• Title/Summary/Keyword: National standard

Search Result 12,637, Processing Time 0.048 seconds

A High Voltage NMOSFET Fabricated by using a Standard CMOS Logic Process as a Pixel-driving Transistor for the OLED on the Silicon Substrate

  • Lee, Cheon-An;Jin, Sung-Hun;Kwon, Hyuck-In;Cho, Il-Whan;Kong, Ji-Hye;Lee, Chang-Ju;Lee, Myung-Won;Kyung, Jae-Woo;Lee, Jong-Duk;Park, Byung-Gook
    • Journal of Information Display
    • /
    • v.5 no.1
    • /
    • pp.28-33
    • /
    • 2004
  • A high voltage NMOSFET is proposed to drive top emission organic light emitting device (OLED) used in the organic electroluminescent (EL) display on the single crystal silicon substrate. The high voltage NMOSFET can be fabricated by utilizing a simple layout technique with a standard CMOS logic process. It is clearly shown that the maximum supply voltage ($V_{DD}$) required for the pixel-driving transistor could reach 45 V through analytic and experimental methods. The high voltage NMOSFET was fabricated by using a standard 1.5 ${\mu}m$, 5 V CMOS logic process. From the measurements, we confirmed that the high voltage NMOSFET could sustain the excellent saturation characteristic up to 50 V without breakdown phenomena.

An Estimation of the Standard Cost of Project Management of Empowerment Sector in Comprehensive Rural Village Development Project (일반농산어촌개발 지역역량강화사업비의 적정요율 산정)

  • Choi, Young-Wan;Park, Hyun-Yong;Kim, Young-Joo
    • Journal of Korean Society of Rural Planning
    • /
    • v.19 no.3
    • /
    • pp.131-144
    • /
    • 2013
  • The existing standard cost of project management of empowerment sector in general rural development project has problems with standard cost system without considering characteristics of empowerment project and unclear division of works. These problems are a lot of trouble to fulfill the project. Thus, it needs an arrangement of standard cost considering detailed characteristics of project management in the empowerment sector. The contents and results of this study can be summarized as follows. 1) To set accurate standard cost, we carried out three-step processes, such as elicitation of standard works, calculation of workload and determination of standard cost. (1) In an investigation of 30 rural area dividing 8 parts about an workload of empowerment project, an average workload is 1,499 hours. (2) Based on this results, the standard cost is calculated at 15% of project cost in over 600 million won, at 28.75% of project cost in under 500 million won, by standards of empowerment project cost. 2) It set the responsibility management cost to 15% of empowerment project cost considering existing awareness, workload and work professionalism of project management. Based on the results, It suggested the practical use as basis for efficient management of the future empowerment projects. To achieve this, It needs to promote maximizing results on the whole project through the legalization processes including amendment of existing regulations.

Collaborative Study for the Establishment of KFDA Reference Standard for Somatropin (KS 98/674) (재조합 사람성장호르몬(소마트로핀)의 KFDA 표준품(KS 98/674) 설정 연구)

  • Shin, Won;Joung, Jee-Won;Jin, Jae-Ho;Bristow, Adrian F.;Sohn, Yeo-Won
    • YAKHAK HOEJI
    • /
    • v.45 no.2
    • /
    • pp.227-236
    • /
    • 2001
  • The complexity and variability of both the biologicals and the bioassays used to test them led to the use of the reference standard- a sample of the product of defined purity and potency, against which all preparations of that product must be calibrated. In order to prepare and establish KFDA reference standard for recombinant human growth hormone (somatropin), somatropin substance was filled in ampoules in National Institute for Biological Standards and Control (NIBSC). The candidate KFDA reference standard for somatropin (designated as 98/674) was evaluated to determine the suitability of serving as a KFDA reference standard for somatropin by the collaborative study, in which 10 laboratories participated. Physicochemical analysis and in vivo bioassay were performed by direct comparison with the international somatropin standard 88/624. 98/674 was identified as somatropin by SDS-PAGE, IEF, peptide mapping, and HPLC. Determination of somatropin content by SE-HPLC yielded a mean estimate of 2.01 mg somatropin per ampoule. Data from the study also yielded mean values of 0.39 $\pm$ 0.26% for high molecular weight impurities by SE-HPLC and mean values of 2.13 $\pm$ 1.29% for somatropin related proteins by RP-HPLC. Estimates of relative potency by weight gain bioassay in the hypophysectomised rats showed that relative potency of KS 98/674 was 1.07 aganist IS 88/624. Based on the results of the collaborative study, the candidate reference standard for somatropin is suitable to serve as a KFDA reference standard for somatropin.

  • PDF

A Basic Investigation for the new Rail Standard (새로운 레일규격 제정을 위한 기초검토)

  • 정우진;양신추;강윤석
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.467-474
    • /
    • 2001
  • The KNR(Korean National Railroad) is trying to set a new rail standard to back up the speed-up policy of the conventional railways. This work has passably significance since the rail standards used were introduced from Japan without the consideration on our situation. The contact analysis between wheel treads and rail heads, attended with complex calculation and the wear experiments taken long time should be accomplished for the exact investigation to establish a new rail standard. However, this paper just concentrates the structural investigation of the proposed rail standard and the dynamic analysis between trains and rail models with intent to shift the above procedure on the next step.

  • PDF

Computer Based Three Phase Power Analysing System (3상 전력을 기반으로 한 시스템 해석 컴퓨터)

  • Wijesinghe, W.M.S.;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.675-676
    • /
    • 2008
  • The computer based three phase power analysing system has been developed as a traveling standard for onsite power calibration. The system is utilized with digital-to-analog converts which were synchronized each other. Using digital signal processing technique the software has been developed to calculate power parameters. The calibration system is fully traceable to national standard system and, accuracy allows the calibration of industrial power measurement systems.

  • PDF

The evaluation of useful on the additional PET/CT Liver scan (PET/CT 검사에서 Gastrointestinal Cancer 환자의 Liver 추가촬영에 대한 유용성 평가)

  • Park, Se Youn;Lee, Hwa Jin;Lee, Mu Seok;Kim, Jung Uk;Ji, Hye In
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.46-48
    • /
    • 2016
  • Purpose The liver one of the most common site for distant metastasis for a variety of tumor, especially of gastrointestinal origin. the purpose of this study was to analyze image quality between standard scan and additional liver scan. Materials and Methods From September 2015 to February 2016. 152 patients were examined undergo gastrointestinal cancer. 32 patients confirmed liver metastasis analyzed same liver ROI level and check the SNR, SUV and T/N ratio Results The $SNR_{mean}$ of standard was $17.7{\pm}10.3$; addition was $22.3{\pm}9.7$ (p<0.05). In $SUV_{max}$ of standard was $6.7{\pm}2.8$; addition was $7.6{\pm}3.2$ (P<0.05). and the T/N ratio of standard was $2.1{\pm}0.6$; addition was $2.5{\pm}0.8$ (P<0.05). Conclusion The $SNR_{mean}$, $SUV_{max}$ and T/N ratio were higher than those on the first scan (P<0.05). The SNRmean showed the highest change rate among the parameters. A additional liver scan is more favorable for the detection of gastrointestinal cancer patients.

  • PDF

Effects of ANTORIN R-10 on Ovarian Morphology, Follicular Development and Serum Estradiol Level in Immature Wistar Rats (미성숙 Wistar 랫트에서 ANTORIN R-10이 난소형태, 난포발육 및 혈중 호르몬 농도에 미치는 영향)

  • Kang, Eun-Ju;Yoo, Jae-Gyu;Song, Hye-Jin;Song, Seung-Hee;Rho, Gyu-Jin;Choe, Sang-Yong
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.563-567
    • /
    • 2007
  • This study evaluated the effect of ANTORIN R-10(pFSH), a commercially available follicle stimulating hormone on ovarian morphology, on follicular development and serum estradiol levels in rats. Immature female Wistar S/T rats(27 day old; 80-100 g B.wt) maintained under controlled environmental conditions($22{\pm}2^{\circ}C$; 50% humidity; 12 h light/12 h dark cycle) with free access to standard laboratory feed and tap water were utilized. Animals were allowed to acclimatize to the new environment for at least 2 weeks before being included in the experiment. Rats were randomly allotted to 5 groups(Control, SL 0.1AU, SH 0.2AU, TL 0.1AU and TH 0.2AU). ANTORIN R-10 was subcutaneously injected twice daily for 3 days. Twenty hours after hormone treatment, blood was collected to estimate the serum estradiol $17-\beta$ concentration. Immediately, all rats were sacrificed and the ovarian morphology, ovary weight and number of follicles were recorded. Ovaries were fixed for histomorphological examination. Higher standard and treatment groups were significantly increased on ovary weight and the number of follicles more than 1mm compared with lower standard and treatment. However, no difference revealed between standard and treatment groups. ANTORIN R-10 was similar effects of follicles development and maturation compared with House standard FSH.

A New Terminology Classification System for the Open Korean Knowledge Dictionary and Reclassification (개방형 한국어 지식 대사전 전문용어 신분류 체계 설정 및 재분류)

  • Hwang, Humor;Kim, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.214-221
    • /
    • 2015
  • A new classification system with 9 main categories and 56 subcategories for the Open Korean Knowledge Dictionary is proposed. The classification system setup is to prepare for the standard classification system to be used to manage effectively vast of terminologies which were published in the Open Korean Knowledge Dictionary and is meant to enhance the fifteen-year old classification system for the standard korean great dictionary to match up to the trend of the modern terminology. The new terminology classification system covering all the academic areas such as humanity, sociology, politics, science, medicine, agriculture, engineering, etc, is designed and proposed after investigating several classification systems. The classification system setup procedures follow as ${\circ}$ The classification system is designed and planed by both the classification system and the academic expert. ${\circ}$ Classification system design covers all the academic areas following National Science and Technology standard classification system after investigating several classification systems such as the National Research Foundation, National Science and Technology Standard Act, Ministry of Knowledge Economy. ${\circ}$ Poll and survey is made to collect comments from total 93 members of several academic areas. ${\circ}$ The poll result is reviewed among working group members and utilized to update the new terminology classification system. Reclassifications are made for the around 200,000 terms in electricity, computer, medicine, pharmacy, biology, and economics according to the new terminology classification system.

Index of Organic Matter in Stream and Lake (하천·호소의 유기물 지표 평가)

  • Yu, Soon Ju;Hwang, Jong Yeon;Yoon, Young Sam;Cheon, Se Uk;Han, Eui Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.1
    • /
    • pp.81-92
    • /
    • 1999
  • This study discussed the appropriateness of organic matter indexes such as biochemical oxygen demand(BOD) and chemical oxygen demand with potassium permanganate($COD_{Mn}$) in water quality environmental standard of streams and lakes and the applicability of the items to water quality environmental standard to add or substitute COD with potassium dichromate ($COD_{Cr}$) and total organic carbon(TOC) being used as index of organic matter. And indexes of organic matter content and organic carbon concentration were distinguished between dissolved and particulate component in water sample to estimate their effect on pollutants loading in lake and stream. The ratio of $COD_{Cr}$/BOD was 5.1 under BOD concentration 3mg/L in river water quality environmental standard II, and 2.67 above it. This ratio was diminished to 2.04 when BOD concentration was more than 8mg/L, in river quality environmental standard IV. Also the ratio of $COD_{Mn}$/BOD showed 2.16 under 3mg/L(BOD), and 1.1 above it. This ratio is also diminished to 0.84 over 8mg/L(BOD). Accordingly, we should apply this ratio depending on the concentration level to add and change organic matter index of water quality environmental standard newly. The ratio $COD_{Cr}/COD_{Mn}$ both in lake and stream shows 2.37(r=0.986, p<0.001). But the ratios showed range of 2.34~2.50, which is no much difference of this ratio according to $COD_{Mn}$ concentration.

  • PDF

Analysis of Heat Dissipation Characteristics for Standard 25 [W] LED Module of Korea Expressway Corporation: Using CFD Analysis (CFD 해석을 이용한 한국도로공사 표준 25 [W] LED 모듈의 방열 특성 분석)

  • Lee, Se-Il;Her, In-Sung;Lee, A-Ram;Jung, Min-Joo;Yu, Young-Moon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.8
    • /
    • pp.541-546
    • /
    • 2014
  • Korea Expressway Corporation established standard of LED lighting fixture in Dec. 2013. To raise compatibility, the standard requires a fixed form and it is applied to street lights and tunnel lights, etc. Because streetlight has different circumstance condition from tunnel light that is down light and exposed to constant wind velocity over height of 8 meters, in case of LED module which has the same shape, characteristic of radiant heat can be different. In this paper, we designed 25 [W] LED Module that is designated by standard of Korea Expressway Corporation and analyzed characteristics of radiant heat about natural convection and forced convection. It is dropped 10.12[$^{\circ}C$] that max temperature is decreased by increasing 20 mm of bended height of heatsink at the condition of natural convection. Radiant heat characteristic of bended height 35 mm became 78.08[$^{\circ}C$] at the condition of natural convection, 55.30[$^{\circ}C$] at the condition of forced convection so that 22.78[$^{\circ}C$] is decreased that is 29.1[%] decrease. Bended height 55mm became 67.96[$^{\circ}C$] at the condition of natural convection, 48.04[$^{\circ}C$] at the condition of forced convection so that 19.92[$^{\circ}C$] is decreased that is 29.3% decrease.