• 제목/요약/키워드: NEMA

검색결과 155건 처리시간 0.027초

방사선 검사 관련 의료장비와 PACS 간의 연동을 위한 DICOM 및 Non-DICOM 인터페이스 방안 (Methods of DICOM and Non-DICOM Interfacing for various Radiological Equipments with PACS)

  • 김현철
    • 대한디지털의료영상학회논문지
    • /
    • 제6권1호
    • /
    • pp.51-64
    • /
    • 2003
  • This thesis describes the effective interfacing methods of PACS Modality based on the system installation andoperating experiences. PACS(Picture Archiving and Communication Systems) is a system for medical image archiving and communication using large storage device and high-speed network. The standard communication protocol of PACS is DICOM(Digital Imaging and Communication in Medicine) based on TCP/IP and point-to-point protocol. However, there are many Non-DICOM Modalities and DICOM Modalities having problems. First, we had interfaced almost modalities. Fuji CR, GE CT, MRI, Angio, Fluoro, Phillips Angio, Shimadzu Fluoro. Ultrasound PACS, with the main PACS in the Seoul S Hospital as large scale hospital. And we manipulated the intelligent image distribution and the CT. MRI Interfaces never experienced beforein the Anyang J Hospital and the Chungju C Hospital as mid or small scale hospital. Technically, we developed both the DICOM Interface and the Non-DICOM Interface. At the last, the DICOM Worklist and the DICOM Print Interface were implemented in the Seoul B Hospital, the Bucheon SJ Hospital and the Seoul K Hospital independently with PACS. The Oracle, Sybase and MS-SQL are used as database, and UNIX, Macintosh, MS Windows as operating systems. And the Visual C++ and UNIX C are the main programming tools. We have used UTP, coaxial and fiber optic cable under 10/100 mbps LAN for networking.

  • PDF

방사선 검사 관련 의료장비와 PACS 간의 연동을 위한 DICOM 및 Non-DICOM 인터페이스 방안 (Methods of DICOM and Non-DICOM Interfacing for various Radiological Equipments with PACS)

  • 김현철
    • 대한디지털의료영상학회논문지
    • /
    • 제5권1호
    • /
    • pp.46-63
    • /
    • 2002
  • This thesis describes the effective interfacing methods of PACS Modality based on the system installation and operating experiences. PACS(Picture Archiving and Communication Systems) is a system for medical image archiving and communication using large storage device and high-speed network. The standard communication protocol of PACS is DICOM(Digital Imaging and Communication in Medicine) based on TCP/IP and point-to-point protocol. However, there are many Non-DICOM Modalities and DICOM Modalities having problems. First, we had interfaced almost modalities, Fuji CR, GE CT, MRI, Angio, Fluoro, Phillips Angio, Shimadzu Fluoro, Ultrasound PACS, with the main PACS in the Seoul S Hospital as large scale hospital. And we manipulated the intelligent image distribution and the CT, MRI Interfaces never experienced before in the Anyang J Hospital and the Chungju C Hospital as mid or small scale hospital. Technically, we developed both the DICOM Interface and the Non-DICOM Interface. At the last, the DICOM Worklist and the DICOM Print Interface were implemented in the Seoul B Hospital, the Bucheon SJ Hospital and the Seoul K Hospital independently with PACS. The Oracle, Sybase and MS-SQL are used as database, and UNIX, Macintosh, MS Windows as operating systems. And the Visual C++ and UNIX C are the main programming tools. We have used UTP, coaxial and fiber optic Gable under 10/100 mbps LAN for networking.

  • PDF

A Study on the Difference Method of Magnetic Resonance Signal Measurement when Using Multi-channel Coil and Parallel Imaging

  • Choi, Kwan-Woo;Lee, Ho-Beom;Son, Soon-Yong;Jeong, Mi-Ae
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.220-226
    • /
    • 2017
  • SNR (signal to ratio) is a criterion for providing objective information for evaluating the performance of a magnetic resonance imaging device, and is an important measurement standard for evaluating the quality of MR (Magnetic Resonance) image. The purpose of our study is to evaluate the correct SNR measurement for multi-channel coil and parallel imaging. As a result of research, we found that both T1 and T2 weighted images show the narrowest confidence interval of the method recommended by NEMA (The National Electrical manufacturers Association) 1 having a single measurement method, whereas the ACR (American College of Radiology) measurement method using a multi-channel coil and a parallel imaging technique shows the widest confidence interval. There is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a ACR measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

Globalization of Korean Electrical Installations Standards and Codes Based on Comparison of IEC 60364 with NFPA

  • Ki, Chung-Young;Ro, Kwak-Hee;Seop, Shin-Hyo;Joo, Nam-Taik
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2001년도 추계학술대회 논문집
    • /
    • pp.118-125
    • /
    • 2001
  • Most of the laws and standards relevant to technology in Korea bear a resemblance to those in Japan. Electricity was not introduced to Korea until Lighting ceremony in Kyong-Bok palace observed in 1887. Since Korea was annexed to Japan in 1910 and our public works were under Japan control we have applied Japanese laws and regulations made by Chosun government-general. Independently from Japan the power electricity accepted power plants of USA, codes of NESC, ASME / ANSI, NEMA. Our generation and distribution system takes American style while our consumer side takes Japanese style. As global trade system was transferred GATT into WTO, the harmonization of technological standards, certification construction testing in the trend of world. This paper is based on WTO / TBT agreement coming in effect after 12th, April, 1979. For Korea the distribution system has a strong resemblance to American system so that unconvertible because IEC 60364 originated from Europe while NEC originated from USA. This papers deals with the fundamental elements of electrical safety system with comparing IEC 60364 with NEC. This paper considers how engineers should apply NFPA 70(NEC) and IEC based on the comparison of NEC to IEC in relation to electrical installations.

  • PDF

Time Shifted Pilot Signal Transmission With Pilot Hopping To Improve The Uplink Performance of Massive MIMO System For Next Generation Network

  • Ruperee, Amrita;Nema, Shikha
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권9호
    • /
    • pp.4390-4407
    • /
    • 2019
  • The paucity of pilot signals in Massive MIMO system is a vital issue. To accommodate substantial number of users, pilot signals are reused. This leads to interference, resulting in pilot contamination and degrades channel estimation at the Base Station (BS). Hence, mitigation of pilot contamination is exigency in Massive MIMO system. The proposed Time Shifted Pilot Signal Transmission with Pilot signal Hopping (TSPTPH), addresses the pilot contamination issue by transmitting pilot signals in non-overlapping time interval with hopping of pilot signals in each transmission slot. Hopping is carried by switching user to new a pilot signal in each transmission slot, resulting in random change of interfering users. This contributes to the change in channel coefficient, which leads to improved channel estimation at the BS and therefore enhances the efficiency of Massive MIMO system. In this system, Uplink Signal Power to Interference plus Noise Power Ratio (SINR) and data-rate are calculated for pilot signal reuse factor 1 and 3, by estimating the channel with Least Square estimation. The proposed system also reduces the uplink Signal power for data transmission of each User Equipment for normalized spectral efficiency with rising number of antennas at the BS and thus improves battery life.

전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가 (The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT)

  • 곽인석;이혁;최성욱;석재동
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.21-25
    • /
    • 2010
  • PET/CT검사에 있어서 CT는 해부학적인 정보를 제공할 뿐 아니라 PET영상에 대한 감약 정보를 제공하는 역할을 하고 있다. CT의 감약차를 이용하는 것으로서 검사 부위에 존재하는 여러 가지 변수에 의해 그 정도가 달라질 수 있다. 이것은 현재 본 원에서 PET/CT검사 시에 팔을 몸 옆에 두고 검사하는 것에도 적용할 수 있으며, 이에 본 논문에서는 일부 타 병원에서 시행하고 있는 팔을 머리 위로 올리고 검사하는 방법과 함께 CT값의 변화에 따른 표준섭취계수의 변화를 비교 연구했다. NEMA 1994 PET 모형의 삽입체와 모형의 부피를 고려하여 4:1의 비율로 $^{18}F$-FDG를 주입하였다. 먼저 테플론 삽입체 두 개를 NEMA 1994 PET 모형의 양 옆에 고정시켜 팔을 내리고 있는 상태를 가정하여 영상을 얻었으며 테플론 삽입체를 제거하여 팔을 머리 위로 올린 상태를 가정하여 영상을 얻었다. 앞의 과정을 거쳐 얻은 영상을 재구성 하여 Volume Viewer를 이용해 한 영상면 당 5개의 관심 체적을 설정했고 각 측정값을 평균하여 얻어낸 CT값과 표준섭취계수로 그 변화를 측정하였다. 측정된 값과 폐 관련 암환자의 간에 관심 영역을 설정하고 측정한 값을 비교하여 실제 임상 영상에서의 차이를 측정하였다. 모형 실험결과 테플론 삽입체를 부착하였을 때보다 테플론 삽입체를 부착하지 않았을 때 CT값이 -5.8 HU에서 0 HU으로 평균 5.8 HU 증가하였고 표준섭취계수는 24.64에서 24.29로 평균 0.35 감소하였다. 축방향 균일도는 0.064에서 0.052로 평균 0.012 감소하였다. 환자 실험결과 팔을 내리고 검사하였을 때보다 팔을 머리 위로 올리고 검사하였을 때 CT값은 54.1 HU에서 59.9 HU로 평균 5.8 HU 증가하였고 표준섭취계수는 2.02에서 1.85로 평균 0.17 감소하였다. 테플론 삽입물을 부착한 상태로 검사할 때 보다 테플론 삽입물을 부착하지 않은 상태로 검사할 때 CT값은 증가하고 표준섭취계수는 감소하는 양상을 보였다. 이러한 현상이 일어나는 이유는 감약의 정도와 표준섭취계수의 상관관계에서 찾을 수 있다. CT값이 증가할수록 감약 계수는 비례하여 증가하는데 이것은 결국 CT값이 증가될수록 감약이 증가된다고 볼 수 있다. 따라서 팔에 의해 감약이 과다하게 측정될 수 있으므로 결국 표준섭취계수의 증가로 이어진다고 판단된다. 하지만 그 값의 차이가 매우 적어 진단적으로 유의한 범위라고 볼 수 없다. 팔을 머리 위로 올리고 검사하는 자세가 어깨 및 팔에의 $^{18}F$-FDG섭취와 환자의 고통을 야기하게 된다는 점들을 종합하여 고려해 보았을 때, PET/CT검사 시에는 팔을 내리고 검사하는 것이 합리적이나, 환자의 상태 및 영상의 질적 측면을 고려하여 결정하여야 하겠다.

  • PDF

GEMINI PET/CT의 X-ray CT, $^{137}Cs$ 기반 511 keV 광자 감쇠계수의 정량적 차이 (Quantitative Differences between X-Ray CT-Based and $^{137}Cs$-Based Attenuation Correction in Philips Gemini PET/CT)

  • 김진수;이재성;이동수;박은경;김종효;김재일;이홍재;정준기;이명철
    • 대한핵의학회지
    • /
    • 제39권3호
    • /
    • pp.182-190
    • /
    • 2005
  • 목적: CT기반 감쇠보정 영상의 표준섭취계수(Standard Uptake Value:SUV)가 $^{137}Cs$ 기반 감쇠보정 영상의 SUV보다 높다. 이 연구에서는 이러한 오차가 생기는 원인을 밝히고자 감쇠계수가 정확하게 변환되었는지 여부를 관심영역 분석을 통하여 평가하였다. 대상 및 방법: Philips GEMINI PET/CT는 X-ray CT (평균 40 keV) 혹은 $^{137}Cs$ (662 keV) 투과영상을 감쇠보정에 이용하는데 GEMINI PET/CT에서 사용하는 각각 선원의 에너지는 511 keV에서 얻은 감쇠계수와 틀리기 때문에 스캐너 내부에 장착된 감쇠계수 변환 알고리즘을 이용하여 511 keV에 해당하는 감쇠계수 값으로 변환된 감쇠지도를 사용하므로 감쇠계수의 변환이 정확하게 이루어졌는지 평가하는 것이 중요하다. 각각의 실험과정은 다음과 같다. 먼저 시스템 성능평가 팬텀 CT 투과 영상을 사용하여 Hounsfield units (HU)값을 측정하였다. 다음으로 NEMA 타원형 ECT 팬텀의 CT, $^{137}Cs$ 투과영상을 얻어 $^{68}Ge$ 투과선원을 장착한 Siemens ECAT EXACT 47 PET 스캐너에서 얻은 팬텀 투과 영상과 비교하여 감쇠계수가 511 keV에 해당하는 감쇠계수로 잘 변환되었는지 측정하였고 Gammex 467 electron density CT 팬텀의 CT, $^{137}Cs$ 투과영상에서 관심영역 분석을 하여 다양한 전자밀도 값에 대한 감쇠계수 변환의 정확성을 평가하였다. 또, 재구성한 영상에 미치는 영향을 평가하기 위하여 정상 및 병적 조직에서 CT, $^{137}Cs$ 기반 감쇠계수와 표준섭취계수를 비교하였다. 결과: CT에서 측정한 HU는 신뢰할 수 있는 값임을 확인하였으나 전자밀도와 원자번호가 큰 영역에서 CT 기반 감쇠계수에 오차가 있었는데 NEMA 타원형 ECT 팬텀 실험결과에 의하면 뼈 영역에서 오차는 11%이었다. 임상데이터에서도 마찬가지로 CT를 이용하여 얻은 감쇠계수가 $^{137}Cs$을 이용하여 얻은 감쇠계수보다 낮았고 전자밀도와 원자번호가 큰 영역에서 오차가 컸다. 그러나, 표준섭취계수는 $^{137}Cs$를 사용하여 감쇠보정을 한 영상의 값이 CT를 이용하여 감쇠보정을 한 값보다 오히려 낮았고 표준섭취계수의 백분율 차이는 $6.6{\sim}52.7%$이었다. 결론: CT의 HU가 정확함에도 불구하고 뼈 영역에서 CT 투과영상을 기반으로 한 감쇠계수의 변환이 부정확하고 CT 및 $^{137}Cs$ 투과영상을 기반으로 얻은 표준 섭취계수에 차이가 있으므로 이에 관한 추가적인 연구가 필요할 것으로 생각한다.

소방안전경영시스템 구축을 위한 실태평가에 관한 연구 (A Study on Real Condition Estimation for Fire Protection Safety Management System Builds)

  • 강길수;최재욱
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.18-24
    • /
    • 2013
  • 대형화, 다양화되고 있는 화재 폭발사고 및 지구온난화와 자연현상에 의한 재난으로부터 인명과 재산손실을 예방하기 위해 정부와 기업은 많은 노력을 기울이고 있다. 그러나 국가의 성장과 더불어 국민의 삶의 질 향상 및 복지증진이라는 국가의 거시적 목표에 부응하되 기업목적인 이윤추구의 달성을 위해 우선시된 경제정책 속에서 앞만 보고 달려온 기업들은 미온적 위험관리의 결과로 소중한 인명과 재산손실을 감내하고 있다. 2007년 소방방재청의 '안전문화 활성화를 위한 국민안전의식조사'에서 국민이 생각하는 우리 사회의 안전불감증은 '심각한 수준'으로 조사된 바, 본 연구에서는 소방안전사고예방과 안전의식수준향상을 위해 위험관리가 가능한 대기업뿐만 아니라 조직과 예산규모가 작아 사고발생의 위험이 큰 중소기업의 현 실태를 평가, 체계적인 안전관리를 통한 소방안전사고예방을 위해 현 실정에 맞는 '단계별 소방안전경영시스템' 구축에 대한 필요성을 조사하였다.

최적화 기법을 이용한 이산화탄소 소화설비의 설계프로그램 개발에 관한 연구 (A Study on the Design Program Development of the Carbon Dioxide Fire Extinguishing System Using an Optimization)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제28권3호
    • /
    • pp.1-9
    • /
    • 2014
  • 본 연구에서는 이산화탄소 소화설비의 설계이론, 소방방재청 고시 제2012-11호, KS B 6261과 최적화 기법 중 최대 경사법을 바탕으로 이산화탄소 소화설비의 설계인자를 최적화할 수 있는 설계프로그램을 개발하였다. 설계프로그램은 정립된 로직 및 알고리즘을 바탕으로 C++ 컴파일러를 이용하여 개발하였고 윈도우 운영체계에서 운영되도록 하였다. 이산화탄소 소화설비 설계인자의 최적화는 제한조건으로 구속되어있는 약제유동율, 방출시간 및 설계변수(배관내경 등)를 최소화하였다. 시험장치에 의해 설계프로그램의 성능을 검증하였고, 소방분야에 최적설계의 기틀을 마련하였다. 또한 최적설계인자를 바탕으로 이산화탄소 소화설비를 시공함으로서 소화설비의 효율성을 높이고 화재진압을 극대화할 것으로 본다.

NMEA 2000 범용 게이트웨이 설계 및 구현 (Design and Implementation of NMEA 2000 Based Universal Gateway)

  • 김기영;신수용;배광수;채석
    • 한국통신학회논문지
    • /
    • 제39C권2호
    • /
    • pp.191-198
    • /
    • 2014
  • NMEA(National Marine Electronic Association) 2000은 선박에서 사용되는 다양한 데이터(위치정보, 엔진 상태 등)들을 다른 전자장비에 통신하기 위한 규격으로, 이 선박 네트워크를 기반으로 한 범용 게이트웨이를 구현하였다. 이를 위해 NMEA 2000 Stack(ssJ1939) source와 CAN device driver source를 다양한 통신프로토콜을 사용할 수 있는 보드에 포팅하고 CAN, RS232, USB, Ethernet port를 갖추고 있는 이 보드에 연결하였다. 개발한 게이트웨이에서 변환된 선박 데이터의 검증을 위해, PC 기반의 시뮬레이터 프로그램과 모니터링 프로그램을 이 보드에 연결하여 NMEA 2000 network를 통해 선박의 데이터를 볼 수 있게끔 구성하였다. PC의 시뮬레이터 프로그램에서 생성된 선박 데이터정보를 게이트웨이와 NMEA 2000 network를 통해 모니터링 프로그램에서 분석하고 게이트웨이의 성능을 검증하였다. 기존의 게이트웨이가 주로 단일의 특정한 통신 프로토콜을 지원하는 것에 대비하여 Wi-Fi, Ethernet, Bluetooth, USB, RS232 등 다양한 통신 프로토콜을 지원함으로써 사용자가 원하는 통신방식을 이용하여 원격에서 데이터를 모니터링 하도록 설계하고 구현하였다.