• 제목/요약/키워드: National Measurement Standards

검색결과 429건 처리시간 0.027초

임상가를 위한 특집 4 - CBCT 검사법의 정도관리 및 선량 (Radiation Doses and Quality Assurance in Cone Beam CT(CBCT))

  • 최용석;김규태;황의환
    • 대한치과의사협회지
    • /
    • 제52권3호
    • /
    • pp.153-163
    • /
    • 2014
  • 3-dimensional information for anatomic stucture plays a role as integral part in clinical aspect of dental practice. CBCT(cone beam computed tomography) has been accepted as useful diagnostic tool offering Volume data and images for evaluating teeth and jaws in lower radiation dose than conventional CT. CBCT equipment is essential for the quality assurance of it to ensure continued satisfactory performance and result of adequate images. Dental practitioner and oral and maxillofacial radiologist should have a responsibility and critical thinking to deliver this technology to patients in a responsible way, so that diaganostic value is maximised and radiation doses kept as low as resonably achievable. CBCT imaging modality should be used only after a review of the patient's health and imaging history and the completion of a thorough clinical examination. Clinical guidelines are systematically developed statements to assist practitioner and patient decisions about appropriate health care for specific clinical circumstances Dental practitioners should prescribe CBCT imaging only when they expect that the diagnostic yield will benefit patient care, enhance patient safety or improve clinical outcomes significantly. Knowledge of patient dose is essential for clinicians who are making the decision regarding the justification of the exposure. There are some limitation in the measurement of patient dose in CBCT for the approval and adaptation of conventinal methodolgy in CT. It is also important to ensure that doses are optimised and in line with any national and international guidelines. The higher radiation doses of CBCT compared with conventional radiography, mean that high standards must be maintained. The Quality Assurance(QA) programme should entail surveys and checks that are performed according to a regular timetable. QA programme should be maintained by staff to ensure adherence to the programme and to raise its importance among staff.

LNA를 위한 새로운 프로그램 가능 고주파 검사용 설계회로 (New Programmable RF DFT Circuit for Low Noise Amplifiers)

  • 류지열;노석호
    • 대한전자공학회논문지TC
    • /
    • 제44권4호
    • /
    • pp.28-39
    • /
    • 2007
  • 본 논문에서는 저잡음 증폭기 (LNA)를 위한 새로운 구조의 프로그램 가능한 고주파 검사용 설계회로 (RF DFT)를 제안한다. 개발된 RF DFT 회로는 DC 측정만을 이용하여 LNA의 RF 변수를 측정할 수 있으며, 최근의 RFIC 소자에 매우 유용하다. DFT 회로는 프로그램 가능한 커패시터 뱅크 (programmable capacitor banks)와 RF 피크 검출기를 가진 test amplifier를 포함하며, 측정된 출력 DC 전압을 이용하여 입력 임피던스와 전압이득과 같은 LNA 사양을 계산할 수 있다. 이러한 온 칩 DFT 회로는 GSM, Bluetooth 및 IEEE802g 표준에 이용할 수 있는 3가지 주파수 대역, 즉 1.8GHz, 2.4GHz, 5.25GHz용 LNA에서 사용할 수 있도록 자체적으로 프로그램 할 수 있다. 이 회로는 간단하면서도 저렴하다

X-선 회절 장비의 기계적 오차 수정을 통한 분석 정확도 향상 (Improvement of Measurement Accuracy by Correcting Systematic Error Associated with the X-ray Diffractometer)

  • 최두호
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.97-101
    • /
    • 2017
  • X-선 회절기(X-ray diffractometer)는 시편에서 회절되는 회절빔을 이용하여 재료의 상 (phase), 집합조직 (texture), 격자상수 (lattice constant), 잔류응력 (residual stress) 등 다양한 재료물성을 분석하는 데 광범위하게 사용되는 장치이다. X-선을 이용한 정량적인 분석은 회절빔의 피크 위치를 바탕으로 수행되는 데, 장시간 X-선 회절기를 사용하게 되면 필연적으로 장치 부품에 미세 변형이 발생하게 되고, 이러한 기계적인 오차가 발생하면 정량적인 분석의 정확도가 떨어지게 된다. 본 연구에서는 미국 표준기술연구소 (National Institute of Standards and Technology, NIST)에서 제공된 잔류응력이 없는 Si 파우더를 이용하여 $2{\theta}$를 기준으로 약 30~90도 사이 구간에 대해 X-선 회절 실험을 수행하였고, NIST에서 제공된 회절빔의 피크 위치와의 비교를 통하여 X-선 회절기의 계통오차를 파악하였으며, 이러한 오차 교정이 진격자상수 (true lattice constant) 측정 등 정량적인 분석에 미치는 영향을 확인하기 위하여 잔류응력이 존재하는 180 nm 두께의 텅스텐 박막에 대한 X-선 회절 분석을 수행하였다.

Purity assignment of 17β-estradiol by mass balance method

  • Lee, Hwa-Shim;Oh, Kwang-Hoon
    • 분석과학
    • /
    • 제30권5호
    • /
    • pp.226-233
    • /
    • 2017
  • In general, quantitative chemical analysis in various areas including food, the environment, in vitro diagnostics, etc., requires traceability in order to increase the reliability of the measurements. Measurement traceability is a property of an unbroken chain of comparisons relating an instrument's measurements to SI units. Purity analysis is the first process for establishing traceability to SI units in chemical measurements. The purpose of this study is to develop and validate a method of purity assignment for establishing the traceability of $17{\beta}$-estradiol measurements in an in vitro diagnostics field. The establishment of this method is very important as it can be applied to the development of CRM and to the analysis of the purity of other hormones. The method of assignment of the purity of $17{\beta}$-estradiol was developed using the mass balance method and was validated through participation in an International comparison. In the mass balance method, impurities are categorized into four classes as follows: total related structure impurities, water, residual organic solvents, and nonvolatiles/inorganics. In this study, total related structure impurities were characterized by a gas chromatography-flame ionization detector (GC-FID) and a high-performance liquid chromatography-ultraviolet (HPLC-UV) detector, water content was determined by a Karl-Fisher coulometer, and total residual solvents and nonvolatiles/inorganics were checked simultaneously by thermogravimetric analysis (TGA). The purity of the $17{\beta}$-estradiol was 985.6 mg/g and the expanded uncertainty was 2.1 mg/g at 95% confidence. The developed method can be applied to the development of certified reference materials, which play a critical role in traceability.

최저임금의 고용효과에 관한 연구의 문제점과 개선방향 (Problems and Improvements in Research on the Employment Effect of Minimum Wage)

  • 박철호;강상구
    • 디지털융복합연구
    • /
    • 제16권10호
    • /
    • pp.145-153
    • /
    • 2018
  • 최근 우리 사회는 최저임금의 인상폭을 둘러싸고 극심한 갈등을 겪고 있으며, 이에 대해 학계는 신뢰할만한 연구를 통해 적정한 기준을 제시하지 못하고 있다. 본 연구는 최저임금의 고용효과에 관한 기존 국내외 연구들의 경향과 문제점들을 살펴보고 개선방향을 제시하였다. 자연실험 또는 메타회귀분석법을 활용하는 최근의 해외 연구들은 최저임금의 인상이 고용량에 거의 영향을 미치지 못한다는 연구결과를 제시한다. 국내 연구들은 아직 그 수효가 많지 않을 뿐만 아니라 사용된 자료나 분석기간, 연구모형 등에 따라 고용효과에 대해 서로 다른 결론을 제시한다. 향후 연구에서는 자료수집 시 임금과 근로시간 등의 오차를 최소화하고, 최저임금 변화의 내생성 문제, 경제상황과 고용변화의 추세를 적절히 고려하여 최저임금의 고용효과를 측정해야 하며, 해외 연구들에처럼 최저임금의 인상시기를 전후한 자연실험 방법을 적극 활용할 필요가 있다.

유방촬영용 X선 진단장치에서 IEC 60601-2-45 표준규격을 적용한 직선성 평가 (Evaluation of Linearity Air Kerma Applied to the IEC 60601-2-45 Standard in Mammographic X-ray)

  • 홍동희;정홍량;임청환;한범희;한상현;이상호;모은희;김기정;이미화;유인규
    • 디지털융복합연구
    • /
    • 제12권3호
    • /
    • pp.339-344
    • /
    • 2014
  • 현재 우리나라 유방촬영장치의 정도관리 항목에는 국제규격에서 원하는 직선성이 빠져있다. 직선성은 방사선량 및 방사선질의 조정을 위한 요구사항이다. 본 연구에서는 유방촬영장치 5대를 대상으로 IEC 60601-2-45 규격에 맞는 직선성을 시험한 결과 모두 적합한 결과를 보였으며 앞으로 좀 더 발전된 정도관리를 위해서는 지속적인 측정관리가 필요하다.

석탄회 및 폐타이어의 성토재로의 적용성 검토를 위한 현장시험 (Field Tests for the Application of Bottom Ash and Shred Tire as Fill Materials)

  • 이성진;이태윤
    • 한국지반환경공학회 논문집
    • /
    • 제14권10호
    • /
    • pp.29-37
    • /
    • 2013
  • 본 연구에서는 석탄회 2종류, 석탄회와 폐타이어 혼합재료, 일반 풍화토 등 4가지 재료에 대해 현장에 시험성토체를 조성하고 1년 동안의 장기 모니터링을 통해 성토체 거동 특성 및 수질 영향을 분석하였다. 지반공학적 측면에서 재료별로 변형 거동의 차이는 보이지 않았으며, 동절기에도 성토체 내부의 동결로 인한 석탄회 재료의 강도감소 가능성은 낮은 것으로 판단되었다. 또한 성토체에서의 침하도 관측되지 않았는데 이는 성토체 하부 지반이 장기적인 압밀침하가 발생할 정도로 연약한 상태가 아니기 때문으로 판단된다. 수질 영향 평가에서는 분석된 모든 중금속과 황산염을 제외한 음이온들이 국내외 먹는물 기준치 이하로 검출되었다. 황산염의 경우 성토체 설치 후 모든 성토체에서 20일 동안 기준치를 초과하는 농도로 검출되었으나, 그 이후 급격히 감소하여 50일 이후 기준치 이하로 검출되었으며, 60일 이후에는 더 이상 검출되지 않았다.

표면부착된 분포형 광섬유 센서의 유한요소해석 (FEM Analysis of Distributed Optical Fiber Sensors for the Strain Transfer)

  • 김상훈;이정주;권일범;허증수
    • 센서학회지
    • /
    • 제10권1호
    • /
    • pp.16-23
    • /
    • 2001
  • 국부적인 측정을 수행하는 일반적인 광섬유 센서에 비해 분포형 광섬유 센서는 광섬유의 길이방향을 따라 모든 위치에서 측정이 가능하며 보다 넓은 영역의 측정을 수행할 수 있다. 브릴루인 산란 분포형 광섬유 센서를 구조물의 건전성 감시에 이용할 때에는 광섬유 센서의 일반적인 부착 방법인 에폭시를 이용한 표면부착 방법을 사용하게 된다. 본 논문에서는 에폭시를 이용하여 브릴루인 분포형 광섬유 센서를 구조물의 표면에 부착하였을 때 구조물의 변형률 변화를 광섬유 센서가 정확히 측정해 낼 수 있는지에 대해 유한요소법을 통한 검증을 수행하였다. 구조물로부터 에폭시, 광섬유 코팅, 클래딩을 통해 코어로 전달되는 변형률의 전달률을 해석을 통해 확인하였으며 변형률 분포로부터 에폭시 끝 단의 자유 경계면이 미치는 영향을 살펴보았다.

  • PDF

핵연료 건전성 점검을 위한 감마선 스펙트럼의 자동 분석 (Automatic Analysis of Gamma Ray Spectra for Surveillance of the Nuclear Fuel Integrity)

  • Cho, Joo-Hyun;Yu, Sung-Sik;Kim, Seong-Rae;Hah, Yung-Joon
    • Nuclear Engineering and Technology
    • /
    • 제26권4호
    • /
    • pp.555-561
    • /
    • 1994
  • 핵연료 건전성 점검을 위하여 다중채널분석기로 얻은 감마선 스펙트럼을 자동으로 빨리 분석하는 프로그램을 개발하였다. 핵연료의 건전성은 실시간 감시와 주기적인 시료 분석을 통한 원자로냉각재내의 방사선준위로 확인된다. 영광 3·4 호기의 경우, 실시간 감시 계통인 프로세스 방사선 감시 계통(PRMS)이 핵연료의 건전성을 확인한다. 현재, PRMS의 스펙트로미터 채널의 신호처리기는 단일채널 분석기이어서 오직 하나의 방사성핵종만을 파악할 수 있다. 따라서 PRMS를 개선하기 위해서는 단일채널분석기를 다중채널분석기로 대치하여야 한다. 이 프로그램은 실시간 모드와 수동모드로 실행되며, 모든 과정을 자동으로 수행한다. 미 국가표준국의 혼합 표준 선원에 대한 시험 결과는 상용 다중채널분석기인 Canberra System 100의 결과와 잘 일치하였다. 결론적으로 개발된 프로그램은 원자력발전소의 감마선 감시에 사용할 수 있을 것으로 보인다.

  • PDF

BRICS 국가별 평생교육체제 강점 및 약점 분석연구 (Analysis of Strength and Weaknesses in Lifelong Learning System of BRICS)

  • 김주석
    • 한국콘텐츠학회논문지
    • /
    • 제21권11호
    • /
    • pp.414-425
    • /
    • 2021
  • 본 연구의 목적은 BRICS 국가들의 평생교육체제의 경쟁력을 측정하고 분석하는 것이다. 이를 위해 기존 개발도상국의 NLLS 시스템을 측정하기 위해 개발된 메커니즘 모형 및 32개의 지표와 12개의 하위요소를 측정에 이용하였다. GLLI(Global Lifelong Learning Index) 측정결과, 중국과 러시아가 상대적으로 강세를 나타냈고, 브라질, 남아공이 중간그룹을 형성하였다. 인도는 상대적으로 가장 낮은 점수를 기록하였다. 그러나 국가마다 중점을 두어야 할 평생교육 분야가 있으며, 본 연구에서는 각 BRICS 국가들의 평생학습 체제의 강점 및 약점을 비교분석하였다. 본 연구는 평생교육과 관련된 정책을 평가하고 NLLS 경쟁력을 높이기 위한 의사 결정의 준거 및 BRICS 국가의 NLLS 현황을 알 수 있는 기초자료로 활용될 것으로 기대된다.