• 제목/요약/키워드: Nakdong-river

검색결과 1,837건 처리시간 0.028초

초음파 처리 조건에 따른 집락형 유해남조류 Microcystis 세포수 변화 연구 (Colonial Cyanobacteria, Microcystis Cell Density Variations using Ultrasonic Treatment)

  • 이혜진;박혜경;허준;이현제;홍동균
    • 한국물환경학회지
    • /
    • 제34권2호
    • /
    • pp.210-215
    • /
    • 2018
  • It is difficult to count colonial cyanobacteria Microcystis cells since the thickness of colonies is constrained by amorphous mucilage, making it impossible to estimate the number of cells. Disaggregation of Microcystis colonies into single cell is needed to improve the accuracy and precision of cell density estimation of naturally collected samples. Uultrasonic treatment method is commonly used owing to the simplicity and immediacy of the procedure. However, amplitude, frequency, and duration of ultrasonic treatment also cause cell loss during the experiment. Optimal ultrasonic treatment has not been standardized yet. Therefore, the objective of this study was to investigate optimal ultrasonic treatment by analyzing cell density and colony numbers. We collected colonial Microcystis from Changnyeong-Haman weir area in Nakdong River during harmful algal boom period from September to October in 2017. Ultrasonic treatment method was applied to disrupt colonies into single cells to enumerate cell density. Among treatment conditions, results from continuously treated for 100 seconds were found to be the optimum to reduce colonies to a suspension of single cell without cell losses under high and low density of Microcystis cells. Lugol iodine fixed cells followed by sonication showed less negative impact of cell damage within the optimal treatment time (100 seconds). Furthermore, disaggregated cells treated by sonication enables microscopic observation more easily since gas vacuoles were collapsed to facilitate sedimentation of cells under the counting chamber for quantitative enumeration of buoyant Microcystis cells.

김해시 물 순환 개선 도시계획에 의한 비점오염물질 저감효과 분석 (Analysis of Non-Point Source Pollution Reduction using Water Sensitive Urban Design in Gimhae, South Korea)

  • 정강영;김신;권헌각;양득석;김교식;장광진;신동석;안정민
    • 한국환경과학회지
    • /
    • 제25권11호
    • /
    • pp.1499-1509
    • /
    • 2016
  • This study was performed to analyze the effects of a water circulation green area plan on non-point source pollution in Gimhae South Korea. A quantitative analysis of Arc-GIS data was conducted by applying a watershed model based on Fortran to investigate the changes to direct runoff and pollution load. Results showed that prior to the implementation of the water circulation green area plan in Gimhae, direct runoff was $444.05m^3/year$, total biological oxygen demand (BOD) pollution load was 21,696 kg/year, and total phosphorus (TP) pollution load was 1,743 kg/year. Implementation of the development plan was found to reduce direct runoff by 2.27%, BOD pollution load by 1.16% and TP pollution load by 0.19% annually. The reduction in direct runoff and non-point source pollution were attributed to improvements in the design of impermeable layers within the city.

MBOD법에 의한 낙동강의 조류증식 제한인자 추정 (Evaluation of Algal Growth Limiting Factor in the Nakdong River by MBOD Method)

  • 송교욱;서인숙
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.469-479
    • /
    • 1995
  • The increase of population and industrial activities had brought into eutrophication in the Nakdong river. A remarkable acceleration of eutrophication brought about serious problems for water supply. Therefore, for the purpose of conservation of water quality in the Nakdong river it is necessary to control nutrients. MBOD method was use to evaluate algal growth limiting factor and algal growth potential in the Nakdong river from June to August 1994. The modified biochemical oxygen demand(MBOD) depends on the amount of available inorganic nutrient and organic substrate during 5 day incubation in the dark at 2$0^{\circ}C$. The MBOD assay depends on inorganic nutrients such as P and N as well as reduced carbon and called the MBOD, the MBOD-P, and the MBOD-N, respectively. The results of bioassay by MBOD(Modified BOD) method showed that the MBOD, MBOD-P and MBOD-N value were found to be in the ranges of 3.8~96.0 mg$O_2$/l, 5.6~94.0 mg$O_2$/l and 42.0~220 mg$O_2$/l, respectively. And the the bioassay value was found to be the highest in Koryong area and the lowest in Waekwan area throughout the Nakdong river. The variations of MBOD-P and MBOD-N value showed similar tendencies to the variations of phosphorus and nitrogen value, respectively. By MBOD method, the relationships of MBOD, MBOD-P and MBOD-N value were MBOD ≒ MBOD-P 《 MBOD-N. The MBOD value was nearly equal to the MBOD-P value, and the MBOD-N value was 3 to 20 times more than the MBOD-P value, approximately. Therefore, in the Nakdong river, phosphorus was the limiting factor for algal growth during summer season. The algal growth potential as the concentration of chlorophyll-a in the summer was maximum 5 times more than standing crop as it.

  • PDF

낙동강 수계에서의 Nitrosamines 검출 현황 (Occurrence of Nitrosamines in Nakdong River Basin)

  • 김경아;손희종;이상원;류동춘;권기원
    • 대한환경공학회지
    • /
    • 제36권1호
    • /
    • pp.49-57
    • /
    • 2014
  • 본 연구에서는 낙동강에서의 nitrosamine류의 검출 현황에 대해 조사하였다. 본 연구결과에 따르면 6종의 nitrosamine류 (NDEA (N-nitrosodiethylamine), NDPA (N-Nitrosodi-n-propylamine), NDMA (N-nitrosodimethylamine), NMEA (N-nitrosomethylethylamine), NDBA (N-nitrosodi-n-butylamine) 및 NDPHA (N-Nitrosodiphenylamine))가 낙동강에서 검출되었다. 검출된 nitrosamine류 6종 중에서 NDEA와 NDPA가 주요 오염물질로 나타났으며, 몇몇 지점들에서의 NDEA의 검출농도는 미국 CDHCS (California Department of Health Care Services)의 대응수준인 100 ng/L를 초과하였으며, NDPA의 경우는 소수의 지점들에서 CDHCS의 대응수준(500 ng/L)에 근접한 농도로 검출되었다. 낙동강에서 검출된 nitrosamine류 9종의 최대 검출농도는 735.7 ng/L로 나타났다.

서낙동강에서 생활환경기준을 적용한 수질등급 및 수질지수의 시·공간 변동 분석 (Temporal-Spatial Variations of Water Quality Level and Water Quality Index on the Living Environmental Standards in the West Nakdong River)

  • 박경덕;강동환;소윤환;김일규
    • 한국환경과학회지
    • /
    • 제28권12호
    • /
    • pp.1071-1083
    • /
    • 2019
  • In this study, water quality levels were classified and water quality indices were calculated and analysed by using the water quality components of living environmental standards monitored 10 years (2008 ~ 2017) at four stations in the West Nakdong River. As a result of analyzing the monthly variation of the water quality components of the living environmental standards, the water quality in the West Nakdong River was worse downstream than upstream, and pollution at the WNR3 located in the downstream of the Jomangang was the most serious. As a result of classification of water quality levels, BOD and COD levels were the lowest, so water quality pollution in the West Nakdong River was found to be highly influenced by organic matters. The water quality index was the lowest in July and August at four stations, so water quality is showing the worst in summer. As a result of analyzing the correlation between the water quality components and the water quality index, the correlation between the TOC and the water quality index was high in the four stations, and the water quality index in the West Nakdong River was dominated by organic matters and nutrients.

MOVE.2 확장기법 적용을 통한 장기 부하지속곡선 구축 및 유황조건별 수체손상평가 (Construction of Long-term Load Duration Curve Using MOVE.2 Extension Method and Assessment of Impaired Waterbody by Flow Conditions)

  • 김경훈;권헌각;임태효;이규동;신동석;나승민
    • 한국물환경학회지
    • /
    • 제33권1호
    • /
    • pp.51-62
    • /
    • 2017
  • The purpose of this study is to evaluate on the applicability of Load Duration Curve (LDC) method using Maintenance of Variance Extension types 2 method and sampling data for efficient total maximum daily loads at the Nakbon-A unit watershed in Korea. The LDC method allows for characterizing water quality data such as BOD, TOC, T-N and T-P in this study at different flow regimes(or quarters). BOD usually exceeded the standard value (exceedance probability 50%) at low flow zone. On the other hand, TOC, T-N, T-P usually exceeded the standard value at dry and low flow zone. Seasonally all water quality variables usually exceeded the standard value at Q1(Jan-Mar) and Q2(Apr-Jun) zones. Improvement of effluent control from wastewater treatment plants are effective to improve BOD and T-P.

수문개폐에 따른 낙동강 하구둑 하류부의 해양물리환경변화 (Variations of Physical Oceanographic Environment Caused by Opening and Closing the Floodgate in Nakdong Estuary)

  • 김기철;양한섭;김차겸;문창호;장성태
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제2권2호
    • /
    • pp.49-59
    • /
    • 1999
  • 낙동강 하구역은 담수와 해수가 만나 복잡한 순환양상을 보이는 지역이다 낙동강 하구역은 하구둑의 건설로 혼합체계와 순환양상이 많이 변하였다. 논 연구에서는 낙동강 하구둑 하류부의 해양 물리 환경 변화론 하구둑의 수문개폐에 초점을 맞춰 분석하였다. 관측과 분석에는 3가지의 경우로 나누었다. 1. 평상시 (조시에 따라 수문 개폐) 2. 홍수시 (수문 완전 개방) 3. 갈수시(수문이 완전히 닫혔을시).

  • PDF

낙동강 지류·지천의 유량·수질 특성 및 하천관리를 위한 등급화 방안 연구 (Flow Rate·Water Quality Characteristics of Tributaries and a Grouping Method for Tributary Management in Nakdong River)

  • 나승민;임태효;이재운;권헌각;천세억
    • 한국습지학회지
    • /
    • 제17권4호
    • /
    • pp.380-390
    • /
    • 2015
  • 본 연구에서는 낙동강 수계에 속한 지류 지천의 효율적인 유역선정 및 수질 개선방안을 모색하기 위해 38개 지류 지천을 대상으로 수질 및 유량 모니터링을 실시하였다. 2013~2014년 동안 실시한 수질 유량자료를 바탕으로, 수질현황 결과와 각 항목 사이 상관관계를 분석하였다. 더불어, 상관계수가 높고 총량 목표수질지표 항목인 생물화학적산소요구량($BOD_5$), 총인(TP) 지표를 이용하여 $BOD_5$농도/유량(Q), TP농도/유량 교차기준으로 지류 지천 등급화 방안을 실시하였다. 그 결과, $BOD_5$, $COD_{Mn}$, TP, TOC 등의 유기오염물질농도는 낙동왜관 및 낙동고령 중권역에 위치한 구미천, 경호천, 진전천, 기세곡천, 용하천, 용호천 등에서 하천환경기준 III 및 IV 등급 (5~8 mg/L 이하) 수준으로 높게 관찰되었다. Pearson 상관계수를 통한 수질항목 (12가지)간 상관관계 조사 결과 역시, $BOD_5$, $COD_{Mn}$, TP, TOC 등의 상관관계지수가 다른 수질항목들에 비하여 0.8 (p<0.01) 이상으로 높았다. 유량과 수질 ($BOD_5$, TP)항목을 활용하여 하천등급화를 실시한 결과, 유량 ($0.1m^3/s$ 이상)과 유기물 농도가 높은 ($BOD_5$ > 3.0 mg/L, TP > 0.1 mg/L) I 그룹의 하천(영산천, 구미천, 기세곡천, 용하천, 용호천, 미전천)이 우선수질개선 및 중점 관리가 필요한 것으로 나타났다.

낙동강 중류부의 자정능력에 대한 연구 -용존산소를 중심으로- (Study on Natural Purification in the Midstream of Nakdong River)

  • 이홍근;한진석
    • 물과 미래
    • /
    • 제17권2호
    • /
    • pp.85-97
    • /
    • 1984
  • Measuring the river flow and water quality in the midstream of the Nakdong River, the natural purification status in examined through the analyses of the elements which affect the variation of dissolved oxygen, and DO model is evaluated to the midstream reach of the river. The major results of this study are as follows; the pruification factor of the of the river is relatively high, it is worried over eutrophication considering much production of algae, and it is evaluated that important factor affecting the DO value computed by the proposed DO model are in order of reaeration coefficient, carbonaceous BOD and deoxygenation constant.

  • PDF

CN의 변화에 따른 안동시 물순환 선도도시 조성계획의 비점오염부하 저감효과 분석 (Analysis of Nonpoint source Reduction at Andong Area Considering Changes in CN)

  • 권헌각;정강영;김신;신석호;안정민;김경훈
    • 한국습지학회지
    • /
    • 제18권4호
    • /
    • pp.342-349
    • /
    • 2016
  • 낙동강수계에 속하는 안동시는 안동댐, 임하댐을 포함하여 낙동강이 흐르는 도시로 경상북도 신 도청 이전과, 지속적 도시화로 인해 불투수 면적이 증가하고 있어 강우 시 유출량 증가 및 비점오염원 부하가 증가되고 있는 지역이다. 본 연구에서는 물순환 선도도시에 선정된 도시 중 안동시를 대상으로 개발에 따른 유출량과 비점오염부하량을 비교 평가하였다. 안동시 물순환 선도도시 계획(안)에 대해 시 공간적 변화를 고려한 CN값을 이용한 직접 유출량과 BOD, T-N 및 T-P 비점오염부하량을 평가한 결과, 옥상녹화 및 투수포장 교체, 물순환 공원 및 거리 조성, 도심지 불투수층 개선 사업 등 4가지 scenario 모두 적용되어 개발될 경우 연간 직접유출이 10.41%, BOD 비점오염부하량이 20.56%, T-N 9.55% 및 T-P 비점오염부하량이 14.29% 저감되는 것으로 조사되었다. 4가지의 개발 scenario 중 저감률이 가장 높은 것은 도시지역 불투수면 개선 사업으로 조사되었으며 개발 이전 대비 연간 직접유출이 6.25%, BOD 비점오염부하량이 11.84%, T-N 비점오염부하량이 4.46% 및 T-P 비점오염부하량이 10.20% 저감되는 것으로 조사되었다.