• Title/Summary/Keyword: NPP communication

Search Result 28, Processing Time 0.025 seconds

Public Perception and Communication Patterns Pertaining to Nuclear Power in Korea: Focusing on the Transition Period from Pro-nuclear to De-nuclear Policy

  • Eunok Han;Yoonseok Choi
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.226-236
    • /
    • 2022
  • Background: An effective communication strategy for reducing conflicts in South Korea has been designed through the analysis of public perception and communication variables on nuclear power under the conditions of rapidly changing nuclear power policies. Materials and Methods: This study conducted both qualitative research through group discussions based on social psychology and quantitative research through surveys. Results and Discussion: Nuclear power plant (NPP) area residents in favor of nuclear power indicated higher levels of communication, safety perception, and contribution than those against it. NPP area residents trusted the civilian expert groups (18.3%) and local government (17.3%) the most, while metropolitan city residents trusted the Nuclear Safety and Security Commission and the Korea Institute of Nuclear Safety (20.7%) the most. In determining nuclear power policy, both the NPP area residents (18.1%) and metropolitan city residents (17.1%) prioritized safety, health, and the environment. While metropolitan city residents thought that energy security and economic growth (16.4%) were important, NPP area residents thought the current issue of spent fuel rods (14.1%) to be important. Conclusion: It is necessary for the nuclear power industry to have and actively implement communication and conflict resolution strategies based on the patterns obtained in the study results.

The Nuclear Related Organization Workers' Perceptions about Nuclear Power Plant News in Korea (국내 원전보도에 관한 원자력 유관 산업 종사자들의 인식)

  • Choi, Sook
    • Journal of Digital Convergence
    • /
    • v.12 no.7
    • /
    • pp.85-93
    • /
    • 2014
  • The Press related Energy including nuclear energy has social responsibility that it should pass the scientific factors to the right. It is essential to ensure the accuracy and fairness. The general public, such as press releases and information obtained through indirect communication affects social acceptance of nuclear power, which is used to determine the direction of energy policy, the most important factor to be taken into account. Recent rapid increase coverage of NPP lose in balance of nuclear power plants. In this study the qualitative interviews were performed with the workers who stand directly in obtaining information about nuclear related organizations. By E-mail and FGI the data were collected from the workers' perception about domestic nuclear news. They perceived the NPP news that the negative aspects of nuclear power plants were too much dealt in nuclear news coverage, and risk of NPP is only exaggerated and distorted, the lack of expertise knowledge on nuclear power and recognize that the cause was a lack of understanding. 'Nuclear mah' for the event were aware that should dig more thoroughly. The Journal of Digital Policy & Management.

Optimal Two Degrees-of-Freedom Based Neutral Point Potential Control for Three-Level Neutral Point Clamped Converters

  • Guan, Bo;Doki, Shinji
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.119-133
    • /
    • 2019
  • Although the dual modulation wave method can solve the low-frequency neutral point potential (NPP) fluctuation problem for three-level neutral point clamped converters, it also increases the switching frequency and limits the zero-sequence voltage. That makes it harmful when dealing with the NPP drift problem if the converter suffers from a long dead time or asymmetric loads. By introducing two degrees of freedom (2-DOF), an NPP control based on a search optimization method can demonstrate its ability to cope with the above mentioned two types of NPP problems. However, the amount of calculations for obtaining an optimal 2-DOF is so large that the method cannot be applied to certain industrial applications with an inexpensive digital signal processor. In this paper, a novel optimal 2-DOF-based NPP control is proposed. The relationships between the NPP and the 2-DOF are analyzed and a method for directly determining the optimal 2-DOF is also discussed. Using a direct calculation method, the amount of calculations is significantly reduced. In addition, the proposed method is able to maintain the strongest control ability for the two types of NPP problems. Finally, some experimental results are given to confirm the validity and feasibility of the proposed method.

Implementation Plan and Requirements Analysis of Access Control for Cyber Security of Nuclear Power Plants (원전 사이버보안을 위한 접근제어 요건분석 및 구현방안)

  • Kim, Do-Yeon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • The Nuclear Power Plants(: NPP) are being protected as national infrastructure, and instrumentation and control(: I&C) systems are one of the principle facilities of the NPP, which perform the protection, control, and monitoring function. The I&C systems are being evolved into digitalization based on computer and network technology from analog system. In addition, the I&C systems are mostly employ the specialized logic controllers which are dedicated for the NPP, but the usage of generalized IT resources are steadily increased. The cyber security issues for the NPP are being emerged due to cyber incidents by Stuxnet and various accidents in the NPP. In this paper, hybrid access control model is proposed which are applicable to I&C system by analyzing the access control requirements specified in regulatory guides. The safety of in-service and under construction of NPP are effectively increased by applying proposed hybrid model.

Syntactic and semantic information extraction from NPP procedures utilizing natural language processing integrated with rules

  • Choi, Yongsun;Nguyen, Minh Duc;Kerr, Thomas N. Jr.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.866-878
    • /
    • 2021
  • Procedures play a key role in ensuring safe operation at nuclear power plants (NPPs). Development and maintenance of a large number of procedures reflecting the best knowledge available in all relevant areas is a complex job. This paper introduces a newly developed methodology and the implemented software, called iExtractor, for the extraction of syntactic and semantic information from NPP procedures utilizing natural language processing (NLP)-based technologies. The steps of the iExtractor integrated with sets of rules and an ontology for NPPs are described in detail with examples. Case study results of the iExtractor applied to selected procedures of a U.S. commercial NPP are also introduced. It is shown that the iExtractor can provide overall comprehension of the analyzed procedures and indicate parts of procedures that need improvement. The rich information extracted from procedures could be further utilized as a basis for their enhanced management.

Digital Asset Analysis Methodology against Cyber Threat to Instrumentation and Control System in Nuclear Power Plants (원자력발전소의 디지털계측제어시스템의 사이버보안을 위한 디지털 자산분석 방법)

  • Koo, In-Soo;Kim, Kwan-Woong;Hong, Seok-Boong;Park, Geun-Ok;Park, Jae-Yoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.6
    • /
    • pp.839-847
    • /
    • 2011
  • Instrumentation & Control(I&C) System in NPP(Nuclear Power Plant) plays a important role as the brain of human being, it performs protecting, controling and monitoring safety operation of NPP. Recently, the I&C system is digitalized as digital technology such as PLC, DSP, FPGA. The different aspect of digital system which use digital communication to analog system is that it has potential vulnerability to cyber threat in nature. Possibility that digital I&C system is defected by cyber attack is increasing day by day. The result of cyber attack can be adverse effect to safety function in NPP. Therefore, I&C system required cyber security counter-measures that protect themselves from cyber threat efficiently and also cyber security design should be taken into consideration at concept stage in I&C system development process. In this study, we proposed the digital asset analysis method for cyber security assessment of I&C system design in NPP and we performed digital asset analysis of I&C system by using the proposed method.

Influence and analysis of a commercial ZigBee module induced by gamma rays

  • Shin, Dongseong;Kim, Chang-Hwoi;Park, Pangun;Kwon, Inyong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1483-1490
    • /
    • 2021
  • Many studies are undertaken into nuclear power plants (NPPs) in preparation for accidents exceeding design standards. In this paper, we analyze the applicability of various wireless communication technologies as accident countermeasures in different NPP environments. In particular, a commercial wireless communication module (WCM) is investigated by measuring leakage current and packet error rate (PER), which vary depending on the intensity of incident radiation on the module, by testing at a Co-60 gamma-ray irradiation facility. The experimental results show that the WCMs continued to operate after total doses of 940 and 1097 Gy, with PERs of 3.6% and 0.8%, when exposed to irradiation dose rates of 185 and 486 Gy/h, respectively. In short, the lower irradiation dose rate decreased the performance of WCMs more than the higher dose rate. In experiments comparing the two communication protocols of request/response and one-way, the WCMs survived up to 997 and 1177 Gy, with PERs of 2% and 0%, respectively. Since the request/response protocol uses both the transmitter and the receiver, while the one-way protocol uses only the transmitter, then the electronic system on the side of the receiver is more vulnerable to radiation effects. From our experiments, the tested module is expected to be used for design-based accidents (DBAs) of "Category A" type, and has confirmed the possibility of using wireless communication systems in NPPs.

A Systems Engineering Approach to Real-Time Data Communication Network for the APR1400

  • Ibrahim, Ahmad Salah;Jung, Jae-cheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.13 no.2
    • /
    • pp.9-17
    • /
    • 2017
  • Concept development of a real-time Field Programmable Gate Array (FPGA)-based switched Ethernet data communication network for the Man-Machine Interface System (MMIS) is presented in this paper. The proposed design discussed in this research is based on the systems engineering (SE) approach. The design methodology is effectively developed by defining the concept development stage of the life-cycle model consisting of three successive phases, which are developed and discussed: needs analysis; concept exploration; and concept definition. This life-cycle model is used to develop an FPGA-based time-triggered Ethernet (TTE) switched data communication network for the non-safety division of MMIS system to provide real-time data transfer from the safety control systems to the non-safety division of MMIS and between the non-safety systems including control, monitoring, and information display systems. The original IEEE standard 802.3 Ethernet networks were not typically designed or implemented for providing real-time data transmission, however implementing a network that provides both real-time and on-demand data transmission is achievable using the real-time Ethernet technology. To develop the design effectively, context diagrams are implied. Conformance to the stakeholders needs, system requirements, and relevant codes and standards together with utilizing the TTE technology are used to analyze, synthesize, and develop the MMIS non-safety data communication network of the APR1400 nuclear power plant.

Performance Analysis of the Mid-Level Communication Network for DCS in NPP (원자력 발전소 분산제어 시스템을 위한 중위 계층 통신망의 성능 분석)

  • Lee, Sung-Woo;Yim, Han-Suck
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.816-818
    • /
    • 1998
  • In this paper, a highly reliable communication network for DCS (Distributed Control System) in nuclear power plant is designed. The structure and characteristics of DCS in nuclear power plant is briefly explained. The features needed for a communication network for DCS in nuclear power plant is described. According to the above features, a layer structure for the communication network is determined and each layer is designed in detail. Accuracy of the model was evaluated by computer simulation.

  • PDF

Leakage Rates Measurement System Development of NPP Primary Containment using Wireless Data Communication Method (원전 격납건물 누설시험용 무선데이터전송을 적용한 시험장치 개발)

  • Ryu, Jae-Kyu;Sohn, Chang-Ho;Hwang, Hee-Jung;Kim, Gun-Soo;Choi, Kyong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.916-919
    • /
    • 2003
  • In this paper, we deal with a development of measurement system to apply the leakage rates test of primary containment in nuclear power plant. The measurement test about leakage rates in primary containment is one sort of test to prove safety of nuclear power plant. The parameters which are measured to calculate leakage rates are drybulb temperature, dew point temperature(or relative humidity), absolute pressure and flow. Overall, the measurement system consists of sensor module for data acquisition of the parameters, transfer module for wireless data communication and control module to control system and to calculate leakage rates. Because existing measurement systems are difficult to set in field, we pursued convenience of use, we applied wireless data communication and individual form module using battery. We also changed for the better in confidence. Recently, we are developing a drybulb temperature and a dew point temperature sensor module. We describe about function of developed measurement system, its standard and an plan for verification of measurement system.

  • PDF