• Title/Summary/Keyword: NRI

Search Result 51, Processing Time 0.019 seconds

[Retracted]Assessing Nutritional Status in Outpatients after Gastric Cancer Surgery: A Comparative Study of Five Nutritional Screening Tools ([논문철회]위암 수술 후 외래환자의 영양상태 평가: 5가지 영양검색도구의 비교연구)

  • Cho, Jae Won;Youn, Jiyoung;Choi, Min-Gew;Rha, Mi Young;Lee, Jung Eun
    • Korean Journal of Community Nutrition
    • /
    • v.26 no.4
    • /
    • pp.280-295
    • /
    • 2021
  • Objectives: This study aimed to examine the characteristics of patients according to their nutritional status as assessed by five nutritional screening tools: Patient-Generated Subjective Global Assessment (PG-SGA), NUTRISCORE, Nutritional Risk Index (NRI), Prognostic Nutritional Index (PNI), and Controlling Nutritional Status (CONUT) and to compare the agreement, sensitivity, and specificity of these tools. Methods: A total of 952 gastric cancer patients who underwent gastrectomy and chemotherapy from January 2009 to December 2012 at the Samsung Medical Center were included. We categorized patients into malnourished and normal according to the five nutritional screening tools 1 month after surgery and compared their characteristics. We also calculated the Spearman partial correlation, Cohen's Kappa coefficient, the area under the curve (AUC), sensitivity, and specificity of each pair of screening tools. Results: We observed 86.24% malnutrition based on the PG-SGA and 85.82% based on the NUTRISCORE among gastric cancer patients in our study. When we applied NRI or CONUT, however, the malnutrition levels were less than 30%. Patients with malnutrition as assessed by the PG-SGA, NUTRISCORE, or NRI had lower intakes of energy and protein compared to normal patients. When NRI, PNI, or CONUT were used to identify malnutrition, lower levels of albumin, hemoglobin, total lymphocyte count, total cholesterol, and longer postoperative hospital stays were observed among patients with malnutrition compared to those without malnutrition. We found relatively high agreement between PG-SGA and NUTRISCORE; sensitivity was 90.86% and AUC was 0.78. When we compared NRI and PNI, sensitivity was 99.64% and AUC was 0.97. AUC ranged from 0.50 to 0.67 for comparisons between CONUT and each of the other nutritional screening tools. Conclusions: Our study suggests that PG-SGA and NRI have a relatively high agreement with the NUTRISCORE and PNI, respectively. Further cohort studies are needed to examine whether the nutritional status assessed by PG-SGA, NUTRISCORE, NRI, PNI, and CONUT predicts the gastric cancer prognosis.

Magnetotransport Properties of MnAs Film on GaAs(001) Substrate

  • Sinsarp Asawin;Manago Takashi;Akinaga Hiroyuki
    • Journal of Magnetics
    • /
    • v.11 no.1
    • /
    • pp.5-7
    • /
    • 2006
  • The magnetotransport properties at room temperature of the 250-nm-thick MnAs(-1100) film grown on GaAs(001) substrate by molecular beam epitaxy was investigated. The results measured with various magnetic field directions were reported. They show the negative magnetoresistive effect for all field directions. The difference in the magnetoresistance curves for different field directions is in agreement with the magnetic anisotropy of the film.

Epitaxial Growth and Characterization of Zinc-blende CrAs/GaAs/MnAs/GaAs Multilayers

  • Wang W.H.;Manago T.;Akinaga H.
    • Journal of Magnetics
    • /
    • v.11 no.1
    • /
    • pp.1-4
    • /
    • 2006
  • We report on the growth, structural and transport properties of zinc-blende CrAs/GaAs/MnAs/GaAs multilayers on GaAs(001) substrates. Structural analyses using in-situ reflection high-energy electron diffraction and exsitu cross-sectional transmission electron microscopy confirmed the realization of a zinc-blende crystal structure. Room temperature Hall measurements reveal that the as-grown multilayer exhibits p-type conductivity with a very low resistivity of $0.052\;\omega{cm}$, a high carrier concentration of $6.2X10^{19}\;cm^{-3}$ and a Hall mobility of $1.8\;cm^2/Vs$. We also observed a clear decrease of the resistivity in samples after low temperature annealing.

Novel Planar Metamaterial with a Negative Refractive Index

  • Kim, Dong-Ho;Choi, Jae-Ick
    • ETRI Journal
    • /
    • v.31 no.2
    • /
    • pp.225-227
    • /
    • 2009
  • A new planar metamaterial (MTM) with simultaneous negative values of permittivity (${\varepsilon}$) and permeability (${\mu}$) is proposed. Our MTM is composed of two identical copper patterns etched on both sides of dielectric laminate, which is very thin and easy to fabricate. Unlike conventional MTMs, the proposed structure shows a negative refractive index (NRI) behavior with respect to a normally incident wave. To explain the underlying principle of the NRI characteristics, an equivalent resonant circuit model based on surface current density distribution is investigated. An eigenmode analysis and a three-dimensional wave simulation for the stacked MTM prism are also performed to verify the existence of negative refraction. The experimental results from the transmission and reflection measurement ensure the validity of our design approach and show good agreement with the theoretically predicted effective medium parameters.

  • PDF

Actual 5-Year Nutritional Outcomes of Patients with Gastric Cancer

  • Kim, Ki Hyun;Park, Dong Jin;Park, Young Suk;Ahn, Sang Hoon;Park, Do Joong;Kim, Hyung Ho
    • Journal of Gastric Cancer
    • /
    • v.17 no.2
    • /
    • pp.99-109
    • /
    • 2017
  • Purpose: In this study, we aimed to evaluate the rarely reported long-term nutritional results of patients with gastric cancer after curative gastrectomy. Materials and Methods: We retrospectively reviewed the prospectively collected medical records of 658 patients who underwent radical gastrectomy with curative intent for gastric cancer from January 2008 to December 2009 and had no recurrences. All patients were followed for 5 years. Nutritional statuses were assessed using measurements of body weight, serum hemoglobin, total lymphocyte count (TLC), protein, albumin, cholesterol, and nutritional risk index (NRI). Results: Patients who underwent total gastrectomy had lower body weights, hemoglobin, protein, albumin, and cholesterol levels. TLC and NRI values after the first postoperative year (P<0.05), and lower hemoglobin and NRI values during the fifth postoperative year than patients who underwent distal gastrectomy (P<0.05). Patients who received adjuvant chemotherapy after gastrectomy had lower hemoglobin, protein, albumin, and cholesterol levels. TLC and NRI values during the first postoperative year, than those who underwent gastrectomy only (P<0.05). Regarding post-distal gastrectomy reconstruction, those who underwent Roux-en-Y had lower cholesterol levels than did those who underwent Billroth-I and Billroth-II reconstruction at the first and fifth years after gastrectomy, respectively (P<0.05). Conclusions: Patients undergoing total or distal gastrectomy with Roux-en-Y anastomosis or adjuvant chemotherapy after surgery should be monitored carefully for malnutrition during the first postoperative year, and patients undergoing total gastrectomy should be monitored for malnutrition and anemia for 5 years.

Predicting the Soluble Solids of Apples by Near Infrared Spectroscopy (I) - Multiple Linear Regression Models - (근적외선을 이용한 사과의 당도예측 (I) - 다중회귀모델 -)

  • ;W. R. Hruschka;J. A. Abbott;;B. S. Park
    • Journal of Biosystems Engineering
    • /
    • v.23 no.6
    • /
    • pp.561-570
    • /
    • 1998
  • The MLR(Multiple Linear Regression) models to estimate soluble solids content non-destructively were presented to make a selection of optimal photosensor utilized to measure the soluble solids content of apples. Visible and NIR absorbance in the 400 to 2498 nanometer(nm) wavelength region, soluble solids content(sugar content), hardness, and weight were measured for 400 apples(gala). Spectrophotometer with fiber optic probe was utilized for spectrum measurement and digital refractometer was used for soluble solids content. Correlation between absorbance spectrum and soluble solids content was analyzed to pick out the optimal wavelengths and to develop corresponding prediction model by means of MLR. For the coefficient of determination($R^2$) to be over 0.92, the MLR models out of the original absorbance were built based on 7 wavelengths of 992, 904, 1096, 1032, 880, 824, 1048nm, and the ones of the second derivative absorbance based on 5 wavelengths of 784, 1056, 992, 808, 872nm. The best model of the second derivative absorbance spectrum had $R^2$=0.91, bias= -0.02bx, SEP=0.28bx for unknown samples.

  • PDF

Predicting the Soluble Solids of Apples by Near Infrared Spectroscopy (II) - PLS and ANN Models - (근적외선을 이용한 사과의 당도예측 (II) - 부분최소제곱 및 인공신경회로망 모델 -)

  • ;W. R. Hruschka;J. A. Abbott;;B. S. Park
    • Journal of Biosystems Engineering
    • /
    • v.23 no.6
    • /
    • pp.571-582
    • /
    • 1998
  • The PLS(Partial Least Square) and ANN(Artificial Neural Network) were introduced to develop the soluble solids content prediction model of apples which is followed by making a subsequent selection of photosensor. For the optimal PLS model, number of factors needed for spectrum analysis were increased until the convergence of prediction residual error sum of squares. Analysis has shown that even part of the overall wavelength with no pretreatment may turn out better performing. The best PLS model was found in the 800 to 1,100nm wavelength region without pretreatment of second derivation, having $R^2$=0.9236, bias= -0.0198bx, SEP=0.2527bx for unknown samples. On the other hand, for the ANN model the second derivation led to higher performance. On partial range of 800 to 1,100nm wavelengh region, prediction model with second derivation for unknown samples reached $R^2$=0.9177, SEP=0.2903bx in contrast to $R^2$=0.7507, SEP =0.4622bx without pretreatment.

  • PDF