• Title/Summary/Keyword: NIR laser

Search Result 33, Processing Time 0.026 seconds

Time-encoded Near-infrared (NIR) Spectroscopic Comparison of Absorbance Measurement Using an Acousto-optic NIR Swept Laser Source (음향광학 파장선택 필터 기반 파장훑음 레이저를 이용한 시간-인코딩 된 근적외선 흡광도 측정 비교 연구)

  • Jang, Hansol;Kim, Gyeong Hun;Han, Ga-Hee;Cho, Jaedu;Kim, Chang-Seok
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • Time-encoded near-infrared spectroscopy (NIRS) system is proposed, based on a near-infrared (NIR) swept laser source, for comparison to the conventional NIRS method using a detector-type spectrometer. The cavity of the NIR swept laser source consists of a semiconductor optical amplifier (SOA) with a gain region around 800 nm, and several fiber-optic components. To change the output wavelength in time using an applied electric radio-frequency signal, an acousto-optic tunable filter (AOTF) is introduced in the fiber ring cavity configuration. To demonstrate the feasibility of an NIR swept laser source for NIRS imaging, the spectroscopic comparison of two kinds of absorbance-measuring systems a detector-type spectrometer using a white light source, and a source-type spectrometer using an NIR swept laser is successfully performed with an NIR-absorbing dye.

Preparation and Release Properties of Acetaminophen Imprinted Functional Starch based Biomaterials for Transdermal Drug Delivery (경피약물전달을 위한 아세트아미노펜 각인 기능성 전분 기반 바이오 소재 제조 및 방출 특성)

  • Kim, Han-Seong;Kim, Kyeong-Jung;Lee, Si-Yeon;Cho, Eun-Bi;Kang, Hyun-Wook;Yoon, Soon-Do
    • Applied Chemistry for Engineering
    • /
    • v.32 no.3
    • /
    • pp.299-304
    • /
    • 2021
  • This study focuses on the preparation of acetaminophen (AP) imprinted functional biomaterials for a transdermal drug delivery using mung bean starch (MBS), polyvinyl alcohol (PVA), sodium benzoate (S) as a crosslinking agent, glycerol (GL) as a plasticizer, and melanin (MEL) as a photothermal agent. The prepared AP imprinted biomaterials were characterized using FE-SEM and their physical properties were evaluated. The photothermal effect and AP release property for functional biomaterials were examined with the irradiation of near infrared (NIR) laser (1.5 W/cm2). When the NIR laser was irradiated on functional biomaterials with/without the addition of MEL, the temperature of MEL added biomaterial increased from 25 ℃ to 41 ℃, whereas the biomaterial without MEL increased from 25 ℃ to 28 ℃. Results indicate that there is the photothermal effect of prepared biomaterial with the addition of MEL. Based on the results, AP release properties were evaluated using standard buffer solutions and artificial skin. It was found that AP release rates of MEL added AP loaded biomaterials were 1.2 times faster than those of MEL non-added AP loaded biomaterials when irradiating with NIR laser. We envision that the developed functional biomaterials can be utilized for an acute pain-killing treatment.

Synthesis and Characterization of Pentarylene Bisimide Derivative as NIR Colorant (NIR Colorant용 Pentarylene Bisimide의 합성 및 특성 연구)

  • Baek, Kwan;Jeong, Yeon-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.140-146
    • /
    • 2012
  • A variety of dyes are commercially available today, there is an ongoing need for new chromophoric systems and low-band-gap materials. For example, near-infrared (NIR) emission has received increased attention for applications in bioassays and medicine while NIR absorption is demanded for laser-welding of plastics or efficient blocking of heat rays. Most of the commercially available NIR materials are not suitable for such purposes owing to their insufficient stability. We have developed a novel NIR-absorbing polyaromatic dye. By extending the system of perylenebis(dicarboximide)s along the molecular long axis, we have obtained the higher homologue pentarylenebis(dicarboximide). We have tried to introduce imide functional group to pentarylene in order to increase chemical and thermal stability.

Study on Improvement of Signal to Background Ratio of Laser-based Fluorescence Imaging System (레이저 기반 형광 영상 시스템의 Signal to Background Ratio 향상 연구)

  • Kim, J.H.;Jeong, M.Y.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.107-111
    • /
    • 2020
  • Recently, as an aging society progresses, a lot of interest in health and diagnosis is increasing, As the field of various bio-imaging systems for guided surgery capable of accurate diagnosis has emerged as important, a Fluorescence imaging system capable of accurate measurement and real-time confirmation has emerged as an important field. Fluorescence images currently being used are mainly in the NIR-I band, but many studies are in progress in the NIR-II band in order to improve resolution and confirm fluorescence deeply and accurately. In this paper, the difference between NIR-I and NIR-II, optical characteristics, and SBR (signal to background ration) of a fluorescent imaging system, was investigated using the finite element (FEM) method. After confirming, it was confirmed that the SBR was 16.2 times higher in the NIR-II area than in the NIR-I by making the skin phantom and measuring the fluorescence. It is confirmed that the enhancement in SBR of the Fluorescence imaging system is more effective in the NIR-II region than in the NIR-I region and expected to be used in application fields such as guided surgery, bio-sensor and also device which can detect the defect of optical devices.

APPLICATION OF A MULTI-WAVELENGTH NIR DIODE LASER ARRAY FOR NON-DESTRUCTIVE FOOD ANALYSIS

  • Tauscher, Bernhard;Butz, Peter;Lindauer, Ralf
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3123-3123
    • /
    • 2001
  • Near infrared (NIR) spectroscopy has become a widely used method in food and beverage analysis because of its speed, accuracy and the simplicity of sample preparation. One of the basic requirements of NIR instruments is a wide dynamic range if weak, or small, absorption changes or concentrations are to be measured. Thus the instrument must be sufficiently luminous, and efficient, to enable measurements to be made in a reasonably short time, as for some applications (e.g. sorting) short response times are essential. Diode lasers function the same way as lasers but linewidths are not as narrow as typical lasers. In this work an array of seven laser diodes (in the range of 750-1100 nm) with energy outputs of around hundred milliwatts each were combined with a fast diode array spectrometer (400-1100 nm, 1024 pixels, integration time from 3 ms) as detector. Measurements in transmission mode were performed in solutions of sugars in aqueous solutions and in deuteriumoxide. The feasibility of non-destructive measurements in transmission mode was investigated for different fruits and vegetables.

  • PDF

Strain-imposed External Cavity Tunable Lasers Operating for NIR Wavelength

  • Kim, Jun-Whee;Kim, Kyung-Jo;Son, Nam-Seon;Oh, Min-Cheol
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.172-176
    • /
    • 2013
  • For demonstrating widely tunable external cavity lasers operating for near-infrared (NIR) wavelength, a flexible polymer waveguide with an imbedded Bragg grating is incorporated. Due to the superior flexibility of the polymer material, the reflection wavelength of the Bragg grating is widely tunable by imposing tensile and compressive strains on the flexible Bragg grating. A third-order Bragg grating is formed on the device for facilitating the fabrication method. With a superluminescent laser diode as a gain medium of ECL, the tunable laser exhibited output power of -3 dBm and a tuning range of 32 nm.

Streptococcus Mutans Biofilm Inhibition Effect of Indocyanine Green and Near Infrared Diode Laser (Indocyanine Green과 근적외선 다이오드 레이저의 Streptococcus mutans 세균막에 대한 억제 효과)

  • Kim, Yeowon;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.4
    • /
    • pp.446-453
    • /
    • 2020
  • The purpose of this study was to evaluate the effect of Indocyanine Green (ICG) and near-infrared (NIR) diode laser on Streptococcus mutans biofilms depending on ICG concentrations. S. mutans biofilms were formed on a Hydroxyapatite disk, and 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL ICG solutions dissolved in sterile distilled water and a NIR diode laser having a power of 300 mW and a wavelength of 808 nm were applied to the biofilms. The temperature changes of the biofilm surface according to the concentrations of the ICG solution were measured using a 1-channel thermocouple thermometer. Compared to the control group, in the groups with only the 3.0, 4.0, 5.0 mg/mL ICG solution application, and in the groups with the 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL ICG solution application and light irradiation, a statistically significant decrease in the bacterial counts were observed. The temperature increase according to the concentration of the ICG solutions was 9.53℃, 10.43℃, 11.40℃, 12.10℃, 12.67℃, and 13.63℃ in ICG solutions of 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mg/mL respectively. This study presents the potential for clinical application of ICG and NIR diode lasers as a new method for preventing dental caries.

The synthesis and light absorbing properties of heptamethine cyanine chromophores based on benzoxazole derivatives

  • Youn, Hye-Soo;Park, Soo-Youl;Shin, Seung-Rim;Shin, Joung-Il;Oh, Seong-Geun;Jun, Kun
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2008.10a
    • /
    • pp.133-134
    • /
    • 2008
  • A novel near infrared(NIR) absorbing dyes were synthesized by using bis-aldehyde formyl aromatic compounds and heteroaryl derivatives with the reactive methylene group. These dyes provided a range of the NIR wavelength region about 720 nm value. Also, the light absorbing properties of these dyes were investigated in our experiment results. In generally, these NIR colorants may be potential used for optical recording media, DNA sequencing probe and laser beam printings.

  • PDF

Damage Analysis of CCD Image Sensor Irradiated by Continuous Wave Laser (연속발진 레이저에 의한 CCD 영상센서의 손상 분석)

  • Yoon, Sunghee;Jhang, Kyung-Young;Shin, Wan-Soon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.690-697
    • /
    • 2016
  • EOIS(electro-optical imaging system) is the main target of the laser weapon. Specially, the image sensor will be vulnerable because EOIS focuses the incident laser beam onto the image sensor. Accordingly, the laser-induced damage of the image sensor needs to be identified for the counter-measure against the laser attack. In this study, the laser-induced damage of the CCD image sensor irradiated by the CW(continuous wave) NIR(near infrared) laser was experimentally investigated and mechanisms of those damage occurrences were analyzed. In the experiment, the near infrared CW fiber laser was used as a laser source. As the fluence, which is the product of the irradiance and the irradiation time, increased, the permanent damages such as discoloration and breakdown appeared sequentially. The discoloration occurred when the color filter was damaged and then the breakdown occurred when the photodiode and substrate were damaged. From the experimental results, LIDTs(laser-induced damage thresholds) of damages were roughly determined.

The transparent and conducting tin oxide thin films by the pulse laser deposition (펄스레이저증착에 의한 투명전도성 산화주석 박막)

  • 윤천호;박성진;이규왕
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.2
    • /
    • pp.114-121
    • /
    • 1997
  • The transparent conductiong thin films of tin oxides were prepared on pyrex glass substrates by the pulse laser deposition. In the atmospheres of vacuum, O2, and $Sn(CH_3)_4$ a polycrystalline $SnO_2$ target was ablated by Nd-YAG laser beam to deposit thin films on the substrates at room temperature, and as-deposited films were subsequently heat-treated in the air for 2 h at 230, 420 and $610^{\circ}C$, respectively. The characteristics of the thin films were examined by UV-VIS-NIR spectrometry and X-ray diffractometry, and the electrical properties were measured by four-point probe method along with film thickness monitored by the stylus method. It was observed that in the presence of $Sn(CH_3)_4$, $SnO_2$ phases were grown even at room temperature. This suggests that the microplasma producted during the laser ablation plays an important role in the dissociaation of precursor molecules.

  • PDF