• 제목/요약/키워드: ND:YAG 레이저

검색결과 777건 처리시간 0.028초

Nd:YAG 레이저를 이용한 마그네슘 합금의 겹치기 용접 (Lap Welding of Magnesium Alloy using Nd:YAG Laser)

  • 김종도;이정한;서정
    • 한국레이저가공학회지
    • /
    • 제14권3호
    • /
    • pp.12-16
    • /
    • 2011
  • In automotive industry, because of the consideration of fuel economy, lightweight alloys have been adopted and are expected to be extensively used in the future. Magnesium alloys are among the promising materials, due to their lightweight and good mechanical properties. This study is related to the laser weldability of AZ31B magnesium alloy, an all-purpose wrought alloy with good strength and ductility. A 4kW Nd:YAG laser was used to join AZ31B sheet, and the effects of welding parameter on the quality of lap-welded joints were investigated. As a result of this study, the optimal condition was obtained, and the effect of gap distance was also revealed on the porosity control.

  • PDF

고리형 Nd:YAG 레이저에서 진동수 어긋남에 의한 출력세기의 불안정성 (Instability of the output intensity of Nd:YAG ring laser with the frequency detuning)

  • 박대윤;김기식;이재철;길상근;홍정미
    • 한국광학회지
    • /
    • 제8권3호
    • /
    • pp.204-208
    • /
    • 1997
  • 고리형 레이저에서 단일모드로 발진되는 양방향 광속의 출력세기를 맥스웰-블로흐 방정식을 사용한 준고전적 모형으로 분석하였다. Nd:YAG를 레이저 매질로 설정하고, 한쪽 방향의 광속이 반대 방향의 광속에 미치는 영향을 고려하여, 펌핑률과 감쇄율 및 진동수 어긋남에 따른 레이저 발진의 안정성과 출력변조를 조사하였다. 특히, 전산시늉을 통하여 진동수 어긋남에 따른 출력광속의 변화를 조사하고, 안정한 연속발진 조건을 규명하였다.

  • PDF

Nd:YAG 레이저 응접기의 국산화개발 및 응용 (Development of a Nd;YAG Welding System and Its Applications)

  • 김철종;이종민
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 광학 및 양자전자학 워크샵
    • /
    • pp.107-115
    • /
    • 1989
  • A 200 W industrial Nd:YAG laser was developed and its weding applications were investigated. The important factors in designing of an industrial Nd:YAG laser were analyzed and special sedign features were explained. Also, the performance of laser weldings of Zircaloy-4, stainless steel and fine thermocouples was presented.

  • PDF

비평면 고리형 공진기를 이용한 단일 모드 Nd:YAG 레이저의 내부 공진기 주파수 배가 (Intracavity frequency doubling of a single-mode Nd:YAG laser using a nonplanar ring cavity)

  • 박종락;윤태현
    • 한국광학회지
    • /
    • 제14권1호
    • /
    • pp.85-91
    • /
    • 2003
  • 비평면 고리형 공진기에서의 내부 공진기 주파수 배가를 이용한 단일 모드 Nd:YAG 레이저를 제작하였다. 비평면 고리형 공진기는 두 개의 구면경과 Nd:YAG 결정, KIP 결정으로 구성되어 있다. Nd:YAG 결정의 양단면은 상대적인 비틀림 각을 갖고 있으면서 브루스터 각이 되도록 연마되었으며, 비틀림 각에 의해 형성된 비평면 고리 공진기가 가역적인 편광 회전기 역할을, 자기장이 가해진 Nd:YAC 결정 자체가 비가역적 편광 회전기 역할을, 브루스터 각을 갖고 있는 양단면이 편광자 역할을 각각 담당하여 전체적으로 광 다이오드를 형성하고 있다. 이러한 구조에서 단 방향 발진이 일어날 수 있는 비틀림 각이 이론적으로 추정되었다. 1.2 W, 809 nm 다이오드 레이저로 펌핑하여 532 nm 파장에서 22 ㎽의 단 방향, 단일 모드 출력을 얻었으며, 이것은 약 1.8%의 변환 효율에 해당한다.

고출력 연속파형 Nd:YAG 레이저를 이용한 CSP 1N 냉연강판 절단시 절단공정변수의 절단폭에 미치는 영향 (Influence of process parameters on the kerfwidth for the case of laser cutting of CSP 1N sheet using high power CW Nd:YAG laser)

  • 안동규;김민수;이상훈;박형준;유영태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.910-915
    • /
    • 2004
  • The objective of this study is to investigate the influence of process parameters, such as power of laser, travel speed of laser and material thickness, on the practical cutting region and the kerfwidth for the case of cutting of CSP 1N sheet using high power Nd:YAG laser with continuous wave(CW). In order to find the practical cutting region and the relationship between process parameters on the kerfwidth, several laser cutting experiments are carried out. The effective heat input is introduced to consider the influence of power and travel speed of laser on the kerfwidth together. From the results of experiments, the allowable cutting region and the relationship between the effective heat input and kerfwidth for the case of cutting of CSP 1N sheet using high power CW Nd:YAG laser have been obtained to improve the dimensional accuracy of the cut area.

  • PDF

연속파형 Nd:YAG 레이저를 이용한 SM45C 맞대기 용접의 공정 변수 (Process Parameters of Butt Welding of SM45C using a Continuous Wave Nd:YAG Laser Beam)

  • 유영태;노경보;오용석;김종신;임기건
    • 한국정밀공학회지
    • /
    • 제20권7호
    • /
    • pp.44-55
    • /
    • 2003
  • The Nd:YAG laser process is known to have high speed and deep penetration capability to become one of the most advanced welding technologies. This paper describes the machining characteristics of SM45C carbon steel welding by use of an Nd:YAG laser. In spite of its good mechanical characteristics, SM45C carbon steel has a high carbon contents and suffers a limitation in the industrial application due to the poor welding properties. The major process parameters studied in the present laser welding experiment were position of focus, travel speed and laser power. Optical microscope and SEM were used to investigate the microstructures of the welded zone. The experimental results showed that penetration depth of the welding process increases with laser power. Both the microstructural investigation and the theoretical calculations indicated that materials undergoes a very high heating and cooling cycle during welding process. It was also found that the austenite nucleation takes place at the initial stage and the completion temperature of austenite transformation is much higher than in the case of the arc welding.

ND-YAG 레이저가 조사된 상아질 표면에 칫솔에 의한 기계적 마모가 미치는 영향에 대한 실험적 연구 (The experimental study for the effect of tooth-brushing on the laser irradiated dentin surface)

  • 박동성
    • Restorative Dentistry and Endodontics
    • /
    • 제27권6호
    • /
    • pp.555-560
    • /
    • 2002
  • 치근부 민감성 (hypersensitivity)은 부분적으로 치근면에서의 개방된 상아세관이 존재하는 것에 기인한다고 생각되며 이러한 치근부의 개방된 상아세관은 치경부 병소 (cervical lesion)에 주로 존재하는데 이는 칫솔질에 의한 마모(toothbrush abrasion), 화학적 침식 (chemical erosion), 또는 abfraction 등의 결과로 나타난다고 한다. 이미 Nd-YAG 레이저를 이용한 실험에서 레이저를 조사한 상아질 표면의 상아 세관 구경이 감소되고 상아세관의 폐쇄가 많이 증가되는 양상을 관찰한 바 있다. 이 실험의 목적은 고출력레이저인 Nd-YAC 레이저를 이용한 상아질 표면처치의 임상사용가능성을 좀 더 상세히 평가하기 위해 상아질에 레이저를 처리한 후 기계적으로 마모시킨 경우 상아질 표면의 변화를 관찰하는 것이다. 50개의 발치된 치아의 상아질을 노출시켜 표면을 연마한 후 대조군에서는 37% 인산으로 산부식하여 상아 세관을 노출시킨 후 레이저를 조사하였고, 실험군에서는 대조군과 같은 조건으로 산과 레이저로 처리된 상아질 표면을 15, 45, 90 그리고 180분 동안 전동 칫솔로 기계적으로 마모시켜 그 표면을 주사전자현미경으로 관찰한 결과, 대조군, 칫솔질을 15, 45분간 시행한 실험군에서는 상아 세관 입구가 10% 이내에서 노출되었고 50 그리고 180분간 칫솔질을 시행한 실험군에서는 45 그리고 48%의 상아세관 입구의 노출이 관찰되었다. 그러므로 Nd-YAC레이저의 조사는 상아질 표면에서 축적 시간이 45분 이상에서 90분 이하인 기계적 마모에 의한 상아 세관 입구의 노출을 억제할 수 있을 것이라 사료된다.