• Title/Summary/Keyword: National labs

Search Result 128, Processing Time 0.027 seconds

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on more than 550 bed sized hospitals (종합병원 진단검사의학과 검사실의 시설 설비 현황 조사 - 550 병상 이상 종합병원을 중심으로)

  • Kim, Youngaee;Song, Sanghoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.1
    • /
    • pp.73-84
    • /
    • 2020
  • Purpose: Though Korean healthcare services have been upgraded, infection and fire had been broken out in general hospitals. And higher concerns about quality assessment made it to clinical laboratory design guideline studies. So, this study investigates the facilities, equipment and personnel of laboratory medicine focusing on more than five hundred fifty bed hospital, and contributes to make guidelines for safety and efficiency in lab. Methods: Questionnaires to supervisor technologist and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 16 answers have been analysed statistically by MS Excel program. Results: Most of the sample tests such as hematology, clinical chemistry, immunology, transfusion, urinalysis, microbiology and molecular diagnosis are performed by more than 80% in large sized general hospital laboratory. In the test methods, automatic analyzers are used up to 80%, total laboratory automation up to 43% in clinical chemistry and immunology, and manual tests in all sorts of the test. There are placed in single lab or two and three labs above the ground, which are all in semi-open lab. There is some correlation with the number of specimens and the number of lab people depending on the number of hospital beds. Laboratory environment shows that work distance is good, but evacuation path width, visibility, separation of staff area from automatic analyzer, and equipment installations are needed to have more spaces and gears. Most of the infection controls are equipped with mechanical ventilation, air-conditioning, washbasin and wastewater separation, BSC installation and negative pressure lab room. Implications: Although the laboratory space area is calculated considering the number of hospital beds, type of tests and number of staff, hospital's expertise and the samples numbers per year should be taken into account in the planning of the hospital.

Evaluation on Resistance Spot Weldability and Nugget Formation of Surface Roughness Treated Steel Sheet (표면조도 특성에 따른 저항 점 용접성 평가 및 너깃 형성 고찰)

  • Kim, Ki-Hong;Choi, Yung-Min;Kim, Young-Seok;Rhym, Young-Mok;Yu, Ji-Hun;Kang, Nam-Hyun;Park, Yeong-Do
    • Journal of Welding and Joining
    • /
    • v.26 no.5
    • /
    • pp.79-89
    • /
    • 2008
  • With the increased use of surface textured steel sheet in body-in-white assembly, resistance spot weldability of these steels is considered to be an important subject. This study evaluated nugget formation and weldability by measuring dynamic resistance with various weld pressure, current, and weld time for steel sheet with two different surface roughnesses. The surface roughness for T-H steel ($R_{a}=1.70\;{\mu}m$) was higher than that for T-L steel ($R_{a}=1.33\;{\mu}m$), and resulted in increased contact resistance and heating for T-H steel spot welding. Therefore, at low weld current and weld cycle ranges, the T-H steel showed better weldability over the T-L steel. The evaluations of weld interface showed that the fusion zone in the T-H steel sheet was continuous in contrast to discontinuous fusion zone for T-L steel sheet at the same welding conditions. A comparison of dynamic resistance and tensile-shear strength (TSS) between T-H and T-L steel sheet suggested that high surface roughness provided larger heating at early cycle of welding and larger TSS.

Resistance Spot Weldability of Surface Roughness Textured Galvannealed Steel Sheets (표면조도처리 된 합금화 용융아연도금강판의 저항 점 용접성)

  • Park, Sang-Soon;Kim, Ki-Hong;Kang, Nam-Hyun;Kim, Young-Seok;Rhym, Young-Mok;Choi, Yung-Min;Park, Yeong-Do
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.8
    • /
    • pp.495-505
    • /
    • 2008
  • With the high proportion of zinc coated steels in body-in-white assembly, newly developed surface roughness textured galvannealed steel sheets have been introduced. In this study, zinc coated and surface roughness textured steel sheets were welded by resistance spot welding to investigate its weldability including electrode wear test. Based on the results of tensile-shear test, nugget diameter changes, and electrode tip growth test, it was clear that both surface roughness textured steels (GA-T and GA-E) showed good weldability. Also, there was no large difference in weldability and electrode wear behavior between GA-T and GA-E steels which have different surface roughness morphology. An analysis of electrode degradation showed Fe and Zn penetration through the electrode tip surface at 2400 welds reached $55{\sim}60{\mu}m$ and $75{\sim}80{\mu}m$, respectively. Therefore, there is no significant effect of surface roughness morphology on spot weldability of surface roughness textured galvannealed steel sheets. However, slight difference in thickness of alloying layers existing on electrode tip was found between GA-T and GA-E steels.

E-Isolation : High-performance Dynamic Testing Installation for Seismic Isolation Bearings and Damping Devices

  • Yoshikazu Takahashi;Toru Takeuchi;Shoichi Kishiki;Yozo Shinozaki;Masako Yoneda;Koichi Kajiwara;Akira Wada
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.1
    • /
    • pp.93-105
    • /
    • 2023
  • Seismic isolation and vibration control techniques have been developed and put into practical use by challenging researchers and engineers worldwide since the latter half of the 20th century, and after more than 40 years, they are now used in thousands of buildings, private residences, highways in many seismic areas in the world. Seismic isolation and vibration control structures can keep the structures undamaged even in a major earthquake and realize continuous occupancy. This performance has come to be recognized not only by engineers but also by ordinary people, becoming indispensable for the formation of a resilient society. However, the dynamic characteristics of seismically isolated bearings, the key elements, are highly dependent on the size effect and rate-of-loading, especially under extreme loading conditions. Therefore, confirming the actual properties and performance of these bearings with full-scale specimens under prescribed dynamic loading protocols is essential. The number of testing facilities with such capacity is still limited and even though the existing labs in the US, China, Taiwan, Italy, etc. are conducting these tests, their dynamic loading test setups are subjected to friction generated by the large vertical loads and inertial force of the heavy table which affect the accuracy of measured forces. To solve this problem, the authors have proposed a direct reaction force measuring system that can eliminate the effects of friction and inertia forces, and a seismic isolation testing facility with the proposed system (E-isolation) will be completed on March 2023 in Japan. This test facility is designed to conduct not only dynamic loading tests of seismic isolation bearings and dampers but also to perform hybrid simulations of seismically isolated structures. In this paper, design details and the realization of this system into an actual dynamic testing facility are presented and the outcomes are discussed.

Analysis of Overseas Cases and Field Requirements for SW Education Classrooms (SW교육 교실 구축을 위한 해외 사례 및 현장 요구조사 분석)

  • Ahn, Sung Hun
    • Journal of Creative Information Culture
    • /
    • v.5 no.3
    • /
    • pp.355-364
    • /
    • 2019
  • In this paper, in order to prepare a classroom model that can effectively operate SW education, this study explored cases of creative educational space construction overseas and conducted a demand survey on elementary and middle school teachers. As a result, in overseas cases, classrooms were constructed in various forms, and furniture in the classrooms were produced in various shapes and sizes, and the cases using advanced equipment were explored. As a result of the survey on the education site, it was found that the most desired installation is a fluid type that can restructure the space by freely moving the facilities according to the teaching method. The results of the analysis are expected to be of great help in rebuilding computer labs or building infrastructure for future SW training.

Physicochemical characteristics and fatty acid profiles of muscle tissues from Hanwoo steers fed a total mixed ration supplied with medicinal plant by-products

  • Lee, Shin Ja;Kim, Do Hyung;Yang, Han Sul;Nam, Ki Chang;Ahn, Seung Kyu;Park, Sung Kwon;Choi, Chang Weon;Lee, Sung Sill
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.10
    • /
    • pp.1388-1395
    • /
    • 2017
  • Objective: Using medicinal plant by-products (MPBP) as feed additives may be an eco-friendly option as substitutes for feedstuffs and may assist in reducing the improper disposal of MPBP. Therefore, this study was conducted to evaluate the influences of MPBP on the meat quality of Hanwoo steers fed a total mixed ration (TMR). Methods: Twenty seven steers (body weight = $573{\pm}57kg$) were randomly divided into three treatments with a control group and two tested groups as follows: control, 1,000 g/kg TMR; treatment 1 (MPBP30), 970 g/kg TMR and 30 g/kg MPBP; treatment 2 (MPBP50), 950 g/kg TMR and 50 g/kg MPBP. Results: Average daily gain, feed conversion ratio and the Commission Internationale de l'Eclairage $L^*$ of muscle were improved (p<0.05, respectively) by MPBP30. Stearic acid ($C_{18:0}$) was decreased (linear effect, p = 0.012), while oleic acid ($C_{18:1}$) was increased (linear effect, p = 0.055) by MPBP level. Saturated fatty acid (SFA) and polyunsaturated fatty acid (PUFA) were decreased for MPBP50 while unsaturated fatty acid (USFA) and monounsaturated fatty acid (MUFA) were increased for MPBP 50. USFA and SFA ratio was increased for MPBP50 as well. Conclusion: These results indicated that MPBP supplementation in Hanwoo steers fed a TMR increased feed efficiency and meat color (lightness) with altering fatty acid proportions. Therefore, MPBP may be successfully used in ruminant feeding.

Job-specific Questionnaire for Estimating Exposure to Hazardous Agents among Semiconductor Workers (반도체 공정 근로자 직무 노출을 추정하기 위한 설문(Job-specific Questionnaire) 개발)

  • Park, Donguk;Choi, Sangjun;Heo, Jeongin;Roh, Hyunseog;Park, Jihoon;Ha, Kwonchul;Yoon, Chungsik;Kim, Won;Kim, Seungwon;Kim, Hyoungryoul;Kwon, Hojang
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.1
    • /
    • pp.58-63
    • /
    • 2016
  • Objectives: One major limitation encountered in retrospective exposure assessment for epidemiological study is the lack of exposure records and information maintained by companies which if they existed would allow the estimation of past exposure to hazardous operations and agents. This study developed a job-specific questionnaire(JSQ) to estimate exposure profiles among semiconductor workers, including operation and job. Methods: This JSQ can be directly applied to workers who work or have worked in a wafer fabrication or a chip packaging and assembly facility. Results and Conclusions: We used this JSQ to obtain past exposure information from semiconductor workers via face-to-face investigation. Major contents include questions on the facilities, operations and jobs to which they have been exposed since they entered employment in the semiconductor industry. The total number of questions in the JSQ is 18. Responses to this JSQ can be used not only to estimate retrospective exposure to operations and jobs in the semiconductor industry, but also to associate with the risk of all causes of death and risk of disease, including cancer.

Cache-Friendly Adaptive Video Streaming Framework Exploiting Regular Expression in Content Centric Networks (콘텐트 중심 네트워크에서 정규표현식을 활용한 캐시친화적인 적응형 스트리밍 프레임워크)

  • Son, Donghyun;Choi, Daejin;Choi, Nakjung;Song, Junghwan;Kwon, Ted Taekyoung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.9
    • /
    • pp.1776-1785
    • /
    • 2015
  • Content Centric Network (CCN) has been introduced as a new paradigm due to a shift of users's perspective of using Internet from host-centric to content-centric. On the other hand, a demand for video streaming has been increasing. Thus, Adaptive streaming has been introduced and researched for achieving higher user's satisfaction. If an architecture of Internet is replaced with CCN architecture, it is necessary to consider adaptive video streaming in CCN according to the demand of users. However, if the same rate decision algorithm used in Internet is deployed in CCN, there are a limitation of utilizing content store (CS) in CCN router and a problem of reflecting dynamic requirements. Therefore, this paper presents a framework adequate to CCN protocol and cache utilization, adapting content naming method of exploiting regular expression to the rate decision algorithm of the existing adaptive streaming. In addition, it also improves the quality of video streaming and verifies the performance through dynamic expression strategies and selection algorithm of the strategies.

Estimation of Humidifier Disinfectant Amounts Inhaled into the Respiratory System (가습기 살균제 피해자 호흡기로 흡입된 가습기 살균제 양 추정 - 호흡기 외부(external) 및 내부 노출(internal exposure) 추정 방법과 사례 -)

  • Park, Dong-Uk;Ryu, Seung-Hun;Lim, Heung-Kyu;Kim, Sun-Kyung;Roh, Hyun-Suk;Cha, Won-Seok;Park, Dooyong
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.3
    • /
    • pp.141-146
    • /
    • 2016
  • In South Korea, many cases of humidifier disinfectant-associated lung injury (HDLI) have been reported among people who used humidifier products containing humidifier disinfectant (HD). The objectives of this study are to estimate both airborne HD concentration in the room where HD was used and the amount of humidifier disinfectant absorbed into the respiratory system. Information and data on the HDs were collected using a structured questionnaire and home environmental investigations include the volume of HD (ml) and hours used per day, concentration of disinfectants contained in the HD brand (${\mu}g/ml$), volume of the room ($m^3$), assumed ventilation rate ($m^3/hr$) and breathing rate assumed ($m^3/hr$). We used children aged under five years old as a sample and estimated both airborne HD concentrations and amount of HD absorbed into the respiratory system. The estimated airborne concentration of HD in the room ranged from 68 to $369{\mu}g/m^3$ for PHMG (polyhexamethylene guanidine phosphate) and from 16 to $239{\mu}g/m^3$ for PGH (oligo (2-(2-ethoxy) ethoxyethyl guanidine). The amount of HD absorbed in the respiratory system per day was estimated to range from 227 to $1,225{\mu}g$ for PHMG and from 53 to $794{\mu}g$ for PGH. In conclusion, a great amount of HD was likely absorbed into respiratory system, likely beyond the level of the capacity of the immune system to remove the HD absorbed.

Fundamental Research of Preservation & Utility Facilities in Wetland Protected Area - 5 Wetland Protected Areas were Used as Main Subjects - (습지보호지역의 습지보전·이용시설 현황에 관한 기초 연구 - 5개 습지보호지역을 대상으로 -)

  • Cho, Dong-Gil;Park, Yong-Su;Shim, Yun-Jin;Lee, Ji-Hyun;Lee, Dong-Jin;Kim, Sang-Hyuk;Cha, Jin-Yeol;Park, Mi-Young;Song, Yu-jin;Nam, Chun-hee;Kim, Jong-cheol;Moon, Sang-kyun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.19 no.1
    • /
    • pp.25-43
    • /
    • 2016
  • This research was completed to provide fundamental data regarding the guidelines to installing and managing utility facilities & structures in wetland protected area to advance the functions and sustainable use of ecology services by preserving the ecology within wetland protected area. There were 5 on-site researching areas that were used as the main subject with these areas chosen and considered from 21 inland wetlands that have been designated and are being managed from the Ministry of Environment and by their designated dates as a wetland protected area. The utility facilities in these wetland areas were categorized by their types and a detailed on-site investigation was proceeded with investigation items chosen whereas these facilities are working by their roles from their location, size, used materials, types, information contents and etc., The results showed that regarding informational structures, several locations of information boards were distanced from the main exploring routes which did not consider the visitor's eye level which had their readability dropped and by sunlight, time lapse and water penetration, many information boards were damaged or corrupted so that it was hard to confirm the information noticed or understanding an image. Insufficient observation and educational structures were installed that considered the ecological characteristics of wild animals and their living conditions. Regarding convenience facilities, there were parking lots that were installed on the fore-land and to decrease non-point solution sources, some parking lots needed to be located in protected lowlands while some facilities' shape and colors did not harmonize with their natural surroundings, creating a sense of awareness, which will need some more consideration. As for safety facilities, they were very insufficient compared to other facilities. This means that additional safety structures are needed so that related personnel can be aware of where a visitor is located when an accident occurs. Protectional facilities strongly needed new structures and a management system to cut off entrances and do surveillance so that visitors do not go into areas outside of the managed areas and bring damages to restricted locations. Research labs needed to expand the use of automatic weather systems and water gauge equipments to build fundamental data regarding floodgates that are intimated to the forming of wetlands. Sensor cameras and other types of monitoring systems are needed to monitor the majority types of animals living in the wetlands as well.