parts for press was determined using transient analysis. As compared to the yield strength of the material, the dynamic stability the heavy press was confirmed.