• Title/Summary/Keyword: Nai\

Search Result 181, Processing Time 0.023 seconds

Performance Improvement of MMO Gameservers Using RIO and HTM (RIO와 HTM을 이용한 MMO 게임서버의 성능 개선)

  • Kang, Subin;Jung, NaiHoon
    • Journal of Korea Game Society
    • /
    • v.20 no.6
    • /
    • pp.13-22
    • /
    • 2020
  • RIO is a new network API for Windows that is designed to have high I/O performance through low overhead and latency. Using RIO, MMO game servers may have much performance benefits. In addition, HTM has better productivity and performance compared to existing synchronization methods, so adopting it may produce better performance, also. In this paper, we improved server performance by implementing a new MMO game server architecture optimized with RIO and HTM. The performance of the server was verified through a benchmark program, and the number of concurrent users increased by 19%.

A study on CFRP based lightweight House deck structure design and configuration of Deck body connected IoT sensor data acquisition devices

  • Jaesang Cha;Chang-Jun Ahn;Quoc Cuong Nguyen;Yunsik Lim;Hyejeong Cho;Seung Youn Yang;Juphil Cho
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.4
    • /
    • pp.250-260
    • /
    • 2023
  • In this paper, we designed a IoT(Internet of Things) sensor block embedded lightweight house deck structures that can be implemented using Carbon Fiber Reinforced Polymer(CFRP). Deck-Sensor interconnection interface block via IoT connectivity Hub that can mount external environmental sensors such as fire sensors on the Deck body itself was also proposed. Additionally we described the configuration of devices for data acquisition and analysis based on IoT environmental detection sensors that can be commonly installed and used on these deck bodies. On the other hand, received sensing data based monitoring user interface(UI) also developed and used for sensing data analysis for remote monitoring center. Through the implementation of such IoT-based sensor data transmission and collection analysis devices and UI software, this paper confirmed the availability of CFRP based lightweight House deck structure and possibility of CFRP deck-based IoT sensor data networking and analysis functions.

Diagnostic Accuracy of Lactate Dehydrogenase/Adenosine Deaminase Ratio in Differentiating Tuberculous and Parapneumonic Effusions: A Systematic Review

  • Larry Ellee Nyanti;Muhammad Aklil Abd Rahim;Nai-Chien Huan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.1
    • /
    • pp.91-99
    • /
    • 2024
  • Background: Tuberculous pleural effusion (TPE) and parapneumonic effusion (PPE) are often difficult to differentiate owing to the overlapping clinical features. Observational studies demonstrate that the ratio of lactate dehydrogenase to adenosine deaminase (LDH/ADA) is lower in TPE compared to PPE, but integrated analysis is warranted. Methods: We conducted a systematic review to evaluate the diagnostic accuracy of the LDH/ADA ratio in differentiating TPE and PPE. We explored the PubMed and Scopus databases for studies evaluating the LDH/ADA ratio in differentiating TPE and PPE. Results: From a yield of 110 studies, five were included for systematic review. The cutoff value for the LDH/ADA ratio in TPE ranged from <14.2 to <25. The studies demonstrated high heterogeneity, precluding meta-analysis. Quality Assessment of Diagnostic Accuracy Studies Tool 2 assessment revealed a high risk of bias in terms of patient selection and index test. Conclusion: LDH/ADA ratio is a potentially useful parameter to differentiate between TPE and PPE. Based on the limited data, we recommend an LDH/ADA ratio cutoff value of <15 in differentiating TPE and PPE. However, more rigorous studies are needed to further validate this recommendation.

Is Level V Dissection Necessary for Low-risk Patients with Papillary Thyroid Cancer Metastasis in Lateral Neck Levels II, III, and IV

  • Yu, Wen-Bin;Tao, Song-Yun;Zhang, Nai-Song
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4619-4622
    • /
    • 2012
  • Whether it is beneficial to dissect level V in papillary thyroid cancer (PTC) patients with positive lateral neck lymph nodes at levels II-IV is still controversial, especially for low risk cases. In this study, we reviewed the medical records of 47 patients who underwent 47 ipsilateral selective lateral neck dissections (levels II-IV) for previously untreated papillary thyroid carcinomas between October 2006 and October 2008 to assist in establishing the optimal strategy for lateral neck dissection in low risk PTC patients with clinically negative level V nodes. All 47 patients were confirmed to have positive lymph nodes pathologically. Seventeen (36.12%), 36 (76.6%), and 34 (72.34%) patients had positive lymph nodes in levels II, III, and IV, respectively. The mean number of pathologically positive lymph nodes was 1.7 in level II, 2.9 in level III, 2.8 in level IV. No death and distant metastasis were recorded during follow up period. Just 2 patients exhibited recurrence to lymph nodes, and only one showed nodal recurrence in ipsilateral level V, who had positive lymph nodes in all of levels II, III, and IV at initial neck surgery. In conclusion, for PTC low risk patients with clinically negative lymph nodes in level V, non-performance of level V dissection would still achieve good survival results as traditional modified radical neck dissection, with a "wait and see" strategy to be recommended.

Aberrant Epigenetic Alteration in Eca9706 Cells Modulated by Nanoliposomal Quercetin Combined with Butyrate Mediated via Epigenetic-NF-κB Signaling

  • Zheng, Nai-Gang;Wang, Jun-Ling;Yang, Sheng-Li;Wu, Jing-Lan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4539-4543
    • /
    • 2014
  • Since the epigenetic alteration in tumor cells can be reversed by the dietary polyphenol quercetin (Q) or butyrate (B) with chemopreventive activity, suggesting that Q or B can be used for chemopreventive as well as therapeutic agent against tumors. In this study the polyphenol flavonoid quercetin (Q) or sodium butyrate (B) suppressed human esophageal 9706 cancer cell growth in dose dependent manner, and Q combined with B (Q+B) could further inhibit Eca9706 cell proliferation than that induced by Q or B alone, compared with untreated control group (C) in MTT assay. The reverse expressions of global DNMT1, $NF-{\kappa}Bp65$, HDAC1 and Cyclin D1 were down-regulated, while expressions of caspase-3 and $p16INK4{\alpha}$ were up-regulated, compared with the C group in immunoblotting; the down-regulated HDAC1-IR (-immunoreactivity) with nuclear translocation, and up-regulated E-cadherin-IR demonstrated in immunocytochemistry treated by Q or B, and Q+B also displayed further negatively and positively modulated effects compared with C group. The order of methylation specific (MS) PCR of $p16INK4{\alpha}$: C>B/Q>Q+B group, while the order of E-cadherin expression level was contrary, Q+B>Q/B>C group. Thus, Q/B, especially Q+B display reverse effect targeting both altered DNA methylation and histone acetylation, acting as histone deacetylase inhibitor mediated via epigenetic-$NF-{\kappa}B$ cascade signaling.

Analysis of ICU Treatment on Resection of Giant Tumors in the Mediastinum of the Thoracic Cavity

  • Kang, Nai-Min;Xiao, Ning;Sun, Xiao-Jun;Han, Yi;Luo, Bao-Jian;Liu, Zhi-Dong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3843-3846
    • /
    • 2013
  • Objective: The purpose of this study was to assess prognosis after resection of giant tumors (including lobectomy or pneumonectomy) in the mediastinum. Materials and Methods: Patients with resection of a giant tumor in the mediastinum of the thoracic cavity received ICU treatment including dynamic monitoring of vital signs, arterial blood pressure and CVP detection, determination of hemorrhage, pulmonary function and blood gas assay, treatment of relevant complications, examination and treatment with fiber optic bronchoscopy, transfusion and hemostasis as well as postoperative removal of ventilators by invasive and non-invasive sequential mechanical ventilation technologies. Results: Six patients were rehabilitated successfully after ICU treatment with controlled postoperative errhysis and pulmonary infection by examination and treatment with fiber optic bronchoscopy without second application of ventilators and tubes after sequential mechanical ventilation technology. One patient died from multiple organ failure under ICU treatment due to postoperative active hemorrhage after second operative hemostasis. Conclusions: During peri-operative period of resection of giant tumor (including lobectomy or pneumonectomy) in mediastinum ofthe thoracic cavity, the ICU plays an important role in dynamic monitoring of vital signs, treatment of postoperative stress state, postoperative hemostasis and successful removal of ventilators after sequential mechanical ventilation.

Design of QPSK Ultrasonic Transceiver For Underwater Communication (수중 통신을 위한 QPSK 초음파 송수신기의 설계)

  • Cho Nai-Hyun;Kim Duk-Yung;Kim Yong-Deuk;Chung Yun-Mo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.51-59
    • /
    • 2006
  • In this paper, we propose an excellent ultrasonic transceiver system based on a QPSK modulation technique for underwater communication. The transmitter sends a still image at the level of 187dB re $1{\mu}Pa/V@1m$ through a power amplifier by driving an ultrasonic sensor. The receiver performs digital conversion at the 100kHz sampling frequency, demodulation and decoding process for the image sent from the transmitter through the underwater communication. We have shown that the processed image at the receiver is almost the same as the orignal one. The maximum detection distance of the system proposed in this paper is approximately 1.17km. To cope with the difficulties of transmission loss, this paper proposes, implements and analyzes important parameters of sensors and circuits used in the system. Most of the underwater communication has focused on the transmission of audio signal, but this paper suggests an efficient underwater communication system for still image transmission.

Risk Factors for Health and Environmental Disease in Gyeongju, Pohang, and Ulsan (경주, 포항, 울산지역 보건.환경성 질환 위해 인자)

  • Jung, Jong-Hyeon;Choi, Bong-Wook;Moon, Ki-Nai;Seok, Seong-Ja;Kim, Hyun-Gyu;Shon, Byung-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.2
    • /
    • pp.82-94
    • /
    • 2010
  • This study was undertaken in an attempt to provide scientific grounds in explaining the causes of environmental and respiratory diseases resulting from air pollutants in Gyeongju and its neighboring areas. In relation to heavy metals, lead (Pb) was $0.0135{\sim}0.1744\;{\mu}g/m^3$ and high in order of Pohang, Ulsan, and Gyeongju while nickel (Ni) was $0.0023{\sim}0.0115\;{\mu}g/m^3$. The concentrations of heavy metals in the investigated areas did not exceed the environmental standards or Guideline Value of Korea or other countries. However, it is considered necessary to apply intensive control to some heavy metals including cadmium (Cd) that show a relatively high level of hazard. Based on the responses to the survey, measured personal interest in environmental pollution and the basic knowledge of the causes of the respiratory diseases was higher in those with a family history of allergic reactions to metals and bronchial asthma. The incidence of allergic disease was higher in those who are currently in poor health state. In addition, the general knowledge of environmental pollutants was higher in those with higher educational level and those with a higher interest in environmental pollution. Personal interest in environmental pollution was higher in those with higher basic knowledge of environmental pollutants. Therefore, it is necessary to increase the awareness through better education and campaigns on environmental pollution.

The Removal of Trembling Artifacts for FORMOSAT-2

  • Chang Li-Hsueh;Wu Shun-Chi;Cheng Hsin-Huei;Chen Nai-Yu
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.142-145
    • /
    • 2005
  • Since the successful launch of FORMOSAT -2 satellite by National Space Organization of Taiwan in May 2004, the Remote Sensing Instrument (RSI) on- board the FORMOSAT -2 has continuously acquired images at one panchromatic and four multi-spectral bands (http://www.nspo.org.tw). In general, the RSI performs well and receives high quality images which proved to be very useful for various applications. However, some RSI panchromatic products exhibit obvious trembling artifact that must be removed. Preliminary study reveals that the trembling artifact is caused by the instability of the spacecraft attitude. Though the magnitude of this artifact is actually less than half of a pixel, it affects the applicability of panchromatic products. A procedure removing this artifact is therefore needed for providing image products of consistent quality. Due to the nature of trembling artifact, it is impossible to describe the trembling amount by employing an analytic model. Relied only on image itself, an algorithm determining trembling amount and removing accordingly the trembling artifact is proposed. The algorithm consists of 3 stages. First, a cross-correlation based scheme is used to measure the relative shift between adjacent scan lines. Follows, the trembling amount is estimated from the measured value. For this purpose, the Fourier transform is utilized to characterize random shifts in frequency domain. An adaptive estimation method is then applied to deduce the approximate trembling amount. In the subsequent stage, image re-sampling operation is applied to restore the trembling-free product. Experimental results show that by applying the proposed algorithm, the unpleasant trembling artifact is no longer evident.

  • PDF

A Study on Distribution of the Contaminated Sediments in Lake Paldang (팔당호의 오염퇴적물 분포 조사)

  • Oh, Hyeon-Ju;Hong, Jong-Youb;Lee, Sang-Deuk;Chung, Moon-Jo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1295-1305
    • /
    • 2000
  • Status of the contaminated sediments in Lake Paldang was investigated. Sediment samples were taken at 34 points and analyzed in terms of ignition loss, CODer, total P and total N. The contamination level did not show any significant variation with depth of the sediments, which indicated the contaminants were recalcitrant. The type of P in the sediment was analyzed, and the sum of adsorbed P and NAI-P, that can be re-solubilized under the reductive condition, was found to be 20-30% of the total P. From the analysis of the water quality change along with the flowing path, it would be concluded that the effect of the sediments on the water quality is insignificant yet in Lake Paldang. However, long term analysis covering at least four seasons should be continued in order to get a more reliable conclusion. A depth profile map of the sediment in Lake Paldang was provided.

  • PDF