• Title/Summary/Keyword: NO determination

Search Result 1,445, Processing Time 0.032 seconds

A Determination of the Reference Model for the Model Following System using an Expert System (전문가 시스템을 이용한 모델 추종 시스템의 기준 모델 선정)

  • Moon, Dong-Wook;Hwang, Young-Moon;Kang, Young-Ho;Lee, Hoo-Min;Kim, Lark-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1069-1072
    • /
    • 1996
  • In modern control engineering, the model following system is a typical method. The model following system's performance is due to algorithm of control law, accuracy of modeling to the plant, and dynamics of the reference model. But the determination of the reference model depends on knowledge of an expert. Using an expert system, the determination method of the reference model was proposed in this paper. So, the reference model can be selected by user who has no Knowledge of dynamics and parameters.

  • PDF

Studies on the Differential Determination of cis-, and trans-Neopynamin and Fenitrothion by High Pressure Liguid Chromatography (고속 액체 크로마토그라피에 의한 cis- 및 trans-Neopynamin과 Fenitrothion의 분리 정량에 관한 연구)

  • 이왕규;정해수
    • YAKHAK HOEJI
    • /
    • v.24 no.2
    • /
    • pp.117-122
    • /
    • 1980
  • A new application of high pressure liquid chromatography for the determination of fenitrothion and cis- and trans-neopynamin in insecticidal preparations was investigated. Optimum conditions for a good separation and determination were determined; solvent system: dichloromethane + n-hexane = 17 + 83; Bow rate: 0.5ml/min; column: u-porasil ($4mm{\times}3Ocm$); absorbance wavelength: 254nm; 0.05 AUFS and sample size: 30 ul. Recovery of fenicrothion, cis- and trans-neopynamin from mixed artificial preparations was 99.6%, 99.7% and 99.8% respectively. Also reproducibility tests showed that the coefficient of variation was 0.89% for fenitrothion, 0.74% cis-neopynamin and 1.1% for trans-neopynamin. There was no interference with insecticidal preparation containing DDVP, allethrin, S-421 and kerosene. HPLC method was rapid, accurate and it gave better reproducibility and higher sensitivity than any other analytical method. It was considered that HPLC could be greatly applied to the analysis of fenitrothion and neopynamin in insecticidal preparations.

  • PDF

H0 Determination Using TRGB Distances to the Virgo Infalling Galaxies

  • Kim, Yoo Jung;Kang, Jisu;Lee, Myung Gyoon;Jang, In Sung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.32.1-32.1
    • /
    • 2020
  • An independent determination of H0 is crucial given the growing tension of the Hubble constant (H0). In this work, we present a new determination of H0 using velocities and Tip of the Red Giant Branch (TRGB) distances to 33 galaxies in front of the Virgo Cluster. We model the infall pattern of the local Hubble flow modified by the Virgo mass, as a function of the H0, the radius of the zero-velocity surface R0, and the intrinsic velocity scatter. Fitting velocities and TRGB distances of 33 galaxies to the model, we obtain H0 = 65.6 +/- 3.4 (stat) +/- 1.0 (sys) km/s/Mpc and R0 = 6.96 +/- 0.35 Mpc. Our local H0 is consistent with the global H0 determined from cosmic microwave background radiation, showing no tension.

  • PDF