• Title/Summary/Keyword: N-R Method

Search Result 1,650, Processing Time 0.037 seconds

Inhibition of Melanin Synthesis by Enhanced Cytosolic Delivery of N-glycosylation Inhibitors Using pH-Sensitive Nano-carrier (pH 감응형 나노입자를 이용한 멜라닌 합성저해 연구)

  • Park, Ju-Young;Park, Hyun-Jung;Shim, Jong-Won;Ahn, Soo-Mi;Kim, Junoh;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.1
    • /
    • pp.29-32
    • /
    • 2004
  • Inhibition of the early N-glycosylation process in the endoplasmic reticulum prevents the activation of tyrosinase, a key enzyme for melanin biosynthesis. This work aims at evaluating the increased activity of N-glycosylation inhibitors in vitro b, employing a nano-sized pH-sensitive liposome as a delivery carrier. Melexsome, a pH-sensitive nano carrier loaded with glycosylation inhibitos, was prepared by the hydration method with phospholipids and cholresterol-based amphiphiles. Inhibitory effects of Melexsome on the N-glycosylation process were evaluated by EndoH & PNGaseF digestion and the western blotting. Melanin synthesis was also monitored after treatment with Melexsome Interestingly, Melexsome effectively increased the efficacy of N-glycosylation inhibitors. Melexsome was also much more efficiently translocated into the cytoplasm as observed in CLSM. These results demonstrated that the amphiphilic lipid-based pH-sensitive nano-carriers could be, used as an efficient delivery system for N-glycosylation inhibitor to enhance the effects of skin whitening cosmetics.

A study on the effect of residual stress on fatigue crack propagation rate of SS 41 material (SS 41材의 疲勞크랙 傳播速度에 미치는 熔接殘留應力의 影響에 관한 硏究)

  • Chung, Suk-Choo;Han, Byeong-Kee;Chung, Kang
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.473-480
    • /
    • 1988
  • In this study, a method that can realize the effect of residual stresses on fatigue crack propagation has been proposed. This method requires that the relaxation quantities of residual stresses are measured by experimental method according to fatigue cycles and are employed to the experimental results of base materials by introducing the concept of superposition. SS41 material has been analyzed as an example. The results show that the relaxation factor of residual stresses for fatigue cycles is .alpha.$_{i}$= 1/0.6903+0.0380 $a_{I}$ the effective stress ratio for fatigue crack propagation length is ( $R_{eff}$)$_{i}$ = 1/1.1274+0.0118$_{I}$ and the fatigue crack propagation rate for relaxation quantities of residual stresses is (da/dN)$_{t}$ = 0.5 $K_{cf}$ - .DELTA.K/{1-1/1.1274+0.0118$_{ai}$ } $K_{cf}$ - .DELTA. K(da/dN), for stress ratio /R=0.5.io /R=0.5.5.

Fabrecation and Characterization of $SrBi_2TaNbO_9$ Ferroelectric Thin Film Prepared by Sol-Gel Method (SOL-GEL법을 이용한 $SrBi_2TaNbO_9$ 강유전성 박막 제조 및 특성 평가)

  • 이진한;박상준;장건익
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.94-98
    • /
    • 2000
  • Polycrystalline SBTN ferroelectric thin films were prepared by sol-gel method with various Nb mole ratios on Pt/ $SiO_2$/Si (100) substrates. The films were annealed at different temperatures and characterized in terms of phase and microstructure. Relatively a well saturated hysteresis pattern was obtained at x =0.2 in S $r_{0.8}$B $i_{2.3}$(T $a_{1-x}$ N $b_{x}$)$_2$ $O_{9+}$$\alpha$/ thin films. At an applied voltage of 5V, the dielectric constant ($\varepsilon$$_{r}$) and dissipation factor (tan $\delta$) of typical S $r_{0.8}$B $i_{2.3}$(T $a_{1-x}$ N $b_{x}$)$_2$ $O_{9+}$$\alpha$/ thin film (x=0.2) were about 236.2 and 0.034. Measured remanent polarization (2Pr) and coercive field (Ec) were 4.28C/c $m_2$, and 38.88kv/cm respectively. No fatigue was observed up to 6$\times$10$_{10}$ switching cycles at 5V and the normalized polarization reduced by a factor of only 4%.%. 4%.%. 4%.%.%.%.%.

  • PDF

Designing Coherent User Interfaces of N-Screen Services Reflecting Users' Task Knowledge

  • Park, Hwan-Su;Lee, Dong-Seok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.1
    • /
    • pp.41-48
    • /
    • 2012
  • Objective: Companies want to expand their business by providing their services at other devices and new services based upon existing services. Therefore, they look for building brand identity by providing same experience throughout devices and services. Background: Many services are available to use at multiple devices including mobile phones, tablet, personal computers, and televisions, thanks to proliferation of n-screen and cloud technology. Method: It was discussed that consistency, which emphasizes the regularity and has been one of essential aspects of user interface design, seems not effective to be applied to n-screen services, owing to different screen size, input and output peripherals, usage environment and users' attitude. Results: A new definition of same experience among different devices and services, called coherence, was introduced and abstraction levels of user interfaces were proposed as the denominator of defining coherence. Then types of users' task knowledge at each abstraction level were discussed with examples. Conclusion: This paper concluded by discussing design requirements for designing coherent user interfaces among devices and services.

Non-invasive Fdlow-up of Pulmonary artey by EBT Other Palliatrve Shunt Operatin (청색증형 선천성 심질환아의 고식적 수술 이후 EBT에 의한 폐혈관계이 비침습적 추적 검사)

  • 김민정;박영환;홍유선;이종균;최규옥;조범구
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.7-19
    • /
    • 2000
  • Background :To assess the accuracy of Electron-Beam Tomography(EBT) in following evaluation of the pulmonary vascular system after a shunt operation in the cyanotic con-genital heart disease with pulmonary stenosis or pulmonary atresia. Material and Method : Sixteen patients(M:F=11:5) who received Blalock-Taussig(n=8) bidirectional cavo-pulmonary shunt(n=10) and unifocalization (n=2) were ncluded in the study. We evaluated the patency of the shunt the morphology of intrapericardial and hilar pulmonary arteries(PA) peripheral pulmonary vascularity by background lung attenuation and the abundance of arterial & venous collateral. Angiography(n=12) and echocardiography(n=20) were used as the gold standard for the comparison of EBT results. Result: EBT was consistent with angiogram/ echo in 100% of the evaluation for the patency of the shunt and in 12(by angiogram 100%) and 19(by echo 95%) for the detection the hypoplasia stenosis or interruption of central PA In measuring of PA EBT and angiogram corrlated(r=0.91) better than EBT-echo(r=0.88) or echo-angiogram(r=0.72) Abundant systemic arterial collateral were noted in 4 and venous collateral in 3 cases. In evaluating the peripheral pulmonary vascularity the homogenous and normal-ranged lung attenuation(m=6) decreased but homo-genous attenuation(n=1) segment-by-sgment heterogeneous attenuation(n=3) homogenous but asymmetrical attenuation(n=3) segment-by-segment heterogeneous attenuation(n=3) homogenous but asymmetrical attenuation(n=3) and venous congestion(n=2) were observed nd 12 of them were compatible with the blood flow pattern revealed by cardiac catheterization. Conclusion: EBT was accurate in the integrated evaluation of the pulmonary vascular system after the shunt including the patency of the shunt operaion the morphology and dimension of the central and hilar PAs and the loco-regional pulmonary flow in the lung parenchyma. It suggests the useful information about the need of secondary shunt operation the proper timing time for total repair and the need of interventional procedure prior to total repair.

  • PDF

Internal Fixation of Medpor® Implant for Prevention of Enophthalmos in Posteriorly Extended Orbital Floor Fracture (후방까지 연장된 안와하벽골절에서 안구함몰 예방을 위한 Medpor® 내고정술)

  • Suhk, Jeong Hoon;Ji, So Young;Kim, Tae Bum;Yang, Wan Suk
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.2
    • /
    • pp.55-61
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate the effectiveness of internal fixation method of $Medpor^{(R)}$ implant with $BioSorb^{TM}FX$ screw which is used for prevention of enophthalmos in posteriorly extended large orbital floor fracture. Methods: From Jun. 1997 to Dec. 2007, 21 patients who were diagnosed with posteriorly extended large orbital floor fractures were classified into two groups. One group(n=11) had undergone reduction surgery with regular $Medpor^{(R)}$ sheets without any fixation method, while the other group(n=10) had their $Medpor^{(R)}$ sheets fixed with the $BioSorb^{TM}FX$ screws. The two groups were evaluated by comparison of their enophthalmos degree and effectiveness. Results: In the non-fixation group, six patients had enophthalmos preoperatively and three of them showed persistent enophthalmos postoperatively. In postoperative CT examination, displacement of $Medpor^{(R)}$ implant with soft tissue impaction into maxillary sinus was observed in the patients. In the screw fixation group, three patients had enophthalmos preoperatively, but none of them suffer from complication such as residual enophthalmos, soft tissue impaction, muscle entrapment or optic nerve compression postoperatively. Conclusion: Internal fixation method of $Medpor^{(R)}$ implant with $BioSorb^{TM}FX$ screw on the medial surface of orbital floor provides firm stabilization of implants and surrounding soft tissues and can be an effective option especially when postoperative implant displacement or malposition was expected.

ON THE PRESCRIBED MEAN CURVATURE PROBLEM ON THE STANDARD n-DIMENSIONAL BALL

  • Bensouf, Aymen
    • Journal of the Korean Mathematical Society
    • /
    • v.53 no.2
    • /
    • pp.287-304
    • /
    • 2016
  • In this paper, we consider the problem of existence of conformal metrics with prescribed mean curvature on the unit ball of ${\mathbb{R}}^n$, $n{\geq}3$. Under the assumption that the order of flatness at critical points of prescribed mean curvature function H(x) is ${\beta}{\in}[1,n-2]$, we give precise estimates on the losses of the compactness and we prove new existence result through an Euler-Hopf type formula.

Comparison of Antibacterial Ointments for Antibacterial and Wound Healing Effect on Infected Full Thickness Skin Defect in the Mouse (흰 쥐의 감염된 전층피부결손에 대한 항균연고들의 항균효과 및 창상치유 효과의 비교)

  • Jeon, So-Yeon;Lee, Jong-Hoon;Min, Kyung-Hee;Hong, Sung-Hee;Lee, Won-Mi;Chae, Jeong-Don;Jun, Jin-Hyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.2
    • /
    • pp.115-121
    • /
    • 2010
  • Purpose: Many topical agents had been used for contaminated wound treatment. Although antimicrobial ointments were widely used as topical agents, their comparative antibacterial and wound healing effects were largely unreported. The purpose of this study was to compare antibacterial effects and wound healing effects of common topical ointments on infected full thickness skin defect in the mouse. Methods: One full thickness skin defects in the mice (n=60) were developed on the back and left open for twenty-four hours. Sixty mice were divided into four groups: group B (dressing with Bactroban$^{(R)}$, n=15), group I (dressing with Iodosorb$^{(R)}$, n=15), group T (dressing with Terramycin$^{(R)}$, n=15), group G (control group, dressing with dry gauze, n=15). The size of wound defects and the grades of wound healing were evaluated at 4, 7, 10 days, and antibacterial effect was evaluated with restricted zone in Mueller Hinton agar by disk diffusion method. After the wound was left open for twenty-four hours, many Staphylococcus aureus was cultured. The wound defect size was decreased in order of Bactroban$^{(R)}$ (B), Iodosorb$^{(R)}$ (I), Terramycin$^{(R)}$ and gauze dressing group in all days, but difference among experimental groups was not statistically significant. The grade score of wound healing was increased in order of Bactroban$^{(R)}$, Iodosorb$^{(R)}$, Terramycin$^{(R)}$ and gauze dressing group, and the difference was statistically significant. Antibacterial effect for was increased in order of Bactroban$^{(R)}$, Iodosorb$^{(R)}$, Terramycin$^{(R)}$ and gauze dressing group, and the difference was statistically significant. Conclusion: Topical antimicrobial ointments application was effective against wound infections by S. aureus. Bactroban$^{(R)}$ may be an optimal topical treatment for infected wounds according to this study. However, further study is necessary to evaluate the clinical efficacy of antimicrobial ointments and to search for the mechanisms that explain their effects.

Study on the Midwater Trawl Available in the Korean Waters - IV (한국 근해에 있어서의 중층트로올의 연구 - IV)

  • 이병기
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.1
    • /
    • pp.6-10
    • /
    • 1987
  • The authors carried out an experiment to measure the hydrodynamic resistance of the gear and the efficiency of otter board of the midwater trawl, which is the same used in the former experiment in this series of studies. The whole resistance of the gear was measured by a 10 ton scale recording tension meter, and they were analyzed into the shearing force and the drag with relevant factors determined in the former experiments. The results obtained can be summarized as follows: 1. The whole drag of gear T(kg) and the drag of net R sub(N) (kg) can be expressed as T=2.15 v super(1.12). R sub(N)=1.96 v super(1.01) (v: towing speed in m/sec) 2. The formula of estimating the drag of net deduced by Koyama's method can be expressed as R sub(N)=4.3$\times$d/l$\times$abv 3. The shearing force and the drag of otter board is about 19 to 22% and 5 to 7% of the drag of net, respectively. Whereas, the shearing coefficient and the drag coefficient calculated by the resistance and the opening of gear are 1.5 and 0.42, respectively.

  • PDF

Low resistivity Ohmic Co/Si/Co contacts to n-type 4H-SiC (낮은 접촉 저항을 갖는 Co/Si/co n형 4H-SiC의 오옴성 접합)

  • Kim, C.K.;Yang, S.J.;Lee, J.H.;Cho, N.I.;Jung, K.H.;Kim, N.K.;Kim, E.D.;Kim, D.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.764-768
    • /
    • 2002
  • Characteristics of ohmic Co/Si/Co contacts to n-type 4H-SiC are investigated systematically. The ohmic contacts were formed by annealing Co/Si/Co sputtered sequentially. The annealings were performed at $800^{\circ}C$ using RTP in vacuum ambient and $Ar:H_2$(9:1) ambient, respectively. The specific contact resistivity$(\rho_c)$, sheet resistance$(R_s)$, contact resistance$(R_c)$, transfer length$(L_T)$ were calculated from resistance$(R_T)$ versus contact spacing(d) measurements obtained from TLM(transmission line method) structure. While the resulting measurement values of sample annealed at vacuum ambient were $\rho_c=1.0{\tiimes}10^{-5}{\Omega}cm^2$, $R_c=20{\Omega}$ and $L_T$ = 6.0 those of sample annealed at $Ar:H_2$(9:1) ambient were $\rho_c=4.0{\tiimes}10^{-6}{\Omega}cm^2$, $R_c=4.0{\Omega}$ and $L_T$ = 2.0. The physical properties of contacts were examined using XRD and AES. The results showed that cobalt silicide was formed on SiC and Co was migrated into SiC.

  • PDF