• 제목/요약/키워드: NIST reference beam

검색결과 5건 처리시간 0.015초

Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

Standardization of Fracture Toughness Testing of Ceramics in the United States

  • Quinn, G.D.;Jenkins, M.J.;Salem, J.;Bar-On, I.
    • The Korean Journal of Ceramics
    • /
    • 제4권4호
    • /
    • pp.311-322
    • /
    • 1998
  • American Society for Testing and Materials (ASTM) standard test method PS 070-97 has been created for measuring fracture toughness of advanced ceramics. PS 070-97 includes three test methods which use beams in bending: chevron notch (CNB), single-edged precracked beam (SEPB), and surface crack in flexure (SCF). Supporting data has been collected through several Versailles Advanced Materials and Standards round robins. This paper discusses the evolution of the standard including the rationale for the choice of the three methods and the specifications in the standard. Progress on Standard Reference material 2100 which will have certified values of fracture toughness is presented.

  • PDF

몬테칼로 시뮬레이션을 활용한 양성자가속기 단기사용 시 구성품의 방사화 평가 (A Study on the Radioactive Products of Components in Proton Accelerator on Short Term Usage Using Computed Simulation)

  • 배상일;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.389-395
    • /
    • 2020
  • The evaluation of radioactivated components of heavy-ion accelerator facilities affects the safety of radiation management and the exposure dose for workers. and this is an important issue when predicting the disposal cost of waste during maintenance and dismantling of accelerator facilities. In this study, the FLUKA code was used to simulate the proton treatment device nozzle and classify the radio-nuclides and total radioactivity generated by each component over a short period of time. The source term was evaluated using NIST reference beam data, and the neutron flux generated for each component was calculated using the evaluated beam data. Radioactive isotopes caused by generated neutrons were compared and evaluated using nuclide information from the International Radiation Protection Association and the Korea Radioisotope association. Most of the nuclides produced form of beta rays and electron capture, and short-lived nuclides dominated. However, In the case of 54Mn, which is a radioactive product of iron, the effect of gamma rays should be considered. In the case of tritium generated from a material with a low atomic number, it is considered that handling care should be taken due to its long half-life.

하나로의 즉발감마선 방사화분석 장치를 이용한 붕소의 정량에 대한 연구 (Study on Determination of Boron using the PGAA Facility at HANARO Research Reactor)

  • 정용삼;조현제;문종화;김선하;김영진
    • 분석과학
    • /
    • 제16권5호
    • /
    • pp.391-398
    • /
    • 2003
  • 하나로의 즉발감마선 방사화분석 장치를 이용하여 생물시료중의 붕소의 정량을 위한 기초연구를 수행하였다. 측정조건에 대한 특성조사를 위해 시료에 대한 중성자 조사 위치에서 중성자속 및 균질도를 측정하였다. 시료위치에서 열중성자 빔의 크기가 $2{\times}2cm^2$ 되도록 집속하였으며, 측정된 선속은 $1.0{\sim}6.5{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$ 범위를 나타냈으며, 중심부로부터 반경 4.5 mm 이내 및 9 mm 이내에서 각각 $5.77{\pm}0.71{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$, $4.68{\pm}1.64{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$이었다. 따라서 양질의 균일한 조사를 위해서 시료의 크기를 10 mm 이내로 조정하였다. 검출 시스템은 컴프턴 산란에 의한 백그라운드 요인을 억제하고 분석감도를 높이기 위해 설계되었으며, 감마선 계측 시스템의 에너지 교정과 컴프턴 억제율을 조사하기 위해 NaCl 표준체를 이용하여 단일 및 컴프턴 모드로 백그라운드를 측정하였다. 또한 정확한 붕소의 측정을 위해 시료의 매질효과로서 발생하는 분광학적 Na의 472 keV 피이크에 대한 간섭효과를 결정하였으며, 세 가지 인증표준물질 (NIST SRM 1570a, 1547, 1573a)을 이용한 붕소농도 측정시험을 두 가지 모드로 실시한 후 결과를 비교하였다.

개인선량 평가의 성능검증을 위한 기준급 감마선장의 특성 평가 (Evaluation of Characteristics in the Reference Gamma Radiation Fields for testing of Personnel Dosimetry Performance)

  • 오장전;조대형;한승재;나성호;이두희;이병수;전재식;채하석;이철영
    • Journal of Radiation Protection and Research
    • /
    • 제23권4호
    • /
    • pp.229-236
    • /
    • 1998
  • 개인 피폭선량 평가의 검증체계를 확립함에 있어서 기본적으로 갖추어야할 방사선장은 감마선, X-선, 베타선 및 중성자이다 금년에 한국원자력안전기술원에서는 중성자를 제외한 방사선장을 위한 기준조사장치(빔)를 확보하였다. 이 기준조사빔이 국제적으로 소급할 수 있는 방사선장의 역할을 수행할 수 있도록 하기 위하여 국제 표준기구규정 및 선진국의 표준규격 등의 기준과 요구조건에 충족되도록 하였다. 본 논문은 감마선장에 대한 기준조사장치에 관한 것으로서의 기여도 및 방사선장의 균질도를 평가하였고, 이를 국제 기준과 비교한 결과 국내 및 국제 기준을 잘 만족하고 있는 것으로 평가되었다. 또한, 측정된 공기커마율은 $^{137}Cs$ 선원에 대하여 $0.1891{\sim}23.4967{\mu}Gy/s$, $^{60}Co$ 선원에 대해서는 $0.588{\sim}15.9954{\mu}$Gy/s의 값으로 결정하였으며, 공기커마율이 가지는 불확도는 95% 신뢰도 범위에서 2.5% 이내로 결정되었다. 측정된 공기커마율의 신뢰성을 검증하기 위하여 전리함의 교정정수를 독일 PTB의 교정정수에 대하여 재평가한 결과 교정정수가 가지는 불착도(1.2%) 범위 내에서 일치하고 있었으며, 미국의 측정값과 비교한 결과 0.03% 범위 내에서 일치하고 있음이 판명되었다. 그러므로 한국원자력안전기술원에 설치된 감마선장은 국내의 표준 소급체계를 유지하고 있을 뿐만 아니라 미국 및 독일의 소급체계를 확보하게 되었고, 국내 및 국제 기준 방사선장으로 활용 가능하게 되었다.