• 제목/요약/키워드: ND4

검색결과 5,022건 처리시간 0.036초

광섬유와 회절격자쌍을 이용한 Additive-Pulse Mode-Locking된 CW Nd:YLF 레이저의 광펄스 압축 (Pulse Compression of an Additive-Pulse Mode-Locked CW Nd:YLF Laser by Using an Optical Fiber and a Grating Pair)

  • 안승준
    • 한국광학회지
    • /
    • 제4권1호
    • /
    • pp.66-72
    • /
    • 1993
  • 파장이 $1.053{\mu}m$에서 연속 발진하는 Nd:YLF 레이저에, 비선형 매질로서 단일모드 광섬유를 이용한 외부 공진기를 연결하여 additive-pulse mode-locking(APM)된 펄스를 얻었다. APM 펄스의 펄스폭은 4.5 ps이며 평균 출력은 1.5W이다. APM 펄스를 광섬유와 회절격자쌍을 이용하여 peak power가 17 kW인 210 fs의 극초단 펄스로 압축하였다.

  • PDF

Compact, Wavelength-selectable, Energy-ratio Variable Nd:YAG Laser at Mid-ultraviolet for Chemical Warfare Agent Detection

  • Kim, Jae-Ihn;Cho, Ki Ho;Lee, Jae-Hwan;Ha, Yeon-Chul
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.243-247
    • /
    • 2019
  • We have developed a compact, wavelength-selectable, Q-switched Nd:YAG laser at mid ultraviolet for chemical warfare agent detection. The fundamental wave at 1064 nm is delivered by a pulsed solid state laser incorporating with a square-type Nd:YAG rod in a resonator closed by two crossed Porro prisms for environmental reliability. The output energy at 213 nm ($5{\omega}$) and 266 nm ($4{\omega}$) by ${\chi}^{(2)}$ process in the sequentially disposed BBO crystals are measured to be 6.8 mJ and 15.1 mJ, respectively. The output wavelength is selected for $5{\omega}$ and $4{\omega}$ by a motorized wavelength switch. The energy ratio of the $5{\omega}$ to the $4{\omega}$ is varied from 0.05 to 0.85 by controlling the phase matching temperature of the nonlinear crystal for sum-frequency generation without change of the output pulse parameters.

TFT-LCD bus line용 AlNd 박막 특성에 관한 연구 (The characteristics of AlNd thin film for TFT-LCD bus line)

  • Dong-Sik Kim;Sung Kwan Kwak;Kwan Soo Chung
    • 한국진공학회지
    • /
    • 제9권3호
    • /
    • pp.237-241
    • /
    • 2000
  • TFT-LCD(thin film transistor-liquid crystal display) 패널의 데이터 배선 재료로 사용하기 위하여 AlNd(2 wt%)의 Al합금 박막을 dc 마그네트론 스퍼터링 방법으로 유리 기판에 증착하여 열처리전과 열처리후의 구조적, 전기적, 식각 박막 특성을 조사하였다. 또한 증착한 박막을 식각하여 그 특성을 조사하였고, ITO를 증착하여 AlNd과의 접촉 저항을 Kelvin resistor를 사용하여 측정하였다. 증착된 박막을 $350^{\circ}C$에서 20분간 열처리 하였을때 AlW박막은 비저항이 감소하였고 약 $4\;{\mu\Omega}cm$의 아주 좋은 비저항 특성을 보였다. 주사전자 현미경(SEM)과 원자힘현미경(AFM)으로 표면을 분석한 결과 좋은 힐록방지 특성을 보임을 알 수 있었다. AlNd의 식각 특성은 아주 좋게 나타났고, ITO와 AlNd의 최저 접촉저항값은 약 $110\;{\mu\Omega}cm$이었다. 측정된 특성들을 바탕으로 AlNd(2 wt.%) 박막의 적용 가능성을 해상도와 화면 크기 측면에서 살펴보았을 때, 25인치 SXGA급 패널에 적용 가능함을 알 수 있었다.

  • PDF

마이크로스트립 형 다이플렉서 대역폭의 가변성에 관한 연구 (A Study on Variations of Bandwidth for a Microstrip Line Diplexer)

  • 박일
    • 대한전자공학회논문지TC
    • /
    • 제48권2호
    • /
    • pp.65-71
    • /
    • 2011
  • 본 논문에서는 5-마이크로스트립선의 4-포트 다이플렉서에서 선간 간격을 조정 한 결과로부터 2번, 4번 선로 길이를 변동 시켜서 대역폭에 대한 변화를 알아보았다. 2번 선로 길이만을 조정한 경우 대역폭이 300MHz 축소되었으며 다이플렉서 특성을 한개 포트 입력에서만 구할 수 있었으나 2, 4번 선로 길이를 동시에 조정한 경우는 입력 포트 2개에서 모두 다이플렉서 특성을 얻을 수 있었다. 통과 대역에 대한 대역폭은 4번 선로의 변동 시 변경 전과 동일한 결과를 얻었다. 특히 저지대역에서는 선로 길이 조정 전보다 중심 주파수에서 출력 포트와의 이격도가 1번 포트 입력인 경우 41dB, 2번 포트 입력에 대한 출력 포트간 이격도는 32dB을 보인다.

급속응고중 외부자장에 의한 Nd-Fe-Co(-Zr)-B계 합금의 자기이방성 향상 (The Effect of Magnetic Field on Enhancing the Anisotropy of Melt-spun Nd-Fe-Co(-Zr)-B Alloy)

  • 이우영;최승덕;양충진
    • 한국자기학회지
    • /
    • 제2권3호
    • /
    • pp.233-238
    • /
    • 1992
  • 유도용해법으로 $Nd_{14}Fe_{76}Co_4B_6$합금 및 $Nd_{10.5}Fe_{79}Co_2Zr_{1.5}B_7$합금의 급냉리본을 제조하고, 냉각속도와 급냉중 외부자장력이 결정이방성과 자기특성에 미치는 영향을 조사하였다. 토크자력계로 측정한 두 합금의 결정자기 이방성은 냉각속도가 증가함에 따라 급격히 감소하였다. 가장 우수한 자기 특성은 두 합금 모두 냉각속도 $V_s$=11 m/s에서 얻어졌으며, 자장중 급냉한 합금의 결정자기이방성 상수가 자장없이 급냉한 합금보다 30~40 % 높게 측정되었다. 외부 자장하에서 급냉된 $Nd_{10.5}Fe_{79}Co_2Zr_{1.5}B_7$합금은 냉각속도 $V_s$=11 m/s에서 $B_r$=8.82 kG, $_iH_c$=9.85 kOe 및 $(B{\cdot}H)_{max}$=16.4 MGOe의 우수한 자기특성을 보인다.

  • PDF

불화나트륨 이온도포와 Nd:YAG laser 조사가 치근면 내마모성에 미치는 영향 (Effect of NaF iontophoresis and Nd:YAG laser irradiation on the abrasion-resistance of root surface)

  • 김진덕;염창엽;김송욱;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제27권4호
    • /
    • pp.819-828
    • /
    • 1997
  • The purpose of this study was to evaluate the abrasion-resistance of root surface after NaF iontophoresis, Nd:YAG laser irradiation and combined treatment 50 anterior teeth with flat interproximal root surface that had been extracted due to periodontal destruction were selected. All teeth were treated by the same procedure as conventional periodontal root treatment, such as scaling and root planing, root conditioning with tetracycline HCI(lOOmg/ml, 5min). The pre-treatment weight of each tooth was measured by a dial scale(SHIMADEU Co, LIBROR EB-220HU, capacity 220.000 g, Japan). All teeth were divided into 5 groups as follows: Nd:YAG laser irradiation(group 1, 1 W, 100 mJ, 10Hz, fiberoptic-root surface distance=5mm, $10\;sec.{\times}6times$, EL.EN.EN060, Italy): NaF iontophoresis(group 2, $150{\mu}A$, 4 min}: Nd:YAG laser irradiation following NaF iontophoresis(group 3): NaF iontophoresis following Nd:YAG laser irradiation(group 4): No treatment(control group). Electric toothbrushing (Oral-B, Brown Co, Germany) was conducted during 1 hour($lO\;min.{\times}6\;times$). Subsequently post-treatment weight was remeasured by the same method as pre-treatment weight measurement. The difference of abrasion rate among all groups was statistically analyzed by ANOVA(SAS program). Following results were obtained: 1. The abrasion rate was significantly lower in Nd:YAG laser irradiation group than NaF iontophoresis group(p < 0.001). 2. The abrasion rate was significantly lower in combined groups of Nd:YAG laser irradiation and NaF iontophoresis than either Nd:YAG laser irradiation group or NaF iontophoresis group(p < 0.001). 3. There was no significant difference in abrasion rate according to application order in the combined groups(p > 0.05). 4. The abrasion rate was significantly lower in all experimental groups than control group(p < 0.001). The results suggest that combined treatment of Nd:YAG laser irradiation and NaF iontophoresis on exposed root surface after periodontal therapy can enhance the abrasion-resistance of root surface and may inhibit the root caries development.

  • PDF

NdFeB 박막의 자기적 특성 및 미세구조에 미치는 buffer layer의 영향 (Effect of buffer layer on the microstructure and magnetic properties of NdFeB thin films)

  • 조성호;김형태;김윤배;;이갑호
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2002년도 동계연구발표회 논문개요집
    • /
    • pp.234-235
    • /
    • 2002
  • NdFeB 박막자석은 Sputtering, MBE, Laser ablation법에 의해 제조되고 있으며[1-3] milli-size motor[4], magnetic recording media[5], micro-patterning[3]등에 응용될 수 있다. 최근에는 MEMS(Micro-electro mechanical system)분야에서도 잠재적 응용가능성을 지니고 있는 것으로 알려져 있다. 최근에는 NdFeB 박막 제조 시 자성층의 산화방지 및 자기 특성을 향상을 위하여 buffer layer를 이용한 많은 연구가 이루어지고 있다.[6] (중략)

  • PDF

개에서 불용성 근위축과 골절 치유에 대한 Nandrolone decanoate의 효과 (Effect of Nandrolone Decanoate on Disuse Muscle Atrophy and Bone Beating in Dogs)

  • 윤성진;임지혜;미자누르 라흐만;변예은;김완희;권오경
    • 한국임상수의학회지
    • /
    • 제22권4호
    • /
    • pp.336-341
    • /
    • 2005
  • 개에서 Nandrolone decanoate(ND)의 수술 후 외고정 등에 의한 불용성 근위축과 골절 치유에 미치는 영향을 평가하기 위하여 본 실험을 실시하였다 $3.3\~5.5kg,\;2\~4$세의 건강한 잡종견 20두를 대조군(A군, 4두), 1.5mg/kg ND 투여군(수술 직후 투여 - B군, 8두), 7.5mg/kg ND 투여군(수술 직후 투여 - C군, 8두)으로 나누어 무작위로 실험에 사용하였다. 요골의 골간에 골절을 유발하여 1mm 간격을 유지하며 plate로 고정하였다 ND (Deca-Durabolin 50mg/ml, 한화제약 주식회사)투여 군은 1.5mg/kg혹은 7.5mg/kg용량의 ND를 수술 직후, 일주일에 일회씩 근육 내로 8주간 투여하였다. 수술 후 4주간 로버트 존스 포대법을 실시한 후 제거하였다. 체중과 근육의 변화를 수술 직후, 수술 2, 4, 8주 후에 각각 측정하였다 ND 투여 후 4주와 8주에 조직학적 검사를 실시하였다. 근육량의 변화는 A, B 및 C 각 군에서 수술 8주 후에 수술 전 근육량의 $-2.75\pm0.16\%,\;1.68\pm0.11\%$$1.74\pm0.48\%$의 변화를 보였다. 근육량은 대조군과 비교하여 투여군에서 투여 4주 후부터 유의적으로 증가하였다 (p<0.05). 투여군에서 용량 의존적 차이는 보이지 않았다. 조직학적 평가에서 ND투여 4주 후 투여군에서 골절된 골 사이에 형성된 섬유 결합조직층이 대조군과 비교하여 더 많이 형성되었다. 5주 후 투여군에서 섬유결합 조직층이 더욱 치밀해졌다. 이상의 결과로 보아 ND투여는 수술 후 외고정 등에 의한 불용성 근위축의 예방과 골절 치유에 유용할 것으로 사료된다.