A Study on Natural Vibration Characteristics of Dome Structure According to Natural Frequency Ratio of Substructure (하부 구조의 고유 진동수비에 따른 돔 구조의 고유 진동 특성에 관한 연구)

  • Park, Kwang-Seob;Kim, Yun-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.75-82
    • /
    • 2018
  • Large space structures exhibit different natural vibration characteristics depending on the aspect ratio of structures such as half-open angle. In addition, since the actual large space structure is mostly supported by the lower structure, it is expected that the natural vibration characteristics of the upper structure and the entire structure will vary depending on the lower structure. Therefore, in this study, the natural vibration characteristics of the dome structure are analyzed according to the natural frequency ratio by controlling the stiffness of the substructure. As the natural frequency of the substructure increases, the natural frequency of the whole structure increases similarly to the natural frequency of the upper structure. Vertical vibration modes dominate at $30^{\circ}$ and $45^{\circ}$, and horizontal vibration modes dominate at $60^{\circ}$ and $90^{\circ}$.

Ratio of predicted and observed natural frequency of finite sand stratum

  • Prathap Kumar, M.T.;Ramesh, H.N.;Raghavendra Rao, M.V.;Raghunandan, M.E.
    • Geomechanics and Engineering
    • /
    • v.1 no.3
    • /
    • pp.219-239
    • /
    • 2009
  • Vertical vibration tests were conducted using model footings of different size and mass resting on the surface of finite sand layer with different height to width ratios and underlain by either rigid concrete base or natural red-earth base. A comparative study of the ratio of predicted and observed natural frequency ratio of the finite sand stratum was made using the calculated values of equivalent stiffness suggested by Gazetas (1983) and Baidya and Muralikrishna (2001). Comparison of results between model footings resting on finite sand stratum underlain by the rigid concrete base and the natural red-earth base showed that, the presence of a finite base of higher rigidity increases the resonant frequency significantly. With increase in H/B ratio beyond 2.0, the influence of both the rigid concrete and natural red-earth base decreases. Increase in the contact area of the footing increases the resonant frequency of the model footings resting on finite sand stratum underlain by both the types of finite bases. Both the predicted and the observed resonant frequency ratio decreases with increase in force rating and height to width ratio for a given series of model footing.

Dynamic Response Property according to Natural Frequency Ratio between Dome Structure and Substructure (상부 돔구조와 하부구조간의 고유진동수비에 따른 동적응답특성)

  • Lee, Young-Rak;Kim, Kwang-Il;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.2
    • /
    • pp.113-120
    • /
    • 2015
  • This study investigate the dynamic response changes of rib dome structure according to property changes of Substructure. Eigenvalue analysis is conducted in first natural frequency of rib dome versus substructure and searched in the dominant mode of horizontal and vertical direction. Resonance frequency by each first natural frequency of the rib dome structure, substructure and total structure is applied for a seismic wave. That is analyzed about maximum displacement response ratio and maximum acceleration response ratio.

Vibration Characteristics of Boxthorn(Lycium chinense Mill) (구기자 가지의 진동 특성)

  • 서정덕
    • Journal of Biosystems Engineering
    • /
    • v.26 no.2
    • /
    • pp.105-114
    • /
    • 2001
  • Modulus of elasticity, modulus of rigidity, damping ratio, and natural frequency of three varieties of boxthorn (Lycium chinense Mill) (Cheongyang #2, Cheongyang gugija, and Cheongyang native) branches were analyzed. Modulus of elasticity and modulus of elasticity and modulus of rigidity of the boxthorn branch was determined using standard formula after simple beam bending and torsion test, respectively, using an universal testing machine. Damping ratio and natural frequency of branches were determined using a system consisted of an accelerometer, a PC equipped with A/D converter, and a software for data analysis. Relationship between the elastic modulus and branch diameter in overall varieties and branch types showed a good correlation (r -0.81). There was, however, no correlation between torsional rigidity and branch diameter. The internal damping results were highly variable and the overall range of the damping ratio of the boxthorn branch was 0.014-0.087, which indicated that the branch was a lightly damped structure. The natural frequency of the boxthorn branch was in the range of 89-363 rad/s for the overall varieties and branch types. A good correlation (r 0.82) existed between the natural frequency and branch diameter in overall varieties and branch type.

  • PDF

A Study on the Effects of Dual Dynamic Vibration Absorber for Damped Vibration System (감쇠진동계에 부착된 복합동흡진기의 효과에 관한 연구)

  • 안찬우;최석창;김동영
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.1039-1048
    • /
    • 1997
  • This paper describes the effects of dual dynamic vibration absorbers attached to a primary vibration system with damping. The efficiency of dual dynamic vibration absorbers was investigated with the height of amplitude ratio at the resonance frequency ratio of the damped vibration system according to mass ratio, natural frequency ratio and damping ratio. The variation of amplitude ratio related to frequency ratio of primary vibration system is verified experimentally and theoretically according to dual dynamic vibration systems using computer program designed to find mutual relationship between two absorbers.

  • PDF

A Study on Optimal Multi-dynamic Absorber of Damped Linear Vibration System under the Harmonic Motion of the Base (기반의 조화운동을 받는 감쇠선형진동계의 최적 복합동흡진기에 관한 연구)

  • 안찬우;김동영;홍도관
    • Journal of KSNVE
    • /
    • v.10 no.2
    • /
    • pp.325-330
    • /
    • 2000
  • A dynamic absorber is used to protect the primary vibration system under the steady-state harmonic disturbance. In a number of cases it appears expedient to install several absorbers of smaller masses instead of one. This may be due to the need of distribute the absorber's response along the construction, restrictions on the absorber's installation. So, we studied characteristics of the primary vibration system for the optimal natural frequency ratio and the optimal damping ratio of serial multi-dynamic absorber. Also we obtained the optimum values of the serial multi-dynamic absorber parameters using computer simulation for the damped primary vibration system. In designing multi-dynamic absorber, we presented for the optimal natural frequency and the optimal damping ratio of multi-dynamic absorbers.

  • PDF

Resonance Frequency of the Natural Convection in the Closure Cavity for the Variable Aspect Ratio (종횡비가 변하는 공동 내 자연대류의 공진주파수)

  • Chun, Kun-Ho;Joo, Kwang-Sup;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.609-614
    • /
    • 2000
  • This numerical study investigate resonance frequency of natural convection for steady state, periodic flow and chaotic flow in two-dimensional direct numerical simulations, differentially heated, vertical cavities having aspect ratios near unity. The enclosure cavity has isothermal and time dependent temperature side walls and adiabatic top/bottom walls. The aspect ratio is 1/3, 1/2, 1, 2, and 3 for the varying Rayleigh number. Resonance frequency for AR=1 has decrease as the aspect ratio and the Rayleigh number are increasing.

  • PDF

A Study on Dynamic Response Property of Latticed Domes according to Natural Frequency Ratio of Substructure (하부구조의 고유진동수비에 따른 래티스돔의 동적응답특성에 관한 연구)

  • Lee, Young-Rak;Seok, Keun-Young;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.3
    • /
    • pp.59-66
    • /
    • 2016
  • This study analyze the dynamic response property of latticed domes according to natural frequency ratio of substructure. Through eigenvalue analysis, it is was confirmed that the half-open angle $30^{\circ}$ and $45^{\circ}$ dominate vibration mode of the vertical direction and the half-open angle $60^{\circ}$ and $90^{\circ}$ dominate vibration mode of the horizontal direction. Through the dynamic response analysis, it is was confirmed that the first frequency about total structure largely appears about the vertical and the horizontal direction regardless of half-open angle.

Study of Wrinkle Effect on Primary Natural Frequency of Nano-resonator (나노 공진기의 1차 고유진동수에 미치는 링클 영향 연구)

  • Yoon, Juil;Kang, Sang-Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.12
    • /
    • pp.1157-1163
    • /
    • 2012
  • Natural frequency of a nano-resonator via nano transfer printing is studied. Through a nano transfer printing, the hybrid metal/polymer membrane may evolve a wrinkle. Natural frequency of a wrinkled hybrid membrane decreases significantly, as the amplitude to wavelength ratio becomes larger. To address the design limit of a hybrid nano resonator, we perform parametric study using finite element analysis. Specifically, we study the effects of the Young's modulus ratio of the metal/polymer membrane, thickness ratio and wrinkle amplitude to wavelength ratio, respectively. The results from the parametric studies can serve as guideline to design hybrid nano resonators.

Wind Turbine Performance for Eigen Value Change of Closed-Loop System for PI-Controller (피치제어기 폐루프 시스템의 고유치 변화에 따른 풍력발전기의 성능)

  • Kim, Jong-Hwa;Moon, Seok-Jun;Shin, Yun-Ho;Won, Moon-Cheol
    • Journal of Wind Energy
    • /
    • v.4 no.2
    • /
    • pp.17-24
    • /
    • 2013
  • Idealized PID-controlled rotor-speed error for blade pitch control of wind turbines responds as a second-order system with natural frequency and damping ratio for closed-loop system. RISO National Laboratory has recommended specific natural frequency(=0.6 rad/s) and damping ratio(=0.7) for 2 MW wind turbine. The baseline controller for 5 MW wind turbine of NREL(National Renewable Energy Laboratory) is designed based on the same values of RISO recommendation. This study investigates the effect of the natural frequency and damping ratio of the controller for NREL 5 MW wind turbine. It is confirmed that RISO recommendation shall be tuned for each wind turbine.