• Title/Summary/Keyword: National Control Point

Search Result 1,789, Processing Time 0.03 seconds

Knowledge on Infection Control for Home Care (가정간호과정생의 가정간호에서의 감염관리에 대한 지식)

  • Jeong, Ihn-Sook;Jeong, Jae-Shim;Shin, Yong-Ae;Kang, Kyu-Sook;Kim, Myung-Ja;Jo, Bok-Hee;Kim, Keum-Soon;Hwang, Sun-Kyng
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.9 no.1
    • /
    • pp.5-13
    • /
    • 2002
  • This study was conducted to assess need for education on the infection control by examining the knowledge on infection control in home care of the home care trainees who had completed an infection control course. Using 64 items questionnaire. home care trainees of eight home care education institutions who took classes related with infection control. The level of knowledge evaluated subjectively was 4.24point (full mark: 5 point). The correct answer rates for handwashing and gloving. cleaning patients' rooms. preventing sharp injury, preventing exposure to potential infectious agents, home care bag technique were 84.5% 86.4% 70.7% 65.3% 76.2% representatively. For the knowledge on the infection control principles to prevent catheter related infection, indwelling catheter related infection, tracheal tube related pneumonia. L-tube related infection, oxygen therapy related infection. and wound infection were 62.8% 27.8% 39.1% 87.8% 76.5% 80.5% representatively. The correct answer rates varied depending upon the educational institutes (p< = .0001), educational levels (p= .001), workplaces (p<.0001), and the experience of infection control education (p= .001). Considering these results. a standardized curriculum must be developed and implemented after analyzing the existing infection control curricula of the home care education institutes. and guide books for infection control in home care should be developed and distributed. In addition. continuous infection control education be provided to the home care nurses through reeducation so they can acquire new knowledge needed for carrying out infection control activities effectively.

  • PDF

COMMON FIXED POINT THEOREM IN FUZZY METRIC SPACE USING CONTROL FUNCTION

  • Kumar, Amit;Vats, Ramesh Kumar
    • Communications of the Korean Mathematical Society
    • /
    • v.28 no.3
    • /
    • pp.517-526
    • /
    • 2013
  • We give a fixed point theorem for complete fuzzy metric space which generalizes fuzzy Banach contraction theorems established by V. Gregori and A. Spena [Fuzzy Sets and Systems 125 (2002), 245-252] using notion of altering distance, initiated by Khan et al. [Bull. Austral. Math. Soc. 30 (1984), 1-9] in metric spaces.

Improved P&O algorithm for rapidly changing insolation (일사량 급변에 대한 P&O 알고리즘의 개선)

  • kang A, J.;Kim T. W.;Kim H. S.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.117-120
    • /
    • 2004
  • As the maximum power operating point (MPOP) of photovoltaic (PV) power generation systems changes with varying atmospheric conditions such as solar radiation and temperature, an important consideration in the design of efficient PV system is to track the MPOP correctly. Although the efficiency of these Maximum Power Point Tracking algorithms is usually high, it drops noticeably in case of rapidly changing atmospheric conditions. This paper describes common MPPT control algorithm: Constant Voltage Control, Perturbation and Observation(P&O), Incremental Conductance (IncCnd) and proposes a new MPPT algorithm based on P&O algorithm. The conception and control principles of the proposed MPPT method are explained in detail and its validity of the proposed method is verified through several simulated results. As it doesn't use digital signal processor, this MPPT method has the merits of both a cost efficiency and a simple control circuit design. Therefore, it is considered that the proposed MPPT method is proper to low power, low cost PV applications.

  • PDF

A New Solar Energy Conversion System Implemented using Single Phase Inverter (새로운 방식의 단상 인버터를 이용한 태양광 시스템 구현)

  • Hong Jeng-Pyo;Kim Tae-Hwa;Won Tae-Hyun;Kwon Soon-Jae;Hong Soon-Ill;Kim Jong-Dal
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.488-491
    • /
    • 2006
  • In this paper proposed method of maximum power point tracking using boost converter for a connected single phase inverter with photovoltaic system. The maximum power point tracking control is based on generated circuit control MOSFET switch of boost converter and single phase inverter uses predicted current control to control four IGBT's switch in full bridge. The predicted current control provide current with sinusoidal wave shape and inphase with voltage. The generation control circuit allows each photovoltaic module to operate independently at peak capacity, simply by detecting of the output power of the system. Furthermore, the generation control circuit attenuates low-frequency ripple voltage, which is caused by the full-bridge inverter, across the photovoltaic modules. Consequently, the output power of system is increased due to the increase in average power generated by the photovoltaic modules. The effectiveness of the proposed inverter system is confirmed experimentally and by means of simulation.

  • PDF

Voltage Control for a Wind Power Plant Based on the Available Reactive Current of a DFIG and Its Impacts on the Point of Interconnection (이중여자 유도형 풍력발전기 기반 풍력단지의 계통 연계점 전압제어)

  • Usman, Yasir;Kim, Jinho;Muljadi, Eduard;Kang, Yong Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.23-30
    • /
    • 2016
  • Wake effects cause wind turbine generators (WTGs) within a wind power plant (WPP) to produce different levels of active power and subsequent reactive power capabilities. Further, the impedance between a WTG and the point of interconnection (POI)-which depends on the distance between them-impacts the WPP's reactive power injection capability at the POI. This paper proposes a voltage control scheme for a WPP based on the available reactive current of the doubly-fed induction generators (DFIGs) and its impacts on the POI to improve the reactive power injection capability of the WPP. In this paper, a design strategy for modifying the gain of DFIG controller is suggested and the comprehensive properties of these control gains are investigated. In the proposed scheme, the WPP controller, which operates in a voltage control mode, sends the command signal to the DFIGs based on the voltage difference at the POI. The DFIG controllers, which operate in a voltage control mode, employ a proportional controller with a limiter. The gain of the proportional controller is adjusted depending on the available reactive current of the DFIG and the series impedance between the DFIG and the POI. The performance of the proposed scheme is validated for various disturbances such as a reactive load connection and grid fault using an EMTP-RV simulator. Simulation results demonstrate that the proposed scheme promptly recovers the POI voltage by injecting more reactive power after a disturbance than the conventional scheme.

ROBUST BOUNDARY CONTROL OF CHEMOTAXIS REACTION DIFFUSION SYSTEM

  • Ryu, Sang-Uk;Kang, Yong Han
    • Korean Journal of Mathematics
    • /
    • v.16 no.4
    • /
    • pp.457-470
    • /
    • 2008
  • This paper is concerned with the robust boundary control of the chemotaxis reaction diffusion system. That is, we show that the existence of the saddle point for the robust control problem when the control and the disturbance are given by the boundary condition.

  • PDF

A Novel Voltage Control MPPT Algorithm using Variable Step Size based on P&O Method (가변 스텝 P&O 기반 전압제어 MPPT 알고리즘에 관한 연구)

  • Kim, Jichan;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.1
    • /
    • pp.29-36
    • /
    • 2020
  • In this study, a variable step algorithm is proposed on the basis of the perturb and observe method. The proposed algorithm can follow the maximum power point (MPP) quickly when solar irradiance changes rapidly. The proposed technique uses the voltage change characteristic at the MPP when the environment changes because of insolation or temperature. The MPP is tracked through the voltage control using a variable step method. This method determines the sudden change of solar irradiance by setting the threshold value and operates in fast tracking mode to track the MPP rapidly. When the operation point reaches the MPP, the mode switches to the variable step mode to minimize the steady state error. In addition, the output disturbance is decreased through the optimization of the control method design. The performance of the proposed MPPT algorithm is verified through simulation and experiment.

An Investigation of Robot Programming Language with the Capabilities of Sensory Information Processing (센서 정보 처리 기능을 갖는 로보트 프로그램밍 언어에 관한 조사)

  • Kim, Dae-Won;Ko, Myoun-Sam;Lee, Bum-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.435-438
    • /
    • 1987
  • In this paper, among the robot programming languages that enable processing of sensory information, eight exemplary languages are chosen, and investigated in terms of their characteristics, why they are designed the way they are, and the kind of sensors each language can use and apply to. In addition, the characteristics of each language is compared with one another from the sensor point of view and the flow of each language is analyzed from the robot language classification point of view. Finally, We investigate the progress and the requirements of the sensor-based robot programming languages for further developments.

  • PDF

DESIGN OF A FPGA BASED ABWR FEEDWATER CONTROLLER

  • Huang, Hsuanhan;Chou, Hwaipwu;Lin, Chaung
    • Nuclear Engineering and Technology
    • /
    • v.44 no.4
    • /
    • pp.363-368
    • /
    • 2012
  • A feedwater controller targeted for an ABWR has been implemented using a modern field programmable gate array (FPGA), and verified using the full scope simulator at Taipower's Lungmen nuclear power station. The adopted control algorithm is a rule-based fuzzy logic. Point to point validation of the FPGA circuit board has been executed using a digital pattern generator. The simulation model of the simulator was employed for verification and validation of the controller design under various plant initial conditions. The transient response and the steady state tracking ability were evaluated and showed satisfactory results. The present work has demonstrated that the FPGA based approach incorporated with a rule-based fuzzy logic control algorithm is a flexible yet feasible approach for feedwater controller design in nuclear power plant applications.

A Design of Power Circuit and LCL Filter for Switching Mode PV Simulator (스위칭방식 PV Simulator의 전력회로와 LCL필터 설계)

  • Lee, Sung-Min;Yu, Tae-Sik;Kim, Hyo-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.431-437
    • /
    • 2012
  • PV simulators are essential equipment for testing power conditioning systems (PCS) which are one of an important part in PV generator systems, for testing before shipment. High dynamic PV simulator is required since MPPT(Maximum Power Point Tracking) test procedure has been established by EN50530 regulation recently. Most high quality PV simulator prevailed in the market is linear type which however has low efficiency. This paper proposes design guide lines for the power stage and LCL type filter cooperating with a switching mode PV simulator that shows high efficiency and very low power consumption. Proposed theory is verified by experiment.