• Title/Summary/Keyword: NDD-M

Search Result 12, Processing Time 0.022 seconds

Reductive stripping of Np using a n-butyraldehyde from a loaded TBP phase containing Np (Np 함유 TBP 유기상으로부터 NBA에 의한 Np의 환원 역추출)

  • Lee, Eil-Hee;Lim, Jae-Kwan;Chung, Dong-Yong;Yang, Han-Beom;Kim, Kwang-Wook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.163-170
    • /
    • 2008
  • The reductive stripping of Np using a n-butyraldehyde (NBA) from loaded organic solution containing Np, which was oxidative-extracted in a system of a 30 % TBP/NDD-2M $HNO_3$ and O/A=2 containing 0.005 M $K_2Cr_2O_7$ as an oxidant of Np, was studied. The stripping yields of Np was increased with an increasing the NBA concentration, with a decreasing the nitric acid concentration of stripping solution and with a decreasing the reaction temperature. The apparent reductive stripping rate equation was shown by the following equation : $-d[Np]_{Org.}/dt$ = 1,524 exp(-2,906/T) $[NBA]^{0.91}\;[H^+]^{-0.92}[Np]_{Org.}$. At 1.04 M NBA and 2 M $NHO_3$, the stripping yield of Np and U was 70.1 %, and 7.1 %, respectively, and the separation factor of U over Np ($=D_U/D_{Mp}$) was about 30.4. Therefore, it was found that U and Np co-extracted in a system of TBP-$HNO_3$ could be effectively mutual-separated by the NBA.

  • PDF

A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea (진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구)

  • Kim Youhyun;Choi Jonghak;Kim Sungsoo;Lee Chanhyeup;Cho Pyongkon;Lee Youngbae;Kim Chelmin
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA's guidance levels have been provided for western people to the end. Guidance levels lower than the IAEA'S will be necessary in view of Korean people's proportions. Therefore, we need to develope the standard doses for Korean people. And we conducted a nationwide survey of patient dose from x-ray examinations in Korea. In this study, the 278 institutions were selected from Members Book of Korean Hospital Association. The valid response rate was approximately 57.9%. Doses were calculated from the questionnaires by NDD method. We obtained the results were as follows; 1) General radiographic equipments were distributed for 42.0%, fluoroscopic equipments 29.4%, dental equipments 13.2%, CT units 8.1 % and mamographic units 7.2%. 2) According to classification by rectification, three-phase equipments were 29.9%, inverter-type generators 29.5%, single-phase equipments 25.5%, constant voltage units 9.0% and unknown units 6.0%. 3) According to classification by receptor system, film-screen types were 46.8%, CR types 26.8%, DR types 17.7% and unknown types 8.9%. 4) The number of examinations were chest 49.2%, spine 16.8% and abdomen 12.7%. 5) Patient doses were head AP 3.44 mGy, abdomen AP 4.25 mGy and chest PA 0.39 mGy.

  • PDF