• Title/Summary/Keyword: N-R Method

Search Result 1,657, Processing Time 0.041 seconds

The measurement of dicamba in soil and plants (토양 및 식물 중 디캄바 측정법에 대한 연구)

  • Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.480-487
    • /
    • 2009
  • The herbicide dicamba (2-methoxy-3,6-dichlorobenzoic acid) in soil and plants was determined by gas chromatography-mass spectrometry (GC/MS). The samples were extracted with diethyl ether at pH 2, and washed with 0.1 N HCl, and then dried. The dried residue was derivatized in 1 mL of 10% $H_2SO_4$-MeOH for 2 hr at $80^{\circ}C$. The reaction mixture was neutralized with 4 mL of sodium bicarbonate solution and reextracted with 5 mL of diethyl ether. After the extract was concentrated, dicamba was determined by GC/MS-SIM mode. There was good linearity above 0.999 in the ranges of the $1.0{\sim}100{\mu}g/kg$. Total 42 sample including 32 soil samples and 10 plants samples were analyzed by developed method. Dicamba was detected in the concentration range of $2.9-123.9{\mu}g/kg$ in 15 samples among 32 soil samples and in the concentration range of $43-33,252{\mu}g/kg$ in 5 samples among 10 plants samples. A cause of the wither and die of the pine trees is suspected to spray dicamba around or directly to them.

Establishment of an Analytical Method for Novobiocin in Livestock Products Using HPLC-UVD (HPLC-UVD를 이용한 축산식품 중 Novobiocin의 시험법 확립)

  • Park, Hee-Ra;Kwon, Chan-Hyeok;Lee, Jong-Goo;Kim, Hyung-Soo;Chae, Young-Sik;Oh, Jae-Ho;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.263-268
    • /
    • 2012
  • Novobiocin is a coumarin-containing antibiotic, and has a longer half-life in various animals than other veterinary medicines. A simple and rapid high-performance liquid chromatography assay for the determination of residual novobiocin levels in chicken, beef and milk has been developed and validated. The separation condition for HPLC/UVD was optimized by a MG II $C_{18}$ (4.6 mm $ID{\times}250$ mm, 5 ${\mu}m$) column with 0.1% formic acid in $H_2O$/0.1% formic acid in Acetonitrile (40/60, v/v) as the mobile phase at a flow rate of 1.0 mL/min and the detection wavelength was set at 340 nm. Residues were extracted from tissue by blending with methanol. After liquid-liquid partitioning, lipid materials were removed with n-hexane and purification as Silica (1 g, 6 mL) cartridge with 10 mL acetone/dichloromethane (10/90, v/v). Limit of quantification and linearity performed by the analytical method were 0.02 mg/kg and 0.999 ($r^2$), and the recovery range was $88.8{\pm}5.6-100.3{\pm}4.4$, $88.8{\pm}7.2-97.0{\pm}3.2$ and $88.1{\pm}4.3-92.8{\pm}3.6%$. It is expected that this analytical method with regards to novobiocin in chicken, beef and milk could be applied as an official method to administer food safety on veterinary medicines.

Development and Validation of an Analytical Method for Fungicide Sedaxane Determination in Agricultural Products using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 Sedaxane의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Park, Shin-Min;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Choi, Young-Nae;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.30-39
    • /
    • 2019
  • An analytical method was developed for the determination of sedaxane in agricultural products using liquid chromatograph-tandem mass spectrometry (LC-MS/MS). The samples were extracted with acetonitrile and partitioned with dichloromethane to remove the interference, and then purified by using silica SPE cartridges to clean up. The analytes were quantified and confirmed by using LC-MS/MS in positive ion mode using multiple reaction monitoring (MRM). The matrix-matched calibration curves were linear over the calibration ranges ($0.001-0.25{\mu}g/mL$) into a blank extract with $r^2$>0.99. For validation, recovery tests were carried out at three different concentration levels (LOQ, 10LOQ, and 50LOQ, n=5) with five replicates performed at each level. The recoveries were ranged between 74.5 to 100.8% with relative standard deviations (RSDs) of less than 12.1% for all analytes. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL 40, 2003) and Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for sedaxane determination in agricultural commodities.

Upper Boundary Line Analysis of Rice Yield Response to Meteorological Condition for Yield Prediction I. Boundary Line Analysis and Construction of Yield Prediction Model (최대경계선을 이용한 벼 수량의 기상반응분석과 수량 예측 I. 최대경계선 분석과 수량예측모형 구축)

  • 김창국;이변우;한원식
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.3
    • /
    • pp.241-247
    • /
    • 2001
  • Boundary line method was adopted to analyze the relationships between rice yield and meteorological conditions during rice growing period. Boundary lines of yield responses to mean temperature($T_a$) and sunshine hour( $S_{h}$) and diurnal temperature range($T_r$) were well-fitted to hyperbolic functions of f($T_a$) =$$\beta$_{0t}$(1-EXP(-$$\beta$_{1t}$ $\times$ ($T_a$) ) and f( $S_{h}$)=$$\beta$_{0t}$((1-EXP($$\beta$_{1t}$$\times$ $S_{h}$)), to quadratic function of f($T_r$) =$\beta$$_{0r}$(1-($T_r$ 1r)$^2$), respectively. to take into account to, the sterility caused by low temperature during reproductive stage, cooling degree days [$T_c$ =$\Sigma$(20-$T_a$] for 30 days before heading were calculated. Boundary lines of yield responses to $T_c$ were fitted well to exponential function of f($T_c$) )=$\beta$$_{0c}$exp(-$$\beta$_{1c}$$\times$$T_c$ ). Excluding the constants of $\beta$$_{0s}$ from the boundary line functions, formed are the relative function values in the range of 0 to 1. And these were used as yield indices of the meteorological elements which indicate the degree of influence on rice yield. Assuming that the meteorological elements act multiplicatively and independently from each other, meteorological yield index (MIY) was calculated by the geometric mean of indices for each meteorological elements. MIY in each growth period showed good linear relationship with rice yield. The MIY's during 31 to 45 days after transplanting(DAT) in vegetative stage, during 30 to 16 days before heading (DBH) in reproductive stage and during 20 days after heading (DAH) in ripening stage showed greater explainablity for yield variation in each growth stage. MIY for the whole growth period was calculated by the following three methods of geometric mean of the indices for vegetative stage (MIVG), reproductive stage (HIRG) and ripening stage (HIRS). MI $Y_{I}$ was calculated by the geometric mean of meteorological indices showing the highest determination coefficient n each growth stage of rice. That is, (equation omitted) was calculated by the geometric mean of all the MIY's for all the growth periods devided into 15 to 20 days intervals from transplanting to 40 DAH. MI $Y_{III}$ was calculated by the geometric mean of MIY's for 45 days of vegetative stage (MIV $G_{0-45}$ ), 30 days of reproductive stage (MIR $G_{30-0}$) and 40 days of ripening stage (MIR $S_{0-40}$). MI $Y_{I}$, MI $Y_{II}$ and MI $Y_{III}$ showed good linear relationships with grain yield, the coefficients of determination being 0.651, 0.670 and 0.613, respectively.and 0.613, respectively.

  • PDF

Enhancement of Inter-Image Statistical Correlation for Accurate Multi-Sensor Image Registration (정밀한 다중센서 영상정합을 위한 통계적 상관성의 증대기법)

  • Kim, Kyoung-Soo;Lee, Jin-Hak;Ra, Jong-Beom
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.4 s.304
    • /
    • pp.1-12
    • /
    • 2005
  • Image registration is a process to establish the spatial correspondence between images of the same scene, which are acquired at different view points, at different times, or by different sensors. This paper presents a new algorithm for robust registration of the images acquired by multiple sensors having different modalities; the EO (electro-optic) and IR(infrared) ones in the paper. The two feature-based and intensity-based approaches are usually possible for image registration. In the former selection of accurate common features is crucial for high performance, but features in the EO image are often not the same as those in the R image. Hence, this approach is inadequate to register the E0/IR images. In the latter normalized mutual Information (nHr) has been widely used as a similarity measure due to its high accuracy and robustness, and NMI-based image registration methods assume that statistical correlation between two images should be global. Unfortunately, since we find out that EO and IR images don't often satisfy this assumption, registration accuracy is not high enough to apply to some applications. In this paper, we propose a two-stage NMI-based registration method based on the analysis of statistical correlation between E0/1R images. In the first stage, for robust registration, we propose two preprocessing schemes: extraction of statistically correlated regions (ESCR) and enhancement of statistical correlation by filtering (ESCF). For each image, ESCR automatically extracts the regions that are highly correlated to the corresponding regions in the other image. And ESCF adaptively filters out each image to enhance statistical correlation between them. In the second stage, two output images are registered by using NMI-based algorithm. The proposed method provides prospective results for various E0/1R sensor image pairs in terms of accuracy, robustness, and speed.

Simultaneous Determination of UV Absorbers Migrated from Polyethylene and Polypropylene Food Packaging Materials into Food Simulants by HPLC-UVD (HPLC-UVD를 이용한 폴리에틸렌, 폴리프로필렌 기구 및 용기·포장 유래 자외선흡수제 동시분석법)

  • Choi, Heeju;Choi, Jae Chun;Bae, In-Ae;Lee, Chanyong;Park, Se-Jong;Kim, MeeKyung
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.434-442
    • /
    • 2017
  • The UV light in sunlight breaks down the chemical bonds in a polyolefin polymer through a process called photodegradation, ultimately causing cracking, chalking, colour changes, and loss of physical properties such as impact strength, tensile strength, elongation, and others. UV absorbers are used to prevent or terminate the oxidation of plastics by UV light. They are receptive to UV radiation and dissipate the energy harmlessly as heat. Benzotriazoles and benzophenones are used mainly in polyolefins such as polyethylene and polypropylene. In this study, we have developed a method for the analysis of 12 UV absorbers, which are Uvinul 3000, Cyasorb UV 24, Uvinul 3040, Tinuvin 312 and P, Seesorb 202, Chimassorb 81, Tinuvin 329, 234, 326, 328 and 327, migrated from the food packaging materials into four food simulants for aqueous, acidic, alcoholic and fatty foods. The UV absorbers in food simulants were determined by reversed-phase high performance liquid chromatograph-ultraviolet detector with 310 nm after solid-phase extraction with a hydrophilic-lipophilic balance (HLB) cartridge or dilution with isopropanol. The analytical method showed a good linearity of coefficient ($R^2{\geq}0.99$), limits of detection (0.049~0.370 mg/L), and limits of quantification (0.149~1.120 mg/L). The recoveries of UV absorbers spiked to four food simulants ranged from 70.05% to 110.13%. The developed method would be used as a reliable tool to determine concentrations of the migrated UV absorbers.

Development and Validation of an Analytical Method for Fungicide Fluoxastrobin Determination in Agricultural Products (농산물 중 살균제 Fluoxastrobin의 시험법 개발 및 유효성 검증)

  • So Eun, Lee;Su Jung, Lee;Sun Young, Gu;Chae Young, Park;Hye-Sun, Shin;Sung Eun, Kang;Jung Mi, Lee;Yun Mi, Chung;Gui Hyun, Jang;Guiim, Moon
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.6
    • /
    • pp.373-384
    • /
    • 2022
  • Fluoxastrobin a fungicide developed from Strobilurus species mushroom extracts, can be used as an effective pesticide to control fungal diseases. In this study, we optimized the extraction and purification of fluoxastrobin according to its physical and chemical properties using the QuEChERS method and developed an LC-MS/MS-based analysis method. For extraction, we used acetonitrile as the extraction solvent, along with MgSO4 and PSA. The limit of quantitation of fluoxastrobin was 0.01 mg/kg. We used 0.01, 0.1, and 0.5 mg/kg of five representative agricultural products and treated them with fluoxastrobin. The coefficients of determination (R2) of fluoxastrobin and fluoxastrobin Z isomer were > 0.998. The average recovery rates of fluoxastrobin (n=5) and fluoxastrobin Z isomer were 75.5-100.3% and 75.0-103.9%, respectively. The relative standard deviations (RSDs) were < 5.5% and < 4.3% for fluoxastrobin and fluoxastrobin Z isomer, respectively. We also performed an interlaboratory validation at Gwangju Regional Food and Drug Administration and compared the recovery rates and RSDs obtained for fluoxastrobin and fluoxastrobin Z isomer at the external lab with our results to validate our analysis method. In the external lab, the average recovery rates and RSDs of fluoxastrobin and fluoxastrobin Z isomer at each concentration were 79.5-100.5% and 78.8-104.7% and < 18.1% and < 10.2%, respectively. In all treatment groups, the concentrations were less than those described by the 'Codex Alimentarius Commission' and the 'Standard procedure for preparing test methods for food, etc.'. Therefore, fluoxastrobin is safe for use as a pesticide.

Reference Values of Functional Parameters in Gated Myocardial Perfusion SPECT : Comparison with $QGS^{\circledR}$ and $4DM^{\circledR}$ Program (게이트 심근 관류 스펙트의 심기능 지표의 정상 참고값 : $QGS^{\circledR}$ 프로그램과 $4DM^{\circledR}$ 프로그램의 비교)

  • Jeong, Young-Jin;Park, Tae-Ho;Cha, Kwang-Soo;Kim, Moo-Hyun;Kim, Young-Dae;Kang, Do-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.430-437
    • /
    • 2005
  • Purpose: The objectives of this study were - First, to determine the normal range of left ventricular end diastolic volume (EDV), end systolic volume (ESV) and election fraction (EF) from gated myocardial perfusion SPECT for Quantitative Gated SPECT (QGS) and 4D-MSPECT (4DM), respectively. Second, to evaluate the relationships between values produced by both software packages. Materials & Methods: Tc-99m MIBI gated myocardial perfusion SPECT were performed for 77 patients (mean age: $49.6{\pm}13.7y$, n=37(M), 40(F)) with a low likelihood (<10%) of coronary artery disease (CAD) using dual head gamma camera (E.CAM, Siemens, USA). Left ventricular EDV, ESV and EF were automatically measured by means of QGS and 4DM, respectively. Results: in QGS, the mean EDV, ESV and EF for all patients were $78.2{\pm}25.2ml,\;27.4{\pm}12.9ml\;and\;66.6{\pm}8.0%$ at stress test respectively, not different from rest test (p>0.05). In 4DM, the mean EDV, ESV and EF for all patients were $89.1{\pm}26.4ml,\;29.1{\pm}12.8ml\;and\;68.5{\pm}6.7%$ at stress test. Most cases in 4DM, there was no significant difference statistically between stress and rest test (p>0.05). But statistically significant difference was found in EF ($68.5{\pm}6.7%$ at stress vs $70.9{\pm}8.0%$ at rest, p<0.05). Correlation coefficients between the methods for EDV, ESV and EF were comparatively high (0.95, 0.93, 0.71 at stress test and 0.95, 0.90, 0.69 at rest test, respectively). However, Bland-Altman plots showed a large range of the limit value of agreement for EDV, ESV and EF between both methods ($-30ml{\sim}10ml,\;-12ml{\sim}8ml,\;-14%{\sim}11%$ at stress test and $-32ml{\sim}5ml,\;-13ml{\sim}13ml,\;-18%{\sim}12%$ at rest test). Conclusion: We found the normal ranges of EDV, ESV and EF for patients with a low likelihood of CAD in both methods. We expect these values will be a good reference to interpret gated myocardial perfusion SPECT. Although good correlation was observed between both methods, they should not be used interchangeably. Therefore, when both programs are used at the same site, it will be important to apply normal limits specific to each method.

Cellular Analysis and Measurement of Mucin in Sputum of Chronic Airway Disease (만성기도질환의 객담세포분석과 mucin의 측정)

  • Kim, Ki-Up;Kim, Yang-Ki;Shin, Chan-Young;Kim, Do-Jin;Uh, Soo-Taek;Kim, Yong-Hoon;Ko, Kwang-Ho;Park, Choon-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.1
    • /
    • pp.82-92
    • /
    • 2000
  • Background : In chronic airway disease, mucus secretion is increased, but extraction of mucin, which is the main component of mucus secretion, is a very complicated and limited in clinical use. Recently, monoclonal antibody for mucin was developed for possible clinical use. In this study, cellular analysis and quantification of respiratory mucin in sputum of patients with chronic airway diseases were performed. Method : Sputum was collected from patients with asthma(n=33), bronchiectasis(n=8) or chronic bronchitis (n=13) by spontaneous expectoration or by hypertonic saline induction. Collected sputums was treated by 0.1% dithiotreitol to dissociate the disulfide bond of the mucus and filtered through a nylon gauze. Total cell count, viability and differential count were measured. For detection of mucin, collected samples were treated with sodium dodecyl sulfate polyacrylamide gel electrophoresis and then with monoclonal antibody(HMO2), as the primary antibody, and PAS stain. The amount of mucin was measured with ELISA by HMO2. Correlation with clinical information, cellular analysis, and amount of measured mucin were analyzed. Results : Total cell counts of sputum were significantly increased in patients with bronchiectasis but viability remained the same. Eosinophils were significantly increased in patients with asthma, neutrophils in bronchiectasis chronic bronchitis, respectively (p<0.05). The results of Western blotting and PAS staining confirmed the presence of glycoproteins and matched? with mucin. The amounts of mucin measured by ELISA were not significantly different among the disease groups. Significant correlation was identified between the amount of mucin and viability(r=-0.482, p<0.05). Conclusion : Inflammatory cells in the sputum of those with chronic airway disease were different for each disease type. Measurement of mucin by ELISA via monoclonal antibodies may be a simple method for the evaluation of chronic airway disease.

  • PDF

Case Study on Fracture Type of Wooden Crib Wall (목재 Crib wall의 파괴유형에 대한 사례연구)

  • Shin, Changgun;Paik, Moonyeol;Hong, Cheolhwa;Bae, Wooseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.7
    • /
    • pp.39-50
    • /
    • 2013
  • Crib wall is one of the segmental grid retaining walls using headers and stretchers to establish the framework of the wall. In this method, grids formed by the intersection of headers and stretchers are generally filled with the gravel to maintain the weight of the wall. Therefore, the construction can be carried out with higher speed and much economically when compared with the concrete retaining wall. Furthermore, it has high drain capacity, and environmentally friendly aspects also have been pointed out because the possibility of the planting at the front of the wall. However, in the wooden crib wall method, the relative movement between the individual headers and stretchers was generally recognized, and stress redistribution in the gravel filling was also observed when subjected to the external loading and self-weight of filling. In this study, it was analyzed fracture types and causes of wooden crib wall through detailed investigation and analysis of a large crib wall construction site. As a results, it occurred the damage in the members of 5.7% in a total of 2,315 locations and the damage of header occurred in the members of a header 80.2%. The 65.7% of the damaged header are concentrated in the lower part of crib wall. Therefore, it was analyzed the differences of fracture types and causes of wooden crib wall depending on the installation position and the kinds of members. It is considered basically the members of various forms of distortion and the grain affecting.