고속응답 $CO_2$ 분석기의 제작 및 이를 이용한 SI 엔진에서의 실시간 배기가스 분석에 관한 연구 (Development of Fast-Response $CO_2$ Analyzer and Analysis of Engine-out Emission during Transient Condition of SI engine)

  • 송현수;민경덕
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3079-3084
    • /
    • 2008
  • A fast response $CO_2$ analyzer has been developed for measuring the $CO_2$ concentration during transient condition of SI engine. The analyzer is based on the non-dispersive infrared absorption technique, electrical chopping system and water cooling system. The analyzer has good repeatability, linearity and permissible drift characteristic. Besides, it has 18ms with a response to measure the $CO_2$ concentration. The fast response $CO_2$ analyzer was applied to single cylinder SI engine and the $CO_2$ emission was examined during engine start. Simultaneously, the standard exhaust gas analyzer, which has slow response time, was used for considering the engine-out $CO_2$ characteristic. The developed analyzer showed much faster responsive characteristic than that of a standard analyzer and made cycle by cycle exhaust gas analysis possible. The transient engine operating characteristics will be estimated and the transient behaviors on engine-out emission and performance will be improved.

  • PDF

탄산수의 알칼리도 및 총 탄소 측정방법 비교 연구 (A Comparison Study of Alkalinity and Total Carbon Measurements in $CO_2$-rich Water)

  • 조민기;채기탁;고동찬;유용재;최병영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제14권3호
    • /
    • pp.1-13
    • /
    • 2009
  • 탄산수를 대상으로 알칼리도 및 총 탄소 측정 방법의 타당성을 평가하기 위하여 산중화 적정법, 역적정법, 침전법, NDIR-TC 측정법 등 다양한 측정방법을 적용하였다. 인공적으로 제조한 탄산수(ACW(Artificial $CO_2$-rich Water): pH = 6.3, alkalinity = 68.8 meq/L, $HCO_3^-$ = 2,235 mg/L)의 알칼리도 및 총 탄소를 측정한 결과, 탄산수 제조와 동시에 측정된 시료에서는 상기한 모든 측정방법에서 비교적 정확한 측정값을 얻어내었다. 이때 퍼센트 오차는 0~12% 수준이었으며, 반복측정 분산분석(repeated measure ANOVA)의 사후 분석 결과 각 측정 방법간 차이는 95% 신뢰수준에서 없는 것으로 판정되었다. 또한 이때 정밀도(분산계수)도 4% 이내로 재현성이 높은 측정 방법이라고 할 수 있다. 탄산수와 같이 $CO_2$가 탈기(脫氣: degassing)되는 경우 각 측정 방법의 정도관리를 위하여 24시간, 48시간 동안 $CO_2$를 탈기시킨 후 각 측정 방법을 적용하였다. 그 결과 산중화 적정법과 NDIR-TC 방법으로 측정된 알칼리도는 $CO_2$의 탈기에 상관없이 일정한 값을 유지하고 있었다. 이는 알칼리도의 보존성에 기인한 결과로 해석된다. 반면, 역적정법과 침전법으로부터 구한 알칼리도는 증가하는 것으로 나타났다. 한편 총 탄소 함량은 꾸준히 감소하여 48시간후에는 최대 약 50%의 $CO_2$가 탈기된 것으로 평가되었다. 역적정법과 침전법으로부터 구한 알칼리도가 높아진 이유는 총 탄소 함량이 다른 방법에 비하여 높게 측정되었고, $CO_2$ 탈기를 모델링 한 결과, 측정된 총 탄소 함량에 평형인 pH보다 측정된 pH가 높기 때문이다. 이는 ACW에 잔류한 $CO_2$ 기포의 영향으로 생각된다. $CO_2$ 탈기에 의해 발생한 $CO_2$ 기포는 pH를 낮추지 못하고 알칼리도에 영향을 주지는 않기 때문에 산중화 적정법과 NDIR-TC 측정에서는 분석되지 않지만 역적정과 침전법을 적용하여 총 탄소를 분석할 경우에는 측정값에 포함된다. 따라서 탄산수에서 알칼리도 및 총 탄소의 측정과 해석을 정확하게 하기 위해서는 역적정법이나 침전법을 이용하여 측정한 결과를 비교 검토하는 것이 필요하다. 이 연구의 결과는 탄산수 연구나 $CO_2$ 지중저장에 관련된 연구에 활용될 수 있다. 특히 $CO_2$ 지중저장 연구에 응용될 경우 탈기되지 않는 $CO_2$ 기포의 함량을 반영할 수 있기 때문에 심부 지중의 pH를 보정하거나 $CO_2$의 지중 거동과 $CO_2$ 저장 용량 평가에 응용될 것으로 기대된다. 이 연구를 기반으로 고온 고압 환경에서 직접 총 탄소를 정확하고 편리하게 측정하기 위한 방법을 개발할 예정이다.

광학적 가스센서 특성 향상을 위한 광 공동 구조의 고찰 (Speculation of Optical Cavity for Improving Optical Gas Sensor's Characteristics)

  • 이승환;박종선
    • 한국가스학회지
    • /
    • 제12권4호
    • /
    • pp.63-68
    • /
    • 2008
  • 본 논문은 적외선 센서의 광 강도 및 효율을 증가시키기 위해 새로운 오목한 반사 벽면(curved mirror surface)과 기존의 수직 반사 벽면(vertical mirror surface)구조와의 모의해석 및 실험 결과에 대해 기술하였다. 모의해석 결과 수직 반사 벽면을 사용했을 때 적외선 센서 필터 표면에 도달하는 광의 분포는 타원 형상으로 적외선 센서 표면에 도달함을 볼 수 있고, 오목한 반사 벽면을 사용하는 경우에는 광이 원형상으로 집광되는 것을 볼 수 있었다. 따라서 초기 평행광의 면적보다 작은 면적으로 집광됨으로 인해 단위면적당 광 강도는 향상되고, 이에 따라 광학적 센서의 출력전압은 향상될 것이라 예측되었다. 이 모의해석을 근간으로 하여 $25^{\circ}C$, 45%R.H.에서 이산화탄소를 0 ppm에서 2500 ppm까지 250 ppm 간격으로 주입시켰을 때, 오목한 반사 벽면의 광 공동이 수직 반사 벽면의 광 공동보다 출력전압이 약 200 mV 증가하였다.

  • PDF

유제품 가공산업의 폐수처리시설로부터 발생되는 온실가스 배출 특성 (Characteristics of GHGs Emissions from Wastewater Treatment Process of Dairy Industry)

  • 김지혜;오민희;김지효;강성민;정재헌;사재환;전의찬
    • 한국기후변화학회지
    • /
    • 제7권2호
    • /
    • pp.103-110
    • /
    • 2016
  • In this study, we researched the characteristics of $CH_4$ and $N_2O$ emission of the wastewater treatment (WWT) process in the dairy industry. For flux measurements at the air-water interface, a floating dynamic flow-through chamber was used above the water surface. $CH_4$ and $N_2O$ concentration from the WWT process was measured by NDIR (Non-Dispersive Infrared) Analyser. In the study, $CH_4$ and $N_2O$ fluxes results showed a distinct difference for each WWT process. 60% of the GHG emissions which was the highest percentage were from the equalization tank. Reactor tank was second with 27% of the total emissions from the WWT. Aeration tank was third with 12% of the total emissions. The tendency was that the more the wastewater was treated, the less GHGs were emitted. $CH_4$ and $N_2O$ showed the same tendency. This indicates that the concentrations and properties of wastewater could affect the tendency.

도시고형폐기물 소각시설의 N2O 배출계수 개발 (The Development of N2O Emission Factor at Municipal Solid Waste Incinerator)

  • 고재철;최상현
    • 청정기술
    • /
    • 제25권1호
    • /
    • pp.40-45
    • /
    • 2019
  • 본 연구에서는 도시고형폐기물 소각시설을 대상으로 2018년 8월 27일부터 2018년 10월 22일 동안 총 3회에 걸쳐 도시고형폐기물의 소각에 의해 발생되는 $N_2O$ 농도를 24시간 동안 연속적으로 측정하여 발생량과 배출특성을 조사하였으며, 배출가스 중 $N_2O$ 농도측정은 비분산 적외선 분석기(NDIR)를 이용하였다. $N_2O$ 배출특성을 조사한 결과 도시고형폐기물 소각시설의 $N_2O$ 발생량 및 발생농도는 폐기물의 성상 보다는 소각시설의 소각로 온도와 산소농도 같은 운전조건에 따라 상이하게 발생하는 것으로 판단된다. 도시고형폐기물 소각시설의 $N_2O$ 일일평균 발생농도는 53.6 ~ 59.5 ppm이며, 전체 평균농도는 55.6 ppm으로 측정되었다. 또한 $N_2O$ 농도를 이용하여 계산된 $N_2O$ 발생량은 $90.41{\sim}108.44kg\;day^{-1}$이며, 평균 발생량은 $98.05kg\;day^{-1}$로 조사되었다. 이러한 결과를 바탕으로 도시고형폐기물 소각시설의 $N_2O$ 배출계수를 산출한 결과 $1,066.13g_{N_2O}\;ton_{waste^{-1}}$로 생활폐기물의 Tier 2 방법으로 산출된 $N_2O$ 배출계수에 비해 약 20배 정도 높은 결과를 얻었다. 따라서, 폐기물 종류와 소각량을 이용한 폐기물 소각시설의 $N_2O$ 발생량 산출방식은 정확성에 대한 보완이 필요할 것으로 판단된다.

급여수준에 따른 한우 암소의 온실가스 배출량 평가 (Evaluation on the Greenhouse Gas Emission According to the Intake Levels of Total Mixed Rations of Hanwoo Cow)

  • 김두리;하재정;김종택;송영한
    • Journal of Animal Science and Technology
    • /
    • 제53권5호
    • /
    • pp.475-480
    • /
    • 2011
  • 최근 온실가스 감축에 관한 국제적인 관심이 대두되면서 반추가축의 가스발생을 조절하기 위한 연구가 다양하게 시도되고 있다. 본 실험은 섬유질배합사료를 TDN의 유지수준과 섭취수준별 가스 발생량의 증가 정도 및 절식시 감소량을 측정함으로써 반추위내 장내발효에 의한 호흡가스의 정확한 산출근거를 구명하고자 실시하였다. 실험은 43개월 령의 평균체중 $372{\pm}11.2$ kg의 Fistula가 장착된 한우 암소를 공시하여 한우사양표준(2007)에 의거하여 TDN (kg)유지수준의 성장, 200 g/일 및 400 g/일 증체수준으로 TMR 사료를 각각 2회에 걸쳐 급여하였으며 물과 mineral block은 자유 섭식하도록 하였다. 온실가스 측정은 NDIR (Non-dispersive infrared absorption) 센서를 이용한 가스다중검출기를 이용하여 이산화탄소 및 메탄가스를 측정하였으며, 호흡챔버 내 환경온도는 $20^{\circ}C$를 유지하였다. 실험결과 급이 수준별 TDN가가 높을수록 가스발생량이 증가하는 경향을 나타내었으며, 이산화탄소 발생량에서는 유지수준에 비해 200 g/일에서 21.1%, 400 g/일에서 40.6% 수준으로 가스 발생량을 나타내었다. 메탄 발생량은 유지수준에 비해 200 g/일에서 33.5%, 400 g/일에서 69.6% 수준의 가스발생량을 나타내었다. 또한 절식 대사시 3일차부터 이산화탄소 발생량은 8%와 51% 수준으로 급격한 감소를 보였으며 메탄발생량은 각각 15%와 37%의 감소를 나타내었다. 위 결과는 향후 축산분야의 온실가스를 줄이기 위한 사양체계 및 절식대사를 통해 한우의 장내발효에 의한 가스발생조절에 대한 연구의 기초자료로 활용될 수 있을 것으로 판단된다.