• 제목/요약/키워드: ND5

검색결과 4,313건 처리시간 0.035초

고전압과 고주파수형 공진형 DC-DC 콘버터를 이용한 펄스형 Nd:YAG 레이저의 디지틸제어 구현 (The Digital Controlled Implementation of the Resonant DC-DC Converter with High Voltage, High Frequency For Pulsed Nd:YAG Laser)

  • Kim, Whi-Young
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 제14회 신호처리 합동 학술대회 논문집
    • /
    • pp.777-783
    • /
    • 2001
  • This paper is mainly concerned with the state of the practical developments of a constants PWM bridge type resonants DC-DC suitable converter for Nd:YAG Laser with a Microprocessor. (PIC16C54 & 8051) The use of IGBT power supply with feedback control of flashLamp currents imparts a advantages to Nd:YAG Laser for materials processing. these include the alility to tailor the pulseshape and modify pulse parameters on a pulse- by pulse basis. And Correct choice of pulseshape can enhance the repeatability of the process. as higher power IGBT became available, act ive pulseforming power supplies will find greater user in deep hole drilling machine By Using certain control tecniques, utililized in designing Pic16c54 from Microchip technology and Intel 8051, also Mornitoring from Microsoft Visual Basic 5, And it allowed us to designed and fabricate ahigh repel it ion rate and high power(HRHP) pulsed Nd:YAG laser system, As a result of that, the current pulsewidth could be contort led 200s to 350s(step 50s) , and the pulse repetition rate could be adjusted 500pps to 1150pps. In addition, in the case of one laser head consisting of a Nd:YAG laser rod and two flashlamps , the maximum laser output of 240w was produced at the condition of 350s and 1150pps, and that of about 480w was generated at the same condition when two laser heads were arranged in cascade.

  • PDF

치아 석회화과정과 골성숙단계의 상호연관성에 관한 연구 (A STUDY ON THE COMPARISONS BETWEEN DENTAL CALCIFICATION AND SKELETAL MATURITY)

  • 차대식;차경석
    • 대한치과교정학회지
    • /
    • 제24권4호
    • /
    • pp.841-849
    • /
    • 1994
  • This study was conducted on 342 patients(male 157, female 185)aged 8 to 15 years old, who visited Dankook University Dental Hospital. Pre-orthodontic treatment orthopantomograms were used to assess the dental calcification stages of mandibular 3rd molar, 2nd molar, 2nd premolar and 1st premolar by 8 stages.(by Demirjian) Hand-wrist radiogrms were used to evaluate the skeletal maturity in 11 stages.(by Fishman) Following results were obtained after investigating the correlationship between dental calcification and skeletal maturity 1. Chronologic age showed high correlation to dental calcification and skeletal maturity. 2. Dental calcification and skeletal maturity showed high correlation and no statistical difference was observed between male and female. 3. SMI stages 1 to 4 showed high statiscal significance to mandibular 2nd molar, 2nd premolar and 1st premolar. SMI stages 5 to 8 showed high stastical significance to mandibular 2nd molar, 2nd premolar. SMI stages 9 to 11 showed high statistical significance to mandibular 3rd molar.

  • PDF

Two Cases of Primary Splenic Hydatid Cyst in Greece

  • Vezakis, Antonios;Dellaportas, Dionysios;Polymeneas, George;Tasoulis, Marios Konstantinos;Chondrogiannis, Constantinos;Melemeni, Aikaterini;Polydorou, Andreas;Fragulidis, George Panagiotis
    • Parasites, Hosts and Diseases
    • /
    • 제50권2호
    • /
    • pp.147-150
    • /
    • 2012
  • Cystic disease of the spleen is an uncommon entity in general population. Most cases result from parasitic infection by Echinococcus granulosus, a form called splenic hydatid disease (SHD), with a reported frequency of 0.5-6.0% within abdominal hydatidosis. On the contrary, an isolated splenic involvement of hydatid disease is very uncommon even in endemic regions. Two cases of primary SHD managed with open and laparoscopic radical surgery in our department are reported herein. Primary SHD is a rare entity with non-specific symptoms underlying clinical suspicion by the physician for prompt diagnosis. Surgical treatment is the mainstay therapy, while laparoscopic approach when feasible is safe, offering the advantages of laparoscopic surgery.

A Metallurgical Study on Sputtered thin Film Magnet of high $_{i}\textrm{H}_{c}$ Nd-(Fe, Co)-B alloy and Magnetic

  • Kang, Ki-Won;Kim, Jin-Ku;Song, Jin-Tae
    • 한국재료학회지
    • /
    • 제4권5호
    • /
    • pp.535-540
    • /
    • 1994
  • Thin film magnet was fabricated by radio frequency magnetron sputtering using $Nd_13/(Fe.Co)_{70}B_{17}$ alloy target and magnetic properties were investigated according to sputtering conditions from the metallurgical point of view. we could obtain the best preferred orientation of $Nd_2Fe_{14}B$ phase at substrate temperatures between $450^{\circ}C$ and $460^{\circ}C$ with the input power 150W, and thin films had the anisotropic magnetic properties. But, as the thickness of thin film increased, the c-axis orientation gradually tended to be disordered and magnetic properties also become isotropic. Just like Nd-Fe-B meltspun ribbon, the microstructure of thin film magnet was consisted of very find cell shaped $Nd_2Fe_{14}B$ phase and the second phase along grain boundary. While, domain structure showed maze patterns whose magnetic easy axis was was perpendicular to film plane of thin film. It was concluded from these results that the perpendicualr anisotropy in magnetization was attributed to the perpendicular alignment of very find $Nd_2Fe_{14}B$ grains in thin film.

  • PDF

강유전체 박막과 마이크로 가공 기술을 이용한 초전형 적외선 센서의 제작 (Pyroelectric Infrared Microsensors Made by Micromachining Technology)

  • 최준림;이돈희;남효진;조성문;이주행;김광영;김성태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.66-68
    • /
    • 1994
  • 강유전체 박막과 마이크로 가공기술을 이용하여 초전형 적외선 센서를 제작하였다. 초전형 적외선 센서는 $Pb_{1-x}La_xTi_{1-x/4}O_3$ (x=0.05) (PLT) 강유전체 박막 커패시터를 RF 마그네트론 스퍼터링 방식으로 백금 전극이 증착된 MgO 기판상에 결정 성장시킨 구조를 갖고 있다. 스퍼터링된 PLT 바닥은 높은 c-축 결정 구조를 가지므로 센서로 사용하기 위한 poling 처리 과정이 필요하다. 이는 적외선 이미지 센서를 구현함에 있어서 수율 향상에 필수적인 요소이다. 마이크로 가공 기술을 사용하여 센서의 열용량을 극소화 함으로서 센서의 효율을 최대화하였다. 제작된 센서의 상부에 폴리이미드를 코팅하고 MgO 기판을 선택적으로 식각하여 코팅된 폴리이미드가 강유전체 박막 커패시터를 지지하고 있는 구조를 구현하였다. 이렇게 제작된 센서의 감도는 상온에서 $8.5{\times}10^8cm{\cdot}{\sqrt}{Hz/W}$로 측정되었으며 이는 마이크로 가공 기술을 사공하지 않은 경우보다 약 100 때의 감도 향상을 가져왔다.

  • PDF

Study on the Rigidity of the Solid-HDDR Treated Nd-Fe-B-type Materials

  • Kang, S.J.;Kwon, H.W.
    • Journal of Magnetics
    • /
    • 제3권1호
    • /
    • pp.9-14
    • /
    • 1998
  • A non-coercive cast Nd-Fe-B-type material can be easily converted into a coercive one by employing HDDR process. Applying the conventional HDDR process to the Nd-Fe-B-type material generally leads to a powder-like material. HDDR treated material in a solid form can, however, be realised if the process is properly modified (solid-HDDR). In the present study, the change of rigidity (compressive strength) of the Nd-Fe-B-type material during the solid-HDDR has been investigated using a homogeneous sintered magnet with composition $Nd_{13.8}Dy_{0.7}Fe_{78.25}Si_{0.15}Mn_{0.6}B_{6.5}.$ It has been found that the low strength of the hydrided material was improved by the subsequent disproportionation. The restoration of the strength was explained by the eutectoid-like disproportionation structure containing fine neodymium hydride rod embedded in tough iron matrix. The high strength of disproportionated material was reduced radically in earlier stage of recombination, and this wes explained by the reduction of the disproportionated phase. The reduced strength was, however, recovered by further recombination, and this was explained by the fact that as the recombination continues the recombined grains adhere together. The optimally HDDR processed material has a comparable or even higher strength with respect to the initial sintered material prior to the solid-HDDR. The present study suggested that the rigidity of Nd-Fe-B-type material could be retained even after the solid-HDDR.

  • PDF

치은연하치석제거술시 Nd : YAG 레이저를 이용한 효과에 관한 주사전자현미경적 연구 (The Scanning Electron Microscopic study on the effect during subgingival calculus removal using Nd:YAG laser)

  • 전용선;최병선;이석초;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제27권2호
    • /
    • pp.411-424
    • /
    • 1997
  • The purpose of this study was to evaluate in vitro the effects during subgingival calculus removal using Nd:YAG laser. The study group was consisted of 30 teeth with advanced periodontal disease extracted before the start of periodontal therapy. The specimens were divided into 8 different groups : 1) untreated control 2) scaling and root planing only 3) laser treated using 150mJ/pulse, 1sec, 5sec, contact mode 4) laser treated using 200mJ/pulse, 5sec, contact mode 5) laser treated using 150mJ/pulse, 1sec, non-contact mode 6) laser treated using 200mJ/pulse, 5sec, non-contact mode 7) laser treated using l5OmJ/pulse, 1sec, contact mode with water irrigation 8) laser treated using 200mJ/pulse, 5sec, contact mode with water irrigation. All specimens were prepared for evaluation by scanning electron microscopy(SEM). Specimens from Group 2 exhibited a smear layer of scale like texture with parallel instrument tracks resulting from curet use. Specimens treated by contact mode, Group 3 and 4 featured surface changes not observed· in controls such as charring, randomly distributed pitting and crater formation, and melting down of the tooth material and calculus. Specimens treated by noncontact mode, Group 5 and 6 featured similar surface changes observed in contact mode. However, the differences between contact and non-contact groups not significant. Specimens treated by contact mode with water irrigation, Group 7 and 8 featured slight surface change compared to other groups. The results suggested that Nd: YAG laser did not completely remove the subgingival calculus but was possible the application as adjunctive method.

  • PDF

효율적인 제조 방법을 통한 비금속-펜타졸 염화합물의 합성 (Synthesis of Energetic Metal-free Cyclo-pentazolate Salts Through Efficient Preparation Method)

  • 권국태;김승희;이소정;유해욱
    • 한국추진공학회지
    • /
    • 제25권6호
    • /
    • pp.66-73
    • /
    • 2021
  • 우수한 고에너지물질의 개발은 질소 함량이 높은 화합물을 합성하는 방향으로 진행되어 왔으며, 궁극적으로 폴리질소의 형태를 지향한다. 폴리질소의 한 가지인 cyclo-N5-가 합성되고 다양한 금속, 비금속 화합물의 형성 결과가 확인됨에 따라, 폴리질소 화합물의 활용 가능성이 주목받고 있다. 그러나 다양한 펜타졸 염화합물 합성의 시작물질인 NaN5의 알려진 합성조건이 매우 극단적이고, 정제방법이 복잡한 만큼, 향후 pentazolate 화합물의 활용성을 높이기 위해서는 합성 및 정제 공정의 개선이 필수적이다. 본 연구에서는 NaN5 정제 방법을 단순한 여과 방식만을 적용하였으며, 이를 기반으로 두 가지 비금속-펜타졸 염화합물을 성공적으로 합성하였다.

액상구비의 시용시기가 오차드그라스의 건물수량에 미치는 영향 (The Effect of Application Times of Cattle Slurry on Dry Matter Yield in Orchardgrass)

  • 조익환;전하준
    • 한국유기농업학회지
    • /
    • 제6권1호
    • /
    • pp.99-108
    • /
    • 1997
  • The aim of this experiment was to investigate the effect of applying times of cattle slurry on dry matter yield of Orchardgrass, when cattle slurry applied at rates of 30m3(average mineral nitrogen fertilizer equivalent to 120kg) per ㏊ in different dressing times, such as S1(1st and 2nd growth), S2(1st and 3rd growth), S3(1st and 4th growth), S4(2nd and 3rd growth), S5(2nd and 4th growth) and S6(application for 3rd and 4th growth). The results were as follows. 1. The average annual yields of dry matter were produced 6.36~7.42 ton per ㏊ in 1995~1997 when cattle slurry applied at rates of 30m3(average mineral nitrogen fertilizer equivalent to 120kg) per ㏊ in different dressing times, especially these tendency were shown higher annual dry matter in S4 plot9application for 2nd and 3rd growth). Those were higher 2.48~3.54 tons or 1.22~2.28 tons per ㏊ than the yields from non-fertilizing or phosphrous and potassium fertilizing. 2. Relative yields of annual dry matter in cattle slurry application plots were 164(S2 plot)~191(S4 plot)% in comparing with non-fertilizing plot. 3. Dry matter yields according to cutting frequency were highest at the 2nd cut(1.50 ton) and were in the order 3rd cut(0.95 ton)>4th cut(0.75 ton)>1st cut(0.69 ton/㏊). Also, those of cattle slurry application plot per ㏊ were in the order 2nd cut(2.02~2.73 tons)>3rd cut(1.56~2.08 tons)>4th cut(1.07~1.68 tons)>1st cut(1.11~1.45 tons/㏊). 4. Relative yields of annual dry matter in cattle slurry application plots were 164~219, 161~210, 143~212 and 135~182% at the 3rd, 1st, 4th and 2nd cut, respectively in comparing with non-fertilizing plot. 5. The efficiencies of nitrogen on dry matter yield(kg DM/kg N) were 18.1, 21.3 and 34.5kg DM/kg N when cattle slurry applied to Orchardgrass at rates of 30m3 (average mineral fertilizer equivalent to 120 kg) per ㏊ in 1993, 1994 and 1995, respectively, especially these tendency were shown higher efficiencies in S4 plot(application for 2nd 3rd growth). On the other hand, those of the same level fertilization of mineral nitrogen were 43.8, 19.2 and 13.4 kg DM/kg N in 1993, 1994 and 1995, respectively.

  • PDF

반복 사용된 IPS Empress 2의 표면경도와 pressing accuracy에 관한 연구 (SURFACE HARDNESS AND PRESSING ACCURACY OF REUSED IPS EMPRESS 2)

  • 손외수;김유리;이경자;진태호
    • 대한치과보철학회지
    • /
    • 제41권5호
    • /
    • pp.596-605
    • /
    • 2003
  • Statement of problem : IPS Empress2 system was developed and used in prosthodontic treatment, but the cost of ingot is expensive for wide application. Purpose : This study was to investigate the possibility on recycling of IPS Empress 2 ceramic for wide application of IPS Empress 2 ceramic in prosthodontic treatment. Material and Method : 1st, 2nd and 3rd pressed disc-shaped($10{\times}1.5mm$) IPS Empress 2 specimens were made with IPS Empress ingot(200, Ivoclar, Liechtenstein) and pressing furnace(IPS Empress EP 500, Ivoclar, Liechtenstein). Vicker's surface hardness and fracture toughness, acid resistance, and pressing accuracy of IPS Empress 2 ceramic were measured and analyzed. Surface hardness was measured by microhardness tester(MTX 70. Matsuzawa, Japan), before and after surface treatment with 0.5% hydrofluoric acid and carbonic acid(Coca cola) for evaluation of acid resistance. Results : The surface hardness of 1st pressed specimen was the higher(5.11 GPa) than those of 2nd pressed(4.89 GPa) and 3rd pressed specimen(4.86 GPa), and the fracture toughness of 1st pressed ($1.58MPam^{1/2}$) and 2nd pressed specimen($1.51MPam^{1/2}$) were higher than that of 3rd pressed specimen($1.39MPam^{1/2}$). The changes of surface hardness of 1st, 2nd, and 3rd pressed specimens after treatment with fluoric acid were 0.17, 0.06, 0.05 (GPa) respectively, and those of 1st, 2nd, and 3rd pressed specimens after treatment with carbonic acid were 0.07, 0.00, 0.05(MPa) respectively. The pressing accuracy of 1st,2nd and 3rd specimen were 77.22%, 85.681%, and 75.05%. The pressing accuracy of 2nd pressed specimen was higher than that of the 3rd specimen. Conclusion : The changes of physical properties according to recycling of IPS Empress 2 from this study were insignificant. Therefore the possibility of recycling of IPS Empress 2 can be suggested from the results.