• Title/Summary/Keyword: National Control Point

Search Result 1,794, Processing Time 0.033 seconds

Analysis of Nonpoint Source Pollutants in Urban Stormwater Runoff (강우시 도시지역 비점오염물질의 하천 유입 산정)

  • Son, Younggyu
    • Journal of Wetlands Research
    • /
    • v.18 no.1
    • /
    • pp.94-99
    • /
    • 2016
  • Non-point source control has been issued and intensively studied for the control of water quality in streams and rivers. In this study, non-point source pollutants monitoring was conducted at the end of five small streams which were connected to a main stream in three stages including Phase I (one hr before the rainfall), Phase II (one hr after the rainfall), and Phase III (six hrs after the rainfall). For all five small streams, the concentrations and loading rates of non-point source pollutants significantly increased due to the rainfall. As a result of this, priority control streams and priority pollutants were suggested to prepare for future plans of the non-point source control.

Comparison of Voltage Oriented Control and Direct Power Control under Command Mode Transition for PMSG Wind Turbines

  • Kwon, Gookmin;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.173-174
    • /
    • 2016
  • This paper proposes a comparison of Voltage Oriented Control (VOC) and Direct Power Control (DPC) under command mode transition for PMSG Wind Turbines (WT). Based on a neutral point clamped three level back to back type Voltage Source Converter (VSC), proposed control scheme automatically control the generated output power to satisfy a grid requirement from the hierarchical wind farm controller. Automatic command mode transition based on the dc-link voltage error provides a command mode changing between grid command and MPPT mode. It is confirmed through PLECS simulations in Matlab. Simulation result shows that proposed control scheme of VOC and DPC achieves a much shorter transient time of generated output power than the conventional control scheme of MPPT with optimal torque control and VOC under a step response. The proposed control scheme makes it possible to provide a good dynamic performance for PMSG wind turbines in order to generate a high quality output power.

  • PDF

Test and Estimation for Normal Mean Change

  • Kim, Jae-Hee;Ryu, Jong-Eun
    • Communications for Statistical Applications and Methods
    • /
    • v.13 no.3
    • /
    • pp.607-619
    • /
    • 2006
  • We consider the problem of testing the existence of change in mean and estimating the change-point when the data are from the normal distribution. A change-point estimator using the likelihood ratio test statistic, Gombay and Horvath (1990) test statistic, and nonparametric change-point estimator using Carlstein (1988) empirical distribution are studied when there exists one change-point in the mean. A power study is done to compare the change test statistics. And a comparison study of change-point estimators for estimation capability is done via simulations with S-plus software.

HACCP in Changran Jeotgal

  • Park Mi-Yeon;Choi Seung-Tae;Chang Dong-Suck
    • Fisheries and Aquatic Sciences
    • /
    • v.5 no.1
    • /
    • pp.48-53
    • /
    • 2002
  • The HACCP (hazard analysis critical control point) concept becomes an important aspect of Good Manufacturing Practices (GMP) in safe food production. The HACCP plan was developed with food safety objective. The authors already carried out hazards analysis on Changran Jeotgal manufacturing process in a previous report. In this study we developed a HACCP plan on the manufacturing process of Changran Jeotgal. We could decide two CCPs those were salt concentration and eliminations of foreign materials before packaging. Foreign materials should be certainly checked out with laser detector just before packaging. Salt should be maintained more than $8\%$ to inhibit pathogenic bacteria in end product. On the Jeotgal process free water is removed after salting and Jeotgal is seasoned with several subsidiary materials such as com syrup. In result end products have $8\%$ salt with water activity 0.82. Most bacteria are inhibited but some can live in this condition. Materials on the working may be contaminate by pathogens, chemicals or physical hazards. It will be decreased by SSOP (standard sanitary operating program). The SSOP needed in Jeotgal plants is nearly same as other general food manufacturing plants but essential to fulfill HACCP program.

A Design of Programmable Low Pass Filter to Reduce the ZCP Estimation Error at High Speed BLDC Sensorless Drive (BLDC 고속 센서리스 구동의 ZCP 추정 오차 저감을 위한 Programmable Low Pass Filter 설계)

  • Seo, Eunjeong;Lee, Kangseok;Lee, Wootaik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.35-41
    • /
    • 2014
  • This paper presents a design method of programmable low pass filter(PLPF) which reduce an estimation error of a zero crossing point(ZCP) for a high speed brushless DC(BLDC) motor drive. BLDC motor sensorless drive is possible by estimation of ZCP. The ZCP estimated by detecting a change of back-EMF polarity has the estimation error because noises exist on the measured back-EMF. Therefore a calculated commutation timing using the ZCP is inaccurate. And the inexact commutation timing leads to ripples of 3-phase current and degradation of drive performance. This paper proposes the design method of the PLPF to overcome these problems. First, a speed calculated a inaccurate period of the ZCP is analyzed in the frequency domain. Then, the PLPF that has varying cut-off frequency according to change of the speed is designed on the frequency analysis result. The proposed method is verified by the experiment.

DC-Link Voltage Balance Control Using Fourth-Phase for 3-Phase 3-Level NPC PWM Converters with Common-Mode Voltage Reduction Technique

  • Jung, Jun-Hyung;Park, Jung-Hoon;Kim, Jang-Mok;Son, Yung-Deug
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.108-118
    • /
    • 2019
  • This paper proposes a DC-link voltage balance controller using the fourth-phase of a three-level neutral-point clamped (NPC) PWM converter with medium vector selection (MVS) PWM for common-mode voltage reduction. MVS PWM makes the voltage reference by synthesizing the voltage vectors that cannot generate common-mode voltage. This PWM method is effective for reducing the EMI noise emitted from converter systems. However, the DC-link voltage imbalance problem is caused by the use of limited voltage vectors. Therefore, in this paper, the effect of MVS PWM on the DC-link voltage of a three-level NPC converter is analyzed. Then a proportional-derivative (PD) controller for the DC-link voltage balance is designed from the DC-link modeling. In addition, feedforward compensation of the neutral point current is included in the proposed PD controller. The effectiveness of the proposed controller is verified by experimental results.

Application of CNN for steering control of autonomous vehicle (자율주행차 조향제어를 위한 CNN의 적용)

  • Park, Sung-chan;Hwang, Kwang-bok;Park, Hee-mun;Choi, Young-kiu;Park, Jin-hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.468-469
    • /
    • 2018
  • We design CNN(convolutional neural network) which is applicable to steering control system of autonomous vehicle. CNN has been widely used in many fields, especially in image classifications. But CNN has not been applied much to the regression problem such as function approximation. This is because the input of CNN has a multidimensional data structure such as image data, which makes it is not applicable to general control systems. Recently, autonomous vehicles have been actively studied, and many techniques are required to implement autonomous vehicles. For this purpose, many researches have been studied to detect the lane by using the image through the black box mounted on the vehicle, and to get the vanishing point according to the detected lane for control the autonomous vehicle. However, in detecting the vanishing point, it is difficult to detect the vanishing point with stability due to various factors such as the external environment of the image, disappearance of the instant lane and detection of the opposite lane. In this study, we apply CNN for steering control of an autonomous vehicle using a black box image of a car.

  • PDF

An Error Analysis of Precise Point Positioning using Ionosphere Free Combination Measurements (IF 조합 측정치를 사용하는 단독 정밀 측위 오차해석)

  • Park, Sul-Gee;Cho, Deuk-Jae;Shin, Young-Cheol;Park, Chan-Sik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.9
    • /
    • pp.871-877
    • /
    • 2012
  • An error analysis of PPP (Precise Point Positioning) using IF (Ionosphere Free) combination is given in this paper. It is shown that the performance of the ordinary model with positions, clock bias, integer ambiguities and ionosphere delay as unknowns is equivalent to that of an ionosphere difference combination where ionosphere delay is cancelled out. Furthermore, it is shown that IF combination is an ionosphere difference combination but not unique. It is also proved that all difference models show same performances. The error analysis evaluated with a hardware simulator and real measurements show that the ionosphere delay is effectively eliminated by IF combination or equivalently by the ionosphere difference combination. However, if bias errors such as troposphere, clock bias or multipath are included in the measurements, the performance of the IF combination is degraded because the bias errors are amplified by the ionosphere difference operation.

Management of Ponding Depth and Discharge Filtration from Paddy Fields for Controlling Non-point Source Pollution (논 비점오염 저감을 위한 담수위 관리와 배출수 여과의 효과 분석)

  • Choi, Yonghun;Kim, Youngjin;Kim, Seounghee;Kim, Minyoung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.125-130
    • /
    • 2015
  • Field study was carried out to assess the effect of automatic inlet and filtration outlet to reduce non-point source discharge and save agricultural irrigation water from paddy. The comparison of control and treated plots showed that irrigation water was saved up to 58 mm and discharge water was reduced up to 110 mm. The filtration outlet improved the discharge water quality for SS, COD, TN and TP up to 60.1 %, 0.1 %, 4.5 %, and 26.0 %, respectively. Overall, the findings of this study indicated that non-point source pollution discharged from paddy fields where automatic inlet and filtration outlet were installed could be reduced 266.3 kg/ha/yr in SS, 10.3 kg/ha/yr in COD, 1.22 kg/ha/yr in TN, and 0.10 kg/ha/yr in TP, respectively. This clearly showed that the automatic inlet and filtration outlet are effective management method for saving of agricultural water and protecting water environment.

Implementation of Tracking and Capturing a Moving Object using a Mobile Robot

  • Kim Sang-joo;Park Jin-woo;Lee Jang-Myung
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.3
    • /
    • pp.444-452
    • /
    • 2005
  • A new scheme for a mobile robot to track and capture a moving object using camera images is proposed. The moving object is assumed to be a point-object and is projected onto an image plane to form a geometrical constraint equation that provides the position data of the object based on the kinematics of the active camera. Uncertainties in position estimation caused by the point-object assumption are compensated for using the Kalman filter. To generate the shortest time path to capture the moving object, the linear and angular velocities are estimated and utilized. In this paper, the experimental results of the tracking and capturing of a target object with the mobile robot are presented.