• 제목/요약/키워드: NIRS

검색결과 269건 처리시간 0.025초

식품의 원산지 판별분석 (Discrimination Analysis of the Geographical Origin of Foods)

  • 최진영;방경환;한기영;노봉수
    • 한국식품과학회지
    • /
    • 제44권5호
    • /
    • pp.503-525
    • /
    • 2012
  • Consumers are increasingly concerned about the origin of foods, so the geographical origin of foods has been a major topic of debate and extensive research. Various instrumental methods (e.g. high performance liquid chromatography (HPLC), gas chromatography (GC), capillary electrophoresis (CE), electronic nose, near-infrared spectroscopy (NIRS), nuclear magnetic resonance spectroscopy (NMR), DNA analysis, multi-isotope analysis) in conjunction with statistical analysis, were developed and applied in attempt to provide reliable answers to their geographical origin. This study reviews current developments in the application of various methods for a clear geographical origin of foods. The limitation of discrimination analysis for geographical origin was also discussed.

Measurement of Spray Deposit Amount Using Spectrophotometer and Food Dye as Tracer

  • Rhee, J.Y.;Ahn, S.Y.
    • Agricultural and Biosystems Engineering
    • /
    • 제1권1호
    • /
    • pp.16-21
    • /
    • 2000
  • Measurement of spray deposit is necessary for evaluation of a chemical application technology. However it is not easy and time consuming. A simple method for measuring the deposition amount of spray using a tracer and a spectrophotometer was developed. Various materials were tested to determine an adequate tracer. Food dye was selected as a tracer, because it was cheep and easily treatable. Using NIRS(Near Infrared Reflection Spectrophotometer), a regression curves between maximum absorbance of a solution and concentration of the tracer were obtained. Yellow food dye solution showed a peak of spectrum at 452 nm, and absorbance of peak showed a tendency to increase as concentration increased. Green or pink food dye were tested and judged to be good tracers. However, tracer concentration should not exceed certain limits in order to measure maximum absorption. Using spraying liquid with known tracer concentration and known amount of washing liquid, spray deposit amount on real targets on leaves could be estimated at less than 13% error level.

  • PDF

EVALUATION OF RAPID DETERMINATION OF PHOSPHORUS IN SOILS BY NIR SPECTROSCOPY

  • Ryu, Kwan-Shig;Kim, Book-Jin;Park, Jin-Sook
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1072-1072
    • /
    • 2001
  • The purpose of this research is to evaluate rapid determination of phosphorus in soils using NIR spectroscopy. The soil samples from the fields subject to different crops and land-use in Kyeongbook province, Korea were used to make the calibration and validation of the calibration set estimating phosphorus in soil. The NIR reflectance was scanned at 2nm intervals from 1100 to 2500nm with an InfraAlyzer 500 (Bran+Luebbe Co.). Various regression analyses were used to evaluate a NIRS method for determination of phosphorus in the soil. NIR absorption approach requires many soil samples to obtain optimal prediction. Applicability of NIR spectra technique may allow for the analysis of available soil phosphorus rapidly as well as total component within a few seconds.

  • PDF

Profile and Dose Distribution for Therapeutic Heavy Ion Beams

  • Sasaki, Hitomi;Komori, Masataka;Kohno, Toshiyuki;Kanai, Tatsuaki;Hirai, Masaaki;Urakabe, Eriko;Nishio, Teiji
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.211-213
    • /
    • 2002
  • The purpose of this work is acquiring some parameters of therapeutic heavy ion beams after penetrating a thick target. The experiments were performed using a pencil-like $\^$12/C beam of about 3 mm in diameter from NIRS-HIMAC, and the data were taken at several points of the target thickness for $\^$12/C beam of 290 MeV/u and 400 MeV/u. By the simultaneous measurements using some detectors, the atomic number of each fragment particle was identified, and the beam profile, the dose distribution and the LET spectrum for each element were derived.

  • PDF

An Analysis on Treatment Schedule of Carbon Ion Therapy to Early Stage Lung Cancer

  • Sakata, Suoh;Miyamoto, Tadaaki;Tujii, Hirohiko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.174-176
    • /
    • 2002
  • A total of 134 patients with stage 1 of non-small cell lung cancer treated by carbon ion beam of HIMAC NIRS were investigated for control rate and delivered dose. The delivered dose of every patient was converted to biological effective dose (BED) of LQ model using fraction number, dose per fraction and alpha beta ratio which shows the maximum correlation between BED and tumor control. The BED of every patient was classified to establish a BED response curve for control. Assuming fraction numbers, dose response curves were introduced from BED response curve. The total doses to realize several control rates were obtained for the treatment of small fraction number.

  • PDF

NIR을 이용한 쇠고기의 신선도 센서 개발 (Development of Beef Freshness Sensor Using NIR Spectroscopy)

  • 조성인;김유용;박두산;황규영
    • Journal of Biosystems Engineering
    • /
    • 제29권6호
    • /
    • pp.539-543
    • /
    • 2004
  • The purpose of this study was to develop a real-time sensor for beef freshness. Contents of biogenic amines (BA), saccharides and proteins were highly related with freshness on the beef meats. Relations of those chemical contents and NIR spectra were studied. Tyramine showed the best correlation coefficient at 1250nm. Correlation between VBN (volatile basic nitrogen) and K value, which were both freshness measurement method, was determined by the PCR (principle component regression). The correlation model had the values of $R^2=0.989$ and SEC=1.78, respectively. The model was validated at $R^2=0.963$ and SEP=2.285, respectively.

수염 자극 시 대뇌수염피질에서의 혈류변화에 따른 근적외선 신호와 전기신호의 동시측정 (Simultaneous measurements of NIR and electrical signals on rat brain during whisker stimulation)

  • 이승덕;권기운;고달권;호동수;김법민;이현주;랑이란;신형철
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2008년도 동계학술발표회 논문집
    • /
    • pp.455-456
    • /
    • 2008
  • 근적외선 분광법(Near-infrared spectroscopy, NIRS)은 대뇌피질에서의 혈류변화(oxy-, deoxyhemoglobin의 농도변화)를 비침습적으로 측정할 수 있는 방법이다. 본 논문에서는 향후 뇌-컴퓨터 접속기술(Brain computer interface)에 적용하기위한 초기 연구단계로, 쥐의 수염을 자극시 활성화되는 대뇌수염피질 영역에서의 혈류변화 및 전기신호를 동시에 측정하고 두 신호의 패턴을 분석한다.

  • PDF

근적외선 분광분석법을 이용한 유량종자의 원산지 판별 (Discrimination of Oil Seeds According to Geographical Origin Using Near Infrared Reflectance Spectroscopy)

  • 권혜순
    • 한국응용과학기술학회지
    • /
    • 제16권1호
    • /
    • pp.21-24
    • /
    • 1999
  • Sesame seed (Sesamum indicum L.) is an important seasoning in Korea and most korean consumer tend to eat the korean sesame seed as the best than other ones produced in oriental countries such as China and Japan. Near infrared reflectance spectroscopy (NIRS) was applied for discrimination according to geographical origin (Korea, China and so on) of sesame seeds. Near-infrared spectroscopy among the many kinds of techniques could provide a rapid screening, low cost solution to discriminate geographical origin of sesame seed. The objective of this study is to determine if NIR technique could be used to discriminate between the korean sesame seed and non-korean sesame seed by using the new method. Rapid, precise and nondestructive analysis method for determination of the geographic origin of sesame seeds were discriminated relative accurately according to geographical origin using PLS regression method.

근적외선 분광 분석법을 이용한 운동령에서의 사건 기반 산소 포화도 변화 신호 측정 (Measurement of Event-related Hemodynamic Responses on Motor Cortex Measured by Near-infrared Spectroscopy)

  • 이동철;신재영;김지현;정지채
    • 전기학회논문지
    • /
    • 제61권7호
    • /
    • pp.1049-1055
    • /
    • 2012
  • We measure the hemodynamic responses during the 4 kinds of tasks on the motor cortex in the right and left human brain by using near-infrared spectroscopy. The experimental results show that the change of concentration of oxy-hemoglobin is larger than that of deoxy-hemoglobin and the change of concentration of chromophores induced by finger and arm related task show more activations than that of leg.

Determination of the water content in Citrus leaves by portable near infrared (NIR) system

  • Suh, Eun-Jung;Lim, Hun-Rang;Woo, Young-Ah;Kim, Hyo-Jin
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.405.1-405.1
    • /
    • 2002
  • The amount of water for the cultivation of citrus is different based on the growing period. The water content in the leaves of citrus can be a index for watering during cultivation. The purpose of this study is to determine non-destructively the water content of Citrus leaves by using near infrared spectroscopy (NIRS). Citrus leaves were prepared from satsuma mandarin leaves (Citrus unshiu Marc. var. okitsu) ranging from 62.20 to 69.98% of water content by loss on drying, NIR reflectance spectra of Citrus leaves were acquired by using a fiber optic probe. (omitted)

  • PDF