• 제목/요약/키워드: NI method

검색결과 1,889건 처리시간 0.033초

강화형 글라스 아이오노머 합착용 시멘트의 접합강도 및 변연누출에 대한 연구 (COMPARISON OF SHEAR BOND STRENGTH AND MARGINAL LEAKAGE OF RESIN MODIFIED GLASS IONOMER CEMENTS)

  • 박혜양;오남식;이근우;이호용
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.647-661
    • /
    • 1997
  • The resin modified glass ionomer cements(RMGICs) have been used for years since 1989. Recently it has been developed for luting of fixed restorations. To evaluate the bond strength and marginal leakage of RMGICs for luting usage, the 80 extracted human molars which had uniform area of exposed dentin were cemented with 3 types of RMGICs(Fuji Duet, Advance, Vitremer), a conventional Glass Ionomer Cement(GIC-Fuji I), and a resin cement (Panavia 21) to base metal alloy(Ni-Cr-Be). After thermocycling the specimens were immersed in basic fuschin dye for measuring marginal leakage. The shear bond strength was measured with Instron and the maximum dye penetration was measured to 0.1mm. The types of fractured patterns were determined with stereoscope(${\times}7.5$). The results are as follows. 1. The difference between 3 RMGICs and a conventional GIC in shear bond strength was not statistically significant. It seemed that RMGICs had lower shear bond strength than resin cement. (p<0.01) 2. The mean scores of marginal leakage had no significant difference between the resin cement and 3 RMGICs but it was much higher in conventional GIC than the RMGICs (p<0.05) 3. It was determined that the manufacturer and the methods of dentin pretreatment determined the pattern of fracture surfaces and the frequency of adhesive failure between teeth and 3 RMGICs standed as in following order - Vitremer, Advance, Fuji Duet. (p<0. 01) When the fracture pattern was analyzed, it could be said that the materials and the method of dentin pretreatment have much effect on bonding states. This means that the dentin bonding agents should be improved. But the limited products in this experiment can not evaluate the physical properties of the entire RMGICs. Therefore a further study which can evaluate various RMGICs should be in progress to develope better cements.

  • PDF

Stress-Governed Expression and Purification of Human Type II Hexokinase in Escherichia coli

  • Jeong, Eun-Ju;Park, Kyoung-Sook;Yi, So-Yeon;Kang, Hyo-Jin;Chung, Sang-J.;Lee, Chang-Soo;Chung, Jin-Woong;Seol, Dai-Wu;Chung, Bong-Hyun;Kim, Moon-Il
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권4호
    • /
    • pp.638-643
    • /
    • 2007
  • The full encoding sequence for human type II hexokinase (HXK II) was cloned into the E. coli expression vector pET 21b and expressed as a C-terminally hexahistidine-tagged protein in the BL2l (DE3) strain. The IPTG-induced HXK II approximately accounted for 17% of the total E. coli proteins, and 81% of HXK $II_{6{\times}His}$ existed in inclusion bodies. To improve the production of soluble recombinant HXK II protein, in the functionally active form, we used low temperature, and the osmotic stress expression method. When expressed at $18^{\circ}C$, about 83% of HXK $II_{6{\times}His}$ existed in the soluble fraction, which amounted to a 4.1-fold yield over that expressed at $37^{\circ}C$. The soluble form of HXK $II_{6{\times}His}$ was also highly produced in the presence of 1M sorbitol under the standard condition $(37^{\circ}C)$, which indicated that temperature downshift and low water potentials were required to improve the yield of active recombinant HXK II protein. The expressed protein was purified by metal chelate affinity chromatography performed in an IDA Excellose column charged with $Ni^{2+}$ ions, resulting in about 40mg recombinant HXK II protein obtained with purity over 89% from 51 of E. coli culture. The identity of HXK $II_{6{\times}His}$ was confirmed by Western blotting analysis. Taken together, using the stress-governed expression described in this study, human active HXK II can be purified in sufficient amounts for biochemical and biomedical studies.

위성 고도계와 해수면 재구성 자료를 이용한 기후변동성에 따른 태평양 해수면 변화 (Pacific Sea Level Variability associated with Climate Variability from Altimetry and Sea Level Reconstruction Data)

  • 차상철;문재홍
    • Ocean and Polar Research
    • /
    • 제40권1호
    • /
    • pp.1-13
    • /
    • 2018
  • Previous studies have indicated a great regional difference in Sea Level Rise (SLR) in the Pacific and it has been suggested that this is linked to climate variability over the past two decades. In this study, we seek to identify the possible linkage between regional sea level and Pacific climate variability from altimetry-based sea level data (1993-2012) and further investigate how the Pacific sea level has changed spatially and temporally over the past 60 years from long-term sea level reconstruction data (1953-2008). Based on the same method as Zhang and Church (2012), the Inter-annual Climate Index (ICI) associated with the El $Ni{\tilde{n}}o-Southern$ Oscillation (ENSO) and the Decadal Climate Index (DCI) associated with Pacific Decadal Oscillation (PDO) are defined and then the multiple variable linear regression is used to analyze quantitatively the impact of inter-annual and decadal climate variability on the regional sea levels in the Pacific. During the altimeter period, the ICI that represents ENSO influence on inter-annual time scales strongly impacts in a striking east-west "see-saw mode" on sea levels across the tropical Pacific. On the other hand, the decadal sea level pattern that is linked to the DCI has a broad meridional structure that is roughly symmetric in the equator with its North Pacific expression being similar to the PDO, which largely contributes to a positive SLR trend in the western Pacific and a negative trend in the eastern Pacific over the two most recent decades. Using long-term sea level reconstruction data, we found that the Pacific sea levels have fluctuated in the past over inter-annual and decadal time scales and that strong regional differences are presented. Of particular interest is that the SLR reveals a decadal shift and presents an opposite trend before and after the mid-1980s; i.e., a declining (rising) trend in the western (eastern) Pacific before the mid-1980s, followed by a rising (declining) trend from the mid-1980s onward in the western (eastern) Pacific. This result indicates that the recent SLR patterns revealed from the altimeters have been persistent at least since the mid-1980s.

화력발전소의 혼합연료 사용에 따른 중금속 배출량 변화 연구 (A Study on the Changes in Heavy Metal Emissions when Using Mixed Fuel in a Thermal Power Plant)

  • 송영호;김옥;박상현;이진헌
    • 한국환경보건학회지
    • /
    • 제44권1호
    • /
    • pp.63-75
    • /
    • 2018
  • Objectives: The aim of this research is to explore the total heavy metals from a coal-fired power plant burning bituminous coal with wood pellets due to the implementation of the Renewable Portfolio Standard policy (RPS, 10% of electricity from renewable energy resources by 2023). Methods: The research was carried out by collecting archival data and using the USEPA's AP-42 & EMEP/EEA compilation of emission factors for use in calculating emissions. The Monte Carlo method was also applied for carrying out the calculations of measurement uncertainty. Results: In this paper, the results are listed as follows. Sb was measured at 110 kg (2015) and calculated as 165 kg (2019) and 201 kg (2023). Cr was measured at 1,597 kg (2015) and calculated as 1,687 kg (2019) and 1,728 kg (2023). Cu was measured at 2,888 kg (2015) and calculated as 3,133 kg (2019) and 3,264 kg (2023). Pb was measured at 2,580 kg (2015) and calculated as 2,831 kg (2019) and 2,969 kg (2023). Mn was measured at 3,011 kg (2015) and calculated as 15,034 kg (2019) and 23,014 kg (2023). Hg was measured at 510 kg (2015) and calculated as 513 kg (2019) and 537 kg (2023). Ni was measured at 1,720 kg (2015) and calculated as 1,895 kg (2019) and 1,991 kg (2023). Zn was measured at 7,054 kg (2015) and calculated as 9,938 kg (2019) and 11,778 kg (2023). Se was measured at 7,988 kg (2015) and calculated as 7,663 kg (2019) and 7,351 kg (2023). Conclusion: This shows that most heavy metals would increase steadily from 2015 to 2023. However, Se would decrease by 7.9%. This analysis was conducted with EMEP/EEA's emission factors due to the limited emission factors in South Korea. Co-firewood pellets in coal-fired power plants cause the emission of heavy metals. For this reason, emission factors at air pollution control facilities would be presented and the replacement of wood pellets would be needed.

만곡 근관에서 엔진 구동용 Ni-Ti File과 초음파 기구에 의한 근관성형 능력의 비교 (THE COMPARISON OF CANAL SHAPING ABILITY BY ENGINE-DRIVEN NICKEL-TITANIUM FILE AND ENDOSONIC FILE IN CURVED CANAL)

  • 김현주;오원만;양규호
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.758-767
    • /
    • 1995
  • The purpose of this study was to evaluate canal shaping ability after canal preparation by using engine-driven nickel-titanium file and endosonic file in curved canals. 30 mesiobuccal canals of molars extracted within recent 3 months were divided into 3 groups. Group I and group II were prepared by using engine-driven nickel-titanium Gates-Glidden drill type and the engine-driven nickel-titanium file type. Group III prepared by using en do sonic file. The image of preinstrumented canals was taken by X-ray. The image of postinstrumented canal was taken by X-ray in the same condition of preinstrumentation. A magnified X-ray image on magnifier screen was traced and then compared the preinstrumentated canal image with the postinstrumentated canal image by superimposing method. The following results were obtained : 1. In the change of canal curvature, the engine-driven nickel-titanium Gates-Glidden drill type showed the least change and the ultrasonically filing showed the greatest change. 2. In the percentage of canal enlargement, the engine-driven nickel-titanium file type was greatest at all level(p<0.05), the apex of all group was the greatest, the difference of ultrasonically filing group showed greater between apex and cervix. 3. The percentage of canal enlargement on convex side was greater than that of on concave side in apex of each group(p<0.05). In the ultrasonically filing group, both sides of canal enlargement showed sharply difference(p<0.01). 4. The percentage of canal enlargement on convex side was greater than that of on concave side in the third of cervix of the engine-driven nickel-titanium file type and the ultrasonically filling. The percentage of canal enlargement of convex and concave side in the third of middle of the engine-driven nickel-titanium Gates-Glidden drill type show a similar canal enlargement between convex side and concave side. As above result, the engine-driven nickel-titanium file type was greater in canal enlargement than the other instruments. The engine-driven nickel-titanium Gates-Glidden dirll type was efficient endodontic instrument for curved canal preparation because it was least change in canal curvature.

  • PDF

필름 스피커 적용을 위한 PZT/polymer 복합체의 후막 제조 및 압전 특성 평가

  • 손용호;어순철;김성진;권성열;권순용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.346-346
    • /
    • 2007
  • 압전세라믹 재료는 현재 압전 변압기, actuator, transducer, sensor, speaker 등에 광범위하게 이용이 되고 있다. 이 중에서 압전세라믹 소결체를 이용한 스피커의 제조는 가공이 까다롭고, 대형의 크기로 제작 시 소자가 깨지는 등의 많은 제약을 받고 있으며, 저음 특성이 떨어져 응용 범위가 한정되어 있다. 따라서 최근에는 이러한 단점을 극복하기 위하여 세라믹/고분자 복합체를 이용한 필름 스피커를 제작하고자 시도하고 있다. 이러한 세라믹/고분자 0-3형 압전 복합체를 이용할 경우, 제품의 경량화를 실현할 수 있고, 크기나 환경의 영향을 거의 받지 않으므로, 고기능성 스피커로의 응용에 적합할 것으로 보인다. 따라서 본 연구에서는 PZT계의 세라믹와 PVDF, PVDF-TrFE, Polyester, acrylic resin 등의 여러 고분자 물질과의 복합체를 제조하여 압전특성을 평가하였다. 본 실험은 먼저 $(Pb_{1-a-b}Ba_aCd_b)(Zr_xTi_{1-x})_{1-c-d}(Ni_{1/3}Nb_{2/3})_c(Zn_{1/3}Nb_{2/3})_dO_3$ (이하 PZT라 표기)의 최적화 조성을 선택하여, $1050^{\circ}C$에서 소결된 분말을 48시간 ball milling방법 로 약 $1{\mu}m$ 크기로 분쇄하였다. 고분자 물질들은 알맞은 용제들을 선택하여 녹였다. 그 다음 소결된 PZT분말과 고분자를 50:50, 60:40, 65:35, 70:30등의 무게 분율로 혼합하고, 분산제, 소포제 등을 첨가하여 3단 roll mill을 이용하여 충분히 분산시켜 페이스트 (Paste)를 제조하였다. 제조된 페이스트를 ITO가 코팅된 PET필름 위에 스크린 프린팅 법을 사용하여 인쇄하여 $120^{\circ}C$에서 5분간 건조하였다. 코팅된 복합체의 두께는 약 $80{\mu}m$ 정도로 측정되었다. Ag 페이스트를 이용한 상부 전극 형성에도 스크린 프린팅 법을 적용하였다. 이를 $120^{\circ}C$에서 4 kV/mm의 DC 전계로 분극 공정을 수행한 후 전기적 특성을 평가하였다. 유전특성을 조사하기 위해서 LCR meter (EDC-1620)를 사용하였고, 시편의 결정구조는 XRD (Rigaku; D/MAX-2500H)을 통해 분석하였으며, 전자현미경(SEM)을 이용하여 미세구조를 분석하였다. 압전 전하상수$(d_{33})$ 값은 APC 8000 모델을 이용하여 측정하였다. PZT의 혼합비가 증가할수록 비유전율 및 압전 전하 상수 등의 전기적 특성이 증가되었다. 또 여러 고분자 물질 중에서 PVDF-TrFE 수지가 가장 우수한 특성을 보였다. 이는 PVDF-TrFE 수지가 압전성을 나타내기 때문인 것으로 판단되었다.

  • PDF

압전 세라믹을 이용한 전기 발전 (Electric Power Generation from Piezoelectric Ceramics)

  • 백종후;신범승;임은경;김창일;임종인;이영진;최병현;김동국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.304-304
    • /
    • 2006
  • 기계적 에너지를 전지적 에너지로 변환하는 에너지 변환소자인 압전 세라믹스는 액츄에이터, 변압기, 초음파모터, 초음파 소자 및 각종 센서로 응용되고 있으며, 그 응용분야는 크게 종가하고 있다. 최근 이러한 에너지변환 소자를 앞으로 도래하는 유비쿼터스 무선 모바일 시대의 휴대용 전자제품, 즉 Wearable 컴퓨터, MP3, GSM, Bluetooth 등의 정보통신기기, Robotics, 항공우주, 자동차, 의료, 건축, MEMS 분야 등의 대체 에너지원으로 응용하기 위한 연구가 진행되고 있다. 특히 인간의 동작등과 같은 일상적인 동작(Typing, U. limbbing, Breathing, Walking 등)으로 필요한 전력을 얻을 수 있고, 세라믹 소자를 이용하기 때문에 전자노이즈가 발생되지 않을 뿐 아니라 반영구적으로 사용할 수가 있어서, 기존 이차전지, 연료전지를 대체 또는 보완 할 수 있는 방안도 검토되고 있다. 따라서 본 연구에서는 향후 응용 가능성이 큰 압전 발전 시스템을 제작하기 위해서 압전특성이 우수한 조성시스템 설계, 바이몰프 형태의 압전액츄에이터 제작, 그리고 발전시스템의 회로설계를 수행하였다.

  • PDF

Direct Imaging of Polarization-induced Charge Distribution and Domain Switching using TEM

  • 오상호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.99-99
    • /
    • 2013
  • In this talk, I will present two research works in progress, which are: i) mapping of piezoelectric polarization and associated charge density distribution in the heteroepitaxial InGaN/GaN multi-quantum well (MQW) structure of a light emitting diode (LED) by using inline electron holography and ii) in-situ observation of the polarization switching process of an ferroelectric Pb(Zr1-x,Tix)O3 (PZT) thin film capacitor under an applied electric field in transmission electron microscope (TEM). In the first part, I will show that strain as well as total charge density distributions can be mapped quantitatively across all the functional layers constituting a LED, including n-type GaN, InGaN/GaN MQWs, and p-type GaN with sub-nm spatial resolution (~0.8 nm) by using inline electron holography. The experimentally obtained strain maps were verified by comparison with finite element method simulations and confirmed that not only InGaN QWs (2.5 nm in thickness) but also GaN QBs (10 nm in thickness) in the MQW structure are strained complementary to accommodate the lattice misfit strain. Because of this complementary strain of GaN QBs, the strain gradient and also (piezoelectric) polarization gradient across the MQW changes more steeply than expected, resulting in more polarization charge density at the MQW interfaces than the typically expected value from the spontaneous polarization mismatch alone. By quantitative and comparative analysis of the total charge density map with the polarization charge map, we can clarify what extent of the polarization charges are compensated by the electrons supplied from the n-doped GaN QBs. Comparison with the simulated energy band diagrams with various screening parameters show that only 60% of the net polarization charges are compensated by the electrons from the GaN QBs, which results in the internal field of ~2.0 MV cm-1 across each pair of GaN/InGaN of the MQW structure. In the second part of my talk, I will present in-situ observations of the polarization switching process of a planar Ni/PZT/SrRuO3 capacitor using TEM. We observed the preferential, but asymmetric, nucleation and forward growth of switched c-domains at the PZT/electrode interfaces arising from the built-in electric field beneath each interface. The subsequent sideways growth was inhibited by the depolarization field due to the imperfect charge compensation at the counter electrode and preexisting a-domain walls, leading to asymmetric switching. It was found that the preexisting a-domains split into fine a- and c-domains constituting a $90^{\circ}$ stripe domain pattern during the $180^{\circ}$ polarization switching process, revealing that these domains also actively participated in the out-of-plane polarization switching. The real-time observations uncovered the origin of the switching asymmetry and further clarified the importance of charged domain walls and the interfaces with electrodes in the ferroelectric switching processes.

  • PDF

Ni기 초내열합금 GTD111 DS의 고온 저주기 피로수명 예측 (Life Prediction of Low Cycle Fatigue for Ni-base Superalloy GTD111 DS at Elevated Temperature)

  • 김진열;윤동현;김재훈;배시연;장성용;장성호
    • 대한기계학회논문집A
    • /
    • 제41권8호
    • /
    • pp.765-770
    • /
    • 2017
  • Ni기 초내열합금인 GTD111 DS는 가스터빈 블레이드에 사용된다. 본 논문에서는 실제 운전조건과 유사한 조건을 설정하여 GTD111 DS의 저주기 피로시험을 실시하였다 상온, $760^{\circ}C$, $870^{\circ}C$의 온도범위와 다양한 변형률에서 저주기 피로시험을 수행하였다. 실험결과 총 변형률이 증가함에 따라 피로수명은 감소하였다. 상온 및 $760^{\circ}C$에서는 주기적 경화반응이 나타났으며 $870^{\circ}C$에서는 주기적 연화반응이 나타났다. $870^{\circ}C$에서 응력완화 현상은 유지시간에 따른 크리프의 영향으로 나타났다. 피로수명과 총 변형률의 관계는 Coffin-Manson 식을 통해 얻었다. 파단면은 SEM을 통해 초기균열 및 피로진전지역을 관찰하였다.

돼지분뇨슬러리의 액비조내 저장깊이별 고형물 및 질소, 인의 함량분포에 관한 연구 (The Changes of Solid, Nitrogen and Phosphorus Concentrations in Pig Slurry Stored at Various Depth of Slurry Storage Tank)

  • 정광화;정의수;박치호;곽정훈;최동윤;유용희
    • 한국축산시설환경학회지
    • /
    • 제12권3호
    • /
    • pp.161-168
    • /
    • 2006
  • 본 연구는 돼지분뇨 슬러리의 액비화시 저장깊이(매 30m 깊이별)에 따른 액비의 수직 적층형 단면을 구분하여 각 단면별로 유기물 및 질소와 인의 농도변화 및 고형물의 분포 형태를 분석하여 액비의 수직 단면별 특성을 구명하고자 수행되었으며 주요 결과는 다음과 같다. 1. 침전깊이가 깊어짐에 따라 총고형물 농도는 증가하는 경향을 보인 반면에 총고형물중에 함유된 용해성 물질은 감소하였다. 2. 침전깊이별 오염물 농도는 깊이에 따라 증가하여 저장조 전체깊이 대비 약 70% 정도 내외에서 급격하게 증가하는 경향을 보였다. 3. 총질소와 총인 역시 침전깊이가 깊어짐에 따라 증가하는 결과를 보였는데, 이러한 경향은 총 인의 경우에 있어 더 뚜렷했고 질소의 농도변화는 상대적으로 적었다. 4. 저장 깊이가 깊어짐에 따라 Cr과 Ni 등의 함량도 증가하는 경향을 보였고 그 증가 경향치는 SS의 농도변화와 유사하였다.

  • PDF