• Title/Summary/Keyword: ND5

Search Result 4,313, Processing Time 0.038 seconds

A.C. Impedance Properties of HA/Ti Compound Layer coated Ti-30Ta-(3~15)Nb Alloys (Ti-30Ta-(3~15)Nb 합금에 HA/Ti 복합 코팅한 표면의 교류임피던스 특성)

  • Jeong, Y.H.;Lee, H.J.;Moong, Y.P;Park, G.H.;Jang, S.H.;Son, M.K.;Choe, H.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.5
    • /
    • pp.181-188
    • /
    • 2008
  • A.C. impedance properties of HA/Ti compound layer coated Ti-30Ta-($3{\sim}15$)Nb alloys have been studied by electrochemical method. Ti-30Ta binary alloys contained 3, 7, 10 and 15 wt% Nb were manufactured by the vacuum furnace system. And then specimen was homogenized at $1000^{\circ}C$ for 24 hrs. The sample was cut and polished for corrosion test and coating. It was coated with HA/Ti compound layer by magnetron sputter. The non-coated and coated morphology of Ti alloy were analyzed by X-ray diffractometer (XRD), energy X-ray dispersive spectroscopy (EDX) and filed emission scanning electron microscope (FE-SEM). The corrosion behaviors were investigated using A.C. impedance test (PARSTAT 2273, USA) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. Ti-30Ta-($3{\sim}15\;wt%$)Nb alloys showed the ${\alpha}+{\beta}$ phase, and $\beta$ phase peak was predominantly appeared in the case of increasingly Nb contents. The microstructures of Ti alloy were transformed from needle-like structure to equiaxed structure as Nb content increased. From the analysis of coating surface, HA/Ti composite surface uniformed coating layer with 750 nm thickness. The growth directions of film were (211), (112), (300) and (202) for HA/Ti composite coating on the surface after heat treatment at $550^{\circ}C$, whereas, the growth direction of film was (110) for Ti coating. The polarization resistance ($R_p$) of HA/Ti composite coated Ti-alloys were higher than those of the Ti and HA coated samples in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. Especially, corrosion resistance of Ti-Ta-Nb system increased as Nb content increased.

Magnetic Properties and the Crystallization of Amorphous Nd-Fe-Ti-B (Nd-Fe-Ti-B 비정질 합금의 자기적 성질 연구)

  • 이승화;안성용;김철성;김윤배;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.3
    • /
    • pp.140-145
    • /
    • 1997
  • The amorphous state of $NdFe_{10.7}TiB_{0.3}$ and its nanocrystallization have been studied by X-ray diffraction, 모스바우어 spectroscopy, and a vibrating sample magnetometer (VSM), $NdFe_{10.7}TiB_{0.3}$ amorphous ribbons were fabricated by a sigle-roll melt-spinning method. The average hyperfine field $H_{hf}$(T) of the amorphous state shows a temperature dependence of $[H_{hf}(T)-H_{hf}(0)]/H_{hf}(0)=-0.46(T/T_c)^{3/2}-0.34(T/T_c)^{5/2}$ for $T/T_c<0.7$ indicative of spin wave excitation. The quadrupole splitting just above the Curie temperature $T_c$ is 0.46 mm/s, whereas the average quadrupole shift below $T_c$ is zero. The Curie and crystallization temperatures are determined to be $T_c$=380K and $T_x=490K$, respectively, for a heating rate of 5 K/min. The occupied area of nanocrystalline phase at around 770K is about 65%. Above the Curie temperature, VSM data show magnetic moments increases again. The formation of $\alpha$-Fe is the main reason for the increasing moment as conformed with the 모스바우어 measurements.

  • PDF

A STUDY OF THE STRESS DISTRIBUTION ON THE SECOND ABUTMENT AND SUPPORTING TISSUES IN FIXED PARTIAL DENTURE USING THREE DIMENSIONAL FINITE ELEMENT ANALYSIS METHOD (고정성 가공의치에서 이차 지대치에 발생하는 응력의 삼차원 유한요소법적 분석)

  • Kim, Jeong-Hee;Jo, Kwang-Hun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.675-694
    • /
    • 2000
  • The purpose of this study was to investigate the displacement of and the stress distribution on the prosthesis, abutment, and its supporting tissues under functional load, and the effect of alteration in root length of 2nd abutment. The 3-dimensional finite element method was used and the finite element models were prepared in which the abutments of left mandibular 5 unit axed partial denture were canine, the 1st pre-molar and the 2nd molar, and the root lengths of canines were as follows. Model I : Root length of canine was 2mm longer than the 1st premolar Model II : Root length of canine was 2mm shorter than the 1st premolar Static compressive force of 300N was applied to connector between 2nd premolar & 1st molar, and then von Mises stress, displacement and reaction force were obtained. The results were as follows : 1. In fixed partial denture, prosthesis under load on pontic was rotated around mesio-distal long axis of it from longual side to buccal, and simultaneously bended in buccal and gingival direction with mesial end deformed in gingival direction and distolingual end in occlusal. 2. Clinical crowns of abutments were bended in the same directions with those in which prosthesis deforms. Due to that, roots of anterior abutments were twisted in counterclockwise with concentration of shear stress on distal or distobuccal sides of their cervices, and that of posterior was in clockwise with concentration of shear stress on mesiobuccal side of it in the same level with anterior abutments. 3. In case that root length of the 2nd abutment was longer than that of the 1st abutment, its displacement and reaction force which means the force tooth exerts on the surrounding periodontal tissues were smaller but shear stress on itself was larger than in the case root length of 2nd abutment was shorter.

  • PDF

AN EFFECT OF Nd : VAG LASER IRRADIATION ON THE MICROHARDNESS OF ROOT SURFACE (Nd : YAG layer 조사가 치근면의 미세경도에 미치는 영향)

  • Ahn, Jae-Hyeun;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.614-622
    • /
    • 1995
  • Root caries is very frequently developed on exposed root surface after periodontal surgical treatment. In order to determine the anti-caries effect of Nd : YAG laser irradiation on periodontally exposed root surface, 40 mandibular molar teeth that had been extracted due to excessive periodontal destruction were used as the experimental teeth. All teeth were treated by the same procedure as conventional periodontal root treatment, ie thorough scaling, root planing and root conditioning with tetracycline HCl(100mg/ml, 5min.). Within middle one third of root, mesial half surface(20) or distal half surface(20) was randomly irradiated at various power of 1.0W, 2.0W, 3.0W and 4.0W for 60 seconds by non-contact(5mm) delivery of a pulsed Nd : YAG laser(EN.EL.EN060, Italy). The microhardness was measured by Vikers microhardness tester(Wilson, USA) at 2mm/second of jog speed under 100gm load. The difference of microhardness between irradiated side and non-irradiated side was statistically analyzed ANOVA and Duncan's method. Following results were obtained ; 1. The microhardness(Knoop hardness number) was significantly higher in laser irradiated surface than non-irradiated surface(p<0.05). 2. There was no significant difference in microhardness between experimental groups classified by different laser power(p>0.1). The results suggest that Nd : YAG laser irradiation on exposed root suface after periodontal therapy may inhibit the root caries development by enhancing surface microhardness.

  • PDF

ITO, PR, 격벽 재료의 레이저 직접 미세가공

  • Lee, Cheon;Lee, Gyung-Chul;Ahn, Min-Young;Lee, Hong-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.80-80
    • /
    • 1999
  • 플라즈마 디스플레이 패널(PDP)의 공정을 간단히 하기 위하여 포토레지스트, ITO, 격벽재료를 Ar+ laser(λ-514 nm, CW)와 Nd:YAG laser(λ=532, 266nm, pulse)로 직접 패터닝 하였다. 레이저에 의한 포토레지스트의 패턴결과, 아르곤 이온 레이저의 포토레지스트 가공의 반응 메카니즘은 레이저 빔의 열에 의한 시료 표면의 국부적인 온도상승에 의한 용융작용이며, 그 결과 식각 후 형성된 패턴의 단면 모양도 레이저빔의 profile과 같은 가우시안 형태를 나타낸다. Nd:YAG 레이저의 4고조파(532nm)를 이용한 경우 200$\mu\textrm{m}$/sce의 주사속도에서 포토레지스트를 패턴하기 위한 임계에너지(threshold energy fluence) 값은 25J/cm2이며, 약 40J/cm2의 에너지 밀도에서 하부기판의 손상이 발생하기 시작하였다. 글미 1은 Nd:YAG 레이저 4고조파를 이용하여 포토레지스트를 식각한 경우 SEM 표면사진(위)과 단차특정기에 의한 단면형상(아래)이다. ITO 막의 레이저에 의한 직접 패턴 결과, ITO 막은 레이저 펄스에 의한 급속 가열 및 증발에 의한 메커니즘으로 식각이 이루어지며, 레이저 파장에 따른 광흡수 정도의 차이에 의해 2고조파 (532nm)에서 ITO 막의 가공 품질이 4고조파(266nm)에 비해 우수하며 패턴의 폭도 출력에 따라 제어가 용이하였다. 그림 2는 Nd:YAG 레이저 2고조파를 이용하여 ITO를 식각한 경우 SEM표면 사진(위)과 단차측정기에 의한 단면형상(아래)이다. 격벽 재료의 레이저에 의한 직접 패턴 결과, Ar+ 레이저(514nm)는 출력 밀도 32NW/cm2에서 격벽을 유리 기판의 경계면까지 식각하였다. Nd:YAG 레이저(532nm)는 laser fluence가 6.5mJ/cm2에서 격벽을 식각하기 시작하였으며, 19.5J/cm2에서 유리기판의 rudraus(격벽 두께 130$\mu\textrm{m}$)까지 식각하였다.

  • PDF

Etching characteristics of Al-Nd alloy thin films using magnetized inductively coupled plasma

  • Lee, Y.J.;Han, H.R.;Yeom, G.Y.
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.56-56
    • /
    • 1999
  • For advanced TFT-LCD manufacturing processes, dry etching of thin-film layers(a-Si, $SiN_x$, SID & gate electrodes, ITO etc.) is increasingly preferred instead of conventional wet etching processes. To dry etch Al gate electrode which is advantageous for reducing propagation delay time of scan signals, high etch rate, slope angle control, and etch uniformity are required. For the Al gate electrode, some metals such as Ti and Nd are added in Al to prevent hillocks during post-annealing processes in addition to gaining low-resistivity($<10u{\Omega}{\cdot}cm$), high performance to heat tolerance and corrosion tolerance of Al thin films. In the case of AI-Nd alloy films, however, low etch rate and poor selectivity over photoresist are remained as a problem. In this study, to enhance the etch rates together with etch uniformity of AI-Nd alloys, magnetized inductively coupled plasma(MICP) have been used instead of conventional ICP and the effects of various magnets and processes conditions have been studied. MICP was consisted of fourteen pairs of permanent magnets arranged along the inside of chamber wall and also a Helmholtz type axial electromagnets was located outside the chamber. Gas combinations of $Cl_2,{\;}BCl_3$, and HBr were used with pressures between 5mTorr and 30mTorr, rf-bias voltages from -50Vto -200V, and inductive powers from 400W to 800W. In the case of $Cl_2/BCl_3$ plasma chemistry, the etch rate of AI-Nd films and etch selectivity over photoresist increased with $BCl_3$ rich etch chemistries for both with and without the magnets. The highest etch rate of $1,000{\AA}/min$, however, could be obtained with the magnets(both the multi-dipole magnets and the electromagnets). Under an optimized electromagnetic strength, etch uniformity of less than 5% also could be obtained under the above conditions.

  • PDF

Quality Characteristics of Jeung-Pyun According to the Leavening Agents (팽창제 종류에 따른 증편의 품질 특성)

  • An, Su-Mi;Lee, Kyung-A;Kim, Kyung-Ja
    • Korean Journal of Human Ecology
    • /
    • v.5 no.1
    • /
    • pp.48-61
    • /
    • 2002
  • This study was carried out to investigate the effects of four kinds of leavening agents on Jeung-Pyun fermantation. Milk-wine(M), fresh yeast(F), dry yeast(D), instant yeast(I) were used in Jeung-Pyun ingredients. The physicochemical properties, sensory evaluation were examined. The results of this study are summarized as follows: 1. Basic recipes for Jeung-Pyun by preliminary test were developed. 2. Specific volumes and expansion ratio of Jeung-Pyun was higher in the fresh yeast-added sample. 3. The pH of Jeung-Pyun was decreased significantly as the fermentation progressed 4. In the result comparing Jeung-Pyun extracting after 1st fermentation with Jeung-Pyun extracting 2nd fermentation by SEM, the former was widely distributed in stability of bubble and pore than the latter. 5. Standard recipe by Q.D.A. test added four kinds of leavening agents were as follows: (1)Jeung-Pyun added milk wine was 240min for 1st fermentation time, 60min for 2nd fermentation time, 35$^{\circ}C$ for fermentation temperature, 80% for fermentation humidity respectively. (2) Jeung-Pyun added fresh yeast was 90min for 1st fermentation time, 40min for 2nd fermentation time, 35$^{\circ}C$ for fermentation temperature, 80% for fermentation humidity respectively. (3)Jeung-Pyun added dry yeast was 90min for 1st fermentation time, 60min for 2nd fermentation time, 35$^{\circ}C$ for fermentation temperature, 60% for fermentation humidity respectively. (4)Jeung-Pyun added instant yeast was 90min for 1st fermentation time, 40min for 2nd fermentation time, 30$^{\circ}C$ for fermentation temperature, 60% for fermentation humidity respectively. 6.Based on sensory evaluation, Jeung-Pyun added fresh yeast was significantry higher than others in color, sweetness, moistness, softness, and overall quality. There was negative significance between milk wine flavor and astrigentness, and yeast flavor.

  • PDF

PERIODONTAL AND PROSTHETIC FINDINGS IN PATIENTS TREATED WITH REMOVABLE PARTIAL DENTURES OR DISTALLY EXTENDING CANTILEVER BRIDGES (가철성 국소의치와 후방연장 계속가공의치를 장착한 환자의 치주 및 보철 상태)

  • Kim, Jeong-Chan;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.635-645
    • /
    • 1993
  • This study was perfomed to investigate the prosthodontic and periodontal status of the abutment teeth in distally extending bridges(DEBs) (78 cases) and removable partial dentures(RPDs) (43 cases) for 122 patients (55 males and 57 females) visiting department of Periodontology, Seoul National University Hospital. The average wearing periods were 67.8 months for DEBs and 66.4 months for RPDs. 38.4% of the patients in DEBs and 35.9% in RPDs complainted of chewing discomfort and 22.6% and 24.4% were not chewing on the prosthodontically - treated sides, respectively. In DEBs, when the restoration for 2nd molar supported by 1st molar & 2nd premolar was grouped to type 1, 1st molar supported by 1st & 2nd premolars was type 2, and 1st & 2nd molars supported by 1st & 2nd premolars was type 3, there was a significant differences only in the tooth mobility score among clinical parameters (type 2>type 1>type 3). In RPDs, when bilateral free-end case was grouped to type 1, and unilateral case was type 2, there was a significant difference in the Gingival index (type 1>type 2). In DEBs, 62.8% of restoration were overcontoured, 72% had interproximal space closures, 30.5% overextended pontics and 86.6% overhanging margins. In RPDs, 24.4% of the restorations were overcontoured, 45.5% had interproxinal space closures and 58.3% overhanging margins. From these results of this study, periodontal problems caused by prosthodontic defects were considered to be contributing factors in chewing discomfort.

  • PDF

PHYSICAL MODIFICATION AND ABLATION THRESHOLDS OF DENTIN INDUCED BY ND : YAG, HO : YAG, AND ER : YAG LASERS (Nd : YAG, HO : YAG, Er : YAG 레이저 조사에 의한 상아질의 물리적 변형 및 절제(切除)역치에 관한 연구)

  • Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.4
    • /
    • pp.954-967
    • /
    • 1996
  • Laser application to modify healthy permanent dentin to improve microhardness and caries resistence has been previously reported but the physical modification and ablation thresholds of carious and sclerotic dentin has yet to be identified. This study determined the energy density required by modify (physical modification threshold, PMT) and remove (ablation threshold, AT) infected carious, affected and selerotic dentin compared to healthy permanent dentin. $1{\pm}0.25mm$ thick dentin sections(n=272) from extracted human teeth were used. Smear layer was removed 0.5M EDTA for 2 minutes. Utilizing three pulsed fiberopitc delivered contact lasers with different emission wavelengths($1.06{\mu}m$=Nd : YAG, $2.10{\mu}m$=Ho : YAG and $2.94{\mu}mEr$ : YAG). The energy density($J/cm^2$) was incrementally increased and the resulting tissue interaction classified on a scale from 0-6. A minimum of 5 repetitions/energy density were completed. Light microscopy(10-25X) was used to verify the physical modification(scale=3) and ablation thresholds(scale=4) of the various forms of dentin and the data were analyzed by logistic regression at the 95 % confidence interval. PMT and AT by the laser and the dentin types were: PMT and AT was lower in infected dentin than in sound dentin for all lasers. PMT and AT induced by Nd : YAG>Ho : YAG>Er : YAG for all forms of dentin. Microhardness was increased in sound dentin at PMT. Morphology of crater examined by light microscopy showed Nd : YAG was safe and effective for removing carious dentin and Er: YAG was effective for removing sound dentin. The PMT and AT for YAG lasers are different as a function of dentin type which may be utilized for selective modification and removal of dentin.

  • PDF