• 제목/요약/키워드: Natural Insulation

검색결과 177건 처리시간 0.026초

극저온용 폴리우레탄 폼에 미치는 케블라 펄프의 영향 (The Effects of Kevlar Pulp on Polyurethane Foam for Cryogenic Temperature)

  • 오종호;배진호;이제명
    • 대한조선학회논문집
    • /
    • 제55권6호
    • /
    • pp.514-520
    • /
    • 2018
  • Polyurethane foam has excellent mechanical strength and insulation performance, and has been adopted as an insulation material for $-163^{\circ}C$ liquefied natural gas carrier. In this study, Kevlar Polyurethane Foams(K-PUF) were synthesized by adding Kevlar pulp with excellent mechanical strength for the purpose of improving the performance of existing polyurethane foam. Since polyurethane foam has mechanical performance depending on the proportions of Kevlar pulp added, the mechanical strength of the K-PUF with ratios of fiber0.2wt.%, 0.4wt.%, 0.6wt.%, 0.8wt.% and 1.0wt.%) was evaluated. The compression tests were performed on the 4 different temperatures($20^{\circ}C$, $-50^{\circ}C$, $-110^{\circ}C$ and $-163^{\circ}C$) in consideration of the environmental characteristics as a cryogenic insulation used in LNG carrier. Besides, the effects of the fiber addition on polyurethane foam with closed cell structure were evaluated in a phenomenological approach through SEM analysis. All the results were compared to Neat-polyurethane foam. As a results, 0.8wt.% K-PUF showed the improved mechanical strength, and the addition of Kevlar pulp in a certain ratio improves the mechanical performance by enhancing the compression resistance.

균질화기법에 기초한 유도전동기 권선 다발의 등가물성 유도 (Derivation of Equivalent Material Properties of Induction Motor Windings Based on Homogenization Method)

  • 배징도;고우식;조진래
    • 대한기계학회논문집A
    • /
    • 제29권4호
    • /
    • pp.518-525
    • /
    • 2005
  • The electromagnetic noise generates when natural frequencies of a stator core with wingdings and frame coincide with or approach natural frequencies of the magnetic motive force. In order to suppress such noise, the estimation of natural frequencies of the motor is important at the design stage. However, the natural frequency analysis is not so easy because motor stator is in the laminated plate structure and windings are composed of wires, insulation sheets and vanishs. Thus the accurate prediction of the equivalent material properties of windings becomes an essential task. In this paper, we derive the equivalent material properties using homogenization methods.

가정용 연료전지 $1Nm^3/hr$급 천연가스 연료처리장치의 운전 특성 (Operating Characteristics of $1Nm^3/hr$ class Natural Gas Fuel Processor for Residential Fuel cells)

  • 신장식;신석재;이승영;양혜경;성봉현;김두훈;박종원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.19-22
    • /
    • 2007
  • In this study, we investigated operating characteristics of natural gas fuel processor for polymer electrolyte membrane fuel cells (PEMFCs). The fuel processor consists of a natural gas reformer, a water-gas shift reactor, a heat-exchanger and a burner, in which the overall integrated volume is exactly(exceptionally) small, namely, about 10L except outer insulation. The producted hydrogen is $1Nm^3/hr$ and the maximum thermal efficiency is ${\sim}76%$(low heating value) at full operating load. A compact and highly efficient $1Nm^3/hr$ class natural gas fuel processor was developed at UNISON is an advantage for application in residential PEMFCs co-generation systems.

  • PDF

복합화력발전의 가스연료 공급계통에 대한 위험도 평가 기법 연구 (I) : API RBI 절차에 기반한 위험도 평가 (Risk Assessment Technique for Gas Fuel Supply System of Combined Cycle Power Plants (I) : Based on API RBI Procedures)

  • 송정수;유종민;한승연;최정우;윤기봉
    • 에너지공학
    • /
    • 제27권2호
    • /
    • pp.1-13
    • /
    • 2018
  • 미세먼지 저감 및 에너지원 변환에 대한 정책 추진에 따라 천연가스를 연료로 하는 발전의 비중이 확대되고 있다. 복합화력발전 플랜트, 열병합발전 플랜트 등에서 천연가스 연료공급계통이 가스가 가열된 상태에서 고압으로 운용되고 있으므로, 누출사고를 예방하여 화재 및 폭발에 의해 사고를 방지하여야 한다. 본 연구에서는 API RP 581 RBI 코드를 기반으로 복합화력발전 플랜트의 천연가스 연료공급계통을 대상으로 위험도 평가를 수행하였다. API RBI 코드의 적용을 위해 평가 대상 계통의 라인 및 세그먼트를 구분하였다. 파손확률과 파손피해 산출을 위해 운전 데이터 및 입력 정보를 분석하였다. 설치 초기 시점 및 운전시간 경과에 따른 위험도 평가 결과 추이를 분석하였다. 코드 기반 평가 시 가스연료 공급계통은 두께 감육, 외부 손상, 기계적 피로 손상기구의 영향이 주로 반영되었다. 운전 시간이 경과함에 따라 단열재 하부 부식(CUI, Corrosion Under Insulation) 등에 의한 외부손상이 위험도를 상승시키는 원인으로 예상되었다.

안트라사이트 치환율에 따른 경소마그네시아 경화체의 단열특성 (Heat Insulation Properties of Lightweight Magnesia Matrix According to Mixing Ratio of Anthracite)

  • 편수정;권오한;경인수;이동훈;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.113-114
    • /
    • 2017
  • Recently, Subway workers have died from lung cancer. According to the Epidemiological Survey of the Welfare Corporation Institute of Pulmonary Disease of the Welfare Corporation, the family members applied for industrial accidents. The radon concentration in the subway work area was found to exceed 10 times the recommended standard value of 148 becquerels (Bq/㎥) in domestic multipurpose facilities. In addition, as a result of the national indoor radon concentration survey conducted by the Ministry of Environment in 2010 and 2013, housing was found to be over 100 becquerels (Bq/㎥) in 41% of the surveyed subjects. In addition, it was found that in 2012, 16.3% of villages exceeded the radon standard value in the survey on natural radioactive materials containing groundwater.

  • PDF

커튼월의 단열 향상 및 결로 방지를 위한 통기구조 적용방안 연구 (Application of Ventilated Cavity for Enhancing Insulation and Preventing Condensation of Curtain-wall System)

  • 이선우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.21-28
    • /
    • 2017
  • Curtain-wall systems have been widely applied to buildings because of their lightweight and constructability characteristics. However, as curtain-wall systems include many building materials, vapor barriers can become damaged and condensation can occur. Due to the material properties of stone curtain-walls, the external appearance and structure of a building could be damaged and the insulating performance of the curtain-wall could be worse. Natural ventilation using an air cavity in a curtain-wall is expected to be effective for the prevention of condensation in inner walls and for the reduction of building cooling energy use in the summer. The purpose of this experimental study is to analyze the influence of a ventilated cavity on the insulating performance of a curtain-wall and the ventilated cavity depth and ratio of top opening needed to prevent condensation in a curtain-wall.

사지말초부의 노출과 보온이 인체의 체온조절에 미치는 영향 (Effects of Exposure and Insulation of the Extremities on the Human Thermoregulation)

  • 정운선;등창심실
    • 한국의류학회지
    • /
    • 제15권4호
    • /
    • pp.447-451
    • /
    • 1991
  • Effects of insulation after exposure of the extremities on the temperature regulation in clothed men were studied. Experiment was carried out with six males in a climatic chamber fixed at $10^{\circ}C$, $55\%$ R.H. treated with Type A (face only was exposed) and Type B (face and half of the extremities were exposed). Mean skin temperature fell greater in Type B due to intense vasoconstriction than in Type A. Rectal temperature rose a little in Type B and resumed in Type A without any significant differences in metabolism between two types of clothing. These findings suggest that Type B is more effective in physiological defense to the cold stimuli than Type A at least at $10^{\circ}C$.

  • PDF

고주파 충격에 의한 전자부품 고장 방지 설계 (Designing Electronics for High Frequency Shock)

  • 이종학;강동석;최지호;강영식;이창민
    • 한국소음진동공학회논문집
    • /
    • 제25권10호
    • /
    • pp.700-706
    • /
    • 2015
  • In this study, stability designing electronics mounted on launch vehicle for shock load(low/high frequency band) could be derived. For the low-frequency shock loads, CCA(circuit card assembly) has secured the structural integrity over the best natural frequency techniques. For the high-frequency shock load, the structural integrity could be ensured with applying device such as the insulation pad. When the EAR is applied, insulation effect of part application is good more than whole application.

LNG 화물창 방열재 균열에 따른 액화천연가스의 확산 및 온도 예측을 위한 수치 모델 (Numerical Model of Heat Diffusion and Evaporation by LNG Leakage at Membrane Insulation)

  • 이장현;김윤조;황세윤
    • 한국해양공학회지
    • /
    • 제28권6호
    • /
    • pp.517-526
    • /
    • 2014
  • The leakage of cryogenic LNG through cracks in the insulation membrane of an LNG carrier causes the hull structure to experience a cold spot as a result of the heat transfer from the LNG. The hull structure will become brittle at this cold spot and the evaporated natural gas may potentially lead to a hazard because of its flammability. This paper presents a computational model for the LNG flow and heat diffusion in an LNG insulation panel subject to leakage. The temperature distribution in the insulation panel and the speed of gas diffusion through it are simulated to assess the safety level of an LNG carrier subject that experiences a leak. The behavior of the leaked LNG is modeled using a multiphase flow that considers the mixture of liquid and gas. The simulation model considers the phase change of the LNG, gas-liquid multiphase interactions in the porous media, and accompanying rates of heat transfer. It is assumed that the NO96-GW membrane storage is composed of glass wool and plywood for the numerical simulation. In the numerical simulation, the seepage, heat diffusion, and evaporation of the LNG are investigated. It is found that the diffusion speed of the leakage is very high to accelerate the evaporation of the LNG.

AC Breakdown Voltage and Viscosity of Palm Fatty Acid Ester (PFAE) Oil-based Nanofluids

  • Mohamad, Mohd Safwan;Zainuddin, Hidayat;Ab Ghani, Sharin;Chairul, Imran Sutan
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2333-2341
    • /
    • 2017
  • Mineral oils are commonly used as transformer insulation oils but these oils are obtained from non-renewable and non-sustainable sources, which is highly undesirable. For this reason, natural ester oils are now being used in replacement of mineral oils because of their good biodegradability, high cooling stability, good oxidation stability and excellent insulation performance. Nanotechnology has gained prominence in both academic and industrial fields over the years and it has been shown in previous studies that nanoscale materials are useful for transformers due to their favourable dielectric properties. The objective of this study is to compare the AC breakdown voltage and viscosity of natural ester oil with three types of nanofluids. The natural ester oil-based nanofluids are prepared by mixing palm fatty acid ester (PFAE) oil with three types of nanoparticles at a concentration of 0.01 g/l: (1) $Fe_3O_4$ conductive nanoparticles, (2) $TiO_2$ semi-conductive nanoparticles and (3) $Al_2O_3$ insulating nanoparticles. The AC breakdown voltage of the oil samples is analysed using Weibull statistical analysis and the results reveal that the PFAE oil-based $Fe_3O_4$ nanofluid gives exceptional dielectric performance compared to other oil samples, whereby the AC breakdown voltage increases by 43%. It can be concluded that the PFAE oil-based $Fe_3O_4$ nanofluid is a promising dielectric liquid to substitute mineral oils.