저온 폐열 회수용 진동형 히트 파이프 열교환기의 성능 평가에 관한 연구 (Study on Performance Evaluation of Oscillating Heat Pipe Heat Exchanger for Low Temperature Waste Heat Recovery)

  • 안영태;이욱현;김정훈;김종수
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.368-376
    • /
    • 2001
  • Performance of heat exchanger was evaluated to heat exchanger using oscillating heat pipe for waste heat recovery of low temperature. Oscillating heat pipe used in this study was formed to the closed loop of serpentine shapes using copper tubes. Heat exchanger was formed to shell and tube type and composed of low finned tube. R-22 and R-141b were used to the working fluids of tube side and their charging ratio was 40%. And, water was used to the working fluid of shell side. As the experimental parameters, the inlet temperature difference of heating and cooling part of secondary fluid and the mass velocity of secondary fluid were used. The mass velocity of secondary fluid was changed from 90 kg/$m^2s\; to\;190 kg/m^2$s from the experimental results, heat recovery rate was linearly increased to the increment of the mass velocity of secondary fluid and the inlet temperature difference of secondary fluid. Finally, the performance of heat exchanger was evaluated by using $\varepsilon$-NTU method. It was found that NTU was about 1.5 when effectiveness was decided to 80%.

  • PDF

인쇄기판형 열교환기의 유동방향 전도열전달에 관한 수치해석 연구 (Numerical Analysis on Longitudinal Heat Conduction in Printed Circuit Heat Exchanger)

  • 오동욱;김영;최준석;윤석호
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.600-604
    • /
    • 2014
  • Longitudinal heat conduction is known to be an important factor in the design of a printed circuit heat exchanger(PCHE) for cryogenic applications. Parasitic heat conduction through the heat exchanger frame needs to be considered because it is known to decrease the effectiveness of the heat exchanger. In this paper, a conjugate heat transfer problem in a simple counter-flow PCHE is analyzed by a computational fluid dynamics simulation. The effect of longitudinal conduction in a straight channel is compared with the theoretical effectiveness-NTU relationship that assumes a "thin" heat exchanger frame. The calculation results suggest that the theoretical model is valid in the present calculation conditions where NTU is < 13.

정수장에서 회전 분사 노즐을 사용한 여과사 세척에 관한 연구 (A Study on the Rotating Jet Nozzle for Washing Sand Filter in Water Purification Plant)

  • 이주호;박승헌
    • 대한안전경영과학회지
    • /
    • 제4권3호
    • /
    • pp.177-187
    • /
    • 2002
  • The contamination problem is getting worse now a day because of the industrial activities. Recently it has been announced that there's environmental hormone in river and lake which produces clean water, also there's too many of algae reproduces under the water and some virus in the drinking water. The quality of water is very important. pure and clean water is not only a precondition for human being to live but a basic factor to improve the quality of life. so a water purification system must be developed. This study is about the surface washing treatment technique. We tried to use a rotary nozzle to get a tush degree of efficiency, for it was not enough with present way of washing. The nozzle is run by water pressure. The results of the experiment are as follows. We got a clean and equal surface after washing. After washing, the water's maximum consistency was 330NTU and it shows that this way is better than before one with 215NTU. Clean level of the filter was 6$^{\circ}$and it's 2.8 times higher than 17$^{\circ}$with the old way. We can see the results that the new way of washing is more effective than old way based on this study.

플라스틱/종이 재질의 간접 증발 소자와 재생 증발 소자 성능 비교 (Performance Comparison between Indirect Evaporative Cooler and Regenerative Evaporative Cooler made of Plastic/Paper)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제17권1호
    • /
    • pp.88-98
    • /
    • 2016
  • 여름철이 무더운 대한민국에서는 냉방에 많은 전력을 소비한다. 이 경우 간접증발냉각을 동시에 적용하면 전기 사용을 줄일 수 있다. 본 연구에서는 물 퍼짐성을 개선한 플라스틱/종이 재질의 간접 및 재생증발소자에 대해 일련의 실험을 수행하였다. ${\epsilon}-NTU$ 방식의 열 및 물질전달 해석 모델과 비교한 결과 모델의 예측치는 간접 및 재생증발소자의 간접증발효율, 냉각열량, 압력손실을 적절히 예측하였다. 모델 해석 결과 간접 및 재생증발소자 모두 건채널 입구온도와 상대습도가 증가하면 간접증발효율이 증가하였다. 또한 재생증발소자의 간접증발효율이 간접증발소자의 값보다 크게 나타났다.

탁도에 따른 Echo Sounder 관측 한계 분석 (Analysis of Measuring Limit of Echo Sounding by Turbidity)

  • 김용보
    • 한국측량학회지
    • /
    • 제23권2호
    • /
    • pp.197-203
    • /
    • 2005
  • 연안에서의 준설, 매립, 항만건설 등의 공사 시 해상에서의 측량 조건에 따른 수심측량의 효율성과 정밀도에 대한 관심이 매우 높아지고 있다. 그러나 측량조건에 따른 수심측량의 정밀도 향상에 대한 연구는 부족한 실정이다. 수심측량의 정밀도 저하 요인 중 본 연구에서는 탁도 증가에 따른 echo sounder의 측심 특성 파악과 한계 탁도 구간을 제시하고자 하였다. 이를 위해, 인공수조에 탁도 유발물질을 인위적으로 투입하여 탁도 별 수심측정 값을 취득한 후, 회귀분석을 수행하여 탁도 증가에 따른 측심 특성이 정상관측구간, 한계구간, 관측불가능구간의 순으로 이루어지고 탁도에 대한 echo sounder 수심관측 한계구간이 $217\~259NTU$로 나타났다.

압력식 급속 자동 여과장치의 여과성능 평가 (The Performance Estimation of Pressure-Type Rapid Automatic Filter)

  • 김덕진;유해성;신상윤
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.607-612
    • /
    • 2006
  • A pressure-type rapid automatic filter of 2000mm diameter and 170 ton/h filtering capacity was fabricated. In case of no external impurity inflow, the turbidity removal efficiency on raw water was experimented and the numbers of impurities of each sizes were analyzed by particle counter. As the result of circulated filtering, the raw water of 40 NTU was filtered to 0.44 NTU and the numbers of impurities above $1{\mu}m$ were removed by approximately 95%. With the filtering efficiency experimented and the mathematical method, the turbidity change of circulation water were calculated according to the inflow rate of external impurity and water treatment method of blow-down or filtering. The cost of blow-down water was calculated from above results. And simple payback period for this filter is calculated as about one year. Nowadays, as the cost of water is continuously increasing and environment regulations will be more strict, the water quality control using this filter will be expected to satisfy the user requirement.

  • PDF

제주도 기후변화 관련 상수도시설 취약성 평가 및 적응대책 (Water utilities vulnerability assessment and adaption strategies for climate change in Jeju province)

  • 김진근
    • 상하수도학회지
    • /
    • 제32권6호
    • /
    • pp.517-526
    • /
    • 2018
  • Climate adaptation strategies for water utilities including 16 water treatment plants(WTPs) in Jeju were investigated. Drought, heat wave, and heavy rain were among the most significant climate factors affecting water utilities in Jeju. Heat wave increases water temperature, which in turn increases the concentration of algae, color, and odor materials. Some adaption strategies for the heat wave can be strengthening water monitoring and introducing advanced water treatments. Heavy rain increases raw water turbidity in surface water. The 7 WTPs that take raw water from streams or springs had a maximum turbidity of less than 50 NTU under heavy rain. However, due to concerns of turbidity spike in treated water, some WTPs discontinued intaking raw water when raw water turbidity increased more than 2 NTU. They instead received treated water from other WTPs which took groundwater for water supply. This happens because of the low skills of employees. Thus, there needs to be an increase in operator competency and upgrade of water facilities for the adaption of heavy rain. To improve adaption for the drought, there should be an increase in the capacity of intake facilities of surface water as well as a decrease in water loss. In addition, water consumption per person should be decreased.

몰입형 대형 사이니지 콘텐츠를 위한 STAGCN 기반 인간 행동 인식 시스템 (STAGCN-based Human Action Recognition System for Immersive Large-Scale Signage Content)

  • 김정호;황병선;김진욱;선준호;선영규;김진영
    • 한국인터넷방송통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.89-95
    • /
    • 2023
  • 인간 행동 인식 (Human action recognition, HAR) 기술은 스포츠 분석, 인간과 로봇 간의 상호작용, 대형 사이니지 콘텐츠 등의 애플리케이션에 활용되는 핵심 기술 중 하나이다. 본 논문에서는 몰입형 대형 사이니지 콘텐츠를 위한 STAGCN (Spatial temporal attention graph convolutional network) 기반 인간 행동 인식 시스템을 제안한다. STAGCN은 attention mechanism을 통해 스켈레톤 시퀀스의 시공간적 특징에 서로 다른 가중치를 부과하여, 동작 인식에 중요한 관절 및 시점을 고려할 수 있다. NTU RGB+D 데이터셋을 사용한 실험 결과, 제안된 시스템은 기존 딥러닝 모델들에 비해 높은 분류 정확도를 달성한 것을 확인했다.

D정수장 정밀여과막 실증플랜트의 최적 운전조건 연구 (A Study on Operating Condition of Test-Bed Plant using Membrane filtration of D Water Treatment Plant in Gwang-Ju)

  • 양형재;이승훈;문경란
    • 대한환경공학회지
    • /
    • 제39권3호
    • /
    • pp.155-163
    • /
    • 2017
  • 최근 막여과 공정은 입자상 물질뿐만 아니라 Giardia, cryptosporidium과 같은 병원성미생물이 효과적으로 제거됨에 따라 국내외 적용성이 확대되는 추세이다. 본 연구는 광주광역시 D정수장의 원수 침전상등수의 처리를 위해 $120m^3/d$ 처리규모의 Pilot Plant (2014. 1월부터 운영)와 $2,500m^3/d$ 처리규모의 실증실험시설(2015. 1월부터 운영)의 막여과 공정을 운영하면서 최적 운전조건과 한계여과속도를 찾고자 하였다. 정밀여과막의 Pilot-test에서 얻어진 운전모드는 유입 1.0분, 여과 36.5분, 공기역세 0.9분, 역세 1.0분, 배출 1.0분이었으며, 이를 적용하여 실증실험을 하였다. 한계여과속도(critical flux)는 Pilot 운전에서 Flux 20, 40, 56 및 62 LMH일 때의 시간의 변화에 따른 막간차압의 증가식을 기반으로 $50L/m^2-h$로 산정(TMP 0.5bar 이내)되었다. 화학세정은 1차로 산세정 2회, 2차로 알칼리 세정을 하여 95%의 회복율을 얻었다. 이러한 적정 조건으로 운전한 결과 처리수의 탁도는 봄 여름 가을 겨울 평균 각각 0.028, 0.024, 0.026 및 0.028 NTU, 연평균 탁도는 0.026 NTU로, 탁도 제거율은 98.4%로 나타났다. 광주광역시 D정수장의 원수 침전상등수를 1일 $2,500m^3$ 처리하는 실증실험시설 운영을 통해 부유고형물 및 콜로이드성 물질을 제거하는데 탁월한 처리성능을 확인하였고, 일반적인 모래여과공정을 대체할 수 있는 적정운영기술이 확보되었다.

BNR공정 처리수의 여과에 관한 연구 (A Study on the Filtration of BNR Process Effluent)

  • 김성용;범봉수;조광명
    • 대한환경공학회지
    • /
    • 제22권5호
    • /
    • pp.895-905
    • /
    • 2000
  • 본 연구는 여재가 모래와 무연탄인 복층 중력식 급속여과법으로 BNR(biological nutrient removal) 공정 유출수를 처리할 때 여과율의 변화에 따른 오염물질 제거효율 및 여층 깊이별 처리수질을 파악하기 위하여 수행되었다. Pilot scale의 4-stage BNR 공정 유출수를 200, 300 및 400 m/day의 여과율로 급속여과시킨 결과, 처리수는 2.6 NTU 이하의 탁도를 나타내어 우리나라의 중수도 제한수질인 5.0 NTU를 만족하였다. 여과율이 200, 300 및 400 m/day로 증가함에 따라 SS 제거효율은 각각 80.6, 75.4 및 68.9%로 감소하는 경향을 보였지만, 여과수는 모든 여과율에서 유입수의 수질변화에 큰 영향을 받지 않고 평균 1.3 mg/L의 SS 농도를 보였다. 생물학적 작용에 의하여 영양염류도 제거되었는데, 200, 300 및 400 m/day의 여과율에서 질산화효율이 각각 17.4, 18.8 및 14.3%, 그리고 탈질효율이 각각 32.3, 27.7 및 21.4%로, 질산화와 탈질이 동시에 일어났다. 여과주기의 후반기에는 여층 내의 DO가 결핍됨에 따라 인의 재용출이 일어남으로써 유출수의 T-P 농도가 유입수에 비하여 6.1~21.4% 증가하였다.

  • PDF