• Title/Summary/Keyword: National Facility

Search Result 2,916, Processing Time 0.034 seconds

CLINICAL CHARACTERISTICS OF CHILD AND ADOLESCENT PSYCHIATRIC INPATIENTS WITH PERVASIVE DEVELOPMENTAL DISORDER (입원한 전반적발달장애 소아청소년의 임상특성)

  • Pyo, Kyung-Sik;Bahn, Geon-Ho;Hong, Kang-E;Park, Tae-Won
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.9 no.2
    • /
    • pp.237-246
    • /
    • 1998
  • Objectives and Methods:This study investigated clinical characteristics, treatment modality, outcome of 57 children and adolescent inpatients(male 53, female 4) who were diagnosed as pervasive developmental disorder(PDD) by DSM-Ⅳ criteria recent five years. Results:1) The mean age at admission was $96{\pm}28.2$ months, and the mean age at which they first visited treatment facility was $52{\pm}26.6$ months. The mean hospitalization period was $43.7{\pm}31.3$ days. 2) Diagnosis:Twenty-seven(47.4%) of subjects met DSM-Ⅳ criteria for PDD NOS. Fifteen (26.3%) met for autistic disorder, nine(15.8%) met for Asperger's syndrome, and two(3.5%) met for childhood disintegrative disorder. 3) Comorbid diagnosis:The most common comorbid dignosis was attention deficit hyperactivity disorder(23.8%). 4) IQ test:IQ test for twenty-eight subjects was possible. The Average of the subjects was $70{\pm}27.5$. Fifteen(53.6%) of the subjects were approximate or under 70. 5) Neurology Abnormality:EEG findings of eleven(21.2%) subjects were abnormal, brain CT or MRI findings of eight subjects(21.6%) were abnormal. 6) Family Hx:Depressive disorder were found in Eight mothers(14%). Familial loading was found in twenty families(35.1%), and familial loading of PDD was found in three(5.3%). Conclusion:The most important thing for the management of PDD is early detection and early treatment. To do so, multidisciplinary team approach should be emphasized.

  • PDF

OBSTETRICIAN'S VIEW OF TEENAGE PREGNANCY:PRESENT STATUS, PREVENTION AND PSYCHIATRIC CONSULTATION (산과 의사가 인지한 10대 임신의 현황, 예방, 정신과 자문)

  • Kim, Eun-Young;Kim, Boong-Nyun;Hong, Kang-E;Lee, Young-Sik
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.13 no.1
    • /
    • pp.117-128
    • /
    • 2002
  • Objectives:For the purpose of obtaining the more vivid present status and prevention program of teenage pregnancy, this survey was done by Obstetricians, as study subject, who manage the pregnant teenager in real clinical situation. Methods:Structured survey form about teenage pregnancy was sent to 2,800 obstetricians. That form contained frequency, characteristics, decision making processes, and psychiatric aspects of the teenage pregnancy. 349 obstetricians replied that survey form and we analysed these datas. Results:(1) The trend of teenage pregnancy was mildly increased. (2) The most common cases were unwanted pregnancy by continuing sexual relationship with boyfriends rather than by forced, accidental sexual relationship with multiple partners. (3) The most common reason of labor was loss the time of artificial abotion. (4) Problems of pregnant girls' were conduct behaviors and poor informations about contraception rather than sexual abuse or mental retardation. (5) Most obstetricians percepted the necessity of psychiatric consultation, however psychiatric consultation was rare due to parents refusal and abscense of available psychiatric facility. (6) For the prevention of teenage pregnancy, the most important thing was practical education about contraception. Conclusions:Based on the result of this study, further study using structured interview schedule with pregnant girl is needed for the detecting risk factor of teenage pregnancy and effective systematic approach to pregnant girl.

  • PDF

A Review of the Supreme Court Decision on Damages for the Airport Noise (항공기소음피해에 대한 국가배상판결에 대한 고찰)

  • Chae, Young-Geun
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.20 no.1
    • /
    • pp.211-253
    • /
    • 2005
  • Recently, the Korean Supreme Court released two important decisions concerning damages for the pain and suffering from Aircraft noise. The local people who are living near the Air Force practice site at Maehyang-ri and the Kimpo International Airport brought lawsuits against the Korean government requesting damages for their financial loss from the severe noise and the damages for their pain and suffering. Plaintiffs alleged that they suffered physical malfunctions, extreme disturbances and the reduction of property values from the extreme noises which were daily repeated. District Court of Seoul Province did not allow plaintiffs all but the damages for pain and suffering. Plaintiffs could not prove the causation between their financial loss and the noise. The Supreme Court confirmed the lower court's decision. Article V of the National Compensation Act (analogous to the Federal Tort Claims Act of the USA) reads, "the government shall be liable for any loss caused by the defect on establishment or maintenance of public facilities." In the two cases, the major issue was whether the government's establishment or maintenance of Air Force practice site and the airport was defective because they caused serious noise to surrounding neighbors. Previously, the Supreme Court interpreted the clause "defect on establishment or maintenance of public facilities" as failure of duty to provide safety measures to the degree generally required to ordinary manager. However the Court at this time interpreted differently that the defect could be found if the facility caused to any person loss to the degree intolerable. In the two cases the Court confirmed the lower court's finding that noise level at the site was severe enough to be intolerable. This standard is based on the severity of the loss rather than the failure of duty. It became easier for plaintiffs to prove the cause of action under this interpretation. The consequence of the ruling of these two cases is 'rush to the courtroom' by the local people at similar situations. The ruling of these two cases was not appropriate both in theory and in consequence. The Korean tort system is basically based on the theory of negligence. Strict liability is exceptional only when there is special legislation. The Court created strict liability rule by interpreting the Art. V of the National Compensation Act. This is against the proper role of the court. The result of the cases is also dismal. The government was already sued by a number of local people for damages. Especially the Department of Defense which is operating many airports nationwide has financial hardship, which will cause downsizing military practice by the Air Force in the long run, This is no good to anyone. Tens of millions of dollars which might be used for compensation might be better used to prevent further noise problem surrounding airports.

  • PDF

Analysis of Structural Types and Design Factors for Fruit Tree Greenhouses (과수재배용 온실의 구조유형과 설계요소 분석)

  • Nam, Sang-Woon;Ko, Gi-Hyuk
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • In order to provide basic data for the development of a controlled environment cultivation system and standardization of the structures, structural status and improvement methods were investigated for the fruit tree greenhouses of grape, pear, and peach. The greenhouses for citrus and grape cultivation are increasing while pear and persimmon greenhouses are gradually decreasing due to the advance of storage facilities. In the future, greenhouse cultivation will expand for the fruit trees which are more effective in cultivation under rain shelter and are low in storage capability. Fruit tree greenhouses were mostly complying with standards of farm supply type models except for a pear greenhouse and a large single-span peach greenhouse. It showed that there was no greenhouse specialized in each species of fruit tree. Frame members of the fruit tree greenhouses were mostly complying with standards of the farm supply type model or the disaster tolerance type model published by MIFAFF and RDA. In most cases, the concrete foundations were used. The pear greenhouse built with the column of larger cross section than the disaster tolerance type. The pear greenhouse had also a special type of foundation with the steel plate welded at the bottom of columns and buried in the ground. As the results of the structural safety analysis of the fruit tree greenhouses, the grape greenhouses in Gimcheon and Cheonan and the peach greenhouses in Namwon and Cheonan appeared to be vulnerable for snow load whereas the peach greenhouse in Namwon was not safe enough to withstand wind load. The peach greenhouse converted from a vegetable growing facility turned out to be unsafe for both snow and wind loads. Considering the shape, height and planting space of fruit tree, the appropriate size of greenhouses was suggested that the grape greenhouse be 7.0~8.0 m wide and 2.5~2.8 m high for eaves, while 6.0~7.0 m wide and 3.0~3.3 m of eaves height for the pear and peach greenhouses.

A Study on Effective Plans for Increasing Urban Parks through an Analysis of Areas with Park Shortages - Gangneung - (공원부족구역 분석을 통한 도시공원 확충방안 연구 - 강릉시를 대상으로 -)

  • Lee, Jae-Young;Kim, Tae-Kyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.3
    • /
    • pp.1-9
    • /
    • 2011
  • The purpose of this study is to propose plans to increase the number of urban parks as a way to help absorb carbon in order to implement the low carbon green city goals of Gangneung. As a study method, park incentive areas and current park areas were set as parameters and the areas of lacking in park space were categorized according to each indicator. The degree of park shortage was classified by overlapping the park shortage areas. Once the areas needing parks were assessed according to priority, target sites were selected on sites where construction would be actually possible. First, results of analysis showed that Songjeong-Dong and Seongdeok-Dong to the east of the target site lacking park space due to old residences and high population density or industrial use areas, were the most severe in the degree of park shortage. It was also shown that areas with high population density and park shortages included the Ponam-Dong, Okcheon-Dong and Hongje-Dong areas. Accordingly, the east side of the target areas and Hongje-Dong were both considered as high-priority areas needing to increase park space and actual possible target sites were selected for the creation of new, small parks in industrial areas by creating parks in school yards, in facility relocation sites and legal reviews. In addition, analysis indicators of park shortages were re-evaluated according to the securing of the park and it was shown that the problems in park shortages were resolved with the proper positioning of parks. In addition, satisfaction in the area of park per person, $3m^2$ was at a higher than a certain level in all areas except Songjeong-Dong, demonstrating that the park areas were evenly distributed. Areas of park shortage were shown in part of Songjeong-Dong and Seongdeok-Dong. This could be resolved by using alternative park resources such as the adjacent Gyeongpo Provincial Park, the beach and Namdaecheon.

Demonstration-scale Offshore CO2 Storage Project in the Pohang Basin, Korea (포항분지 해상 중소규모 CO2 저장 실증연구)

  • Kwon, Yi Kyun
    • The Journal of Engineering Geology
    • /
    • v.28 no.2
    • /
    • pp.133-160
    • /
    • 2018
  • $CO_2$ storage is a very important technology for reduction of greenhouse gas emissions and has been considered as almost the only viable and effective option for immediate large-scale $CO_2$ sequestration. Small-scale demonstration project for offshore $CO_2$ storage in the Pohang Basin is the transitional stage R&D program for technological preparation of large-scale $CO_2$ storage project in Korea. Through the extensive exploration research for prospective $CO_2$ storage sites, the offshore strata in the Pohang Basin was recommended for the storage formation of the small-scale demonstration project. The Pohang Offshore Storage Project launched at 2013, and has accomplished the technical demonstration and technological independence in a wide range of $CO_2$ storage technology, such as geophysical exploration, storage site characterization, storage design, offshore platform construction, injection-well drilling and completion, deployment of injection facility, operation of $CO_2$ injection, and $CO_2$ monitoring. The project successfully carried out $CO_2$ test injection in early 2017, and achieved its final goal for technical development and demonstration of $CO_2$ storage in Korea. The realization of $CO_2$ injection in this project is the measurable result and has been recorded as the first success in Korea. The Pohang Offshore Storage Project has a future plan for the continuous operation of $CO_2$ injection and completion of $CO_2$ monitoring system. The project has provided in-house technical and practical expertises, which will be a solid foundation for the commercial-scale $CO_2$ storage business in Korea. Additionally, the project will help to secure national technical competitiveness in growing international technology market for $CO_2$ storage.

An analytical study on the fire characteristics of the small tunnel with large smoke exhaust port (대배기구 배연방식을 적용한 소형차 전용 터널의 화재특성에 관한 해석적 연구)

  • Yoo, Ji-Oh;Kim, Jin-Su;Rhee, Kwan-Seok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.375-388
    • /
    • 2017
  • In order to solve the traffic congest and environmental issues, small-cross section tunnel for small car only is increasing, but there is not standard for installation of disaster prevention facility. In this study, in order to investigate the behavioral characteristics of thermal environment and smoke in a small cross section tunnels with a large port exhaust ventilation system, the A86, the U-Smartway and the Seobu moterawy tunnel, Temperature and CO concentration in case of fire according to cross sectional area, heat release rate and exhaust air flow rate were analyzed by numerical analysis and the results were as follows. As the cross-sectional area of the tunnel decreases, the temperature of the fire zone increases and the rate of temperature rise is not significantly affected by heat release rate. However, there is a difference depending on the change of the exhaust air flow rate. In the case of applying the exhaust air flow rate $Q_3+2.5Ar$ of the large port exhaust ventilation system, the temperature of the fire zone was 7.1 times for A86 ($Ar=25.3m^2$) and 5.4 time for U-smartway ($Ar=37.32m^2$) by Seobu moterway tunnel ($Ar=46.67m^2$). The CO concentration of fire zone also showed the same tendency. The A86 tunnels were 10.7 times and the U-Smartways were 9.5 times more than the Seobu moterway. Therefore, in the case of a small section tunnel, the thermal environment and noxious gas concentration due to the reduction of the cross-sectional area are expected to increase significantly more than the cross-sectional reduction rate.

Intracellular Lipid Accumulation Inhibition, Anticancer Activity, and Single Oral Dose Toxicity of Ethanolic Wolfiporia cocos Extracts (에탄올 복령추출물의 지방축적 억제활성, 항암활성 및 단회 경구 독성시험)

  • Park, Na-Hye;Lee, Hwa-Yong;Choi, Jong-Woon;Park, Seung-Chun
    • The Korean Journal of Mycology
    • /
    • v.46 no.3
    • /
    • pp.295-306
    • /
    • 2018
  • In the present study, we compared the effects of 50% ethanolic extracts of Chinese and Korean Wolfiporia cocos (CPE and KPE) on in vitro lipid accumulation in 3T3-L1 cells and their anticancer activities in Sarcoma 180 cells. We further compared the anticancer activities and the 50% inhibitory concentrations ($IC_{50}$) of CPE with KPE with cultivated for one and two years in a landfill and a facility (LPE and FPE), respectively. In addition, the single oral dose toxicities of CPE and KPE were evaluated in mice. Lipid accumulation was inhibited after 48 hours, in CPE and KPE treated 3T3-L1 cells; however, no significant difference was observed between CPE and KPE in their lipid accumulation inhibitory activities. The anticancer activity of KPE was higher than that of CPE at $300{\mu}g/mL$ (p<0.05), revealing the possibility of an auxiliary biological means for origin identification. The anticancer activities of LPE and FPE were significantly stronger than that of CPE (p<0.05) but there was no difference between extracts from one- and two-year-old W. cocos, irrespective of the cultivation method. In single oral dose toxicity tests, CPE and KPE did not induce mortality during the 14-day observation. Thus, the 50% of lethal dose ($LD_{50}$) of CPE and KPE were estimated to be higher than 2,000 mg/kg. Taken together, our results indicate that the anticancer assay could be an auxiliary means of identifying the origin of W. cocos. In addition, artificial cultivation could be an alternative way to reduce the import of W. cocos. Lastly, 50% ethanolic W. cocos extracts could be potential candidates for obesity and cancer managements.

A Study on Environmental Standards of School Building (교사환경기준에 관한 연구)

  • Hong, Seok-Pyo;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.1
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

Evaluation and Improvement Measures on the Status of the Installation and Operation of Facilities for Recycling Food Waste into Resources (음식물 자원화시설의 설치·운영에 대한 일반현황의 평가 및 개선 방안)

  • Ryu, Ji-Young;Kong, Kyu-Sik;Shin, Dae-Yewn;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.3
    • /
    • pp.63-75
    • /
    • 2004
  • This research sought to determine the status of the installation and operation of domestic public resource-making facilities of resource-making facilities and come up with corresponding improvement measures. Currently compost is most numerous set-up out of facilties already established ever since, then the rest of them are feeds, anaerobic degradation, sewage combination, and combination of compost and feeds in order. As such, food waste is processed more into compost than into feeds, presumably because relevant facilities, which were originally designed for processing into feeds, were converted into composting facilities due to little demand for the processed feeds. The finding says that many related firms had yet to register their businesses in accordance with feeds and fertilizers management laws, and that food waste resources-making facilities used various basic facilities but few of them treated food waste in linkage with leaching water, bad odors, and energy. Some of current facilities were found to be 7 years old and thus outdated. Due to lack of skilled operational manpower, many facilities had less than 300 days of normal operation yearly, and some needed minor and serious repairs periodically. In overall facilities, 87% of the planned food waste was rolled in, thus requiring measures to treat the whole planned volume. For costs of resource-making facilities, some with a capacity of below 50 tons topped 100 million won, and facilities with a capacity of over 50 tons required less installation costs. Overall, installation costs ranged from 10 million to 20 million, and to 200 million won per ton, and this suggests a need to establish the installation cost calculation criteria, as well as to reshape the facility criteria. With operating costs varying greatly according to the size and treatment methods of facilities, the finding indicates a need to rationalize the operating costs, and to plan appropriate-size installation and operation of facilities to ensure economic operation.

  • PDF