• Title/Summary/Keyword: NIPS

Search Result 57, Processing Time 0.023 seconds

Structural Changes of PVDF Membranes by Phase Separation Control (상분리 조절에 의한 PVDF막의 구조 변화)

  • Lee, Semin;Kim, Sung Soo
    • Korean Chemical Engineering Research
    • /
    • v.54 no.1
    • /
    • pp.57-63
    • /
    • 2016
  • Thermally induced phase separation (TIPS) and nonsolvent induced phase separation (NIPS) were simultaneously induced for the preparation of flat PVDF membranes. N-methyl-2-pyrrolidone (NMP) was used as a solvent and dibutyl-phthlate (DBP) was used as a diluent for PVDF. When PVDF was melt blended with NMP and DBP, crystallization temperature was lowered for TIPS and unstable region was expanded for NIPS. Ratio of solvent to diluent changed the phase separation mechanism to obtain the various membrane structures. Contact mode of dope solution with nonsolvent determined the dominant phase separation behavior. Since heat transfer rate was greater than mass transfer rate, surface structure was formed by NIPS and inner structure was by TIPS. Quenching temperature of dope solution also affected the phase separation mechanism and phase separation rate to result in the variation of structure.

Nonpharmacologic Pain Relief with Oral 25% Dextrose or/and Pacifier for Newborn Infants (신생아에서 비약물적 통증조절을 위한 25% 경구 포도당과 인공 젖꼭지 사용의 효과)

  • Kim, Min-Kyung;Kim, In-Ah;Jung, Min-Hee;Han, Myung-Ki;Park, Kie-Young;Kim, Bong-Seong;Jin, Hyun-Seong
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.353-358
    • /
    • 2011
  • Purpose: The goal of this study was to compare the efficacy of oral 25% dextrose treatment or/and pacifier for analgesia in healthy newborns during intramuscular injection of a hepatitis B vaccine. Methods: A prospective, randomized, partially blinded, clinical trial was performed in 132 healthy newborns. They were assigned randomly to 4 treatment groups: control group (2 mL distilled water), dextrose group (2 mL 25% dextrose), pacifier group, dextrose+pacifier group (pacifier coating with 25% dextrose) during intramuscular injection of hepatitis B vaccine. For all groups, Neonatal Infant Pain Scale (NIPS), Neonatal Facial Coding System (NFCS), Premature Infant Pain Profile (PIPP) scores were evaluated before the injection, during the injection, and at 2 minutes after the injection. Pain scores were compared among the 4 groups. Results: Maternal and neonatal characteristics were similar among the 4 groups. 25% dextrose treatment led to lower NIPS pain scores during injection (6.4${\pm}$0.9 vs. 5.5${\pm}$1.7, P=0.01) and after injection (1.6${\pm}$2.0 vs. 0.6${\pm}$0.9, P=0.01) and NFCS pain scores after injection (1.5${\pm}$2.3 vs. 0.7${\pm}$0.8, P=0.04) than control group. The number of neonates who feel the pain (indication of scores: NIPS${\geq}$4, NFCS${\geq}$3) decreased (9 (23.1%) vs. 0 (0%), P=0.04 via NIPS, 7 (17.9%) vs. 0 (0%), P=0.02 via NFCS). However, all treatment groups did not decreased PIPP scores, compared with the control group. Conclusion: Oral 25% dextrose is effective than distilled water or using pacifier with or without 25% dextrose in reducing pain during intramuscular injection of hepatitis B vaccinations. Further study based on this preliminary study need about nonpharmacologic management of pain in newborns.

Efficiency Calibration of HPGe Detector in Normal ana Coincidence Mode for the Determination of Prompt Gamma-ray (즉발감마선 측정을 위한 HPGe 검출기의 전계수 또는 동시계수모드에서의 광대역 계측효율 보정)

  • 송병철;박용준;지광용
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • Neutron induced prompt gamma-ray spectroscopy(NIPS) system measures the prompt gamma-ray emitting by the interaction of a neutron with various materials. This system will be of great benefit to scientists worldwide, since it provides the non-destructive measurement of many element in either solid or liquid wastes. In this study, the full-energy-peak (FEP) efficiency calibration for a HPGe detector was constructed in the ${\gamma}$-ray energy range from 80 keV to 8 MeV, using $^{l33}$Ba and >TEX>$^{152}Eu$ RI sources and $ ^{35}Cl(n, ${\gamma}$)^{36}Cl$ thermal neutron captured reaction. The FEP efficiency curve for the higher energies using the $^{35}Cl(n, ${\gamma}$)^{36}Cl$ reaction was normalized with the curve obtained from the RI sources, since the accurate activity of its prompt ${\gamma}$-ray is unknown. The average thermal neutron flux was theoretically calculated using the FEP efficiency curve for the KCl standard solutions. The NIPS system equipped with a ${\gamma}$-${\gamma}$ coincidence setup with two n-type coaxial HPGe detectors was considered in order to reduce the interfering ${\gamma}$-ray background. The FEP efficiency curve for the ${\gamma}$-${\gamma}$ coincidence system was also obtained for full energy range. The performance of the normal and coincidence NIPS system was tested by comparing signal-to-noise ratio in each mode using the reference sample.e.

  • PDF

The effect of sucrose on infants during a painful procedure

  • Joung, Kyoung-Hwa;Cho, Soo-Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.8
    • /
    • pp.790-794
    • /
    • 2010
  • Purpose: The purpose of this study was to test the efficacy of treating the pain among newborn infants associated with a medical procedure with sucrose with regard to overall physiological and behavioral stability. Methods: 103 newborn infants were enrolled in this study. The control group (n=63) did not receive any treatment. The experimental group (n=40) received 2 mL of 24% sucrose solution two minutes before a routine heel stick. The pain was assessed by measurements of physiological changes [e.g. pulse rate, oxygen saturation, salivary cortisol (hydrocortisone)] and behavioral changes [e.g. crying time, and the neonatal infant pain scale (NIPS) for neonates]. Results: There were no differences among the groups with respect to physiological changes associated with the pain from the procedure. However, there were significant group differences in behavioral changes to the pain. In the control group, the median crying time was 13 seconds, while in the experimental group, the median crying time was 3.5 seconds ($P$=.000). In the control group the median NIPS score was 4, while in the experimental group the median NIPS score was 2 ($P$=.000). Conclusions: These findings suggest that sucrose can be an effective method for the management of stress responses in infants with regard to behavior. However, this treatment had no significant physiological effects.

Study in Background Reduction for the Neutron Induced Prompt Gamma-ray Spectroscopy

  • Song, Byoung-Chul;Jee, Kwang-Yong;Park, Yong-Joon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.433-433
    • /
    • 2004
  • Neutron induced prompt gamma-ray spectroscopy (NIPS) system measures the prompt gamma-ray, emitting by the interaction of a neutron with various materials. This system will be of great benefit to scientists worldwide, since it provides the non-destructive measurement of many elements in either solid or liquid wastes. A NIPS facility has been developed in Nuclear Chemistry Research Division, at Korea Atomic Energy Research Institute (KAERI) with the aim of analyzing the major component elements in both aqueous and solid samples.(omitted)

  • PDF

Study on Thermal Neutron Efficiency for Neutron Induced Prompt Gamma-ray Spectrometer Using Various Reflectors (즉발감마선 계측시스템의 반사체를 이용한 열중성자 효율증대 연구)

  • Park, Y.J.;Song, B.C.;Jee, K.Y.
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.426-429
    • /
    • 2003
  • Neutron induced prompt gamma-ray spectroscopy (NIPS) system equipped with a $^{252}Cf$ neutron source and a n-type coaxial HPGe detector was installed for the quantitative analysis of aqueous samples in KAERI, Korea. Since the thermal neutron flux for the $^{252}Cf$ neutron source is relatively low compared to that for the reactor, the use of a thermal neutron reflector in the NIPS system may lead to improved results. The enhancement by using various reflectors was carried out by comparing the Cl peak with or without a cadmium plate between sample and the $^{252}Cf$ source. The use of pyrolitic graphite as a reflector provided a good result.

Isolation of Candidate Nek2-Interating Protein Genes(NIPs)

  • Yu, Jae-Cheol;Jang, Seong-Gi;Ri, Geon-Su
    • Animal cells and systems
    • /
    • v.6 no.2
    • /
    • pp.181-181
    • /
    • 2002
  • Nek2 is a mammalian protein kinase that is structurally homologous to NIMA, a mitotic regulator in Aspergillus nidulans. We recently observed that the Nek2 protein was localized in multiple sites within a cell in a cell cycle state-specific manner. This suggests that Ndk2 is involved in diverse cellular functions during the cell cycle progression. To have a better understanding on cellular functions in which Nek2 participates, we carried out yeast two-hybrid screening and isolated six candidate clones whose products interact with Nek2. Most of Nek2-interacting proteins (NIPs) appear cytoplasmic, suggesting that Nek2 is involved in cellular functions in cytoplasm. Further experiments are under progress to confirm their interactions with Nek2 and to understand their biological significance.

Development of Neutron Induced Prompt γ-ray Spectroscopy System Using 252Cf (252Cf 선원을 이용한 즉발감마선 계측시스템 구성)

  • Park, Yong-Joon;Song, Byung-Chul;Jee, Kwang-Yong
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2003
  • For the design and set-up of neutron induced prompt ${\gamma}$-ray spectroscopy system using $^{252}Cf$ neutron source, the effects of shielding and moderator materials have been examined. The $^{252}Cf$ source being used for TLD badge calibration in Korea Atomic Energy Research Institute was utilized for this preliminary experiment. The ${\gamma}$-ray background and prompt ${\gamma}$-ray spectrum of the sample containing Cl were measured using HPGe (GMX 60% relative efficiency) located at the inside of the system connected to notebook PC at the outside of the system (about 20 meter distance). The background activities of neutron and ${\gamma}$-rays were measured with neutron survey meter as well as ${\gamma}$-ray survey meters, respectively and the system was designed to minimize the activities. Prompt ${\gamma}$-ray spectrum was measured using ${\gamma}$-${\gamma}$ coincident system for reduce the background and the continuum spectrum. The optimum system was designed and set up using the experimental data obtained.

The Effect of Oral Glucose on Pain Relief in Newborns (신생아의 통증완화를 위한 포도당 경구투여 효과)

  • Ahn, Hye-Young;Jang, Me-Young;Hur, Myung-Haeng
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.6
    • /
    • pp.992-1001
    • /
    • 2006
  • Purpose: This study was done to provide data for a nursing intervention to alleviate newborn pain clinically by investigating the effect of oral glucose. Methods: Subjects were newborns hospitalized in the nursery. Informed consent was obtained from parents of 60 newborns. A heel stick was carried out for a test on 3 groups; the experimental, placebo, and control group. The Neonatal infant pain scale(NIPS), respiration rate, heart rate, peripheral oxygen partial pressure($SpO_2$), and crying duration were measured to assess pain reaction. All neonatal behaviors were recorded on videotape. Results: There were significant differences in pain behavior during stimulus(F=4.195, p=.020), pain behavior immediately after blood-sampling (F=4.114, p=.021), and pain behavior 3 minutes after that (F=3.630, p=.033). However, there were no significant differences in heart rate, respiration rate, peripheral oxygen partial pressure or crying duration after the heel stick among the groups. Conclusions: Oral administration of glucose before a heel stick caused the reduction of neonatal pain behavior, which means that it has an effect of pain relief.