• 제목/요약/키워드: NO Emission

검색결과 1,801건 처리시간 0.03초

Development and Evaluation of Natural Hydroxyapatite Ceramics Produced by the Heat Treatment of Pig Bones

  • Lim, Ki-Taek;Kim, Jin-Woo;Kim, Jangho;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • 제39권3호
    • /
    • pp.227-234
    • /
    • 2014
  • Purpose: The aim of this research was to develop and evaluate natural hydroxyapatite (HA) ceramics produced from the heat treatment of pig bones. Methods: The properties of natural HA ceramics produced from pig bones were assessed in two parts. Firstly, the raw materials were characterized. A temperature of $1,200^{\circ}C$ was chosen as the calcination temperature. Fine bone powders (BPs) were produced via calcinations and a milling process. Sintered BPs were then characterized using field emission scanning electron microscopy (FE-SEM), X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), energy dispersive X-ray spectroscopy (EDX), Fourier transform infrared (FTIR) spectroscopy, and a 2-year in vitro degradability test. Secondly, an indirect cytotoxicity test was conducted on human osteoblast-like cells, MG63, treated with the BPs. Results: The average particle size of the BPs was $20{\pm}5{\mu}m$. FE-SEM showed a non-uniform distribution of the particle size. The phase obtained from XRD analysis confirmed the structure of HA. Elemental analysis using XRF detected phosphorus (P) and calcium (Ca) with the Ca/P ratio of 1.6. Functional groups examined by FTIR detected phosphate ($PO{_4}^{3-}$), hydroxyl ($OH^-$), and carbonate ($CO{_3}^{2-}$). The EDX, XRF, and FTIR analysis of BPs indicated the absence of organic compounds, which were completely removed after annealing at $1,200^{\circ}C$. The BPs were mostly stable in a simulated body fluid (SBF) solution for 2 years. An indirect cytotoxicity test on natural HA ceramics showed no threat to the cells. Conclusions: In conclusion, the sintering temperature of $1,200^{\circ}C$ affected the microstructure, phase, and biological characteristics of natural HA ceramics consisting of calcium phosphate. The Ca-P-based natural ceramics are bioactive materials with good biocompatibility; our results indicate that the prepared HA ceramics have great potential for agricultural and biological applications.

In-111-Antimyosin 항체를 이용한 심근경색의 정량적 평가 (Quantitative Assessment of Myocardial Infarction by In-111 Antimyosin Antibody)

  • 이명철;이경한;최윤호;정준기;박영배;고창순;문대혁
    • 대한핵의학회지
    • /
    • 제25권1호
    • /
    • pp.37-45
    • /
    • 1991
  • Infarct size is a major determinant of prognosis after acute myocardial infarction. Up to date, however, clinically available tests to estimate this size have not been sufficiently accurate. Twelve lead electrocardiogram and wall motion abnormality measurement are not quantitative, and creatine phophokinase (CPK) measurement is inaccurate in the presence of reperfusion or right ventricular infarction. Methods have been developed to localize and size acute myocardial infarcts with agents that are selectively sequestered in areas of myocardial damage, but previously used agents have lacked sufficient specificity. Antibodies that bind specifically only to damaged myocardial cells may resolve this problem and provide an accurate method for noninvasively measuring infarct size. We determined the accuracy with which infarcted myocardial mass can be measured using single photon emission computed tomography (SPECT) and radiolabeled antimyosin antibodies. Seven patients with acute myocardial infarction and one stable angina patient were injected with 2 mCi of Indium-111 labeled antimyosin antibodies. Planar image and SPECT was performed 24 hours later. None of the patients had history of prior infarcts, and none had undergone reperfusion techniques prior to the study, which was done within 4 days of the attack. Planar image showed all infarct patients to have postive uptakes in the cardiac region. The location of this uptake correlated to the infarct site as indicated by electrocardiography in most of the cases. The angina patient, however, showed no such abnormal uptake. Infarct size was determined from transverse slices of the SPECT image using a 45% threshold value obtained from a phantom study. Measured infarct size ranged from 40 to 192 gr. There was significant correlation between the infarct size measured by SPECT and that estimated from serial measurements of CPK (r=0.73, p<0.05). These date suggest that acute myocardial infarct size can be accurately measured from SPECT Indium-111 antimyosin imaging. This method may be especially valuable in situations where other methods are unreliable, such as early reperfusion technique, right ventricular infarct or presence of prior infarcts.

  • PDF

정신분열병 환자의 임상적 증세 호전에 따른 $^{99m}Tc$-HMPAO 뇌 SPECT 소견의 변화 (Effect of Clinical Improvement of Schizophrenic Symptoms on $^{99m}Tc$-HMPAO Brain SPECT)

  • 신철진;궁성수;정인원
    • 대한핵의학회지
    • /
    • 제31권3호
    • /
    • pp.310-319
    • /
    • 1997
  • 본 연구는 정신분열병 환자의 치료후의 국소뇌혈류량의 변화 및 증상호전과의 관계를 알아보기 위하여 시행되었다. DSM-IV 진단기준에 의거한 총 11명의 정신분열병 환자를 대상으로 치료전과 치료 6주째에 $^{99m}Tc$-HMPAO 뇌 SPECT를 실시하였으며 동시에 PANSS를 사용하여 정신병리를 함께 평가하였다. 대상자들은 입원전 최소 2주간의 항정신병 약물 비복용기간을 거친 환자들이었으며 이중 3명은 과거 항정신병약물의 복용력이 없는 사람들이었다. 6주간의 약물 치료훼 환자들은 증상의 호전 정도에 따라 호전군과 비호전군으로 나누어졌으며 이들간의 뇌국소혈류지수를 비교하였다. 결과적으로 전두엽의 혈류지수는 양집단 모두에서 감소하였고 집단간의 차이는 없었다. 그러나 조측 측두엽의 혈류량은 호전군에서 유의하게 많이 감소하였고 또한 우측 측두엽의 혈류량의 감소량은 PANSS 총점의 감소량과 상관관계를 나타내었다. 이러한 결과는 정신분열병의 증상과 측두엽의 활동성간의 관계를 시사하는 소견이라고 하겠다.

  • PDF

Pulsed DC $BCl_3/SF_6$ 플라즈마를 이용한 GaAs와 AlGaAs의 선택적 식각에 관한 연구

  • 최경훈;김진우;노강현;신주용;박동균;송한정;이제원
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.67-67
    • /
    • 2011
  • Pulsed DC $BCl_3/SF_6$ 플라즈마를 사용하여 GaAs와 AlGaAs의 건식 식각을 연구하였다. 식각 공정 변수는 가스 유량 (50~100 % $BCl_3$ in $BCl_3/SF_6$), 펄스 파워 (450~600 V), 펄스 주파수 (100~250 KHz), 리버스 시간 (0.4~1.2 ${\mu}s$)이었다. 식각 공정 후 표면 단차 측정기 (Surface profiler)를 사용하여 표면의 단차와 거칠기를 분석하였다. 그 결과를 이용하여 식각률 (Etch rate), 표면거칠기 (Surface roughness), 식각 선택비 (Selectivity)와 같은 특성 평가를 하였다. 실험 후 주사 현미경 (FE-SEM, Field Emission Scanning Electron Microscopy)을 이용, 식각 후 시료의 단면과 표면을 관찰하였다. 실험 결과에 의하면 1) 18 sccm $BCl_3$ / 2 sccm $SF_6$, 500 V (Pulsed DC voltage), 0.7 ${\mu}s$ (Reverse time), 200 KHz (Pulsed DC frequency), 공정 압력이 100 mTorr인 조건에서 GaAs와 Al0.2Ga0.8As의 식각 선택비가 약 48:1로 우수한 결과를 나타내었다. 2) 펄스 파워 (Pulsed DC voltage), 리버스 시간(Reverse time), 펄스 주파수(Pulsed DC frequency)의 증가에 따라 각각 500~550 V, 0.7~1.0 ${\mu}s$, 그리고 200~250 KHz 구간에서 AlGaAs에 대한 GaAs의 선택비가 감소하게 되는 것을 알 수 있었다. 이는 척 (chuck)에 인가되는 전류와 파워를 증가시키고, 따라서 GaAs의 식각률이 크게 증가했지만 AlGaAs 또한 식각률이 증가하게 되면서 GaAs에 대한 식각 선택비가 감소한 것으로 생각된다. 3) 표면 단차 측정기와 주사전자현미경 사진 결과에서는 GaAs의 경우 10% $SF_6$ (18 sccm $BCl_3$ / 2 sccm $SF_6$)가 혼합된 조건에서 상당히 매끈한 표면 (RMS roughness < 1.0 nm)과 높은 식각률 (~0.35 ${\mu}m$/min), 수직의 식각 측벽 확보에서 매우 좋은 결과를 보여주었다. 또한 같은 공정 조건에서 AlGaAs는 식각이 거의 되지 않은 결과 (~0.03 ${\mu}m$/min)를 보여주었다. 위의 결과들을 종합해 볼 때 Pulsed DC $BCl_3/SF_6$ 플라즈마는 GaAs와 AlGaAs의 선택적 식각 공정에서 매우 우수한 공정 결과를 나타내었다.

  • PDF

몽골산 크롬철광 중의 금속성분 분석 (Determination of Metal Elements in Mongolian Chromite)

  • 최광순;이창헌;표형렬;박순달;조기수
    • 분석과학
    • /
    • 제13권6호
    • /
    • pp.766-774
    • /
    • 2000
  • 유도결합 플라스마 원자방출분광법(ICP-AES)을 이용하여 몽골산 크롬철광의 성분을 분석하였다. 크롬철광을 용해시키기 위하여 과염소산-인산의 흔합산과 융제로서 $Na_2O_2$의 적용성을 검토한 결과 최적의 용해방법은 용융법이었다. 크롬광의 주성분과 미량성분을 ICP-AES로 정량할 때 과량의 Na가 측정파장에 미치는 영향을 조사하였다. Al, Cr, Fe 및 Mg과 같은 주성분원소의 경우 Na가 250 mg/L까지 영향을 받지 않았으나, Co, Ni, Ti, V 및 Zn과 같은 미량성분들은 Na가 1,250 mg/L인 경우 측정원소와 파장에 따라 방출선의 세기는 1-5% 정도 감소하였다. 본 방법의 정확도를 확인하기 위하여 중성자방사화분석으로 얻은 결과와 상대편차를 비교하였다. $Al_2O_3$, $Cr_2O_3$, FeO 및 MgO의 경우에는 FeO를 제외하고 상대편차가 5% 이내이며, Co, Mn, V 및 Zn의 경우에는 ~20-8% 범위였다.

  • PDF

경부절제술과 술후 시행된 PET/CT상의 흉쇄관절 섭취 증가의 상관관계 분석 (A correlation between comprehensive neck dissection and increased uptake around the sternoclavicular joint on post-operative 18F-FDG PET/CT)

  • 오소원;이도영;김보해;김광현;김유경;정영호
    • 대한두경부종양학회지
    • /
    • 제34권1호
    • /
    • pp.21-27
    • /
    • 2018
  • Background/Objectives: This study aimed to evaluate the changes of uptake around the sternoclavicular joint (SCJ) according to 18F-FDG PET images in patients with head and neck cancer who underwent neck dissection. Materials & Methods: Retrospectively, the medical records of patients who received selective or comprehensive neck dissection were reviewed. Preoperative and 1-year postoperative 18F-FDG PET images, if available, were analyzed by nuclear medicine physicians in both qualitative and quantitative manners. Correlation between the changes of uptake around SCJ and perioperative data were statistically analyzed. Results: Thirty-seven patients satisfying the inclusion criteria were enrolled. Seven patients with increased uptake around SCJ on 1-year postoperative 18F-FDG PET showed a correlation with radical or comprehensive neck dissection, accessory nerve sacrifice, and high postoperative SUVmax. When 20 patients with increased uptake around SCJ according to quantitative measurement were compared with other patients without increased uptake, no parameter was significantly different, except postoperative SUVmax. Bivariate logistic regression analysis revealed that the clinical symptom (shoulder or sternal pain) was significantly correlated with the extent of neck dissection (OR 0.227, CI 0.053-0.966, p=0.045) and spinal accessory nerve sacrifice (OR 13.500, CI 1.189-153.331, p=0.036). Conclusions: Increased uptake around SCJ on 1-year postoperative 18 F-FDG PET was correlated with either the radical or comprehensive procedure, as well as with accessory nerve sacrifice. This suggests that subjective analysis of 18F-FDG PET can be used to detect subclinical shoulder instability.

SURFACE CHARACTERISTICS OF ANODIC OXIDIZED TITANIUM ACCORDING TO THE PORE SIZE

  • Ha Heon-Seok;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.343-355
    • /
    • 2006
  • Statement of problem. The success of osseointegration can be enhanced with an implant that has improved surface characteristics. Anodic oxidation is one of the surface modifying method to achieve osseointegration. Voltage of anodic oxidation can change surface characteristics and cell activity Purpose. This study was performed to evaluate MG63 cell responses such as affinity, proliferation and to compare surface characteristics of anodic oxidized titanium in various voltage. Material and method. The disks for cell culture were fabricated from grade 3 commercially pure titanium,1 m in thickness and 12 mm in diameter. Surfaces of 4 different roughness were prepared. Group 1 had a machined surface, used as control. Group 2 was anodized under 220 V, group 3 was anodized under 300 V and group 4 was anodized under 320 V. The microtopography of specimens was observed by scanning electron microscope (JSM-840A, JEOL, Japan) and atomic force microscope(Autoprobe CP, Park Scientific Instrument, USA). The surface roughness was measured by confocal laser scanning microscope(Pascal, LSM5, Zeiss, Germany). The crystal structure of the titanium surface was analyzed with x-ray diffractometer(D8 advanced, Broker, Germany). MG63 osteoblast-like cells were cultured on these specimens. The cell morpholgy was observed by field emission electron microscope(Hitachi S-4700, Japan). The cell metabolic and proliferative activity was evaluated by MTT assay Results and conclusion. With in limitations of this in vitro study, the following conclusions were drawn. 1. In anodizing titanium surface, we could see pores which did not show in control group. In higher anodizing voltage, pore size was increased. 2. In anodizing titanium surface, we could see anatase. In higher anodizing voltage, thicker oxide layer increased crystallinity(anatase, anatase and rutile mixed). 3. MG63 cells showed more irregular, polarized and polygonal shape and developed more lamellipodi in anodizing group as voltage increased. 4. The activity of cells in MTT assay increased significantly in group 3 and 4 in comparison with group 1 and 2. However, there was no difference between group 3 and 4 at P<0.05. Proliferation of MG63 cells increased significantly in pore size($3-5.5{\mu}m$) of group 3 and 4 in comparison with in pore size($0.2-1{\mu}m$ ) of group 2.

타이타늄 합금에 다양한 두께로 코팅된 TiN 피막의 기계적 성질 (MECHANICAL PROPERTIES OF TIN COATED FILM WITH VARIOUS COATING THICKNESS ON TITANIUM ALLOY)

  • 이재윤;오동준;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.675-686
    • /
    • 2007
  • Statement of problem: Titanium nitride(TiN) coatings are the most general and popular coating method and used to improve the properties of metallic surface for industrial purposes. When TiN coating applied to the abutment screw, frictional resistance would be reduced, as a results, the greater preload and prevention of the screw loosening could be expected. Purpose: The purpose of this study was to investigate mechanical properties of TiN coated film of various coating thickness on the titanium alloy surface and to evaluate proper coating thickness. Material and method: 95 Titanium alloy (Ti-6Al-4V) discs of 15 mm in diameter and 3 mm in thickness were prepared for TiN coating and divided into 7 groups in this study. Acceding to coating deposition time (CDT) with TiN by using Arc ion plating, were divided into 7 groups : Group A (CDT 30min), Group B (CDT 60min), Group C (CDT 90min), Group D (CDT 120min), Group E (CDT 150min), Group F(CDT 180min) and Group G (no CDT) as a control group. TiN coating surface was observed with Atomic Force Microscope(AFM), field emission scanning electron microscopy(FE-SEM) and examined with scratch tester, wear tester. Result: 1. Coating thickness fir each coated group was increased in proportion to coating deposition time. 2. Surface of all coated groups except Group A was homogeneous and smooth. However, surface of none coated Group G had scratch. 3. Adhesion strength for each coated group was increased in proportion to coating deposition time. 4. Wear resistance for each coated group was increased in proportion to coating deposition time. 5. Surface roughness in Group A, B, C was increased in proportion to coating deposition time. But, surface roughness in Group D, E, F was showed decreased tendency in proportion to coating deposition time. Conclusion: According to coating deposition time, mechanical properties of TiN coated film were changed. It was considered that 120 minutes coating deposition time ($1.32{\mu}m$ in coating thickness) is necessary.

수소 가스 원격 모니터링을 위한 라만 라이다 시스템 개발 (Development of a Raman Lidar System for Remote Monitoring of Hydrogen Gas)

  • 최인영;백성훈;박락규;강희영;김진호;이나종
    • 한국광학회지
    • /
    • 제28권4호
    • /
    • pp.166-171
    • /
    • 2017
  • 수소 가스는 연소과정에서 오염물질의 배출이 없는 친환경 에너지원이다. 그러나 연소 및 폭발성이 매우 강해 매우 위험한 특징을 갖고 있다. 원자력 발전소의 중대 사고 발생시 핵연료의 산화 과정에서 다량의 수소 가스가 발생하며 원전 격납 건물의 2차 사고의 원인으로 작용함으로 원전의 안전을 확보하기 위하여 수소 가스의 검출 기술은 매우 중요하다. 본 논문은 수소 가스의 원격 계측을 위한 라만 라이다 시스템의 개발에 관한 것이다. 소형의 이동 가능한 라만 라이다 시스템을 설계 및 개발하였으며, 수소 가스의 농도를 정량적으로 계측하기 위한 계측 알고리즘을 개발하였다. 개발된 수소 가스 계측을 위한 라만 라이다 시스템의 수소 가스 검출 능력을 검증하기 위하여 수소 가스의 농도를 조절할 수 있는 가스 챔버를 이용하여 낮에 야외 환경에서 수소 가스 검출 실험을 실시하였다. 그 결과 20미터 거리에서 최소 0.67 Vol.%의 수소 가스 농도의 검출이 가능하였다.

산화은/이산화티타늄 혼합물을 광촉매로 활용한 물/메탄올 분해 수소제조 (Hydrogen Production from Photocatalytic Splitting of Water/Methanol Solution over a Mixture of P25-TiO2 and AgxO)

  • 김강민;정경미;박노국;이태진;강미숙
    • 청정기술
    • /
    • 제21권4호
    • /
    • pp.271-277
    • /
    • 2015
  • 본 연구에서는 효율적인 광 전기화학적 수소제조를 위하여 광촉매로써 상용화 촉매인 P25-티타니아와 합성한 AgxO를 적정 질량비로 혼합한 촉매를 사용하였다. AgxO는 일반적인 솔-젤법으로 합성하였으며, 은 용액의 안정화를 위해 합성과정 중에 수산화테트라메틸암모늄을 첨가하고 열처리 온도를 -5, 25, 50 ℃로 다양화시켜 세 가지 형태의 산화은을 얻었다. 합성한 AgxO의 물리화학적 특성은 X-선 회절분석법(XRD), 주사전자현미경(SEM), 자외선-가시선 분광광도계(UV-Visible spectroscopy), X-선 광전자 분광법(XPS)을 이용하여 확인하였다. 물/메탄올(무게 비 1:1) 혼합용액을 광분해 한 결과, 순수 P25-티타니아보다 AgxO가 첨가된 혼합촉매에서 현저히 높은 양의 수소가 발생하였다. 보조 산화제로써 H2O2를 첨가한 경우 그리고 AgxO의 합성온도가 50 ℃일 때 가장 높은 수소 제조효율을 나타내었다. 특히, 0.9 g의 P25-티타니아와 0.1 g의 AgxO (50 ℃)를 혼합한 촉매를 사용하였을 때 8시간 반응하는 동안에 13,000 μmol의 수소가 발생하였다.