• Title/Summary/Keyword: Natural Insulation

Search Result 177, Processing Time 0.042 seconds

Analysis of the lightning characteristics by the LPATS in KOREA (낙뢰위치 표정시스템(LPATS)에 의한 2004넌 한반도 낙뢰통계 분석결과)

  • Kwak, J.S.;Woo, J.W.;Kweon, D.J.;Kang, Y.W.;Moon, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.606-608
    • /
    • 2005
  • As the overhead transmission lines are exposed to the outdoor weather, the causes of the transmission lines faults are from natural conditions, and among these faults, the outage rate due to lightning is more than 60%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF

A Study on the Directions of Sustainable Architecture for Dwelling Planning (지속가능한 주거건축계획의 방향에 관한 연구)

  • 김성화
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1994.10a
    • /
    • pp.31-38
    • /
    • 1994
  • The purpose of paper is to suggest directions of sustainable Architecture for dwelling planning. It deals with foreign example regading recycling Architecture in the point of using natural reources and energy effectively and minimizing environmental wastes. The methods which can be applied to Korean dwelling planning are as follows : 1) To use the underground space of apartments as pubilc energy-saving facility 2) To use conservatory passive solar systems at south-facing balconies of apartments 3) To flow daylight into the staircase of single-family house 4) To construct compactly doors and windows which have high-level insulation with high insulated walls and ventilation systems 5) To recycle materials such as steel, wood and soil 6) To recycle space according to the change of uses 7) To make users participate actively when we plan for dwelling.

  • PDF

A Study on the Directions of Sustainable Architecture for Dwelling Planning (지속가능한 주거건축계획의 방향에 관한 연구 - 문헌 고찰을 통한 사례연구를 중심으로 -)

  • 김성화
    • Journal of the Korean housing association
    • /
    • v.6 no.2
    • /
    • pp.77-86
    • /
    • 1995
  • The purpose of paper is to suggest directions of sustainable Architecture for dwelling planning. It deals with foreign examples regarding recycling Architecture in the point of using natural resources and enerty effectively and minimizing environmental wastes. The methods which can be applied to Korean dwelling planning are as follows : 1) To use the underground space of apartments as public energy-saving facility 2) To use conservatory passive solar systems at south-facing balconies of apartments 3) To flow daylight into the staircase fo single-family house 4) To construct compactly doors and windows which have high-level insulation with high insulated walls and ventilation systems 5) To recycle materials such as steel. wood and soil 6) To recycle space according to the change of uses 7) To make users participate actively when we plan for dwelling.

  • PDF

A Protection of Substation Equipment Applying Underbuilt Ground Wire and Guy Wire (Underbuilt Ground Wire와 Guy Wire를 이용한 변전소 기기 보호에 관한 연구)

  • Kim Jae Kwan;Lee Jong Beom;Cho Han Goo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.610-612
    • /
    • 2004
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about $50\%$. Therefore, the insulation design is important to decrease the damage of the facility and to increase the reliability of electric power system. This paper describes the protective method of substation equipments using the Underbuilt Ground Wire and the Guy Wire. This would not only reduce backflashover possibility but also minimize crest and duration of surges entering the substation. EMTP is used to analyze the efficiency of the proposed methods.

  • PDF

Analysis of the lightning characteristics by the Lightning DB in KOREA (낙뢰위치표정시스템의 낙뢰 DB를 이용한 한반도 뇌격 특이특성 분석)

  • Woo, J.W.;Kwak, J.S.;Shim, E.B.;Lee, G.W.;Kim, K.W.;Kim, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1658-1660
    • /
    • 2001
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF

Effective Control of Indoor Air Pollutant using VAV/BPFS (VAV/BPFS를 이용한 실내공기 오염물질의 효율적 제어)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.327-334
    • /
    • 1998
  • The oil crisis of the 1970s and the rise in oil prices motivated people to implement energy conservation strategies. Buildings were fitted with additional Insulation and reduced ventilation rates. The reduction of mechanical and natural ventilation rate led to Increases In Indoor pollutant concentrations which result- ed In Increased health risks from Indoor exposure to pollutants. The variable-air-volume /bypass fitration system/VAV/BPFS) is a variation of the conventional VAV systems, The VAV/BPFS is an electronically controlled system that provides costegectlve thermal comfort and acceptable indoor air quality Under controlled conditions In a chamber, a series experiments were performed to compare the ability of a VAV/BPFS to remove Indoor aerosol concentration and to reduce energy consumption no that ability of conventional VAV system. Results show that the VAV/BPFS Increases the effective ventilation rate and removes indoor air pollutant, and maintains acceptable indoor air Quality without sacrificing energy consumption.

  • PDF

Structural Strength Assessment of Simplified Mark III CS Plate (단순화된 Mark III 방열판의 구조 강도 평가에 관한 연구)

  • Jeong, Han-Koo;Yang, Young-Soon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.539-543
    • /
    • 2011
  • LNG cargo containment system (CCS) has the primary function of ensuring adequate thermal insulation with keeping natural gas below its boiling point. From the viewpoint of structural design, this LNG CCS can be treated as a laminated composite structure showing complex structural responses under the sloshing load which can be defined as a violent behavior of the liquid contents in cargo tanks due to external forced motions. As LNG CCS type, Mark III containment system from TGZ is considered in this paper and then its structural strength assessment is performed based on a simple higher-order shear deformation theory and maximum stress, maximum strain, Tsai-Wu failure criteria developed for laminated composite plates. The assessment is performed to the initial failure of the Mark III CS plate by investigating failure locations and loads.

  • PDF

Development of Real Time Analysis System about Lightning Information (낙뢰정보 실신간 통계분석시스템 개발)

  • Kwak, J.S.;Woo, J.W.;Shim, E.B.;Kim, K.W.;Kim, Y.S.;Lee, S.J.;Lee, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.169-171
    • /
    • 2003
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission tines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the development of real time analysis system about lightning information.

  • PDF

Development of Heal Time Lightning Information System (실시간 낙뢰화면 표시프로그램 개발)

  • Kwak, J.S.;Woo, J.W.;Shim, E.B.;Kim, K.W.;Kim, Y.S.;Lee, S.J.;Lee, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.175-177
    • /
    • 2003
  • Because the overhead transmission lines arc exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the development of real time analysis system about lightning information.

  • PDF

Analysis of the lightning characteristics by LPATS Data during 7 year (LPATS에 의한 7년간의 한반도 뇌격특성분석)

  • Woo, J.W.;Shim, E.B.;Kwak, J.S.;Kweon, D.J.;Moon, J.D.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.509-511
    • /
    • 2003
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF