• 제목/요약/키워드: Nano-adhesion

검색결과 338건 처리시간 0.034초

SPM을 이용한 Si 표면위에 플라즈마 처리된 소수성 박막의 나노 트라이볼로지적 특성 연구 (Nanotribological Characteristics of Plasma Treated Hydrophobic Thin Films on Silicon Surfaces using SPM)

  • 윤의성;양승호;공호성;고석근
    • Tribology and Lubricants
    • /
    • 제19권2호
    • /
    • pp.109-115
    • /
    • 2003
  • Nanotribological characteristics between a Si$_3$N$_4$ AFM tip and hydrophobic thin films were experimentally studied. Tests were performed to measure the nano adhesion and friction in both AFM (atomic force microscope) and LFM (lateral force microscope) modes in various .ranges of normal load. Plasma-modified thin polymeric films were deposited on Si-wafer (100). Results showed that wetting angle of plasma-modified thin polymeric film increased with the treating time, which resulted in the hydrophobic surface and the decrease of adhesion and friction. Nanotribological characteristics of these surfaces were compared with those of other hydrophobic surfaces, such as DLC, OTS and IBAD-Ag coated surfaces. Those of OTS coated surface were superior to those of others, though wetting angle of plasma-modified thin polymeric film is higher.

나노 다이아몬드 코팅박막의 기계적 특성 평가를 위한 계측시스템의 개발 (Development of the Measurement System for Evaluating Mechanical Properties of Nano-diamond Coated Film)

  • 권현규;이소진;권용민
    • 반도체디스플레이기술학회지
    • /
    • 제18권1호
    • /
    • pp.25-31
    • /
    • 2019
  • In this study, a new adhesion evaluating equipment and data processing methods were developed to overcome some limitations of existing evaluating equipment. Nano-diamond coated tool is a specimen of experiment. When applying frictional force and shear force on the specimen by a rotating polishing pad, delamination occurs at a moment. During each experiment, the vibration, load, and torque is obtained by accelerometer, loadcell and torque s+ kpensor. Frictional force and coefficient of friction are obtained by calculating torque and load. Based on FFT transformation, acceleration is processed and analyzed. As a result, the moment of delamination and the load at that time can be detected by the new developed equipment and measurement system. Finally, we call this load as an Adhesion force.

나노스케일 표면돌기 간의 미세접촉에 대한 해석 (Analysis of Nano-contact Between Nano-asperities Using Atomic Force Microscopy)

  • 안효석;장동영
    • 한국생산제조학회지
    • /
    • 제18권4호
    • /
    • pp.369-374
    • /
    • 2009
  • In micro/nano-scale contacts in MEMS and NEMS, capillary and van der Waals forces generated around contacting micro-asperities significantly influence the performance of concerning device as they are closely related to adhesion and stiction of interacting surfaces. In this regard, it is of prime importance to accurately estimate the magnitude of surface forces so that an optimal solution for reducing friction and adhesion of micro/nano-surfaces may be obtained We introduced an effective method to calculate these surface forces based on topography information obtained from an atomic force microscope. This method was used to calculate surface forces generated in the contact interface formed between diamond-like carbon coating and $Si_3N_4$ ball. This method is shown to effectively demonstrate the influence of capillary force in the contact area, especially in humid atmosphere.

  • PDF

세륨옥사이드나노입자(Cerium oxide nano particles: CNPs)를 함유한 치면열구전색재의 Streptococcus mutans 부착량 변화 (Changes in the amount of adhesion of Streptococcus mutans to pit and fissure sealant incorporating cerium oxide nano particles(CNPs))

  • 이성숙;박영민;김동애
    • 한국치위생학회지
    • /
    • 제20권4호
    • /
    • pp.535-543
    • /
    • 2020
  • Objectives: The aim of this study was to investigated the surface roughness and change in the amount of adhesion of Streptococcus mutans to the commercial pit and fissure sealant containing cerium oxide nano particles(CNPs). Methods: The CNPs was incorporated into a commercial pit and fissure sealant at 0-4.0 wt%. Disk Specimens (ϕ 10 mm × 2 mm) were prepared by light polymerization the front and back for 40s. Average surface roughness was measured and Streptococcus mutans adhesion was observed under confocal laser scanning microscopy (CLSM) after 24 hour. Data were statistically analyzed by one-way ANOVA and Tukey HSDa post-hoc test. Results: Difference of the surface roughness(Ra) between groups was not statistically significant in both non CNPs group and CNPs group(p>0.05). In CNPs group, the amount of S. mutans adhesion was significantly different between control group and decreased in order of CNPs 4.0, CNPs 0.5, CNPs 1.0 and CNPs 2.0(p<0.05). Conclusions: Within the limitation of this study, these aspects of oral bacteria performances suggest potential usefulness of the CNPs incorporation, especially CNPs 1% and 2%, in pit and fissure sealant for inducing antibacterial effect.

불소수지의 무전해 동도금을 위한 단계적 플라즈마 전처리법에 관한 연구 (Study on Two Step Plasma Treatment for Electroless Cu Plating of Fluoropolymer)

  • 신승한;한성호;김영석
    • 한국표면공학회지
    • /
    • 제38권3호
    • /
    • pp.118-125
    • /
    • 2005
  • Low temperature plasma treatment with different gases and rf powers were performed to improve the adhesion strength between polytetrafluoroethylene(PTFE) and electroless deposited copper. According to the research, $H_2$ plasma having hydrogen radical was more effective in surface polarity modification than $O_2$ plasma due to the defluorination reaction. However, surface roughness of PTFE was more increased with $O_2$ than $H_2$ plasma. PTFE treated with $120W-O_2$ plasma and $250w-H_2$ plasma, consecutively showed rougher surface than single step $250w-H_2$ plasma treated one and more hydrophilic than single step $120W-O_2$ plasma treated one. And it showed 5B tape test grade, which is better adhesion property than 1B or 3B obtained by single step plasma treatment. In addition, adhesion strength between PTFE and Cu deposit is also deeply affected by residual water on its interface.

Fabrication of field emitters using a filtration-taping-transfer method

  • Song, Ye-Nan;Shin, Dong-Hoon;Sun, Yuning;Shin, Ji-Hong;Lee, Cheol-Jin
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.466-466
    • /
    • 2011
  • There have been several methods to fabricate carbon nanotube (CNT) emitters, which include as-grown, spraying, screen-printing, electrophoresis and bonding methods. Unfortunately, these techniques generally suffer from two main problems. One is a weak mechanical adhesion between CNTs and the cathode. The as-grown, spraying and electrophoresis methods show a weak mechanical adhesion between CNTs and the cathodes, which induces CNT emitters pulled out under a high electric field. The other is a severe degradation of the CNT tip due to organic binders used in the fabrication process. The screen-printing method which is widely used to fabricate CNT emitters generally shows a critical degradation of CNT emitters caused by the organic binder. Such kinds of problems induce a short lifetime of the CNT field emitters which may limit their practical applications. Therefore, a robust CNT emitter which has the strong mechanical adhesion and no degradation is still a great challenge. Here, we introduce a simple and effective technique for fabrication of CNT field emitter, namely filtration-taping-transfer method. The CNT emitters fabricated by the filtration-taping-transfer method show the low turn-on electric fields, the high emission current, good uniformity and good stability. The enhanced emission performance of the CNT emitters is mainly attributed to high emission sites on the emitter area, and to good ohmic contact and strong mechanical adhesion between the emitters and cathodes. The CNT emitters using a simple and effective fabrication method can be applied for various field emission applications such as field emission displays, lamps, e-beam sources, and x-ray sources. The detail fabrication process will be covered at the poster.

  • PDF

Molecular Dynamics Simulation of Adhesion Processes

  • Cho, Sung-San;Park, Seungho
    • Journal of Mechanical Science and Technology
    • /
    • 제16권11호
    • /
    • pp.1440-1447
    • /
    • 2002
  • Adhesion of a hemispherical tip to the flat surface in nano-structures is simulated using the molecular dynamics technique. The tip and plates are modeled with the Lennard-Jones molecules. The simulation focuses on the deformation of the tip. Detailed descriptions on the evolution of interaction force, the energy dissipation due to adhesion hysteresis, the forma- tion-growth-breakage of adhesive junction as well as the evolution of molecular distribution during the process are presented. The effects of the tip size, the maximum tip approach, the tip temperature, and the affinity between the tip and the mating plate are also discussed.

FDTS와 OTS SAM의 어닐링 온도에 따른 트라이볼로지 특성 (Tribological Characteristics of FDTS & OTS SAM according to Annealing Temperature)

  • 양지철;김대은
    • 한국정밀공학회지
    • /
    • 제20권1호
    • /
    • pp.240-247
    • /
    • 2003
  • The tribological characteristics of FDTS (1H, 1H, 2H, 2H-Perflurodecyltrichlorosilane) SAM (self-assembled monolayer) and OTS (octadecyltrichlorosilane) SAM treated by high temperature annealing have been investigated from the viewpoint of stiction, adhesion and friction in micro/nano scale. From the experimental results, it was found that OTS SAM gets destroyed at 20$0^{\circ}C$ and stiction, adhesion and friction coefficient increased, but FDTS SAM was stable up to 40$0^{\circ}C$. Also, it was found that the friction coefficient of normal OTS SAM below 20$0^{\circ}C$ is lower than that of FDTS SAM in micro/nano scale, but stiction and adhesion is vice versa. This work shows the importance of surface group of self-assembled monolayer in dictating the tribological characteristics and thermal stability.

접촉 역학적 접근에 의한 점탄성/탄성, 점탄성/점탄성 재료간의 접합 에너지 측정 (A Measurement of Adhesion Energy between Viscoelastic/Elastic, Viscoelastic/Viscoelastic Materials Using Contact Mechanics Approach)

  • 이찬;엄윤용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1030-1035
    • /
    • 2003
  • The nanoimprint lithography technology makes higher density of semiconductor device and larger capacity of storage media. In this technology the induced damage while detaching polymer pattern from mold should be minimized. In order to analyze the problem, the basic knowledge of adhesion between the polymer and the mold is required. In this study a contact experiment of polyisobutylene specimen with spherical steel tip and polyisobutylene bead tip was conducted using nano indenter. During the contact experiment with various loading rate under load control the contact behavior of viscoelastic material was measured, i.e., the load and displacement between the tip and the specimen were measured. The data was analyzed by HBK model to obtain the stress intensity factor of contact edge and the contact radius as a function of time. Also the adhesion energies between steel/polyisobutylene and polyisobutylene/polyisobutylene were obtained employing the analysis of the crack of viscoelastic material by Schapery.

  • PDF

Sub-micrometer 크기의 패턴의 복제시 발생되는 이형 특성의 분석 (Analysis of anti-adhesion property in replication of patterns of sub-micrometers)

  • 이남석;강신일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.940-944
    • /
    • 2003
  • With the increasing demand for plastic micro components, micro-/nano-molding using the mother stamper has received much attention. If the replication temperature is too high, the adhesion between the stamper and the polymer melt may deteriorate the surface quality of the replicated part, excessively wearing down the stamper. In this paper, an experimental method analyzes the temperature dependency of the anti-adhesion property between the actual stamper with patterns of sub-micrometer and the polymer melt. As a practical example, a correlation between the contact angle of the stamper and the surface quality of the molded substrates as a function of the replication temperature, respectively, was obtained quantitatively.

  • PDF