• Title/Summary/Keyword: National measurements standards

Search Result 171, Processing Time 0.03 seconds

A Study on the Nutritional Assessment of Early Childhood Using Mid-Upper-Arm Circumference (상박위(上膊圍)에 의(依)한 성장기(成長期) 아동(兒童)에 영양상태(營養狀態)의 판정(判定)에 관(關)한 연구(硏究))

  • Tchai, B.S.;Nam, Y.K.;Chung, Y.J.
    • Journal of Nutrition and Health
    • /
    • v.8 no.4
    • /
    • pp.9-14
    • /
    • 1975
  • Growth retardation and a variable degree of body disproportion are recognized features of malnutrition, and mild and moderate protein-calorie malnutrition(PCM). Among the various body measurements suggested to assess the prevalence of all grades of PCM as judged by growth retardation and by body disproportion, the 'mid-upper-arm circumference'-abbreviated to 'arm-circumference' has been suggested as a potential useful simple field index for the assessment of PCM showing that the measurement would give composite information simultaneously on three important effects on PCM-deficit in the muscle protein reservoirs, availability of calorie stores in the form of subcutaneous fat, and growth failure. And this is selected because of its easy accessibility, and less involvement with clinical edema. This study is conducted to make a comparison between the percentage of Korean weight for age standards and the percentage of mid-upper-arm circumference for age standards of 175 preschool children aged $3{\sim}72$ months who are selected among the low-income residents in Seoul. In this study, a comparison is made between the results obtained by expressing the observed weight of the child as a percentage of Korean standard, referred to as 'weight-for-age' and the observed arm-circumference expressed as a percentage of the age-specific arm standard of Jelliffe, referred to as 'arm-for-age'. All the measurements were taken following the techniques described by Jelliffe. The left mid upper arm was measured using a glass-fibre tape and the Fairbanks Morse beam balance was used for weighing. 80% level of weight for age Korean standard and 85% level of arm for are Jelliffe standard were used as an upper borderline limit for PCM. Comparing the 80% weight-for-age and the 85% arm-for-age standard as an upper limit for PCM, for children aged $3{\sim}72$ months, results in 84.6% agreement with the sensitivity of 86.4% and its specificity of 83.5%. If arm circumference alone had been measured and judgement made on this basis, then only 5.1% of the children would have been 'wrongly' classified. And there is a moderately close correlation between arm circumference and weight for age as the data in Table 4 shows. The problem therefore lies in the standard for arm circumference in normal children and in determining what is the lower limit of normal. Once this is clearly difined, one can rely more confidently on arm circumference measurements alone for the nutritional assessment of early childhood.

  • PDF

Prediction of Retail Beef Yield Using Parameters Based on Korean Beef Carcass Grading Standards

  • Choy, Yun-Ho;Choi, Seong-Bok;Jeon, Gi-Jun;Kim, Hyeong-Cheol;Chung, Hak-Jae;Lee, Jong-Moon;Park, Beom-Young;Lee, Sun-Ho
    • Food Science of Animal Resources
    • /
    • v.30 no.6
    • /
    • pp.905-909
    • /
    • 2010
  • Two sets of data on carcass traits and beef cut parameters were used to investigate the relationships between carcass and beef cut measurements, which can be used to make predictions of retail cut percentages. One set had a total of 1,141 measurements of Hanwoo cattle of three different sex origins, which were slaughtered in an abattoir located at the National Institute of Animal Science, RDA, Korea from 1996 to 2008. To develop prediction models for retail cut percentage with higher accuracies than the current model, another set consisting of a total of 13,389 records of carcass and beef cut traits were collected from 30 abattoirs and butcheries in Korea from 2008 to 2009. Bulls yielded heavier and leaner carcasses than steers. High correlation coefficients were estimated between amount of body fat and percent retail cut (-0.82) as well as between back fat thickness (BF) and percent retail cut (-0.62). The amount of retail cut, however, was highly correlated with body weight before slaughter (BW, 0.95) or with cold carcass weight (CWT, 0.94). Relationships between percent retail cut and measurable beef yield traits, BF, loin eye area (LEA) or CWT varied by sex class, which must be considered for development of a prediction model with high accuracy. Models of data for all breeds and sexes fit the effects of breed, sex, and interaction of abattoir by butchers, whereas models of data for each breed and sex fit the effect of interaction of abattoir by butcher only. Due to possible future changes in back fat control, we performed a log transformation of BF. Our new models fit better than the currently used model.

Magnetotransport of Be-doped GaMnAs (GaMnAs의 Be 병행 도핑에 의한 자기 수송 특성 연구)

  • Im W. S.;Yoon T. S.;Yu F. C.;Gao C. X.;Kim D. J.;Ibm Y. E.;Kim H. J.;Kim C. S.;Kim C. O.
    • Korean Journal of Materials Research
    • /
    • v.15 no.1
    • /
    • pp.73-77
    • /
    • 2005
  • Motivated by the enhanced magnetic properties of Mg-codoped GaMnN ferromagnetic semiconductors, Be-codoped GaMnAs films were grown via molecular beam epitaxy with varying Mn flux at a fixed Be flux. The structural, electrical, and magnetic properties were investigated. GaAs:(Mn,Be) films showed metallic behavior while GaAs:Mn films showed semiconducting behavior as determined by the temperature dependent resistivity measurements. The Hall-effect measurements with varying magnetic field showed clear anomalous Hall effect up to room temperature proving ferromagnetism and magnetotransport in the GaAs:(Mn,Be) films. Planar Hall resistance measurement also confirmed the properties. The dramatic enhancement of the Curie temperature in GaMnAs system was attributed to Be codoping in the GaMnAs films as well as MnAs precipitation.

Validation of the mobile wireless digital automatic blood pressure monitor using the cuff pressure oscillometric method, for clinical use and self-management, according to international protocols

  • Yoo, Sooyoung;Baek, Hyunyoung;Doh, Kibbeum;Jeong, Jiyeoun;Ahn, Soyeon;Oh, Il-Young;Kim, Kidong
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.399-404
    • /
    • 2018
  • The purpose of this study was to evaluate the accuracy of a mobile wireless digital automatic blood pressure monitor for clinical use and mobile health (mHealth). In this study, a manual sphygmomanometer and a digital blood pressure monitor were tested in 100 participants in a repetitive and sequential manner to measure blood pressure. The guidelines for measurement used the Korea Food & Drug Administration protocol, which reflects international standards, such as the American National Standard Institution/Association for the Advancement of Medical Instrumentation SP 10: 1992 and the British Hypertension Society protocol. Measurements were generally consistent across observers according to the measured mean ${\pm}SD$, which ranged in $0.1{\pm}2.6mmHg$ for systolic blood pressure (SBP) and $0.5{\pm}2.2mmHg$ for diastolic blood pressure (DBP). For the device and the observer, the difference in average blood pressure (mean${\pm}$SD) was $2.3{\pm}4.7mmHg$ for SBP and $2.0{\pm}4.2mmHg$ for DBP. The SBP and DBP measured in this study showed accurate measurements that satisfied all criteria, including an average difference that did not exceed 5 mmHg and a standard deviation that did not exceed 8 mmHg. The mobile wireless digital blood pressure monitor has the potential for clinical use and managing one's own health.

Purity assignment of 17β-estradiol by mass balance method

  • Lee, Hwa-Shim;Oh, Kwang-Hoon
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.226-233
    • /
    • 2017
  • In general, quantitative chemical analysis in various areas including food, the environment, in vitro diagnostics, etc., requires traceability in order to increase the reliability of the measurements. Measurement traceability is a property of an unbroken chain of comparisons relating an instrument's measurements to SI units. Purity analysis is the first process for establishing traceability to SI units in chemical measurements. The purpose of this study is to develop and validate a method of purity assignment for establishing the traceability of $17{\beta}$-estradiol measurements in an in vitro diagnostics field. The establishment of this method is very important as it can be applied to the development of CRM and to the analysis of the purity of other hormones. The method of assignment of the purity of $17{\beta}$-estradiol was developed using the mass balance method and was validated through participation in an International comparison. In the mass balance method, impurities are categorized into four classes as follows: total related structure impurities, water, residual organic solvents, and nonvolatiles/inorganics. In this study, total related structure impurities were characterized by a gas chromatography-flame ionization detector (GC-FID) and a high-performance liquid chromatography-ultraviolet (HPLC-UV) detector, water content was determined by a Karl-Fisher coulometer, and total residual solvents and nonvolatiles/inorganics were checked simultaneously by thermogravimetric analysis (TGA). The purity of the $17{\beta}$-estradiol was 985.6 mg/g and the expanded uncertainty was 2.1 mg/g at 95% confidence. The developed method can be applied to the development of certified reference materials, which play a critical role in traceability.

Detection of Rapid Atrial Arrhythmias in SQUID Magnetocardiography (스퀴드 심자도 장치를 이용한 심방성 부정맥의 측정)

  • Kim Kiwoong;Kwon Hyukchan;Kim Ki-Dam;Lee Yong-Ho;Kim Jin-Mok;Kim In-Seon;Lim Hyun-Kyoon;Park Yong-Ki;Kim Doo-Sang;Lim Seung-Pyung
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.28-35
    • /
    • 2005
  • We propose a method to measure atrial arrhythmias (AA) such as atrial fibrillation (Afb) and atrial flutter (Afl) with a SQUID magnetocardiograph (MCG) system. To detect AA is one of challenging topics in MCG. As the AA generally have irregular rhythm and atrio-ventricular conduction, the MCG signal cannot be improved by QRS averaging; therefore a SQUID MCG system having a high SNR is required to measure informative atrial excitation with a single scan. In the case of Afb, diminished f waves are much smaller than normal P waves because the sources are usually located on the posterior wall of the heart. In this study, we utilize an MCG system measuring tangential field components, which is known to be more sensitive to a deeper current source. The average noise spectral density of the whole system in a magnetic shielded room was $10\;fT/{\surd}Hz(a)\;1\;Hz\;and\;5\;fT/{\surd}Hz\;(a)\;100\;Hz$. We measured the MCG signals of patients with chronic Afb and Afl. Before the AA measurement, the comparison between the measurements in supine and prone positions for P waves has been conducted and the experiment gave a result that the supine position is more suitable to measure the atrial excitation. Therefore, the AA was measured in subject's supine position. Clinical potential of AA measurement in MCG is to find an aspect of a reentry circuit and to localize the abnormal stimulation noninvasively. To give useful information about the abnormal excitation, we have developed a method, separative synthetic aperture magnetometry (sSAM). The basic idea of sSAM is to visualize current source distribution corresponding to the atrial excitation, which are separated from the ventricular excitation and the Gaussian sensor noises. By using sSAM, we localized the source of an Afl successfully.

  • PDF

Friction correction for model ship resistance and propulsion tests in ice at NRC's OCRE-RC

  • Lau, Michael
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.3
    • /
    • pp.413-420
    • /
    • 2018
  • This paper documents the result of a preliminary analysis on the influence of hull-ice friction coefficient on model resistance and power predictions and their correlation to full-scale measurements. The study is based on previous model-scale/full-scale correlations performed on the National Research Council - Ocean, Coastal, and River Engineering Research Center's (NRC/OCRE-RC) model test data. There are two objectives for the current study: (1) to validate NRC/OCRE-RC's modeling standards in regarding to its practice of specifying a CFC (Correlation Friction Coefficient) of 0.05 for all its ship models; and (2) to develop a correction methodology for its resistance and propulsion predictions when the model is prepared with an ice friction coefficient slightly deviated from the CFC of 0.05. The mean CFC of 0.056 and 0.050 for perfect correlation as computed from the resistance and power analysis, respectively, have justified NRC/OCRE-RC's selection of 0.05 for the CFC of all its models. Furthermore, a procedure for minor friction corrections is developed.

Effect of Pr substitution on the normal-state and superconducting properties of GdBa$_2$(Cu$_{2.9}$Al$_{0.1}$)O$_z$

  • Park, Jung-Rok;Ha, Dong-Han;Lee, Ho-Keum
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.70-75
    • /
    • 2000
  • We report results of a comparative study of the normal-state and superconducting properties in the GdBa$_2$(Cu$_{2.9}$Al$_{0.1}$)O$_z$ system with substitutions by Pr for the Gd and Ba sites. It is observed that, fur both Pr-doped systems, the superconducting transition temperature(T$_c$) decreases almost linearly with the Pr-content, but Pr at Ba sites results in a faster T$_c$ drop than that of Pr at Gd sites. The thermoelectric power measurements indicate that there is a strong correlation between the T$_c$ and the room temperature value of thermoelectric power. The experimental results are discussed in connection with existing models.

  • PDF

Determination of Bovine Serum Albumin by Its Enhancement Effect of Nile Blue Fluorescence

  • Lee, Sang-Hak;Suh, Jung-Kee;Li, Ming
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.1
    • /
    • pp.45-48
    • /
    • 2003
  • A novel fluorimetric method has been developed for the determination of microgram quantities of bovine serum albumin (BSA) based on its enhancement effect of Nile Blue fluorescence at 670 nm, caused by binding of Nile Blue to BSA to produce a stable water soluble complex. The binding constant of micromole Nile Blue-BSA complex was estimated by Scatchard plot method. Under the optimal conditions, the increased fluorescence intensity was linearly related to BSA concentration in the range of 0.5-12.0 ㎍/mL. The detection limit was 0.2 ㎍/mL, and the relative standard deviation of six replicate measurements was 1.4% for 10.0 ㎍/mL BSA. There was little interference from amino acids, sugars and most of metal ions.

Resistance Distribution in Thin Film Type SFCL Elements with Shunt Layers of Different Thicknes

  • Kim, Hye-Rim;Hyun, Ok-Bae;Lee, Seung-Yup;Yu, Kwon-Kyu;Kim, In-Seon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.41-45
    • /
    • 2003
  • Resistance distribution in thin film type SFCL elements of different shunt layer thickness was investigated. The 300 nm thick film of 2 inch diameter was coated with a gold layer and patterned into 2 mm wide meander lines. The shunt layer thickness was varied by ion milling the shunt layer with Ar ions, and also by having the shunt layer grown in different thickness. The SFCL element was subjected to simulated AC fault current for measurements. It was immersed in liquid nitrogenduring the experiment. The resistance distribution was not affected by the shunt layer thickness at applied voltages that brought the temperature of the elements to similar values. This result could be explained with the concept of heat transfer from the film to the surroundings. The resistance distribution was independent of the shunt layer thickness because thick sapphire substrates of high thermal conductivity dominated the thermal conductance of the elements.