• Title/Summary/Keyword: National Control Point

Search Result 1,794, Processing Time 0.036 seconds

Application of HACCP System in the Pork Industry in Korea - Review -

  • Chung, M.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.2
    • /
    • pp.253-260
    • /
    • 1999
  • Occurrences of foodborne disease outbreaks are increasing in Korea. Among the outbreaks, Salmonella, Staphylococcus aureus, Vibrio parahaemolyticus are the most important organisms and meat and meat product the major sources of infection. Hazard Analysis Critical Control Point system is a process control system designed to identify and prevent microbial and other hazards in food production. It is considered to be the best process management system by the National Advisory Committee for Microbiological Criteria for Foods, the National Academy of Science, and the Codex Alimentarius Commission. The Korean Ministry of Health and Welfare established a legal basis for the implementation of the HACCP system in Article 32-2 (Hazard Analysis Critical Control Point) of the Food Sanitation Act in December 1995. The Ministry of Agriculture and Forestry has granted research funds for the development of this model system for application to traditional food products and processed fishery products as well as to raw meats. Implementation of the HACCP system is an important step and the Korean food industry and the Government are focused on ensuring food safety in Korea.

ANN-based Maximum Power Point Tracking of PV System using Fuzzy Controller (퍼지 제어기를 이용한 PV 시스템의 ANN 기반 최대전력점 추적)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.27-32
    • /
    • 2015
  • A maximum power point tracking (MPPT) algorithm using fuzzy controller was considered. MPPT method was implemented based on the voltage and reference PV voltage value was obtained from Artificial Neural Network (ANN)-model of PV modules. Therefore, measuring only the PV module voltage is adequate for MPPT operation. Fuzzy controller is used to directly control dc-dc buck converter. The simulation results have been used to verify the effectiveness of the algorithm. The proposed method is compared with conventional PO(perturbation & observation), IC(Incremental Conductance) method. The nonlinearity and adaptiveness of fuzzy controller provided good performance under parameter variations such as solar irradiation.

Assessing Impact of Reduction of Non-Point Source Pollution by BASINS/HSPF (HSPF를 이용한 비점오염원 삭감에 따른 효과 분석)

  • Bae, Dae-Hye;Ha, Sung-Ryong
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.1
    • /
    • pp.71-78
    • /
    • 2011
  • This paper aims to assessing impact of reduction of non-point source pollution in the Bokha Stream watershed. The BASINS/HSPF model was calibrated and verified for water flow and water qualities using Total Maximum Daily Load 8days data from 2006 to 2007. Accuracy of the BASINS/HSPF models in simulating hydrology and water quality was compared and there were somewhat differences of statistical results, but water flow and water quality were simulated in good conditions over the study period. The applicability of models was tested to evaluate non-point source control scenarios to response hydrology and water quality in the Bokha stream using various measures which include BMPs approach and change of landuse. The evaluation of reduction of non-point source pollution was developed using load-duration curve. Despite strong reduction of non-point source, there are not satiated target quality at low flow season.

Improved Global Maximum Power Point Tracking Technique Using Output Characteristics of Solar Array (태양광 어레이의 출력 특성을 이용한 개선된 전역 최대전력 점 추종 기법)

  • Yoo, Koo-Hyun;Lee, Woo-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.111-117
    • /
    • 2020
  • The photovoltaic module has the characteristic that the output power varies according to the amount of insolation. If partial shading occurs in an environment composed of an array, a number of local maximum power points (LMPPs) may be generated according to the shading state. Photovoltaic arrays require global maximum power point tracking due to variations in output characteristics caused by solar radiation and temperature. Conventional algorithms, such as P&O and Incond, do not follow the global maximum power point in a partial shaded solar array. In this study, we propose a technique to follow the global maximum power point by using the correlation of voltage, current, and power in solar arrays. The proposed control technique 2qw validated through simulation and experiments by constructing a 2-kW solar system.

Detection of the Unified Control Points for RPC Adjustment of KOMPSAT-3 Satellite Image (KOMPSAT-3 위성영상의 RPC 보정을 위한 국가 통합기준점 탐지)

  • Lee, Hyoseong;Han, Dongyeob;Seo, Doochun;Park, Byungwook;Ahn, Kiweon
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.6
    • /
    • pp.829-837
    • /
    • 2014
  • The KOMPSAT-3 can acquire panchromatic stereo image with 0.7 m spatial resolution, and provides Rational Polynomial Coefficient (RPC). In order to determine ground coordinate using the provides RPC, which include interior-exterior orientation errors, its adjustment is needed by using the Ground Control Point (GCP). Several thousands of national Unified Control Points (UCPs) are established and overall distributed in the country by the Korean National Geographic Information Institute (NGII). UCPs therefore can be easily searched and downloaded by the national-control-point-record-issues system. This paper introduced the point-extraction method and the distance-bearing method to detect of UCPs. As results, the distance-bearing method was better detected through the experiment. RPC adjustment using this method was compared with that by only one UCP and GCPs using GPS. The proposed method was more accurate than the other method in the horizontal. As demonstrated in this paper, the proposed UCPs detection method could be replaced GPS surveying for RPC adjustment.

The PID Controller for Predictive control Algorithm

  • Kim, Sang-Joo;Seo, Sang-Wook;Kim, Gi-Du;Lee, Jang-Myung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.608-613
    • /
    • 2004
  • This paper is concerned with the design of a predictive PID controller, which has similar features to the model-based predictive controller. A PID type control structure is defined which includes prediction of the outputs and the recalculation of new set points using the future set point data. The optimal values of the PID gains are pre-calculated using the values of gains calculated from an unconstrained generalized predictive control algorithm. Simulation studies demonstrate the performance of the proposed controller and the results are compared with generalized predictive controller and the results are compared with generalized predictive control solutions.

  • PDF

Hourglass Control in Rigid-Plastic Finite Element Analysis (강소성 유한요소해석에서 Hourglass Control)

  • Gang, Jeong-Jin;O, Su-Ik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1290-1300
    • /
    • 1996
  • The finite element method, based on rigid-plastic formulation, is widely used to simulate metal forming processes. In order to improve the computational efficiency of the rigid-plastic FEM, one-point integration is used to evaluate the stiffness matrix with four-node rectangular elements and eight-node brick elements. In order to control the hourglass modes, hourglass strain rate components were introduced and included in the effective strain rate definition, Numerical tests have shown that the proposed one-point integration scheme reduces the stiffness matrix evaluation time without deteriorating the convergence behavior of Newton-Raphson method. Simulations of a ring compression, a plane-strain closed-die forging and the three-dimensional spike forging processes were carried out by using the proposed integration method. The simulation results are compared to those obtained by applying the conventional integraiton method in terms of the solution accuracy and computational efficiency.

Optimal National Coordinate System Transform Model using National Control Point Network Adjustment Results (국가지준점 망조정 성과를 활용한 최적 국가 좌표계 변환 모델 결정)

  • Song, Dong-Seob;Jang, Eun-Seok;Kim, Tae-Woo;Yun, Hong-Sic
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.6_2
    • /
    • pp.613-623
    • /
    • 2007
  • The main purpose of this study is to investigate the coordinate transformation based on two different systems between local geodetic datum(tokyo datum) and international geocentric datum(new Korea geodetic datum). For this purpose, three methods were used to determine seven parameters as follows: Bursa-Wolf model, Molodensky-Badekas model, and Veis model. Also, we adopted multiple regression equation method to convert from Tokyo datum to KTRF. We used 935 control points as a common points and applied gross error analysis for detecting the outlier among those control points. The coordinate transformation was carried out using similarity transformation applied the obtained seven parameters and the precision of transformed coordinate was evaluated about 9,917 third or forth order control points. From these results, it was found that Bursa-Wolf model and Molodensky-Badekas model are more suitable than other for the determination of transformation parameters in Korea. And, transforming accuracy using MRE is lower than other similarity transformation model.

A Solar Energy Harvesting Circuit with Low-Cost MPPT Control for Low Duty-Cycled Sensor Nodes. (낮은 듀티 동작의 센서 노드를 위한 저비용 MPPT 제어기능을 갖는 빛에너지 하베스팅 회로)

  • Yoon, Eun-Jung;Yang, Min-Jae;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.397-400
    • /
    • 2015
  • In this paper a solar energy harvesting system with low-cost MPPT control for low duty-cycled sensor nodes is proposed. The targeted applications are environment, structure monitoring sensor nodes that are not required successively to operate, and MPPT(Maximum Power point Tracking) control using simple circuits is low-cost differently than existing MPPT control. The proposed MPPT control is implemented using linear relationship between the open-circuit voltage of a solar cell. The designed MPPT circuit traces the maximum power point by sampling periodically the open circuit voltage of the solar cell and delivers the maximum available power to the load. The proposed circuit is designed in 0.35um CMOS process. The designed chip area is $975um{\times}1025um$ including pads. Measured results show that the designed system can track the MPP voltage by sampling periodically the open circuit voltage of solar cell.

  • PDF