• Title/Summary/Keyword: Nafion-EDTA

Search Result 3, Processing Time 0.016 seconds

Determination of Mercury(II) Using Nafion-EDTA-Modified Glassy Carbon Electrodes (Nafion-EDTA가 수식된 유리탄소전극을 이용한 수은(II)의 측정)

  • 정근호;박찬주;박율희;이지영
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.110-114
    • /
    • 2000
  • Determination of mercury(II) using Nafion-EDTA-modified glassy carbon electrodes is proposed. it is based on the chemical reactivity of an immobilized modifier, Nafion-EDTA. Differential pulse voltammetry is employed, and the oxidation of complexes, at +0.43V vs. Ag/AgCl, is observed. For a 5-min preconcentration period, a linear calibration curve is obtained for mercury(II) concentrations ranging from 1.0$\times$ 10$^{-8}$ to 1.0$\times$10$^{-6}$ M. Further, when an approximate amount of copper(II) is added to the test solution, We demonstrate that at a preconcentration time of 5 min the Nafion-EDTA-modified glassy carbon electrode has a dynamic range of 2 orders of magnitude(from 10$^{-10}$ to 10$^{-8}$ M) and the detection limit is as low as 0.5$\times$ 10$^{-10}$ M(0.01 ppb). This method is applied to the determination of mercury(II) in sea water(4.0$\times$10$^{-10}$ M, 0.08ppb). The result agrees satisfactorily with the value(below 0.1 ppb) measured by using ICP/MS.

  • PDF

Differential Pulse Voltammetry of Lead(II) ton at Nation- EDTA-Glycerol Modified Glassy Carbon Electrodes (Nation-EDTA Glycerol이 수식된 유리탄소전극에서 납(II) 이온의 펄스차이전압전류법)

  • 박상희;박찬주;박은희;고영춘;정근호
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.53-58
    • /
    • 2002
  • A method for the determination of lead(II) ion using a nafion-EDTA(ethylene diamine tetraacetic acid)-glycerol modified glassy carbon electrode was proposed. Lead(II) ion is accumulated at the electrode by complexation and electrostatic attraction with nafion-EDTA-glycerol and detected at -0.560$\pm$0.015V (vs. Ag/AgCl) by differential pulse voltammetry. For the determination of lead(II) ion, a standard calibration curve if obtained from 10$^{-9}$ M lead(II) ion to 10$^{-7}$ M, and the detection limit(3s) is as low as 5.0$\times$10$^{-10}$ M.

Voltammetric Determination of Copper(II) at Chemically Modified Carbon Paste Electrodes Containing Alga

  • Bae, Zun-Ung;Kim, Young-Lark;Chang, Hye-Young
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.611-615
    • /
    • 1995
  • The design of appropriate chemically modified electrodes should allow development of new voltammetric measurement schemes with enhanced selectivity and sensitivity. Microorganism like algae has high ability to trap toxic and heavy metal ions and different affinities for metal ions. A copper(II) ion-selective carbon paste electrode was constructed by incorporating alga Anabaena into a conventional carbon paste mixture, and then the film of 10% Nafion was coated to avoid the swelling of the electrode surface. Copper ion could be deposited at the 25% algamodified electrode for 15 min without the applied potential while stirring the solution by only immersing the electrode in a buffer (pH 4.0) cot1taining copper(II). Temperature was controlled at $35^{\circ}C$. After preconcentration was carried out the electrode was transferred to a 0.1 M potassium chloride solution and was reduced at -0.6 volt at $25^{\circ}C$. The differential pulse anodic stripping voltammetry was employed. A well-defined oxidation peak could be obtained at -0.1 volt (vs SCE). In five deposition / measurement / regeneration cycles, the responses were reproducible and relative standard deviations were 3.3% for $8.0{\times}10^{-4}M$ copper(II). Calibration curve for copper was linear over the range from $2.0{\times}10^{-4}M$ to $1.0{\times}10^{-3}M$. The detection limit was $7.5{\times}10^{-5}M$. Studies of the effect of diverse ions showed that the coexisting metal ions had little or no effect for the determination of copper. But anions such as cyanide. oxalate and EDTA seriously interfered.

  • PDF