• Title/Summary/Keyword: ND5

Search Result 4,313, Processing Time 0.039 seconds

CASE REPORT OF DENTIGEROUS CYST OF MANDIBLE TREATE BY ENUCLEATION (하악골에 발생한 함치성양종의 치험예)

  • Choie, Mok-Kyun;Bae, Chang;Kim, Suck-Kyun
    • The Journal of the Korean dental association
    • /
    • v.16 no.11 s.114
    • /
    • pp.857-860
    • /
    • 1978
  • An instance of dentigerous cyst, 6×2.5×1.5cm, occurred in posterior region of the right mandible, originated from 3rd molar, involved the 2nd premolar, 1st and 2nd molar in a 38-year-old man was observed and surgical enucleation followed by careful excision of all cyst wall was successfully carried out, recovery and healing were rapid and uncomplicated.

  • PDF

Experimental Study of Laser Assisted Microvascular Anastomosis(LAMA) Using the Nd:YAG Contact Laser (Laser를 이용한 새로운 미세혈관 문합술의 실험적 연구)

  • Cho, Jin-Hwan;Lim, Jae-Ho;Park, Seung-Ha;Kim, Woo-Kyung
    • Archives of Reconstructive Microsurgery
    • /
    • v.2 no.1
    • /
    • pp.82-92
    • /
    • 1993
  • A comparative study was undertaken to evaluate the contact Neo-dymium : yttrium aluminum garnet(Nd:YAG) laser system for vascular anastomosis of small caliber blood vessels(diameter 0.5-1.2 mm) in the animal model. In this study 40 femoral arteries and 40 femoral veins of Sprague-Dawley rats were anastomosed by contact laser assisted microvascular anastomosis(LAMA) utilizing 3 stay sutures which were placed 120 degrees apart and the intervals welded with contact Nd:YAG laser unit, conventionally sutured anastomosis(CSA) served as controls. The time needed for vascular anastomosis, patency rate(immediate postoperative, postoperative 2nd day, postoperative 1 week, postoperative 4 weeks), gross and microscopic evaluations were compared to conventional microsurgical suture technique. The results are as follows: 1. Postoperative patency rate was 82.5% for femoral artery and 75% for femoral vein by contact LAMA technique compared to 90% and 75% by CSA technique at postoperative 4 weeks. 2. Less time-consumed for arterial anastomosis by 6 minutes 23 seconds and venous anastomosis by 8 minutes 55 seconds with contact LAMA technique compared to CSA technique. 3. Grossly almost complete healing had taken place by postoperative 1 week by contact LAMA technique. 4. Aneurysm formation was 5% for femoral artery and 15% for femoral vein by contact LAMA technique compared to 5% and 10% respectively by CSA technique. 5. Microscopically, re-endothelization was complete by postoperative 7th day by contact LAMA technique. There was less medial hypertrophy and hyperplasia and also less inflammatory response compared to CSA.

  • PDF

Properties of Phosphate Glasses - $BaO-Nd_{2}O_3-TiO_2$ Ceramic Composites for Using Dielectric Materials Having Low Temperature Cofired Ceramic(LTCC) (저온동시소성 유전체 재료용 인산염계 유리-$BaO-Nd_{2}O_3-TiO_2$계 세라믹 복합체의 특성)

  • Lee Hoi Kwan;Lee Yong Su;Hwang Sheng-Jian;Kang Won Ho;Kim Hyung Sun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.2 s.31
    • /
    • pp.17-22
    • /
    • 2004
  • In this study, BNT($BaO-Nd_{2}O_3-TiO_2$) and $70P_{2}O_5-5B_{2}O_3-(25-x)BaO-xNa_{2}O$ glass-ceramic composites were fabricated and investigated in order to apply for low temperature cofired ceramic. The prepared BNT based glass-ceramic composites were sintered at $800{\sim}950^{\circ}C$ with the glass fit contents ranging from 10 to $15\;wt\%$. The properties such as sintering and dielectric property were investigated in the ceramic compositions according to the phosphate glass frit. The dielectric constant was varied between 10 to 40 and shrinkage rate was increased according to increasing glass frit.

  • PDF

The Formation of the Shallow Junction by RTD and Characteristic Analysis for $n^+$ -p Diode with Ti-silicide (고속 열 확산에 의한 얕은 접합 형성과 Ti-실리시이드화된 $n^+$ -p 다이오드 특성 분석)

  • 최동영;이성욱;주정규;강명구;윤석범;오환술
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.8
    • /
    • pp.80-90
    • /
    • 1994
  • The ultra shallow junction was formed by 2-step RTP. Phosphorus solid source(P$_{2}O_{5}$) was transfered on wafer surface during RTG(Rapid Thermal Glass Transfer) of which process condition was 80$0^{\circ}C$ and 60sec. The process temperature and time of the RTD(Rapid Thermal Diffusion) were 950~105$0^{\circ}C$ during 5~15sec respectively sheet resistances were measured as 175~320$\Omega$/m and junction depth and dopth and dopant surface concentration were measured as 0.075~0.18$\mu$m and 5${\times}10^{19}cm^{4}$ respectively. Ti-silicide was formed by 2-step RTA after 300$\AA$ Titanium was deposited. The 1st RTA (2nd RTA) was carried out at the temperature of $600^{\circ}C$(700~80$0^{\circ}C$) for 30 seconds (10~60 seconds) under N$_2$ ambient. Sheet resistances after 2nd RTA were measured as 46~63$\Omega$/D. Si/Ti component ratio was evaulated as 1.6~1.9 from Auger depth profile. Ti-Silicided n-p junction diode (pattern size : 400$\times$400$\mu$m) was fabricated under the RTD(the process was carried out at the temperature of 100$0^{\circ}C$ for 10seconds) and 2nd RTA(theprocess was carried out at the temperature of 750$^{\circ}C$ for 60 seconds). Leakage current was measured 1.8${\times}10^{7}A/mm^{2}$ at 5V reverse voltage. Whent the RTD process condition is at the temperature of 100$0^{\circ}C$ for 10seconds and the 2nd RTA process condition is at the temperature of 75$0^{\circ}C$ for 60 seconds leakage current was 29.15${\times}10^{9}A$(at 5V).

  • PDF

The effect of Boa-tang to the lymphocytes (보아탕(補兒湯)이 림프구의 증식능(增殖能)에 미치는 영향(影響))

  • Im, Jae-Gook;Hong, Moo-Chang;Ha, Yoon-Moon
    • Journal of Oriental Physiology
    • /
    • v.14 no.2 s.20
    • /
    • pp.83-97
    • /
    • 1999
  • By inserting Boa-tang into culture median of lymphocytes from spleen of rat and lymphocytes in human peripheral blood The results were as follow. 1. In case of spleen lymphocytes of rat, cultures of lymphocytes did not significantly increased which were inserted Boa-tang $100{\mu}g/ml$, and which were inserted $10{\mu}g/ml$ at 3rd day 2. In case of spleen lymphocytes of rat, cultures of lymphocytes were significantly increased which were inserted Boa-tang $10{\mu}g/ml$ with Con A $2.5{\mu}g/ml$ at 2nd, 3rd day, and Boa-tang $1{\mu}g/ml$ with ConA $2.5{\mu}g/ml$ at 3rd day than inserted ConA $2.5{\mu}g/ml$ 3. In case of lymphocytes in human peripheral blood, cultures of lymphocytes were significantly increased which were inserted Boa-tang $100{\mu}g/ml$ and $10{\mu}g/ml$ at 2nd day to 5st day, and which were inserted Boa-tang $1000{\mu}g/ml$ at 2nd day to 5th day, and which were inserted $1{\mu}g/ml$ at 2nd day By looking at the following results, in case of rat cultures of lymphocytes were significantly increased which were inserted the lower density, but in case of human cultures of lymphocytes were significantly increased which were inserted the higher density.

  • PDF

Contents of Heavy Metals in Soybean Curd and Starch Jelly Consumed in Korea (국내 유통 두부류 및 묵류 중 중금속 함량)

  • Kim, Mee-Hye;Lee, Yun-Dong;Park, Hyo-Jung;Park, Sung-Kug;Lee, Jong-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.1-5
    • /
    • 2005
  • Contents of heavy metals [mercury (Hg), lead (Pb), cadmium (Cd), and arsenic (As)] in 218 samples including soybean curds (n = 138), processed bean curds (n = 37), starch jellies (n = 33), and mixed starch jellies (n = 10) were determined using mercury analyzer, atomic absorption spectrophotometer (AAS) or inductively coupled plasma spectrometer (ICP). Ranges and means of heavy metals in soybean curds and starch jellies were as follows [min-max (mean) values]: soybean curds -Hg $0.1-8.2(0.3)$, Pb not detectable (ND)-203.9(23.3),\ Cd ND-46.0 (8.1), and As ND-61.3 (0.7)${\mu}g/kg$, starch jellies-Hg 0.1-1.3(0.3)${\mu}g/kg$, Pb ND-90.2(22.4)${\mu}g/kg$, Cd ND-31.0(3.7) and As ND-23.6(1.1)${\mu}g/kg$. Daily intakes of Hg, Pb, and Cd from soybean curds and starch jellies were 0.001-0.3% of Provisional tolerable weekly intake established by FAO/WHO.

Study on the Difference of Pulse Waveform Parameter with Applied Variations of Pressure (측정가압에 의한 좌관부위(左關部位) 맥파요인 변화에 대한 실험 연구)

  • Kim, Gyeong-Cheol;Lee, Jeong-Won;Ryu, Kyeong-Ho;Kang, Hee-Jung;Yim, Yun-Kyoung
    • Korean Journal of Acupuncture
    • /
    • v.27 no.4
    • /
    • pp.59-72
    • /
    • 2010
  • Objectives : In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundaments of contemporary pulse diagnosis research, and to find the change of pulse waveform parameter with applied variation pf pressure. Methods : As we will to do experimental research on the difference of pulse waveform on the radial artery with applied variations of pressure(5 stage-pressure) and measuring position(left KWAN). In this research, we analyzed the change of the waveform according to five stage pressure. Results : The results were as follows; When we analyzed the change of the waveform according to pressure in the left KWAN, E, hl, h2 and A were the difference between 8ths pressure grades in 95% trust section. And t2, t4 were the difference between 8ths pressure grades in 95% trust section. W was the difference between 8ths pressure grades in 95% trust section. And h2/h1 was the difference between 6ths pressure grades in 95% trust section. There is the difference between 1st and 2nd grade & between 2nd and 5th grade in the case of t4/t2 in 95% trust section. And there is the difference between 1st and 5th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of W/A in 95% trust section. And there is the difference between 1st and 2nd grade, between 2nd and 3rd grade, between 2nd and 4th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of A/E in 95% trust section. Conclusions : We found the statistically resonable differences between each pulse depending on the applied pressure. And Analysing the radial pulse(left KWAN) at 5 applied pressure levels may be useful to study on the pulse waveform diagnosis.

The Effect of InGaAlP Laser Transcutaneous Blood Irradiation on Heart Rate Variability in Healthy Adults (InGaAlP 레이저 경피혈액조사가 정상성인의 심박변이도에 미치는 영향)

  • Lee, Tae-Ho;Yeo, Jin-Ju;Seol, Hyun;Jang, In-Soo
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.25-33
    • /
    • 2004
  • Objective : The effects of Indium-Gallium-Aluminium-Phosphide(InGaAlP) laser transcutaneous irradiation on heart rate variability(HRV) in healthy adults are investigated with power spectrum analysis(PSA) of HRV. Methods : The control group consisted of 20 healthy volunteers (10 men, 10 women). The experiment was divided into 5 different periods, the pre-1st laser period(10 minutes), the 1st laser period(30 minutes), the post-1st laser period(5 minutes), the 2nd laser period( 30 minutes) and the post-2nd laser period(30 minutes). HRV was measured for 5 minutes at the pre-1 st laser period, the post-l st laser period and the post-2nd laser period. The laser period is the period in which InGaAlP laser transcutaneous Irradiation treatment occurs. Results : 1. SDNN of volunteers at post-1st laser period and post-2nd laser period significantly increased compared with that of the pre- 1 st laser period. 2, Ln(VLF) at post-I st laser period significantly increased compared with that of pre-1st laser period, while Ln(HF) at post-2nd laser period significantly decreased compared with those of pre- I st laser period and post-1st laser period, 3. Ln(TP) at post-1st laser period and post-2nd laser period significantly increased compared with that of pre-1st laser period, 4, LF/HF Ratio at post-2nd laser period significantly increased compared with those of pre-1st laser period and post-1st laser period. But the other variables did not significantly change. Conclusions : The results suggest that InGaAlp laser transcutaneous Irradiation in healthy adults is associated with the autonomic nervous systems. Further study is needed for investigating the effects of laser irradiation on autonomic nervous systems.

  • PDF

Evaluation of Laser Welding Characteristics of 1.5GPa Grade Ultra High Strength Steel for Automotive Application (1.5GPa급 자동차용 고강도강의 레이저 용접부 특성평가)

  • Kim, Yong;Park, Ki-Young;Lee, Kyoung-Don;Jeong, Jun-Kou;Kim, Dong-Wha
    • Laser Solutions
    • /
    • v.13 no.4
    • /
    • pp.1-6
    • /
    • 2010
  • Recently the use of ultra high strength steels (UHSS) in structural and safety component is rapidly increasing in the automotive industry. For example, 1.5GPa grade hot stamping with die-quenching of boron steel 22MnB5 could apply crash-resistant parts such as bumpers and pillars. The development of laser welding process of hot stamping steels, fundamental bead-on-plate welding and lap joint welding test were carried out using 3kW Nd:YAG laser. Local hardening & HAZ softening occurred in hot stamping steel as a result of metallurgical change caused by the welding heat input in the Nd:YAG laser welding process. The size of soft zones in the hot stamping steel was related to the welding heat input, being smaller at high speeds which generated a smaller heat input. Also in the case of lap joint design structure, same welded characteristics were shown. The HAZ softening degree was controlled to ensure the joint strength.

  • PDF