• 제목/요약/키워드: National main facility

검색결과 250건 처리시간 0.027초

팔당호 상류수계에 위치한 환경기초시설의 인 기여도 분석 (Analysis of the Phosphorus Contribution Rate by the Environment Fundamental Facilities Located in Upstream Basin of Paldang Lake)

  • 우영국;박은영;전양근;양희정;임재명
    • 한국물환경학회지
    • /
    • 제26권6호
    • /
    • pp.1016-1027
    • /
    • 2010
  • The phosphorus contribution rate on water quality of North and South-Han River, and Gyungan-cheon by effluents from environmental fundamental facilities located in upstream basin of Paldang Lake were analyzed. QUALKO2 model was selected for the analysis of contrubution rate, and was constructed considering the location of the main point sources and all facilities in study area. The pollutant loading rates and arrival rates for each unit-watershed in study area were calculated for model operation. For the calibration and verification of model, 2006 water quality dataset from Ministry of Environment and the effluent loadings of the environmental fundamental facilities were used. Reliability Index (RI) method was used to estimate the validity of the results of calibration and verification. The phosphorous contribution rate(%) for each environmental fundamental facility were analyzed by excepting the effluent loading of the facility. The contribution rate was analyzed for each facility, facility groups separated by each main river and each unit-watershed. The main results of analysis for each facility are as follows; (i) the phosphorous contribution of B1 facility is 50%, which is the highest phosphorous contribution rate among those of nine facilities in the North-Han River Basin; (ii) the highest phosphorous contribution is 55.6% from J facility among eight facilities in the Gyungan Stream Basin; (iii) 40% from E treatment facility is the highest among those of twenty eight facilities in the South-Han River Basin.

Application of The Value Analysis To Redesign Facility Layout

  • Laurent, Eyheraguibel;Jeong, Byung-Ho;Lee, Chan-Gie;Lee, Sang-Young
    • 산업공학
    • /
    • 제10권3호
    • /
    • pp.167-177
    • /
    • 1997
  • This paper deals with an application of process value analysis method for a manufacturing process in order to redesign facility layout in a paper company. We have used the value analysis method which permits an overall and rigorous study of process by a functional approach. Firstly, customer's expectations for the future process are clearly and precisely expressed with specifications of the Functional Extern Analysis. The existing process is analyzed using various tool of the Functional Internal Analysis in the second part. From the results of these analysis, we find out that the main problems of current facility are due to scheduling and facility layout. This paper is devoted to resolve the second problem. We suggest an ideal solution in order to have a reference solution. Nextly, We give realistic choices and the final solution for the facility layout.

  • PDF

The MARS Simulation of the ATLAS Main Steam Line Break Experiment

  • Ha, Tae Wook;Yun, Byong Jo;Jeong, Jae Jun
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.112-122
    • /
    • 2014
  • A main steam line break (MSLB) test at the ATLAS facility was simulated using the best-estimate thermal-hydraulic system code, MARS-KS. This has been performed as an activity at the third domestic standard problem for code benchmark (DSP-03) that has been organized by Korea Atomic Energy Research Institute (KAERI). The results of the MSLB experiment and the MARS input data prepared for the previous DSP-02 using the ATLAS facility were provided to participants. The preliminary MSLB simulation using the base input data, however, showed unphysical results in the primary-to-secondary heat transfer. To resolve the problems, some improvements were implemented in the MARS input modelling. These include the use of fine meshes for the bottom region of the steam generator secondary side and proper thermal-hydraulics calculation options. Other input model improvements in the heat loss and the flow restrictor models were also made and the results were investigated in detail. From the results of simulations, the limitations and further improvement areas of the MARS code were identified.

식재료 전처리시설의 설치방안 검토 - 경남 창원지역의 사례를 중심으로 - (Review of Establishing Pre-Processing Facility of Agricultural Products - With a Case of Changwon Area -)

  • 이상학;이한성;최세현
    • 농업과학연구
    • /
    • 제37권1호
    • /
    • pp.131-141
    • /
    • 2010
  • This paper aims to review how pre-processing facility of agricultural products can be established and operated. First of all, industry and its enterprises of pre-processing agricultural products are analyzed from the national perspective. Especially, five well-known pre-processing business units operated by producers' organizations are introduced including Ansung Machoom Agricultural Cooperative. Changwon City in Gyeongnam Province was chosen for a case study. Demand for local agricultural products by school feeding and other institutional food service in Changwon area is estimated and it is compared with the supply of agricultural products produced in the region. Questionnaire survey was done for school nutritionists and the main results are summarized. In the final stage, basic ideas for pre-processing facility of agricultural products in Changwon area are proposed considering the previous analyses. These ideas include size of the facility, participants and scope of the business, and location. Virtual profitability analysis is also conducted for the facility. Some suggestions for the proposed facility to be more successful in the future are suggested at the conclusion.

빅데이터를 활용한 중소도시의 생활SOC 결핍지역 추출 연구 - 전라북도 익산시를 중심으로 - (A Study on the Extraction of Living SOC Deficient Areas in Small and Medium Cities Using Big Data - Focused on Iksan-si, Jeollabuk-do -)

  • 한다혁;김동우;이민석
    • 한국농촌건축학회논문집
    • /
    • 제22권4호
    • /
    • pp.43-50
    • /
    • 2020
  • The purpose of this study is to extract deficiency areas as basic data of policies and projects in the future Living SOC introduction and planning. In order to extract living SOC deficient areas, accessibility data for living SOC and density data for main users by facility were overlapped, focusing on the living SOC indicators presented in the National Urban Regeneration Basic Policy. According to the analysis of accessibility of the Iksan-si Living SOC, the gap between deficiency in urban and township areas was large in common with the accessibility of the village and local base units. As a result of overlapping life SOC accessibility data and density data analysis of the main users by facility, areas where accessibility is weak but not inhabited by the main users of each facility were extracted. It is meaningful that more accurate deficient areas can be extracted by simultaneously utilizing the density distribution of the main users, rather than simply accessing the facilities.

냉동냉장설비의 수요예측에 관한 연구 (Study on Demand Prediction of Cold Storage Facilities)

  • 손창효;오후규
    • 설비공학논문집
    • /
    • 제23권9호
    • /
    • pp.587-594
    • /
    • 2011
  • This paper describes the investigation on current state of cold storage facilities, and analysis on the demand prediction in the near future. And based on the analysis results, we prospect the scale of cold storage facilities in the near future. The main analysis results are summarized by the followings ; The present circumstances of cold storage facility are determined by investigating actual loading capacity, average stock amounts, and return number of cold storage facility. From the results, the present situation for cold storage facility is about 3% over. It is found that the average stock amounts increase gradually, and accordingly that the demand of cold storage facility is predicted to be increased, resulting that the capacity of cold storage facilities in 2013 expects to reach up to 5,250,000 ton. It is considered that the results of demand prediction has significant implications on the management of cold storage facility in the near future.

음식물류폐기물 공공 자원화시설의 운영실태 조사를 통한 처리공정별 효율적인 운영방안 검토 (Investigation on the operational state of the public food waste treatment facilities and suggestions on their efficient operational management)

  • 장윤혁;박준석;김정대;배재근
    • 유기물자원화
    • /
    • 제18권1호
    • /
    • pp.47-56
    • /
    • 2010
  • 현재 전국에는 255개의 음식물류 폐기물 자원화시설이 공공시설(95개소) 및 민간시설(160개소)에 의하여 운영되고 있으며, 이들 시설들은 97년도부터 지속적으로 설치되고 있다. 정부에서는 설치 및 운영에 관한 지침과 설치검사기준 등을 정하여 시행하고 있으나, 시설 설치 절차에 따른 세부적인 검토사항, 설계, 공정기준 등이 명확하지 않아 운영관리 체계 미흡, 처리효율 저하, 시설 하자 등이 문제점이 발생되고 있다. 따라서, 본 연구에서는 이들 문제점을 최소화하기 위한 시설 운영방안을 제시하기 위해 음식물 공공자원화시설 95개소를 대상으로 설문 및 현장방문조사를 실시하였다. 조사결과 전처리시설에서는 2계열 및 호퍼덮개 미설치, 음식물 과적 및 이송 물량 과다, 주처리시설은 운전미숙으로 인한 2차 환경오염발생, 과다 음식물투입으로 시설효율 저하, 시설운영상 부적합한 운전관리 기준 등이 문제점으로 조사되었다. 악취 및 음폐수(음식물류폐기물 처리과정 중 발생 폐수) 처리시설에서는 운영미숙, 주기적인 점검 부족, 처리시설 용량 부적절 등이 문제점으로 조사되었다. 이와 같이 조사되어진 문제점을 근거로 하여 효율적인 운영방안을 제시하였으며, 향후 음식물류 폐기물 자원화시설을 설치 및 운영하는데 있어 처리효율 제고, 시행착오 및 하자를 최소화할 수 있을 것으로 판단된다.

농촌지역 초·중등 교육시설에 대한 마을단위 접근성 평가 (Evaluation of Accessibility to Elementary and Secondary Educational Facilities on Village Level in Rural Areas)

  • 김솔희;김태곤;서교
    • 농촌계획
    • /
    • 제23권3호
    • /
    • pp.121-131
    • /
    • 2017
  • Although the educational facility are an important considerations on a social equity standpoint, educational environment in rural areas has been continuously deteriorated by numerous social problems such as decreasing birth rate and increasing of local school closing. The purpose of this study is to evaluate the accessibility of educational environment in rural areas on village level. First, we evaluate physical accessibility based on legally defined commuting distance. Second, the implication of village population of potential accessibility is analyzed. Lastly, the facility centrality index of each village is estimated for assessing the relations of educational accessibility. The main results of this study are as follows; (1) The accessibility of most villages in Pyeongchang-gun is vulnerable that 81.10% for elementary school, 73.17% for middle school, and 82.32% for high school, respectively; (2) The average commuting distance per student considering estimated number of students for each educational facilities indicated 2.75km for elementary school, 4.37km for middle school, and 5.79km for high school; (3) the facility centrality index is highly correlated to educational facilities but not to village population.

Shielding design and analyses of the cold neutron guide hall for the KIPT neutron source facility

  • Zhong, Zhaopeng;Gohar, Yousry
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.989-995
    • /
    • 2018
  • Argonne National Laboratory of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have cooperated on the development, design, and construction of a neutron source facility. The facility was constructed at Kharkov, Ukraine, and its commissioning process is underway. The facility will be used for researches, producing medical isotopes, and training young nuclear specialists. The neutron source facility is designed with a provision to include a cryogenically cooled moderator system-a cold neutron source (CNS). This CNS provides low-energy neutrons, which will be used in the scattering experiment and material structures analysis. Cold neutron guides, coated with reflective material for the low-energy neutrons, will be used to transport the cold neutrons to the experimental site. The cold neutron guides would keep the cold neutrons within certain energy and angular space concentrated inside, while most of the gamma rays and high-energy neutrons are not affected by the cold neutron guides. For the KIPT design, the cold neutron guides need to extend several meters outside the main shield of the facility, and curved guides will also be used to remove the gamma and high-energy neutron. The neutron guides should be installed inside a shield structure to ensure an acceptable biological dose in the facility hall. Heavy concrete is the selected shielding material because of its acceptable performance and cost. Shield design analysis was carried out for the CNS guide hall. MCNPX was used as the major computation tool for the design analysis, with neutron and gamma dose calculated separately. Weight windows variance reduction technique was also used in the shield design. The goal of the shield design is to keep the total radiation dose below the $5.0{\mu}Sv/hr$ guideline outside the shield boundary. After a series of iterative MCNPX calculations, the shield configuration and parameters of CNS guide hall were determined and presented in this article.

차세대 반도체 펩을 위한 육각형 물류 구조의 설계 (Hexagonal Material Flow Pattern for Next Generation Semiconductor Fabrication)

  • 정재우;서정대
    • 대한산업공학회지
    • /
    • 제36권1호
    • /
    • pp.42-51
    • /
    • 2010
  • The semiconductor industry is highly capital and technology intensive. Technology advancement on circuit design and process improvement requires chip makers continuously to invest a new fabrication facility that costs more than 3 billion US dollars. Especially major semiconductor companies recently started to discuss 450mm fabrication substituting existing 300mm fabrication of which facilities were initiated to build in 1998. If the plan is consolidated, the yield of 450mm facility would be more than doubled compared to existing 300mm facility. In steps of this important investment, facility layout has been acknowledged as one of the most important factors to be competitive in the market. This research proposes a new concept of semiconductor facility layout using hexagonal floor plan and its compatible material flow pattern. The main objective of this proposal is to improve the productivity of the unified layout that has been popularly used to build existing facilities. In this research, practical characteristics of the semiconductor fabrication are taken into account to develop a new layout alternative based on the analysis of Chung and Tanchoco (2009). The performance of the proposed layout alternative is analyzed using computer simulation and the results show that the new layout alternative outperforms the existing layout alternative, unified layout. However, a few questions on space efficiency to the new alternative were raised in communication with industry practitioners. These questions are left for a future study.