• Title/Summary/Keyword: Na wind

Search Result 158, Processing Time 0.019 seconds

Comparison of the Wind Speed from an Atmospheric Pressure Map (Na Wind) and Satellite Scatterometer­observed Wind Speed (NSCAT) over the East (Japan) Sea

  • Park, Kyung-Ae;Kim, Kyung-Ryul;Kim, Kuh;Chung, Jong-Yul;Conillor, Peter-C.
    • Journal of the korean society of oceanography
    • /
    • v.38 no.4
    • /
    • pp.173-184
    • /
    • 2003
  • Major differences between wind speeds from atmospheric pressure maps (Na wind) and near­surface wind speeds derived from satellite scatterometer (NSCAT) observations over the East (Japan) Sea have been examined. The root­mean­square errors of Na wind and NSCAT wind speeds collocated with Japanese Meteorological Agency (JMA) buoy winds are about $3.84\;ms^{-1}\;and\;1.53\;ms^{-1}$, respectively. Time series of NSCAT wind speeds showed a high coherency of 0.92 with the real buoy measurements and contained higher spectral energy at low frequencies (>3 days) than the Na wind. The magnitudes of monthly Na winds are lower than NSCAT winds by up to 45%, particularly in September 1996. The spatial structures between the two are mostly coherent on basin­wide large scales; however, significant differences and energy loss are found on a spatial scale of less than 100 km. This was evidenced by the temporal EOFs (Empirical Orthogonal Functions) of the two wind speed data sets and by their two­dimensional spectra. Since the Na wind was based on the atmospheric pressures on the weather map, it overlooked small­scale features of less than 100 km. The center of the cold­air outbreak through Vladivostok, expressed by the Na wind in January 1997, was shifted towards the North Korean coast when compared with that of the NSCAT wind, whereas NSCAT winds revealed its temporal evolution as well as spatial distribution.

Relationships between Precipitation Component and Surface Wind at Kyungsan, Korea (경산에서의 강수의 화학성분과 지상풍과의 관계)

  • 문영수;박문기
    • Journal of Environmental Science International
    • /
    • v.5 no.2
    • /
    • pp.141-152
    • /
    • 1996
  • This study is an attempt to investigate the chemical components of precipitation and its variation according to surface wind. Precipitation samples were collected by an wet-only precipitation sampler during the period of October 1994 to September 1995 at Kyungsan in Korea. The results obtained in t체s study are summerized as follows. The annual average of precipitation pH is 5.0, the highest month of pH is July of 5.5, and the lowest month of pH is December of 4.4. The most frequent appearance is in the range of pH 5.0 to 5.5 and its rate is 56.8%, The order of ion concentration In precipitation is SO42->NO3->Cl- in case of anion and $Ca^{2+}$>$NH_4^{+}$>$Na^+$>$Mg^{2+}$ in case of cation. It is found from our analysis that the correlation coefficient among the precipitation pH and ion components is below r=0.3, while the correlation coefficient between $SO_4^{2-}$ and NO_3^{-}$, $Na^+$ and $Cl^+$ is above r=0.8, respectively. The mean pH of precipitation is 4.8 under the westerly wind and 5.2 under the easterly wind. The concentrations of anion and cation under the westerly wind are more than the concentrations under the easterly wind. In autumn, the concentration of Na+ and $Cl^+$ under the easterly wind are higher than the concentration under the westerly wind. The correlation coefficients between wind speed and pH, ion components show very low correlation of -0.41 r 0.2. But the present study show that the correlation coefficient between wind speed and pH of precipitation is positive and the correlation coefficients between wind speed and ion concentration is negative.

  • PDF

Temporal and Spatial Characteristics of Sea Surface Winds over the Adjacent Seas of Korean Peninsular - Spectral Analysis.

  • Lee, Heung-Jae;Na, Jung-Yul;Han, Sang-Kyu
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.20-25
    • /
    • 1995
  • Surface wind field over an ocean plays a very important role not only to generate wind-driven current, but also to control heat exchange between ocean and atmosphere. However, the surface wind-field used for the ocean circulation and heat exchange is usually estimated by indirect methods because of lack of observed wind data and incomplete spatial coverage. (omitted)

  • PDF

Voltage and Transient State Analysis of Distribution Line connected to Wind Power Generation (풍력발전이 연계된 배전선로 전압 및 과도상태 해석)

  • Kim, Se-Ho;Na, Kyoung-Yoon;Kim, Gun-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.61-67
    • /
    • 2006
  • The use of the wind energy resource is a rapidly growing area world-wide. The number of installed units is continuously increasing, and therefore, it is important to respect and to deal with the impact of wind power generation system. From the view of an electric grid utility, there is a major problem with the impact of the wind system on the voltage of the electric grid, to which a turbine is connected. In this paper, it is investigated the voltage impact and transient state analysis on distribution line, with which wind power generation system is connected. Connections of wind power system usually occur to voltage drop due to reactive power absorption and sometime result in higher than nominal voltage.

Bus Voltage Analysis of Substation Connected to the Wind Generation Farm (풍력발전단지와 연계된 변전소의 모선전압 분석)

  • Kim Young Hwan;Hyun Gil Ju;Ko Seok Bum;Yang Ik Jun;Na Kyoung Yun;Kim Se Ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.236-238
    • /
    • 2004
  • In recent years wind turbine technology has undergone the rapid development in response to the demands for increased use of renewable sources of energy. Using wind turbines for production of electrical energy requires reliable operation. The increased share of wind power in electrical system makes it necessary to have grid-friendly interfaces between the wind turbines and the grid in order to maintain power quality. Increasingly wind turbines are being connected into electricity distribution system. The grid-connected wind power stations have many impacts on power systems such as voltage variations, harmonics. The paper investigates the influences of grid-connected wind power generation system on substation bus voltage.

  • PDF

Wind Stress Distribution and Its Application to the Upper-layer Structure in the East Sea of Korea (한국동해의 바람응력 분포와 상층구조에 대한 적용)

  • Na, Jung Yul
    • 한국해양학회지
    • /
    • v.23 no.3
    • /
    • pp.97-109
    • /
    • 1988
  • The wind stress and the wind-stress curl over the East Sea of Korea are computed from the ship-observed wind data by the FRDA. In order to emphasize the role of the wind in determining the upper-layer structure, rather persistent and strong winds are selected based on the wind-rose data. The monthly averaged wind stresses are comparable in size with the average value over the Japan Sea. But the monthly averaged magnitude of the wind-stress curl is very large compared to the one over the Japan Sea. This may be due to the spatial variation of the wind speeds influenced by the local orography. The wind-driven upper-layer thickness over the East Sea suggests that the site of deep upper layer indeed exists regardless of season but the position does not appear to be fixed. The convergence of warm surface water driven by the wind could be referred as the warm core.

  • PDF

Long Term Variation Trend of Wind and its Impact Upon Wind Power Generation in Taiwan

  • Na, Wang;Quan, Wan;Sheng, Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.782-788
    • /
    • 2014
  • Wind power generation has been viewed as a promising renewable energy to meet challenge of climate change. However, wind power is susceptible to climate change because previous investigation shows there are declining trends of the land surface wind speeds over middle and lower latitudes. Since long term variation trends is notably different from inter-annual random variation and could have notable impact on wind farm from planning perspective, observed meteorological data of Taiwan is investigated to find out long term variation trends of wind speed and its impact on wind power generation. It is discovered that wind speed in majority of stations in west coast of Taiwan have ascending trends while that of all investigated stations in east coast have descending trends. Since east of Taiwan is not suitable for wind power development for its higher likelihood suffering Typhoons and most of established wind farm locate in west coast of Taiwan, it is speculated that long term variation trend of wind do not have notable negative impact on wind power generation in Taiwan.

Study on the Characteristics of Concentrations and Compositions in $PM_{10}$ in Kunsan City (군산 지역에서 $PM_{10}$의 농도 및 성분 특성에 관한 연구)

  • 김성천;송재종;임성호;강달선
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.18-24
    • /
    • 2000
  • The collection of PM10 samples were collected by a PM10 hi-vol. air sampler from June, 1998 through May, 1999 in Kunsan located at western coastal region of Korea. We obtained 84 samples during sampling period. Samples were analyzed to quantify the concentration of ionic and metallic components such as SO42-, NO3-, Cl-, NH4+, K+, Na+, Mg2+, Zn, Cd, Cr, Pb and Fe. Seasonal variations of the concentrations by wind directions of each component were studied. We found that PM10 concentration had the highest level in winter and the lowest level in summer. When the wind direction is from west to east, the concentration of most ionic and metallic species were higher compared to reverse direction. That implied the effect of air pollutants from industrial area. Also, substantial amount of Na+ and Cl- were observed, which was assumed to the effect from the sea.

  • PDF

Computational Analysis and an Application of Wind Environmental Effects for High-rise Buildings (초고층건물 주변의 풍환경에 대한 수치 해석 및 적용)

  • Chung Yungbea;Na Seonuk
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.70-75
    • /
    • 2001
  • This paper presents the results of numerical simulation of wind environment and wind coefficient around super high-rise building. The analysis of aerodynamic response due to wind-induced forces and wind effect to surrounding buildings is important to high-rise building. This paper simulates the wind force to the high-rise building and wind flow pattern around the high-rise building, and shows the usability of CFD analysis to design process of high-rise building. A Navier-Stokes-Solver (FLUENT) with Quick spatial discretization scheme and RNG $\kappa-\epsilon$ turbulence model has been applied to the computation of the three dimensional turbulent flow.

  • PDF

Experiment on Collection Characteristics of Sub micron Particles in Two-Stage Parallel-Plate Electrostatic Precipitators (2단 평행판 전기집진기의 서브마이크론 입자 포집특성 실험)

  • Oh, M.D.;Yoo, K.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.237-246
    • /
    • 1994
  • Experimental data are reported for charging and collection of NaCl aerosols in the 0.03- to $0.2{\mu}m$-geometric-mean-diameter range in 2-stage parallel-plate electrostatic precipitators. The NaCl aerosols are generated with geometric standard deviation of about 1.74 and particle generation rate of about 10^9 particles/see by the constant output atomizer and injected into the air flow in the clean wind-tunnel. The 2-stage parallel-plate electrostatic precipitator installed in the test section of the wind-tunnel is operated with a positive corona discharge. The NaCl aerosols in the channel flow are sampled and transported to the aerosol particle number concentration measurement system by using the isoaxial sampling and transport system constructed based on the Okazaki and Willeke design. The aerosol particle number concentration measurement system measures the size distribution of submicrometer aerosols by an electrical mobility detection technique. It is confirmed from comparing the measured collection efficiencies in this study and the predicted ones by our previous theoretical analysis that the predicted collection efficiencies agree well with the experimental ones. It is also found from the comparison that below about $0.02{\mu}m$ all particles are not charged and the uncharged particles are not collected, and consequently 2-stage parallel-plate electrostatic precipitators are not suitable for that particle size range.

  • PDF