• 제목/요약/키워드: NPC converter

검색결과 55건 처리시간 0.032초

직류 배전망 연계를 위한 3상 13.2kV급 반도체 변압기 시스템에 대한 연구 (A Study on the 3-phase 13.2 kV Solid State Transformer for the DC Distribution)

  • 정동근;윤혁진;박시호;김호성;김명호;류명효;백주원
    • 전력전자학회논문지
    • /
    • 제26권5호
    • /
    • pp.315-324
    • /
    • 2021
  • A solid state transformer (SST) that can interface an MVAC of three-phase 13.2 kV and a 1.5 kV DC distribution. SST consists of an AC/DC converter and a DC/DC converter with a high-frequency isolation transformer (HFIT). The AC/DC converter consists of cascaded NPC full-bridge to cope with the MVAC. The DC/DC converter applies a quad active bridge (QAB) topology to reduce the number of the HFIT. Topology analysis and controller design for this specific structure are discussed. In addition, the insulation of HFIT used in DC/DC converters is considered. The discussion is validated using a 300 kVA three-phase SST prototype.

Minimization of DC-Link Capacitance for NPC Three-level PWM Converters

  • Alemi, Payam;Lee, Dong-Choon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.370-371
    • /
    • 2011
  • This paper presents a control algorithm that minimizes the DC-link capacitance by decreasing the capacitor current. The capacitor current can be nullified by a feedback compensation term which is calculated from the power balance in the AC/DC converter. As a result, voltage variation in the DC-link is reduced further, which makes a large reduction in the size of DC-link capacitors which are expensive and have limitations in life time. Simulations are performed with two 80uF DC-link capacitors, which can be replaced by film capacitors.

  • PDF

단상 3-레벨 PWM 컨버터를 위한 중성점 전압 변동 보상 기법 (DC-link Voltage Ripple Compensation Method for Single Phase 3-level PWM Converters)

  • 이희면;이동명
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.8-15
    • /
    • 2013
  • This paper proposes a DC-link voltage variation compensation method for a 3-level single phase converter for high-speed trains. Since 3-level NPC(Neutral Point Clamped) type converters have the split DC-link causing the inherent problem of voltage fluctuations in the upper and lower capacitors, reducing the voltage difference between the top and bottom capacitors is required. In this paper, compensation time proportional to the voltage difference is added to PWM switching time to solve the voltage variation. The compensation time is obtained by a PI controller. Simulation results demonstrate the validity of the proposed method.

Active NPC를 적용한 계통연계형 해상 풍력 발전용 전력변환 시스템 (Grid-Connected Off-Shore Wind Power System Using 3-Level ANPC VSC (Active Neutral-Point-Clamped Voltage Source Converter))

  • 홍석진;신수철;이희준;최치환;원충연;김학성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.249-250
    • /
    • 2012
  • 해상 풍력 발전은 가장 유망한 재생 에너지원의 하나이며, 육상 풍력 발전보다 풍력이 강력하고 일정하여 장시간 고출력 발생이 가능하다. 또한 소음, 공간적 한계, 경관훼손 등 기존 육상 풍력 발전의 단점을 보완하고 초대형 단지조성이 가능한 장점이 있다. 초대형 해상풍력단지에는 일반적으로 MW급의 해상풍력발전기가 사용된다. 본 논문에서는 MW급의 해상 풍력발전기에 ANPC(Active Neutral-Point-Clamped) Multi-Level VSC(Voltage Source Converter)를 적용하여 Back-to-Back으로 구성한 시스템을 제안하고 계통연계형 풍력 발전 시스템을 모의한 시뮬레이션을 통하여 제안된 시스템의 성능을 검증한다.

  • PDF

Finite State Model-based Predictive Current Control with Two-step Horizon for Four-leg NPC Converters

  • Yaramasu, Venkata;Rivera, Marco;Narimani, Mehdi;Wu, Bin;Rodriguez, Jose
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1178-1188
    • /
    • 2014
  • This study proposes a finite-state model predictive controller to regulate the load current and balance the DC-link capacitor voltages of a four-leg neutral-point-clamped converter. The discrete-time model of the converter, DC-link, inductive filter, and load is used to predict the future behavior of the load currents and the DC-link capacitor voltages for all possible switching states. The switching state that minimizes the cost function is selected and directly applied to the converter. The cost function is defined to minimize the error between the predicted load currents and their references, as well as to balance the DC-link capacitor voltages. Moreover, the current regulation performance is improved by using a two-step prediction horizon. The feasibility of the proposed predictive control scheme for different references and loads is verified through real-time implementation on the basis of dSPACEDS1103.

Loss Analysis and Comparison of High Power Semiconductor Devices in 5MW PMSG MV Wind Turbine Systems

  • Lee, Kihyun;Suh, Yongsug;Kang, Yongcheol
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1380-1391
    • /
    • 2015
  • This paper provides a loss analysis and comparison of high power semiconductor devices in 5MW Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) Wind Turbine Systems (WTSs). High power semiconductor devices of the press-pack type IGCT, module type IGBT, press-pack type IGBT, and press-pack type IEGT of both 4.5kV and 6.5kV are considered in this paper. Benchmarking is performed based on the back-to-back type 3-level Neutral Point Clamped Voltage Source Converters (3L-NPC VSCs) supplied from a grid voltage of 4160V. The feasible number of semiconductor devices in parallel is designed through a loss analysis considering both the conduction and switching losses under the operating conditions of 5MW PMSG wind turbines, particularly for application in offshore wind farms. This paper investigates the loss analysis and thermal performance of 5MW 3L-NPC wind power inverters under the operating conditions of various power factors. The loss analysis and thermal analysis are confirmed through PLECS Blockset simulations with Matlab Simulink. The comparison results show that the press-pack type IGCT has the highest efficiency including the snubber loss factor.

Theoretical Analysis and Control of DC Neutral-point Voltage Balance of Three-level Inverters in Active Power Filters

  • He, Yingjie;Liu, Jinjun;Tang, Jian;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • 제12권2호
    • /
    • pp.344-356
    • /
    • 2012
  • In recent years, multilevel technology has become an effective and practical solution in the field of moderate and high voltage applications. This paper discusses an APF with a three-level NPC inverter. Obviously, the application of such converter to APFs is hindered by the problem of the voltage unbalance of DC capacitors, which leads to system instability. This paper comprehensively analyzes the theoretical limitations of the neutral-point voltage balancing problem for tracking different harmonic currents utilizing current switching functions from the space vector PWM (SVPWM) point of view. The fluctuation of the neutral point caused by the load currents of certain order harmonic frequency is reported and quantified. Furthermore, this paper presents a close-loop digital control algorithm of the DC voltage for this APF. A PI controller regulates the DC voltage in the outer-loop controller. In the current-loop controller, this paper proposes a simple neutral-point voltage control method. The neutral-point voltage imbalance is restrained by selecting small vectors that will move the neutral-point voltage in the direction opposite the direction of the unbalance. The experiment results illustrate that the performance of the proposed approach is satisfactory.

NPC 3-레벨 PWM 인버터에서 고장 발생에 따른 고장 진단과 중성점 전압 제어 (Fault Diagnosis and Neutral-Point Voltage Control according to Faults for a Three-level Neutral-Point-Clamped PWM Inverter)

  • 손호인;김태진;강대욱;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.11-16
    • /
    • 2003
  • The 3-level converter/inverter system is very efficient in the ac motor drives of high voltage and high power application. This paper proposed a simple method to diagnose faults using change of current vector pattern in space vector diagram when the faults occurrence in the 3-level inverter and a control method that can protect system from unbalance of the neutral point voltage according to faults. The validity of the proposed method is demonstrated by the simulation results.

  • PDF

Characteristics of High Power Semiconductor Device Losses in 5MW class PMSG MV Wind Turbines

  • Kwon, Gookmin;Lee, Kihyun;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.367-368
    • /
    • 2014
  • This paper investigates characteristics of high power semiconductor device losses in 5MW-class Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) wind turbines. High power semiconductor device of press-pack type IGCT of 6.5kV is considered in this paper. Analysis is performed based on neutral point clamped (NPC) 3-level back-to-back type voltage source converter (VSC) supplied from grid voltage of 4160V. This paper describes total loss distribution at worst case under inverter and rectifier operating mode for the power semiconductor switches. The loss analysis is confirmed through PLECS simulations. In addition, the loss factors due to di/dt snubber and ac input filter are presented. The investigation result shows that IGCT type semiconductor devices generate the total efficiency of 97.74% under the rated condition.

  • PDF

Flyback-type Snubber of High Efficiency for 10kV IGCT in 7MW Wind Turbine Systems

  • Shirmohammadi, Siamak;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.359-360
    • /
    • 2015
  • 10kV IGCT has been recently developed and has the potential to push wind turbine systems to higher power and voltage rating. Converters employing IGCTs need snubber and OVP circuit to limit the rate of rise of current and peak over voltage across IGCT during turn on and off state respectively. The conventional RCD snubber which is used in such power converter dissipates a significant amount of power. In order to reduce the amount of energy lost by conventional RCD snubber, this paper proposes an isolated inductor snubber circuit that not only meets all of the IGCTs characteristics during on and off-state but also significantly saves the power loss. Loss analysis of conventional di/dt snubber and OVP circuit is performed for the 3-level NPC type back-to-back VSC supplied from grid voltage of 6.9kV. In comparison with the conventional snubber, isolated inductor snubber has a fewer number of components and improved efficiency leading to a reliable and efficient wind turbine systems.

  • PDF