• 제목/요약/키워드: Natural Standard

검색결과 1,761건 처리시간 0.026초

의료영상의 JPEG 압축을 위한 양자화 테이블과 허프만 테이블 설계 (Design of Quantization Tables and Huffman Tables for JPEG Compression of Medical Images)

  • 양시령;정제창;박상규
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권6호
    • /
    • pp.453-456
    • /
    • 2004
  • Due to the bandwidth and storage limitations medical images are needed to be compressed before transmission and storage. DICOM (Digital Imaging and Communications in Medicine) specification, which is the medical images standard, provides a mechanism for supporting the use of JPEG still image compression standard. In this paper, we explain a method for compressing medical images by PEG standard and propose two methods for JPEG compression. First, because medical images differ from natural images in optical feature, we propose a method to design adaptively the quantization table using spectrum analysis. Second, because medical images have higher pixel depth than natural images do, we propose a method to design Huffman table which considers the probability distribution feature of symbols. Simulation results show the improved performance compared to the quantization table and the adjusted Huffman table of JPEG standard.

Determination of Higenamine in the Commercial Aconiti Tuber and Its Pharmaceutical Preparations

  • Hahn, Young-Hee;Cheong, Kyo-Soon;Paik, Seung-Whan;YunChoi, Hye-Sook
    • 생약학회지
    • /
    • 제17권1호
    • /
    • pp.1-6
    • /
    • 1986
  • A cardiac principle of Aconiti tuber, higenamine was analyzed with a differential pluse voltammetry employing a glassy carbon electrode. The peak potentials for the oxidation of higenamine were varied depending on the pH of the media. Higenamine at the concentration of $5.4{\times}10^{-7}M$ (0.146ppm) was easily determined using a pH 7.0 phosphate buffer. The amounts of higenamine in the crude Aconiti tuber and tablets containing A. tuber were determined by a standard addition method after extracting with methanol, partitioning with a mixture of $H_2O$ and $CHCl_3$, and freeze-drying the aqueous layer.

  • PDF

판형교의 고유진동수 특성에 관한 연구 (A Study on the Characteristic of Natural Frequencies of Railway Plate Girder Bridges)

  • 오지택;박문석;최진유
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.304-309
    • /
    • 2001
  • Natural frequencies are studied for dynamic analysis of plate girder bridges which are made up about 34% in the existing railway bridges in Korea. In this study, standard plate girder bridges designed by L-22, a standard load type of the railway specification in Korea, are modeled for finite element method analysis. SAP2000n, a commercial finite element method analysis tool, is used for structural analyses and evaluations. Span lengths of Plate girders have 7 types : 6m, 9m, 12m, 15m, 22m, 24m, and 30m. Natural frequencies are considered in mass rations and span lengths and they are compared with a recommendation of UIC 776-1R for alterations, from now on, in train conditions of operation. For changes of natural frequencies in plate girders by damages of structures, Parameter studies are accomplished.

  • PDF

완충재 유무에 따른 표준중량충격원에 의한 콘크리트 바닥 구조의 소음 및 진동 특성 (Noise and Vibration Characteristics of Concrete Floor Structures Using Resilient Materials Driven by Standard Heavy Impact Source)

  • 송희수;전진용;서상호
    • 한국소음진동공학회논문집
    • /
    • 제14권8호
    • /
    • pp.661-667
    • /
    • 2004
  • The characteristics of noise and vibration by a heavy impact source was studied. The triggering method was used for increasing the reliability and stability to measure the level of sound pressure. sound intensity and vibration acceleration. A simple finite element model and a rigid body analysis method were suggested to calculate the natural frequencies of the multi-layer floor system. The results show that the resilient materials decrease the natural frequency of the reinforced concrete slab, make a resonance with dominant driving frequency in the low frequency region, and increase the vibration and noise level. A simple finite element model and rigid body models was suggested to calculate the natural frequencies of the floor systems.

공용중인 PSC 거더 교량의 진동사용성 평가 (Vibration Serviceability Evaluation of Prestressed Concrete Girder Bridge)

  • 박선준;강성후;김보환;김승
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.781-786
    • /
    • 2009
  • The thesis shows that we gauged vibration of vehicular load regarding WPC girder bridge and researched into dynamic characteristics(natural frequency, vibration acceleration) of WPC girder bridge. By the basic of that, we researched on vibration serviceability by looking over and being compared to vibration criteria we had before. In the thesis, the gauged vibration made an analysis of vertical acceleration through FFT method and evaluated vibration serviceability about vibration sense the body feels by means of the standard of ISO assessment standard and Meister assessment standard by referring to analysis data. This research on bridge is WPC girder bridge of 90m span, width of 5.5m, and the experiment was gauged by a fluent which is right way and inverse way about dump truck of gross 270kN. Acceleration was located in the middle of 1st span, 2nd span, 3rd span. As a result of appraisal standard of Meister, the vibrations of the bridge have distributed between "Level C, Strongly Perceptible" and "Level B, Disturbing". Also the vibration can be attacked with unpleasant feeling. As a result of appraisal standard of ISO, from vibration influence didn't come to 60s, and reduced comfort boundary in part of most rigorous standard that such a case didn't happen.

  • PDF

공용중인 PSC 거더 교량의 진동사용성 평가 (Vibration Serviceability Evaluation of Prestressed Concrete Girder Bridge)

  • 강성후;김보환;박선준;김승
    • 한국소음진동공학회논문집
    • /
    • 제20권4호
    • /
    • pp.331-337
    • /
    • 2010
  • The thesis shows that we gauged vibration of vehicular load regarding WPC girder bridge and researched into dynamic characteristics(natural frequency, vibration acceleration) of WPC girder bridge. By the basic of that, we researched on vibration serviceability by looking over and being compared to vibration criteria we had before. In the thesis, the gauged vibration made an analysis of vertical acceleration through FFT method and evaluated vibration serviceability about vibration sense the body feels by means of the standard of ISO assessment standard and Meister assessment standard by referring to analysis data. This research on bridge is WPC girder bridge of 90 m span, width of 5.5 m, and the experiment was gauged by a fluent which is right way and inverse way about dump truck of gross 270 kN. Acceleration was located in the middle of 1st span, 2nd span, 3rd span. As a result of appraisal standard of Meister, the vibrations of the bridge have distributed between "level C, strongly perceptible" and "level B, disturbing". Also the vibration can be attacked with unpleasant feeling. As a result of appraisal standard of ISO, from vibration influence didn't come to 60s, and reduced comfort boundary in part of most rigorous standard that such a case didn't happen.

Environmental Assessment of Blasting Noise and Vibration in Residential Area

  • Kim, Jang-Ho;Seo, Seok-Jin;Son, Joo-Young;Sung, Han-Ki;Park, Dong-Hoon;Kim, Suck-Taek;Park, Won-Chul
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제3권1호
    • /
    • pp.75-80
    • /
    • 1999
  • An investigation of noise and vibration caused by the reclamation of the foreshore around J village resulted in noise measurements of 56-84 dB at the first point, 62-81 dB at the second point, and 68-78 dB at the third point. These measurements were higher than the standard level of environmental noise that is 55 dB at noon and 45 dB at night. The vibration measurements were 61-83 dB at the first point, 63-88 dB at the second point, and 58-77 dB at the third point. These measurements were also higher than the standard level of environmental vibration that is 60 dB at noon and 54 dB at night. The measurements of scattering dust were 80 $\mu\textrm{g}$/$\textrm{m}^3$ at the first point, 120 $\mu\textrm{g}$/$\textrm{m}^3$ at the second point, and 169 $\mu\textrm{g}$/$\textrm{m}^3$ at the third point. These measurements were lower than the standard level of environmental dust that is 300 $\mu\textrm{g}$/$\textrm{m}^3$/day. Although the maximum vibration level was higher than the standard level of environmental vibration, it had no influence on the construction.

  • PDF

수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안 (Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-Horizontal Area Ratio)

  • 우성식;이상현;정란;이정우;조승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.653-658
    • /
    • 2008
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the Case01 to 19, the standard deviation($s_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the Case21 to 61, the standard deviation ($s_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

  • PDF

수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안 (Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-horizontal Area Ratio)

  • 우성식;정란;이정우
    • 한국소음진동공학회논문집
    • /
    • 제19권2호
    • /
    • pp.119-126
    • /
    • 2009
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the case01 to 19, the standard deviation($S_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the case21 to 61, the standard deviation($S_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.