• 제목/요약/키워드: NPC multi-level inverter

검색결과 20건 처리시간 0.023초

트랩필터를 갖는 NPC멀티레벨 인버터의 LCR필터 차단주파수 설정에 따른 출력특성 분석 (The Output Characteristics Analysis by Cut-off Frequency Set-up of the LCR Filter on NPC Multi-Level Inverter with Trap-Filter)

  • 김수홍;김윤호
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.892-897
    • /
    • 2007
  • This paper presents the output filter design and the output characteristic analysis by cut-off frequency set up of the LCR filter on NPC multi-level inverter with trap-filter. The single-phase NPC three-level inverter operates at low switching frequency. The proposed LC trap filter is comprised of a conventional LCR output filter, by using LC trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also. low damping resistor is increased the output filter system. The multilevel inverter system used NPC type inverter in proper system for high power application and controller is used DSP(TMS320C31). The effectiveness of proposed system confirmed the validity through SPICE simulation and experimental results.

고조파 저감을 위한 단상 NPC 멀티레벨 PWM 인버터의 LC트랩 필터 설계 (LC Trap Filter Design of Single Phase NPC Multi-Level PWM Inverters for Harmonic Reduction)

  • 김윤호;이재학;김수홍
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.313-320
    • /
    • 2006
  • 본 논문에서는 단상 NPC 멀티레벨 인버터의 출력단 고조파 저감을 위한 LC 트랩 필터의 설계 방법을 제시하였고, 출력전압 THD와 출력전류 고조파 FFT 분석을 수행하였다. 제시된 LC 트랩 필터는 일반적인 LCR 필터와 종속 접속된 구조를 가지며, 스위칭 주파수에 동조되었다. 인버터 시스템은 고전력 응용에 적합한 NPC 멀티레벨 인버터를 사용하였으며, 제어기는 DSP(TMS320C31)을 사용하여 구성하였다. 제안된 시스템의 효용성은 시뮬레이션과 실험 결과를 통하여 증명하였다.

LC트랩필터를 갖는 단상 NPC 멀티레벨 인버터의 출력 고조파 저감 및 필터 효율 분석에 관한 연구 (A Study on Filter Efficiency Analysis and Harmonic Reduction of Single Phase NPC Multi-Level Inverter with LC-Trap Filter)

  • 김수홍;서강문;김윤호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권8호
    • /
    • pp.430-435
    • /
    • 2006
  • This paper presents a method about the efficiency analysis and the harmonic reduction of single phase NPC multi-level inverter with LC-trap filter and LCR output filter. The proposed LC-trap filter is comprised of a conventional LC output filter, by using LC-trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also, low damping resistor is increased the efficiency of the output filter. Experimental verification of the proposed circuit is provided with single phase NPC multilevel inverter system and DSP controller.

간단한 구조를 갖는 새로운 방식의 멀티 레벨 인버터에 관한 연구 (The study of New multi-level inverter with simple structure)

  • 이병진;정병창;유철로;이성룡;한우용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1963-1965
    • /
    • 1998
  • In this paper, a new simplified configuration for a multi-level PWM inverter is proposed. The proposed inverter consists of an auxiliary circuit with one switching device, and 3 phase full-bridge inverter. The proposed inverter, in spite of reduction of the switching devices, offers characteristics similar to the NPC(Neutral - point - clamped)- PWM inverter. Also, since the reduction of the switching devices, the control strategy is simplified. And switching loss is reduced. In addition to, it is possible that reliable DC level voltage than former multi-level inverter. And load power application is same to conventional NPC-PWM inverter. The performance of the system is verified by simulation. In this paper, show the simulation result of the single phase full bridge inverter application.

  • PDF

NPC 3-레벨 인버터의 스위치 고장시 고장 진단과 중성점 불평형 전압 제어 (Fault Diagnosis and Neutral Point Voltage Control Under the Switch Fault in NPC 3-Level Voltage Source Inverter)

  • 김태진;강대욱;현동석;손호인
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권5호
    • /
    • pp.231-237
    • /
    • 2005
  • Many conventional multi-level inverters have detected switching faults by using the over voltage and current. However, fault detection of the switching elements is very difficult because the voltage and current due to each switching fault decrease more than the normal operation. Moreover, the dc-link unbalancing voltage causes a serious problem in the safety and reliability of system when the 3-level inverter faults occur Therefore, this paper proposes the simple fault diagnose method and the neutral-point-voltage control method that can protect the 3-level inverter system from the unbalancing voltage of the do-link capacitors when the faults of switching elements occur in the 3-level inverter that is very efficient in ac motor drives of the high voltage and high power applications. Through experiment results, the validity of the proposed method is demonstrated.

Investigations of Multi-Carrier Pulse Width Modulation Schemes for Diode Free Neutral Point Clamped Multilevel Inverters

  • Chokkalingam, Bharatiraja;Bhaskar, Mahajan Sagar;Padmanaban, Sanjeevikumar;Ramachandaramurthy, Vigna K.;Iqbal, Atif
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.702-713
    • /
    • 2019
  • Multilevel Inverters (MLIs) are widely used in medium voltage applications due to their various advantages. In addition, there are numerous types of MLIs for such applications. However, the diode-less 3-level (3L) T-type Neutral Point Clamped (NPC) MLI is the most advantageous due to its low conduction losses and high potential efficiency. The power circuit of a 3L T-type NPC is derived by the conventional two level inverter by a slight modification. In order to explore the MLI performance for various Pulse Width Modulation (PWM) schemes, this paper examines the operation of a 3L (five level line to line) T-type NPC MLI for various types of Multi-Carriers Pulse Width Modulation (MCPWM) schemes. These PWM schemes are compared in terms of their voltage profile, total harmonic distortion (THD) and conduction losses. In addition, a 3L T-type NPC MLI is also compared with the conventional NPC in terms of number of switches, clamping diodes, main diodes and capacitors. Moreover, the capacitor-balancing problem is also investigated using the Neutral Point Fluctuation (NPF) method with all of the MCPWM schemes. A 1kW 3L T-type NPC MLI is simulated in MATLAB/Simulink and implemented experimentally and its performance is tested with a 1HP induction motor. The results indicate that the 3L T-type NPC MLI has better performance than conventional NPC MLIs.

멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동 전력필터 (A Hybrid Active Power Filter for Electric-Railway Systems Using Multi-Level Inverters)

  • 김윤호;김수홍;이강희
    • 한국철도학회논문집
    • /
    • 제7권4호
    • /
    • pp.339-344
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 3rd harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system.

Cascaded NPC/H-bridge 멀티 레벨 인버터의 전력 및 손실 분배를 위한 새로운 Level-Shift PWM 기법 (Novel Level-Shift PWM for Power and Loss Distribution of Cascaded NPC/H-bridge Multi Level Inverter)

  • 하재옥;강진욱;현승욱;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.270-271
    • /
    • 2017
  • Cascaded NPC/H-bridge 인버터의 기존 Level-Shift PWM에서는 한 stack에서 전력 및 손실 불균형이 발생하게 된다. 이에 따라 손실 불균형을 개선하기 위해 새로운 Level Shift PWM을 개발하였고, PSIM 9.14를 통해 기존의 PWM 기법들과 비교 분석 하였다.

  • PDF

The Optimized Design of a NPC Three-Level Inverter Forced-Air Cooling System Based on Dynamic Power-loss Calculations of the Maximum Power-Loss Range

  • Xu, Shi-Zhou;He, Feng-You
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1598-1611
    • /
    • 2016
  • In some special occasions with strict size requirements, such as mine hoists, improving the design accuracy of the forced-air cooling systems of NPC three-level inverters is a key technology for improving the power density and decreasing the volume. First, a fast power-loss calculation method was brought. Its calculation principle introduced in detail, and the computation formulas were deduced. Secondly, the average and dynamic power losses of a 1MW mine hoist acting as the research target were analyzed, and a forced-air cooling system model based on a series of theoretical analyses was designed with the average power loss as a heat source. The simulation analyses proves the accuracy and effectiveness of this cooling system during the unit lifting period. Finally, according to an analysis of the periodic working condition, the maximum power-loss range of a NPC three-level inverter under multi cycle operation was obtained and its dynamic power loss was taken into the optimized cooling system model as a heat source to solve the power device damage caused by instantaneous heat accumulation. The effectiveness and feasibility of the optimization design based on the dynamic power loss calculation of the maximum power-loss range was proved by simulation and experimental results.

멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동전력필터 (A Hybrid Active Power Filter for Electric-Railway Systems using Multi-Level Inverters)

  • 김윤호;김수홍;노성찬;이강희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1334-1339
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. Transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 5th harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system.

  • PDF