• Title/Summary/Keyword: NIR Spectroscopy

Search Result 465, Processing Time 0.027 seconds

Study on non-destructive sorting technique for lettuce(Lactuca sativa L) seed using fourier transform near-Infrared spectrometer (FT-NIR을 이용한 상추(Lactuca sativa L) 종자의 비파괴 선별 기술에 관한 연구)

  • Ahn, Chi-Kook;Cho, Byoung-Kwan;Kang, Jum-Soon;Lee, Kang-Jin
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.1
    • /
    • pp.111-116
    • /
    • 2012
  • Nondestructive evaluation of seed viability is one of the highly demanding technologies for seed production industry. Conventional seed sorting technologies, such as tetrazolium and standard germination test are destructive, time consuming, and labor intensive methods. Near infrared spectroscopy technique has shown good potential for nondestructive quality measurements for food and agricultural products. In this study, FT-NIR spectroscopy was used to classify normal and artificially aged lettuce seeds. The spectra with the range of 1100~2500 nm were scanned for lettuce seeds and analyzed using the principal component analysis(PCA) method. To classify viable seeds from nonviable seeds, a calibration modeling set was developed with a partial least square(PLS) method. The calibration model developed from PLS resulted in 98% classification accuracy with the Savitzky-Golay $1^{st}$ derivative preprocessing method. The prediction accuracy for the test data set was 93% with the MSC(Multiplicative Scatter Correction) preprocessing method. The results show that FT-NIR has good potential for discriminating non-viable lettuce seeds from viable ones.

NIR DIODE ARRAY SPECTROMETERS ON AGRICULTURAL HARVEST MACHINES OVERVIEW AND OUTLOOK

  • Rode, Michael
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1172-1172
    • /
    • 2001
  • Compact Near Infrared Diode Array Spectrometers offer new possibilities for on line quality assurance in the agricultural sector. Due to their speed and complete robustness towards temperature fluctuations and mechanical shock Diode Array Spectrometers are suitable for the use on Agricultural Harvest Machines. The growing consumer consciousness of food quality in combination with falling manufacturing prices demands procedures for an effective quality control system. The various conventional types of NIR instruments which have so far been used in laboratories are unsuitable for mobile applications under the rough conditions of field cropping not only because of their slow speed of measurement but also because of their shock sensitive filter wheels and monochromators necessary for fractionating polychromatic light. Another advantage of the on line use is the reduction of the sampling error because of the continuously measurement of the whole product. Considering the large economic importance of the dry matter content on agricultural products it is of particular advantage that water belongs to those constituents which are most easily assessed in the near infrared. While other constituents of economic importance such as starch, oil and protein in grains and seeds have a much lesser effect on NIR signals, their contents can nonetheless be assessed with high analytical precision on freshly harvested grains and seeds. In the last years several applications for on line quality assessment on harvesting machines were developed and tested. The talk will give an overview and outlook on existing and future possibilities of this new field of NIR applications.

  • PDF

Measurement of the proximate components of fresh ginseng (Panax ginseng C.A Meyer) using Near-Infrared Reflectance Spectroscopy (근적외선(NIR) 분광법에 의한 수삼의 성분 측정)

  • Chang, Kyu-Seob;Lee, Eui-Suk;Lee, Gyu-Hee
    • Korean Journal of Agricultural Science
    • /
    • v.28 no.2
    • /
    • pp.116-124
    • /
    • 2001
  • The measurement values of proximate composition in fresh ginseng could provide the important information for red ginseng processing. The measurement of them were performed by near-infrared (NIR) spectroscopy. Linear regression model for the predicting of proximate composition was developed and validated. The regression values of moisture, crude starch, crude ash, crude fiber, calcium, and magnesium contents were shown as 0.918, 0.951, 0.897, 0.728, 0.933, and 0.390, respectively. Therefore, the proximate composition of fresh ginseng could be measured by NIR, feasibly.

  • PDF

Development of robust Calibration for Determination Sweetness of Fuji Apple fruit using Near Infrared Reflectance Spectroscopy

  • Sohn, Mi-Ryeong;Kwon, Young-Kill;Cho, Rae-Kwang
    • Near Infrared Analysis
    • /
    • v.2 no.1
    • /
    • pp.55-58
    • /
    • 2001
  • The object of this work was to investigate the influence of growing district and harvest year on calibration for sweetness (Brix) determination of Fuji apple fruit using near infrared (NIR) reflectance spectroscopy, and to develop the robust calibration across these variation. The calibration models was based on wavelength range of 1100∼2500 nm using a stepwise multiple linear regression. A calibration model by sample set of one growing district was not transferable to other growing districts. The combined calibration (data of three growing districts) predicted reasonable well against a population set drawn from all growing districts (SEP=0.69, Bias=0.075). A calibration model by sample set of one harvest year was not also transferable to other harvest years. The combined calibration (data of three harvest years) predicted well against a population set drawn from all harvest years (SEP=0.53, Bias=0.004).

THE COMBINATION OF CHEMOMETRICS AND 2D NIR CORRELATION SPECTROSCOPY IN THE ANALYSIS OF DENATURATION PROCESS

  • Czarnik-Matusewicz, Boguslawa;Murayama, Koichi;Wu, Yuqing;Ozaki, Yukihiro
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1286-1286
    • /
    • 2001
  • Despite extensive theoretical and experimental studies the structure of the protein-solvent interface is subject of many controversy. Understanding the processes that occur in aqueous solution requires understanding of the solvent influence on the structure of protein. The aim of this study is to investigate the applicability of NIR methods in the study of hydration phenomena in protein solutions. Temperature-induced changes in NIR spectra of -lactoglobulin (BLG) in aqueous solutions have been investigated by means of two-dimensional correlation spectroscopy (2DCOS) and principal component analysis (PCA). With the temperature increase the balance of forces between the BLG's interaction with itself and the BLGs interaction with its environment is disrupted leading to BLG unfolding. Significant differences of 2D signals and distinct discrepancies of loading on PC1 and PC2 were observed as a result of temperature increase. In the native folded conformation of BLC, most of the nonpolar amino acids are hidden in the centre of the structure, out of contact with water molecules, while charged groups are outside, in the contact with water. The polar groups promote low density Ih-type structure in the water outside this first hydration shell. When BLG unfolds it assumes a more extended configuration on which the previously buried nonpolar groups are exposed to water and promote the higher density II-type structure outside its first shell. Detailed assignments of bands attributed to the bulk water, different states of the hydrated water and the changed conformation of BLG are proposed.

  • PDF

Discrimination and Quantitative Analysis of Watercore in Apple Fruit by Near Infrared Transmittance Spectroscopy

  • Kim, Eun-Ok;Sohn, Mi-Ryeong;Kwon, Young-Kil;Lin, Gou-Lin;Cho, Rae-Kwang
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1529-1529
    • /
    • 2001
  • The watercore in apple is very important factor in storage and sorting of fruit. Most consumers tend to prefer the apple included watercore in immediately after harvest, however the watercore causes fruit flesh to brown during storage and lose the worth after all. But it is practically impossible to judge to the naked eye whether an apple has watercore or not. Therefore, the rapid, accurate and non-destructive analysis method for discrimination of watercore should be settled without delay. In this study we attempted the discrimination and quantitative analysis of watercore in apple fruit using near-infrared transmittance spectroscopy ‘Fuji’ apple fruits produced in Kyungpook of Korea was used in this experiment. The watercore content in apple was evaluated by graphic treatment of culled slice sections(10 mm). NIR transmittance spectra were collected over the 500 to 1000 nm spectral region with a spectrometer (Sentronic Co., Germany). The calibration models were carried out by partial least squares (PLS) analysis between NIR spectra data of apples and chemical data of watercore content. The spectra were different in absorbance between apple included watercore and not included one. Apple included watercore had higher absorption band than sample not included one at 732 and 820 nm. The calibration model seems to be accurate to predict the watercore content in apple fruit, the correlation coefficient (R) and root mean square error of prediction (RMSEP) were 0.99 and 0.93%, respectively. This result indicates that the PLSR calibration model by using NIR transmittance spectroscopy could be used for discrimination of watercore in apple fruit.

  • PDF

Application of Near Infrared Spectroscopy (NIR) for Monitoring the Quality of Milk, Cheese, Meat and Fish - Review -

  • Ru, Y.J.;Glatz, P.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.7
    • /
    • pp.1017-1025
    • /
    • 2000
  • The traditional methods for determining the quality of milk, cheese and meat are tedious and expensive, with a significant wastage of chemicals which pollute the environment. To overcome these disadvantages, the potential of near infrared spectrophotometry (NIR) for monitoring the quality of milk and meat has been evaluated by a number of researchers. While most studies indicate that NIR can be used to predict chemical composition of milk and meat, and to monitor the cutting-point during cheese manufacturing, one study demonstrated the potential of NIR to predict sensory characteristics (e.g. hardness and tenderness) of beef. These calibrations were developed on a small number of samples, limiting their value for adoption by the industries. Now that the sophisticated computer software is available, more robust calibrations need to be developed to monitor both chemical and physical characteristics of meat and meat products simultaneously.

Predicting N-alkane Concentration in Pastures and Deer Faeces for Dietary Composition and Digestibility Measurement Using Near Infrared Spectroscopy

  • Ru, Y.J.;Kruk, J.A.;Fischer, M.;Choct, M.;Glatz, P.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.11
    • /
    • pp.1611-1616
    • /
    • 2002
  • The alkanes in plant materials can potentially be used as markers to estimate composition and digestibility of diet of deer for the development of feeding strategies, but the analysis of alkanes in plant materials and deer faeces is time-consuming and expensive. In this study, 242 faecal samples and 119 pasture samples were scanned using near infrared spectroscopy (NIR) and the concentrations of alkanes in these samples were analysed to develop calibrations for predicting alkane concentrations in pastures and deer faeces. The $R^2$ values for NIR calibrations were <0.6 for $C_{24}$, $C_{26}$, $C_{32}$ and $C_{36}$, but were >0.8 for other alkanes for faecal samples. The $R^2$ values were >0.87 for alkanes with chains from $C_{27}$ to C35 for pasture samples. However, NIR was unable to predict concentrations of alkanes with chains of $C_{24}$, $C_{26}$, $C_{32}$ and $C_{36}$ in faecal samples and $C_{24}$, C25, $C_{26}$ and $C_{36}$ in pasture samples. While the use of these NIR calibrations will accelerate the estimation of diet digestibility, dietary components and botanical composition of pastures, the influence of the type of pasture on NIR calibration will require further examination.

Study on Rapid Measurement of Wood Powder Concentration of Wood-Plastic Composites using FT-NIR and FT-IR Spectroscopy Techniques

  • Cho, Byoung-kwan;Lohoumi, Santosh;Choi, Chul;Yang, Seong-min;Kang, Seog-goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.852-863
    • /
    • 2016
  • Wood-plastic composite (WPC) is a promising and sustainable material, and refers to a combination of wood and plastic along with some binding (adhesive) materials. In comparison to pure wood material, WPCs are in general have advantages of being cost effective, high durability, moisture resistance, and microbial resistance. The properties of WPCs come directly from the concentration of different components in composite; such as wood flour concentration directly affect mechanical and physical properties of WPCs. In this study, wood powder concentration in WPC was determined by Fourier transform near-infrared (FT-NIR) and Fourier transform infrared (FT-IR) spectroscopy. The reflectance spectra from WPC in both powdered and tableted form with five different concentrations of wood powder were collected and preprocessed to remove noise caused by several factors. To correlate the collected spectra with wood powder concentration, multivariate calibration method of partial least squares (PLS) was applied. During validation with an independent set of samples, good correlations with reference values were demonstrated for both FT-NIR and FT-IR data sets. In addition, high coefficient of determination (${R^2}_p$) and lower standard error of prediction (SEP) was yielded for tableted WPC than powdered WPC. The combination of FT-NIR and FT-IR spectral region was also studied. The results presented here showed that the use of both zones improved the determination accuracy for powdered WPC; however, no improvement in prediction result was achieved for tableted WPCs. The results obtained suggest that these spectroscopic techniques are a useful tool for fast and nondestructive determination of wood concentration in WPCs and have potential to replace conventional methods.

SELECTING NIR EQUIPMENT TO MEET THE STRATEGIC REQUIREMENTS OF A GLOBALIZED PHARMACEUTICAL COMPANY

  • Dowd, Chris;Horvath, Steve;Lonardi, Silvano;Salton, Neale;Scott, Chris;Viviani, Romeo
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3113-3113
    • /
    • 2001
  • Some two years ago our company undertook a project on manufacturing network rationalization to maximize competitiveness through continuous improvement in manufacturing efficiency. One key outcome was the recognition of the benefits that could be derived from timely application of new technology or novel use of existing technologies and even more importantly the need to develop company wide strategies to maximize the impact of such applications. As a direct result an exercise was undertaken to identify the ten most promising technologies from a list of literally hundreds seen as having the capability of making a rapid impact on the manufacturing initiative. One of the outcomes of this exercise was the identification of Near Infrared Spectroscopy as a pivotal technology for improving process understanding, performance, and control to deliver consistent product quality cost effectively with broad applicability across our product range. While NIR had been in use in targeted areas on some of our sites for some years our new challenge was to develop a strategy to extend NIRs application, initially over 17 manufacturing sites, while concurrently expanding the NIR skill base company wide to ensure that the return on initial investment could be further maximized as shared applications across the remaining sites as required. This presentation will provide an overview of how life cycle based user requirement specifications were developed covering: ㆍSpectrophotometers ㆍSample interfaces ㆍSoftware ㆍEquipment and Software qualification ㆍCalibration transfer ㆍ Ease of developing effective user interfaces and control for applications transferred to a production area ㆍUser training ㆍWorld wide support The presentation will also describe the process adopted for vendor selection to ensure maximum utilization of the existing company wide NIR skill base and its future development to expedite applications of the technology in development, quality control and production areas.

  • PDF